• 제목/요약/키워드: Safety Lamp

검색결과 132건 처리시간 0.024초

UV lamp와 TiO2 광촉매를 이용한 공기 정화에 관한 연구 (A Study of Air Freshing by UV lamp and TiO2 Catalyst)

  • 이건덕;우인성;황명환;이인복;김관중;박화용
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2011년도 춘계학술대회
    • /
    • pp.205-227
    • /
    • 2011
  • On this study, the test for air-purification was executed as using the UV lamp and the UV lamp on which the TiO2 catalyst had been deposited with glass fiber in the reactor chamber. It aimed at the basic data of air-purifier as assessing the features of removing abilities for various contaminants including CH3COOH, NH3, NO, and SO2 as varying the number of TiO2 coating, the wave of UV lamp, and the amount of additive CaO as variables.

  • PDF

Comparative Evaluation of Loop-Mediated Isothermal Amplification (LAMP) and Conventional PCR for Detection of Shiga-Toxin-Producing Escherichia coli (STEC) in Various Food Products

  • Hyejin Jang;Yong Sun Cho
    • 한국식품위생안전성학회지
    • /
    • 제38권5호
    • /
    • pp.347-355
    • /
    • 2023
  • 본 연구에서는 시가독소 생성 대장균(STEC)을 검출하기 위해 식품공전의 polymerase chain reaction (PCR)검사법과 loop-mediated isothermal amplification (LAMP)를 비교하였다. PCR 및 LAMP의 검출 한계(LOD) 및 정량화 한계(LOQ), 민감도, 특이성 및 효율성을 평가하기 위해 다양한 식품에 STEC를 접종하였다. LOD는 PCR의 경우 104 CFU/mL 이하, LAMP의 경우 103 CFU/mL 이하로 측정되었다. LOQ 값은 PCR과 LAMP 간에 차이가 없었다. 그러나 4가지 식품군에서 민감도는 양념육이 최대 11.1%, 간소고기가 최소 8.1% 차이가 났다. LAMP는 네 가지 음식 유형 모두에 대해 높은 민감도와 100% 특이도를 보였다. 따라서 LAMP는 식품 유형에 따라 검출률이 비슷하고 특이도와 민감도가 식품공전 PCR보다 우수하기 때문에 STEC에 대한 신뢰할 수 있는 분자 검출 방법이다.

TiO2 코팅과 CaO 첨가에 따른 독성물질 제거에 관한 연구 (A study on the removing of contaminants by TiO2 coating and CaO additive)

  • 우인성;이건덕;황명환;이홍주
    • 대한안전경영과학회지
    • /
    • 제15권3호
    • /
    • pp.127-132
    • /
    • 2013
  • This study shows an air-purification test by the UV lamp on which TiO2 catalyst is deposited with glass fiber in the reactor chamber. This test was based on the fundamental data of air-purifier as assessing a removing ability on various contaminants such as CH3COOH, NH3, NO and SO2 as variation of the TiO2 coating, the wave of UV lamp, and the additive CaO. As a result, the highest decomposing removal ratio was shown when 5-times coated glass fiber was used. It can be due to the recombination reaction of electrons and electron-hole in the loaded CaO. Thus, the decomposing removal ratio increased as the recombination ratio decreased. In addition, it was confirmed that the decomposing removal ratio lowered when CaO was considerably deposited because it hided the lamp of OH-1 radical.

LED조명의 광생물학적안전성 도입을 위한 IEC 62471 규격 분석 (Analysis on IEC 62471 for The Introduction of Photobiological Safety of LED Lamp)

  • 고재규;조미령;이민진;김주현
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2012년 추계학술대회
    • /
    • pp.435-443
    • /
    • 2012
  • First introduced in 1962, LED(light-emitting diodes) emitted low-intensity red light, but modern versions are now available across the ultraviolet, visible, and infrared spectrum, many with very high luminance or brightness. As a result, growing importance of potential safety harzards for human. Now when certificated of CE provide that testing through IEC/EN 62471 for any lamp. Korea standard adopted as it IEC 62471:2006, Photobiological safety of lamps and lamp systems without change, but effectiveness is incomplete. In this paper, we introduce analysis and direction that urgently come into effectiveness of KS C IEC 62471 as a national standard specifications.

  • PDF

형광등용 안정기의 발화 및 용융흔 분석에 관한 연구 (A Study on the Ignition and Molten Mark Analysis of Ballast for Fluorescent Lamp)

  • 최충석;박창수;김혁수;김향곤;정재희
    • 한국산업안전학회:학술대회논문집
    • /
    • 한국안전학회 1998년도 추계 학술논문발표회 논문집
    • /
    • pp.173-177
    • /
    • 1998
  • In this paper, we reported an outbreak of fire hazard of ballast for fluorescent lamp. The surface structure and composition of ballast coil analyzed by using metallurgical microscope, scanning electron microscope(SEM) and energy dispersive x-ray spectroscopy(EDX). The surface of molten mark appeared columnar structure and void. EDX analysis indicated that the molten mark spectra were composed not only of the corresponding original spectra but also of several new lines.

  • PDF

UVB조사기의 홍반 발생 특성과 안전성에 관한 연구 (The Study of Characteristic of Induced Erythema and Safety by UVB Lamp)

  • 박래준;조용호;박소현;이윤미
    • The Journal of Korean Physical Therapy
    • /
    • 제18권3호
    • /
    • pp.79-87
    • /
    • 2006
  • Purpose: The present study purposed to examine induced characteristic or erythema and safety by medium wave ultra violet(UVB) lamp. Methods: We compared sunshine and UVB lamp using spectroradiometer and UV radiometer. For measuring sunshine irradiation, we used spectoradiometer and detected from 8 to 18 o'clock every each hour on the beach, playground and rooftop of a 5 story building. The subjects for erythema examination were 5 healthy subjects who have no pathologic history of photosensitivity reaction, psoriasis and vitiligo. They were exposed to UVB radiation at the abdominal area for 2 hours and after irradiation, we observed the change of skin color every 12 hours over a period of 1 week. Results: Between sunshine and UVB lamp, sunshine had higher data on the chromaticity coordinates, dominant and peak wavelength, bandwidth and purity than the UVB lamp but on the color temperature, brightness the UVB lamp had higher data than the sunshine. In comparison of sunshine and UVB lamp, UVB lamp irradiated constantly such as $3.9-4.4{\mu}W/cm^2$ at a distance of 100cm between bed and lamp which was same as early morning irradiation on the sunshine. The erythema didn't appear to any subject. Conclusion: This results suggest that the UVB lamp has lower irradiance as much as early sunshine. Therefore the UVB lamp had no influence of inducing erythema at a distance of 100cm between bed and lamp.

  • PDF

Fluid Flow and Heat Transfer in a Super high-Pressure Mercury Lamp using CFD

  • Jang, Dong Sig;Lee, Yeon Won;Li, Kui Ming;Parthasarathy, Nanjundan;Choi, Yoon Hwan
    • International Journal of Safety
    • /
    • 제11권2호
    • /
    • pp.5-9
    • /
    • 2012
  • The discharge properties of super high-pressure mercury lamp are due to resistance heating for energy input, and results in temperature increase. The cooling equilibrium state is reached by the heat conduction, convection and radiation. In order to predict the fluid flow and heat transfer in and around the mercury lamp accurately, its visualization is of utmost importance. Such visualization is carried out by CFD program in this study. We focus on Anode shape to calculate four cases, namely AA, AB, AC and AD separately, and compare the temperature distribution and velocity vector in each case to predict cooling capacity and fluid flow properties. It can be concluded that the shape of anode plays an important role that affects the fluid flow and heat transfer in a mercury lamp.

이륜자동차 등화장치 검사기준에 관한 연구 (Study on the Inspection Standards of Motorcycle Lamps)

  • 홍승준;임재문;하태웅
    • 자동차안전학회지
    • /
    • 제8권4호
    • /
    • pp.6-11
    • /
    • 2016
  • The objective of this study is to present the inspection standards of motorcycle lamps affecting motorcycle traffic accident in night time. The inspection standards of motorcycle lamps recommended by CITA International Motor Vehicle Inspection Committee are surveyed. Also, the domestic safety standards of motorcycle and inspection standards of passenger car are considered. The inspection standard and method with principal reasons of rejections of head-lamp, number plate lamp, front-rear position lights, stop lamp and direction indicators of motorcycles are suggested.

A Life Cycle Cost Comparison of Low-pressure Sodium Lamp and Fluorescent Lamp for Tunnel Lighting

  • Lee, Young-Q.
    • Industrial Engineering and Management Systems
    • /
    • 제3권1호
    • /
    • pp.59-62
    • /
    • 2004
  • The number of tunnel has fast increased with the rapid expansion of highway network. Tunnel should be designed to provide for drivers both safety and pleasant driving conditions. In this perspective, the design for tunnel lightning is very important in order to provide its safety, pleasantness, and cost-efficiency of maintenance, all of which should be considered and analyzed for a better tunnel lighting. This paper attempts to compare the low-pressure sodium lamp, which have usually been used for tunnel lighting, with the fluorescent lamp, which we consider as an alternative for the former. In an effort to determine the number of lamps to meet the required illuminance in the tunnel, this research employs a simulation technique which would allow us to conjecture, with the aid of basic model, the life cycle cost for illumination per each tunnel. This analysis is expected to provide a basic method and related information for tunnel development and design.

형광램프 대체 컨버터 내장형 LED램프의 안전성 확보방안 (A study on the safety LED lamp using internal control gear as the alternative type of fluorescent lamp)

  • 고재준;김충혁
    • 조명전기설비학회논문지
    • /
    • 제29권3호
    • /
    • pp.30-38
    • /
    • 2015
  • As products using LEDs are developed actively, also there has been large request for LED products that can replace traditional lamps like fluorescent lamps and metal halide lamps. But so far there is no proper standard that manufacturer can use and test it. As a result manufacturer can't develop retrofit LED lamps and sell it even they have technology. In this study, by analyzing control gear for fluorescent lamp that is currently used in market which is magnetic or electronic ballast, I'd like to develop proper test method by investigating compatibility between all-type control gear and LED retrofit products.