• Title/Summary/Keyword: Safety Monitoring

Search Result 2,866, Processing Time 0.031 seconds

Distributed optical fiber sensors for integrated monitoring of railway infrastructures

  • Minardo, Aldo;Coscetta, Agnese;Porcaro, Giuseppe;Giannetta, Daniele;Bernini, Romeo;Zeni, Luigi
    • Structural Monitoring and Maintenance
    • /
    • v.1 no.2
    • /
    • pp.173-182
    • /
    • 2014
  • We describe the application of a distributed optical fiber sensor based on stimulated Brillouin scattering, as an integrated system for safety monitoring of railway infrastructures. The strain distribution was measured statically and dynamically along 60 meters of rail track, as well as along a 3-m stone arch bridge. We show that, gluing an optical fiber along the rail track, traffic monitoring can be performed in order to identify the train passage over the instrumented sector and determine its running conditions. Furthermore, dynamic and static strain measurements on a rail bridge are reported, aimed to detect potential structural defects. The results indicate that distributed sensing technology represents a valuable tool in railway traffic and safety monitoring.

An Effect of Safety Coaching Program on Safety Behavior and Climate -Focusing on Expressway Safety Patrol- (안전 코칭 프로그램이 안전행동과 안전 분위기에 미치는 효과 -고속도로 안전순찰원을 중심으로-)

  • Jongdo Seo;Bongjun Suk;Kwangsu Moon
    • Journal of the Korean Society of Safety
    • /
    • v.39 no.2
    • /
    • pp.54-64
    • /
    • 2024
  • This study investigated the impact of a safety coaching program on the safety behavior and safety climate among expressway safety patrols. Four to seven patrols from each of the three branches participated in this study. The safety coaching program was developed based on the GROW model, with main contents including recognizing individual differences, exploring safety values, communicating near-misses, providing effective and efficient feedback, employing non-violent communication, and fostering commitment toward safety behaviors. Additionally, each session included self-monitoring and peer review of each item based on a critical behavior checklist developed for this study, with challenging goals set based on the monitoring and review. The safety coaching program comprised six sessions in three branches, while three other branches were assigned as a control group. A non-equivalent control group experimental design was applied. Dependent variables included observed and perceived safety behavior, safety climate, psychological safety, and feedback. The results indicated that the safety coaching program effectively increased patrols' safety behavior and safety climate. Furthermore, psychological safety and feedback improved. These findings suggest that the developed safety coaching program could serve as an alternative method to enhance safety management for expressway safety patrols. Finally, the implications, limitations, and directions for future research are discussed.

A Study on Safety System for Blasting Workers using Real Time Location System in the Shipyard (선박용 블라스팅 셀 내에서의 실시간 위치 추적 기술을 이용한 작업자 안전 시스템에 대한 연구)

  • Yun, Won-Jun;Ro, Young-Shic;Cho, Sang-Bock
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.47 no.6
    • /
    • pp.836-842
    • /
    • 2010
  • Safety system including location monitoring system for blasting workers was studied. Positioning performance of the location monitoring system was highly dependent on communication protocol and the number of access points in the blasting cell. RTLS(Real Time Location System) is an important technology to develop the location information of workers and variously used to enhance workers safety. Location monitoring system with Cell-ID and RSSI wireless communication technology was verified to have a proper positioning performance for the steel block application.

Web-based Real Time Failure Diagnosis System Development for Induction Motor Bearing (유도전동기 베어링의 원거리 실시간 결함진단시스템 개발)

  • Kwon, Oh-Heon;Lee, Seung-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.3 s.71
    • /
    • pp.1-8
    • /
    • 2005
  • The industrial induction motor is widely used in the rotating electrical machine for the transmission of power. It is very reliable equipment, but it could lead to the loss of production and lift when failure occurs. Therefore, the failure data is acquired and analyzed by attaching an exclusive instrument to existing induction motor. However, these instruments could lead to side effects, increasing the production costs, because they are very expensive. The purpose of this study is the development of an induction motor bearing failure diagnosis system constructed using LabVIEW which can be supplied the kernelled function, process monitoring and current signature analysis. In addition, the availability and reasonability of the constructed system was examined for an induction motor with failure defects in outer raceway and ball bearing. From the results, it shows that failure diagnosis system constructed is useful for real-time monitoring with detection of bearing defects over the web.

Research on Design of DDS-based Conventional Railway Signal Data Specification for Real-time Railway Safety Monitoring and Control (실시간 철도 안전관제를 위한 DDS 기반의 일반철도 신호 데이터 규격 설계 연구)

  • Park, Yunjung;Lim, Damsub;Min, Dugki;Kim, Sang Ahm
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.4
    • /
    • pp.739-746
    • /
    • 2016
  • The real-time railway safety monitoring and control system is for prevention of safety accidents, and this system adopts DDS (Data Distribution Service) standard based data transmission method to support integrated management of data from existing on-site safety detection devices. In this paper, we introduce the design of DDS-based data specification from on-site signal equipment on the conventional railway. For this, we (1) design UML data model of KRS SG 0062 standard which defines existing data specification, (2) define DDS Topics for DDS transmission and map KRS model to DDS Topic model, (3) suggest data transformation rules and (4) design network control QoS polices. In addition, we analysis actual on-site log data and validate our data specification design. DDS-based data transmission enables data compatibility among on-site devices and the real-time railway safety monitoring and control system, and allows efficient network management for a large amount of data transfer.

Development of Diagnostic and Monitoring Method for Concrete Structure Using AE (AE를 이용한 콘크리트 구조물 진단 및 감시 방법의 개발)

  • 최기상;최기홍
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.3
    • /
    • pp.146-154
    • /
    • 1999
  • The feasibility of using AE for monitoring mechanical failure in concrete structures has been tested. Specifically, the relationship between the fracture and the characteristics of AE signal is theoretically and experimentally investigated. The experimental results manifest that the high sensitivity of AE signal to the fracture of concrete structure makes it a good choice as sensor for monitoring concrete structure.

  • PDF

A Safety Evaluation Strategy Employing Bridge Health Monitoring System by Traffic Loads (교량 상시계측시스템을 이용한 실시간 안전성평가시스템 구축 방안)

  • Lee, Woo-Sang;Joo, Bong-Chul;Park, Ki-Tae
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.481-484
    • /
    • 2008
  • The research was carried out to suggest the bridge health monitoring systems that have been composed damage detection algorithm and a system for evaluation load carrying capacity of bridge by traffic loads for the purpose of safety management of bridge structure in efficient and economic.

  • PDF

Problems of Assignable Causes in Process Monitoring and Adjustment (공정 모니터링과 조절에 있어 이상원인의 문제)

  • 이성철;전상표
    • Journal of the Korea Safety Management & Science
    • /
    • v.2 no.4
    • /
    • pp.19-32
    • /
    • 2000
  • Assignable causes producing temporary deviation from the underlying system can influence on process adjustment and process monitoring in dynamic feedback control system. In this paper, the impact of assignable causes on EWMA forecasts and process adjustment which is based on the EWMA forecasts are derived for optimum control methods.

  • PDF

A Numerical Study to Analyze Safety of Pressure Leakage Monitoring System of Gas Extinguishing Agent (가스소화약제 압력누기감시장치의 안전성 분석을 위한 수치적 연구)

  • Go, A-Ra;Lim, Dong-Oh;Son, Bong-Sei
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.103-110
    • /
    • 2016
  • While the demand for the gas system fire extinguishers increases every year, there are insufficient safety measures for assessing the extinguishing performance, such as system safety and reliability in the preparation of increasing demand, which has emerged as a social problem. One of the most critical causes of accidents occurring with the gas extinguishing system is pressure leakage from the extinguishing agent storage container. This is considered to be one of the critical factors on which the success of fire suppression depends. In this study, its safety measure was studied, Because it was deemed urgently necessary. The newly developed pressure leakage monitoring system is a system monitoring storage condition, pressure, leakage and discharge of the storage container related to agent concentration, which is one of the critical factors for fire suppression. This was developed to be applicable to the $CO_2$ and HFC-23 systems. Therefore, for structural safety analysis, the safety performance was verified by the fluid structure coupling analysis of the safety problems that may occur when the pressure leakage monitoring system is applied to the gas fire extinguisher. For analysis programs, the FloEFD program from Mentor Graphics was used for computational fluid dynamics analysis and ABAQUS from Dassault Systems was used for structural analysis. From the result of numerical analysis, the structure of $CO_2$ did not develop plastic deformation and its safety was verified. However, plastic deformation and deviation issue occurred with the HFC-23 monitoring system and therefore verified the structural safety of pressure leakage monitoring system by data obtained from redesigning and adjusting the condition of numerical interpretation three times.

Evaluation of the Possession of Measurement and Analytical Instruments in Domestic Work Environment Monitoring Service Providers (II) (국내 작업환경측정기관의 측정 및 분석장비 보유실태에 대한 고찰 (II))

  • Jang, Jae-Kil
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.2
    • /
    • pp.182-192
    • /
    • 2014
  • Objectives: The aim of this study is to analyze the current status of possession of measurement and analytical instruments at work environment monitoring organizations and their relationships with human resources, including the number of professional engineers and evaluation scores resulting from evaluation programs in 2012. Materials: Data for measurement and analytical instruments were gathered by inspectors who had been assigned by the Korea Occupational Safety and Health Agency(KOSHA) and the Ministry of Employment and Labor(MoEL) during the evaluation program for 2012. Data for 11 monitoring instruments and nice pieces of analytical equipment were collected from 103 organizations. Additional data such as the type of service provides and the number of professional engineers employed were also recorded by the inspectors. Evaluation scores could be acquired from KOSHA. Results: Comprehensive Occupational Health Service Providers showed good operation quality, while University or Hospital Subsidiary and Work Environment Monitoring Organizations recorded relatively poor results. Evaluation scores correlated well with the possession of measurement instruments and human resources for each organization. High yields provided by professional engineers also showed statistically-associated contributions to evaluation scores and monitoring instrument possession. Compared with monitoring instruments, the amount of analytical equipment had little positive impact on organizations' competence. Conclusions: The evaluation results for domestic monitoring organizations revealed that human resources, possession of instruments, and the quality of employees were critical factors for operating the corporations. Each organization should give considerable effort to improving their ability to strengtheninternal quality, resulting in high-yield production for workers and employers by providing improved workplace monitoring services.