• 제목/요약/키워드: Safety Standard Guideline

검색결과 175건 처리시간 0.032초

영.유아 보육시설의 급식 위생실태 - 충남 아산 지역 중심으로 - (The Foodservice Sanitation Status of the Child Care Centers at Asan City in Chungnam)

  • 송은승;김은경
    • 대한지역사회영양학회지
    • /
    • 제15권6호
    • /
    • pp.806-819
    • /
    • 2010
  • We investigated the foodservice sanitation status of the childcare centers in Chungnam Asan area to provide the information for sanitation guidelines and checklist in various operation types of childcare centers. Self-completed questionnaires were collected from the directors of 95 centers: national-public 9 (9.5%), corporation 10 (10.5%), private 52 (54.7%), and home care 24 (25.3%) types. The analyzed results are shown in foundation type; the investigated items are about critical hygienic problems and safety recognition level, presence of sanitation guideline, demand of dietian's employment and the role, hygienic management and education level, and the present and future of sanitary facility and equipment. From this study we found that home care center, which had low capacity, was comparatively poor at sanitation status, the use of hygienic standard and guideline, and safety recognition level. In our opinion, the use and application of same sanitation standard to any type and size of center is not appropriate and rational. The reestablishment of the sanitation guideline and checklist considering the conditions of various operation types would be necessary. Also periodic hygienic education by hygenic professionals, continuous parents' attention and cooperation of related government organizations are needed for improvement of foodservice sanitation status of childcare centers.

물류용어의 일관성 제고를 위한 원칙과 표준화에 관한 연구 - KS 표준을 중심으로 (A Study on Principles and Standardization of Logistics Terminologies in Korean Standard to Improve Consistency)

  • 김국;유영관
    • 대한안전경영과학회지
    • /
    • 제11권4호
    • /
    • pp.177-191
    • /
    • 2009
  • In this study, we suggest a standardization of the logistics terminologies in Korean Standard to improve its consistency. To support this work, some principles for terminology selection and corrections are studied based on the guideline in international standard. The revised terminologies are summarized in Appendix for 20 logistics-related Korean Standards.

전동식 부항기에 대한 안전성 및 성능평가 가이드라인 개발연구 (Study on Developing Assessment Guideline for Safety and Performance of Electric Cupping Apparatus)

  • 이승호;김은정;신경훈;남동우;강중원;이승덕;이혜정;이재동;김갑성
    • Journal of Acupuncture Research
    • /
    • 제26권6호
    • /
    • pp.101-110
    • /
    • 2009
  • Objectives : We developed and proposed a guideline for safety and performance assessment of electric cupping apparatus(Class 2 medical device). Methods : We drafted the guideline for safety and performance assessment of electric cupping apparatus by referring the existing standards and guideline, based on online questionnaire for Korean medical doctors and measurement data from commercially available products. Physical dimension of cups and inner vacuum pressure were acquired for the measurement in order to achieve the purposes. Results : This guideline only can be applied to electric cupping apparatus for enhancing blood circulation by employing negative pressure generated by electricity. Seven items of appearance and label, operation test of pump, variation test of input electricity, vacuum level test, vacuum sustain test, cup-size dependent test, noise level test are suggested for evaluation subjects and methods required for electric cupping devices. Requirements for the design and development of electric cupping devices are suggested: vacuum level indicator, vacuum generation rate, pressure control, valve detachment stability, cup comparability, safety measure, surge protection, user friendliness, instruction for use (IFU). Conclusions : We proposed a guideline for safety and performance assessment of electric cupping apparatus to improve the quality of relating products and aid the commercialization of them, by aiming higher industrial competitiveness of the medical device sectors in Korea. Discussion with related institutes such as industry, academy and government is further required. Public hearings also need to be held prior to the establishment of a final guideline and standard.

  • PDF

병원약국 대상으로 정맥영양제 조제 실행에 관한 연구-2009 (Survey of Pharmacy Practice for Compounding Parenteral Nutrition in Hospital Setting - 2009)

  • 신혜연;정기화
    • 약학회지
    • /
    • 제54권4호
    • /
    • pp.244-251
    • /
    • 2010
  • Standardized parenteral nutrition is required to improve patient's safety, clinical appropriateness and to increase uniformity between institution and institutions. We assessed the consistency with the American society for parenteral and enteral nutrition (A.S.P.E.N.) practice guideline for PN by evaluating current practice process for parenteral nutrition formulation in inpatients pharmacies in Korea. Each question in this survey was based on 2007 A.S.P.E.N. recommendations of standard parenteral nutrition formulation, the American society of health-system pharmacists (ASHP), and the United State Pharmacopoeia (USP) Chapter 797 guideline for compounding parenteral nutritions. All 90 Korean society of hospital pharmacist (KSHP) member directors of pharmacy were requested to respond to the survey in order to compare the survey results to ASHP national survey of pharmacy practice in hospital settings (2002) in compliance with A.S.P.E.N. guideline. We had final response rate of 35.6%. 25 (100%) hospitals complied with this Garb guideline (response rate was 84.4%) which was the highest compliance. Only 17.9% of hospital pharmacies were actively involved in complications monitoring. Monitoring complications and efficacy were least in compliance with the A.S.P.E.N. guideline. 69.0% of Korean pharmacists adjusted medication dosage based on disease state or monitoring laboratory data in compliance with the A.S.P.E.N. guideline. Over 50% of the hospital pharmacies failed to provide and evaluate staff training in aseptic manipulation skills periodically. Korean hospital pharmacies need to comply with the standard practice guideline for compounding sterile preparation in order to provide better quality of parenteral nutrition service for specific patient population.

유니버설 디자인의 원리와 지침에 의한 노인복지시설 기준 분석: 법률 규정을 중심으로 (Analysis of Facility Standard for Elderly Welfare Facility by Universal Design Principle and Guideline: Focusing on Legal Regulations)

  • 김수정
    • 산업융합연구
    • /
    • 제15권1호
    • /
    • pp.1-7
    • /
    • 2017
  • The purpose of this study is to analyze the facility standards of the elderly welfare facilities applying the seven principles of the universal design. The facility standards of the elderly welfare facilities were limited to the provisions of the "Enforcement Regulation of the Elderly Welfare Act". There are few legal regulations applying the universal design in the construction of the elderly welfare facilities. The facility standards are set only with the minimum requirements such as securing the safety of the user, securing the space area, functional convenience, and risk prevention. However, the contents of the regulations are limited to the minimum standards for functional convenience and safety required for living. In conclusion, in the elderly welfare facilities, the notion of universal design, which considers not only the elderly, but also service providers, employees, and general visitors, should be considered.

  • PDF

동력집중식 고속열차의 충돌안전도 표준설계 가이드라인 도출 (A Derivation of the Standard Design Guideline for Crashworthiness of High Speed Train with Power Cars)

  • 김거영;조현직;구정서;권태수
    • 한국자동차공학회논문집
    • /
    • 제16권6호
    • /
    • pp.157-167
    • /
    • 2008
  • Through this study, the standard design guidelines for high speed train with power cars have been derived to meet the crashworthiness requirements of the Korean rollingstock safety regulation. The crashworthiness regulation requires some performance requirements for two heavy collision accident scenarios; a train-to-train collision at the relative speed of 36 kph, and a collision against a standard deformable obstacle of 15 ton at 110 kph. A standard high speed train composition was defined as 2PC-2ET-6T with 17ton axle load, similar to KTX-2 for the Honam express line. Using theoretical and numerical analyses, some crashworthy design guidelines were derived in terms of mean crush forces and energy absorptions for major crushable components. The derived design guidelines were evaluated and improved using one dimensional spring-mass dynamic simulation. It is shown from the simulation results that the suggested design guidelines can easily satisfy the domestic crashworthiness requirements.

국내병원 간호사의 인수인계 실무표준, 표준지침 및 표준화된 항목 개발에 대한 연구 (Development of Nursing Handoff Practice Guideline and Standards for Korean Hospital)

  • 김은만;유미;이향열;고지운;조의영;김을순
    • 임상간호연구
    • /
    • 제20권1호
    • /
    • pp.1-14
    • /
    • 2014
  • Purpose: Addressing current status of nursing handoff provides information as to where to change practice for improvement in patient care. The aim of this study was to develop nursing a handoff practice guideline and standardsfor Korean hospitals. Methods: A questionnaire was used to collect data in a cross-sectional survey with 207 head nurses and 697 nurses working in general hospitals. Results: The practice guideline consisted of 2 items on purpose of handoff, 5 items on policy, 3 on environment, 5 on process, 7 on content, 3 on evaluation, and 1 on the function of education, for a total 26 of items. Standard instruction was developed related to Patients, Assessment, Situation, Safety concerns, Background, Actions, and Recommendations. Conclusion: The findings of this study indicate that the guideline can be applied in real nursing practice to improve the effectiveness of handoff procedures. It can be used to guide nurses to follow the standardized content, which presents patient details clearly. The guideline provides consistency and structure for the information that is handed over.

한국형 PBD 가이드라인의 구축을 위한 국외 성능설계 분석 (The Analysis of Abroad PBD for Development of Korea PBD Guideline)

  • 이병흔;진승현;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 추계 학술논문 발표대회
    • /
    • pp.67-68
    • /
    • 2017
  • In the case of korea, it was enforced the performance based design in 2011 for fire safety to the construction that is hard to safety secure by code based design. However as a result of domestic performance design case analysis, as it conducts that the standard is insufficient, most of cases show that they use the method of adding facilities by strengthening legal standards. Therefore on this study, it conducts the analysis of Performance based design seminar data that it was done by SFPE and each countries Performance based design guidelines. Also based on this, it will use the basic data for developing the domestic performance based design guideline.

  • PDF

넘어짐(전도) 재해예방 안전기준 개정(안) 연구 (A study of improvement on safety regulation for slip, trip and fall prevention)

  • 김정수
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2013년 춘계학술대회
    • /
    • pp.19-29
    • /
    • 2013
  • Slips and falls are associated with many occupational injuries in Korea. It is also estimated that slipping are major contributors to slip, trip and fall injury burden. So "LOCAL RULE ON OCCUPATIONAL SAFETY AND HEALTH STANDAR D" must be improved, especially article 3(prevention of slip, trip and fall). The primary purpose of the present study is to determine if, and to what extent, the standard could be improved in present environment. In order to fulfill our objective, the another regulation in Korea and foreign countries were investigated and reviewed. Many kind of standard, mandatory documents and guideline were also reviewed. And then, regulations, standard, guideline etc. reviewed were compared with each others. The article 3 was revised as below. 1. The floors of the traffic route in workplace shall have no hole or slope, or be uneven or slippery so as, in each case, to expose employees to slip, trip and fall risk, except if adequate measures have been taken to prevent a employees falling. 2. The employer shall design, install and fix the drain for effective drainage if fluid contaminants were frequently occurred. So far as is reasonably practicable, An employer shall keep the workplace clean, sanitary, and dry so that employees won't have any risk to tripping or slipping at the workplace. 3. To facilitate cleaning, every floor, workplace, and passageway shall be, so far as is reasonably practicable, kept free from protruding objects, splinters, holes, etc. Also, some criteria was developed in this study. Standard and criteria developed in this study will help to prevent slip, trip, and fall injuries.

  • PDF

피난설계 예시도면 작성을 통한 피난소요 시간 비교.분석 연구 (The comparative analysis on escaping time for fire escape design)

  • 김대희;황은경;조정훈;황금숙
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 춘계학술논문발표회 논문집
    • /
    • pp.261-264
    • /
    • 2008
  • A guideline to complement safety problem of escape code at the fire controlling design stage was shown by comparing & analysing developed fire controlling countries such as US, UK, Japan, and etc. and appropriateness of improving legislations for building standard of escape code was examined by comparing & analysing escaping time with escape code simulation(SIMULEX, EXDOUS) as the guideline.

  • PDF