• Title/Summary/Keyword: Safety and energy saving

Search Result 123, Processing Time 0.029 seconds

A Study on the Energy Saving and Electric Fire Prevention was Caused by with Interception of Standby Electric Power (대기전력차단으로 인한 에너지절약과 전기화재예방에 관한 연구)

  • Kim, Man-Gun;Lim, Seong-Jin;Lee, Chang-Woo
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.11 no.1
    • /
    • pp.66-73
    • /
    • 2008
  • In this research, the electric power consumptions of the electrical machinery and appliances selected in the Seoul division of Korea Electrical Safety Corporation were measured. The power-saving efficiency was investigated by comparing the amounts of the reserved electric power when the Saver was on or off through measuring that of the reserved electric power before and after equipping the selected appliances with the Saver, a cutoff of the reserved electric power. As a result, the power-saving efficiency was around 18% when the Saver was installed. It can be ascribed to the removal of the source wasting electrical energy. Furthermore, by blocking the reserved electric power, the electric fire can be originally prevented and also the life time of the electrical machinery and appliances can be postponed.

  • PDF

Energy and Safety Efficient LED Street-light Control System Based on Ubiquitous Sensor Network (USN 기반의 에너지 및 안전성 효율적인 LED 가로등 제어 시스템)

  • Cho, Myeon-gyun;Kim, Shik;Yang, Woo Suk
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.6 no.1
    • /
    • pp.25-31
    • /
    • 2011
  • LEDs are becoming the most suitable candidate replacing traditional fluorescent street-light lamps because of its energy efficiency and high brightness. Furthermore, most countries are urging to pursue energy savings in conjunction with IT and sensor network. In order to conserve energy of LED lamp and ensure the safety of pedestrian, we propose a new smart control method for LED light system based on USN using compound sensors, such as illuminance, motion, temperature and humidity sensor. An elaborate simulation shows that the proposed system with a smart control based switching can reduce the energy by 40%, compared to the previous street-light system with a fixed time based switching.

A Study on the Building Energy Efficiency Rating Changes by Enhanced Thermal Insulation Performance of Building Envelope Standards in Apartment Houses (공동주택에서 외피단열성능기준 강화에 따른 건축물에너지 효율등급 변화에 관한 연구)

  • Cho, Yeong Uk;Park, Sun Hyo;Joung, Kwang Sub
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.2
    • /
    • pp.89-95
    • /
    • 2017
  • This study aimed to compare the primary heating energy consumption of regional apartment houses based on the enhanced thermal insulation performance of building envelope standards. The difference of the heating energy consumption based on the enhanced thermal insulation performance of building envelope standards in the southern region, the largest regional difference in primary heating energy consumption, is $10.3kWh/(m^2{\cdot}year)$. The difference of the heating energy consumption based on the enhanced thermal insulation performance of building envelope standards in the central region is $8.0{\sim}8.5kWh/(m^2{\cdot}year)$ and that of the Jeju region is $0.5kWh/(m^2{\cdot}year)$. These energy consumption differences do not result in building energy efficiency ratings changing. The building energy efficiency ratings have the possibility to be changed.

A Hydraulic and Feasibility Study of New Tower Internal in Gas Processing Plants

  • Choo Chang-upp
    • International Journal of Safety
    • /
    • v.3 no.1
    • /
    • pp.15-19
    • /
    • 2004
  • A new tower internal, which is called CSE, is presented. The CSE is composed of a nozzle perforated in its bottom along the entire periphery and equipped with a multi vane axial swirler at the inlet and hollow cylindrical separator at the outlet of the nozzle. According to the experimental work for obtaining the necessary hydraulic information of the CSE, which is used for preliminary design of a separation column, the CSE showed a stable operation over the wide rage of gas/liquid ratio. However, it caused large pressure drop due to the high gas velocity which should carry liquid droplets through the element. The high pressure drop may cause problems in energy recovery and the application of the CSE can be limited to the high pressure columns. Assuming that the tray efficiency of the CSE is the same with the existing separation columns, the results of the column design showed the size reduction of the column diameters by 30 to $40\%$ and investment cost saving, depending on operating conditions. The application of the CSE to separation column may also contribute to the de-bottlenecking the existing column.

ENERGY SAVING EFFECT OF INTELLIGENT EXCAVATING SYSTEM

  • Jeonghwan Kim;Seungwoo Pi;Jongwon Seo
    • International conference on construction engineering and project management
    • /
    • 2013.01a
    • /
    • pp.209-212
    • /
    • 2013
  • Global warming and climate change is now an important issue in every industry. Construction is not an exception. Greenhouse Gases (GHG) are emitted by construction activities such as fuel usage in construction equipment and so on. In light of this, Intelligent Excavating System (IES), which is a robotic excavator with site modeling capability, is developed by a research consortium formed in Korea to improve productivity, quality, and safety of the traditional earthwork. This paper presents that energy saving effect of IES in comparison to traditional method. Through this review, we propose a research strategy to achieve carbon reduction goals in construction industry.

  • PDF

Development of Electrical and Oil Heater for Energy Saving (에너지 절감형 전기 유류 겸용 온풍기 개발)

  • Chung, Sung-Won;Kim, Dong-Keon;Gong, Sang-Ho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.5
    • /
    • pp.38-43
    • /
    • 2011
  • This study was carried out to evaluate the structural stability of hybrid type fan heater. The evaluation of structural safety of hybrid fan heater was conducted by using Ansys Workbench and CFX-11 under the design condition. The hybrid fan heater was operated by heat transfer for heat source supplied from electric heater and combustion gas. According to result of structural analysis, the maximum equivalent stress of hybrid fan heater was 150MPa when the temperature of heat transfer fluids was $150^{\circ}C$. It was found that the hybrid fan was structurally safe because the value of maximum equivalent stress was smaller than that of yield stress of the material.

A Study on the Effective Utilization Plan through Field Investigation and Analysis with Power Transformers in Domestic Areas

  • Shin, Heung-Sik;Lee, Jae-Cheon;Bai, Seok-Myung;Kim, Seon-Gu;Kim, Jin-Tae;Kim, Gi-Hyeon;Jeong, Jong-Wook;Bang, Seon-Bae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.4
    • /
    • pp.88-95
    • /
    • 2007
  • Korea is highly dependent on foreign countries for energy while at the same time having a high energy-consumption industrial structure. Therefore, logical improvements in energy use efficiency and nationwide energy saving are becoming more and more important in coping with the worldwidehigh oil prices and environmental issues such as listed in the Kyoto Protocol to the United Nations Framework Convention on Climate Change. Consequently, a study was conducted on the average annual load factor in domestic areas to set a reasonable and reliable technology standard plan for high-efficiency transformers. The average annual load factor in Korea was discovered to be 18.4[%] classified by industry. This factor is expected to be used in arranging a domestic standard for a minimum efficiency system for transformers, and in reviewing and supplementing the standard transformers plan for the High Energy-Efficiency Appliance Certification. The expected effect from the establishment of the technology standards plan for highly efficient transformers is the expansion of the manufacturing and distribution of highly efficient transformers that are suitable for domestic use. These will lead to electricity cost savings for users, strengthening the related industries' market competitive powers and the effective reduction of greenhouse gases on a national level by drastically reducing loss from transformers, which accounts for a large portion of the total electric supply losses.

A Study on Cold-Weather Curing Quality Management Based on Using Energy Saving Electronic Heater (에너지 절감형 전기히터를 활용한 동절기 양생품질 관리방안)

  • Jo, Man-Ki;Hong, Sung-Min;Park, Jong-Hun;Kim, Jin-Sik;Lee, Dong-Hyun;Cho, Seong-Jun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.109-110
    • /
    • 2020
  • In This study, we tried to review an efficient curing method in consideration of safety and constructability among the problems of winter construction. In other words, as a result of the mock-up test, the measured value of carbon monoxide was 0 ppm in the case of an electric hot air fan. Since there is no carbon monoxide, problems such as suffocation are expected to be solved. In terms of temperature characteristics, electric hot air fans exhibited high thermal efficiency performance with a slight difference in upper/lower temperatures compared to the existing ones. In the future, we plan to conduct thermal efficiency evaluation through actual site performance verification. We will propose an efficient curing method through applicability evaluation.

  • PDF

A basic study on the location of mirror reflector system to improve illumination environment (터널의 조명환경 개선을 위한 반사거울 시스템의 위치 선정에 관한 기초연구)

  • Jeong, Myeong-Soon;Joo, Jae-Sung;Jeong, In-Young;Song, Kyoo-Dong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.13 no.5
    • /
    • pp.385-393
    • /
    • 2011
  • As the economic growth achieved and the straight road was increased. so, the tunnel built more than before. In these days, lighting of tunnel entrance is important for safety and comfortable driving. Most of the tunnel lighting depend on artificial lighting and they use a lot of energy. In this paper, as a research for illumination improvement and saving energy at tunnel, reflecting mirror system is suggested. The performance of the system was evaluated with respect to various aspects. By applying a reflective mirror system, tunnel lighting and environment can be improved. This study is a preliminary study for developing a system to save energy of tunnel artificial lighting.

Basic Study on Geothermal System Application Possibility of a Detached House (단독주택의 지열시스템 적용 가능성에 대한 기초연구)

  • Shin, Hee-Il;Jang, Tea-Ik
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.794-800
    • /
    • 2008
  • Due to high oil prices and global warming problems, researching an alternative energy source and decreasing the energy usage will be the key in the future. Unlike other alternative energy sources, geothermal energy is less dependent on the surrounding environment. Geothermal energy is the ideal energy source for buildings due to the simple and space saving installation. The system is semi permanent once it is installed and this will help reduce the energy usage in controlling the climate in buildings. Geothermal energy does not emit carbon dioxide and other gases that are harmful to the environment. Therefore geothermal energy will be the key in solving high oil prices and a decrease in fossil fuels by applying the geothermal energy system to detached house to counter future energy crisis.

  • PDF