• 제목/요약/키워드: Safety Lamp

검색결과 132건 처리시간 0.023초

휴대형 방폭등의 경량화 연구 (A Study on the Light Weight Hand Lamp for Explosion-Proof Type)

  • 최상원
    • 한국안전학회지
    • /
    • 제28권2호
    • /
    • pp.31-36
    • /
    • 2013
  • For lighting of dark and hazardous workplace such as compartment of ships under construction, workers should use hand lamps of explosion-proof type. However, the heavy weight of such lamps has prevented most impatient workers from using such types of lamps extensively. In this paper, we developed a light weight hand lamp of intrinsic safety type which reduced the weight a lot while maintaining or improving the lighting and explosion-proof function. We made a prototype which consisted of lamp fixture and high frequency power supply. Testing results show that the hand lamp meets well all the explosion-proof testing requirements of the Korea Occupational Safety and Health Agency. And more, we surveyed the explosion protection technology of a light weight hand lamp, and suggested the advantage/disadvantage to apply lighting of hand lamp about economical aspect.

가로등설비 누전시 건조상태와 침수상태에 대한 전위분포 분석 (The Analysis on the Electric Potential Distribution of Dry and Submerged Condition by Electric Leakage in Street Lamp)

  • 홍성호;박상태;김상철
    • 한국안전학회지
    • /
    • 제23권6호
    • /
    • pp.44-50
    • /
    • 2008
  • This paper presents study on the electric potential distribution when have a short in street lamp. In order to measure electric potential testing ground is built in. A experiment is conducted to simulate dry and submerged situation of street lamp. The street lamp is leaked by artificial means. And electric potential is measured in grounded street lamp and street lamp alone. The results show that touch voltage of grounded street lamp is possible more high than street lamp alone. And the electric shock hazard is high because high electric potential is distributed near submerged street lamp. Also if street lamp is submerged ground is not useful to decrease electric shock hazard.

시트벨트 경고등 점등불량 개선: Red-X 적용사례 (Seatbelt alarm lamp lam-function improvement: Red-X a case application)

  • 문찬오;김창은
    • 대한안전경영과학회지
    • /
    • 제9권6호
    • /
    • pp.171-179
    • /
    • 2007
  • The objective of this GM Red-X project was to reduce customer complaints on Kalos, Lacetti, Magnus as reported through 2004.1 - 2005.1 warranty performance. Seatbelt alarm lamp mal-function problem is connected with safety. So it is critical issue. Seatbelt alarm lamp mal-function which caused by buckle occurred 22 cases from 2004.1 to 2005.1.

우사(牛舍)에서의 할로겐보온등군(群) 및 자동급수통군에 대한 전기배선의 열적 특성 (Thermal Characteristics of Electric Wiring for Halogen Warm Lamp Group and Automatic Waterer Group at Stable)

  • 김두현;유상옥;김성철
    • 한국안전학회지
    • /
    • 제29권4호
    • /
    • pp.48-53
    • /
    • 2014
  • This study is analyzed for electrical fire danger by electric equipments through surveys of stable owners and the field investigation at 64 stable. Also, an experiment is performed to analyze the thermal characteristics of 4 types electric wiring according to the number of operating halogen warm lamp group and automatic waterer group in Beon-young stable in the Cheongwon location. The survey is done to investigate the occurrence of electrical fire, electric equipment, causes and dangerous equipment. As a result, halogen warm lamp group and automatic waterer group are found to have dangerous loads. In the field investigation, the mode of load capacity of the halogen warm lamp group and automatic waterer group was investigated. The mode of load capacity of halogen warm lamp group (over 3 years) is found 17A and that of the auto waterer group (10 years) is 16A. In this experiment, the halogen warm lamp group aged at least 3 years showed $109^{\circ}C$ while that aged less than 1 year appeared $83^{\circ}C$, showing the max gap of $26^{\circ}C$. The automatic waterer group aged 10 years showed $90^{\circ}C$ while that aged less than 1 year appeared $68^{\circ}C$, showing the max gap of $22^{\circ}C$. These findings indicate that the mode of load capacity needs to be considered in selecting and installing wiring for the electric equipment construction of halogen warm lamp group and automatic waterer group in stable.

Study on the Performance of Infrared Thermal Imaging Light Source for Detection of Impact Defects in CFRP Composite Sandwich Panels

  • Park, Hee-Sang;Choi, Man-Yong;Kwon, Koo-Ahn;Park, Jeong-Hak;Choi, Won-Jae;Jung, Hyun-Chul
    • 비파괴검사학회지
    • /
    • 제37권2호
    • /
    • pp.91-98
    • /
    • 2017
  • Recently, composite materials have been mainly used in the main wings, ailerons, and fuselages of aircraft and rotor blades of helicopters. Composite materials used in rapid moving structures are subject to impact by hail, lightning, and bird strike. Such an impact can destroy fiber tissues in the composite materials as well as deform the composite materials, resulting in various problems such as weakened rigidity of the composite structure and penetration of water into tiny cracks. In this study, experiments were conducted using a 2 kW halogen lamp which is most frequently used as a light source, a 2 kW near-infrared lamp, which is used for heating to a high temperature, and a 6 kW xenon flash lamp which emits a large amount of energy for a moment. CFRP composite sandwich panels using Nomex honeycomb core were used as the specimens. Experiments were carried out under impact damages of 1, 4 and 8 J. It was found that the detection of defects was fast when the xenon flash lamp was used. The detection of damaged regions was excellent when the halogen lamp was used. Furthermore, the near-infrared lamp is an effective technology for showing the surface of a test object.

초정압 방전램프(UCD)를 적용한 안전 조명 장치에 관한 연구 (An Experimental Study on the a Light Device which Adopt Safety Ultra Constant Dischange Lamp)

  • 정풍기;김영철
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2010년도 추계학술대회
    • /
    • pp.63-80
    • /
    • 2010
  • This paper describes the development of various lighting equipment adapting Ultra Constant Discharge Lamp that has newly been on commercial supply in the market. Meeting the required conditions of lighting equipment, various types of UCD Lamp equipment with excellent performances could be successfully developed. In order to provide a guideline for the economical lighting product selection, the analyzed data comparison between Hi-pressure Sodium Lamp which has been the most popular lamp for street lighting and UCD Lamp is provided. The conclusions of the study are made as follows; (1) The performance measurement result of UCD Lamp shows excellent Luminous Efficacy as 108Lm/W, daylight-like Color Rendering Index as 90Ra, and the best operating temperature range as $-50^{\circ}C{\sim}+85^{\circ}C$. Comparing to the Hi-pressure Sodium Lamp, UCD could be evaluated as much superior products. (2) In an assembled status with the lighting fixture (Type STB형-60W), UCD Lamp was tested OK for one hour duration at the temperature range form $-50^{\circ}C$ to $+85^{\circ}C$ and the humidity of 98%. The operation at the extremely low temperature can be an excellent feature to enable the export to the cold temperature regions such as Northern Europe and Russia and the specific applications for defense systems and special industry. (3) As UCD Lamp is a genuine Korea made product following Energy-saving and Eco-friendly policy, it should be appreciated as one of the best $CO^2$ reduction Green product.

  • PDF

백열전구 복사열에 의한 미송판의 발화 임계거리 및 발화시간 예측 (Predicting of Ignition Time and Critical Distance for Ignition of Douglas fir by Radiant Heat of Incandescent Lamp)

  • 이흥수;김두현
    • 한국안전학회지
    • /
    • 제31권2호
    • /
    • pp.18-25
    • /
    • 2016
  • The incandescent lamp is an electric light fixture with a tungsten filament heated to a high temperature, by passing an electric current through it, until it glows with visible light. The hot filament is protected from oxidation with a glass bulb that is filled with inert gas. The incandescent lamp has fire risk when combustible materials are close to its glass bulb. Because its lamp has the property which converts 90~95 percents of the electric power to heat energy. 2015 national fire statistics show that fires caused by lighting fixtures were 652 cases, and incandescent lamps(44 cases) and halogen lamps(53 cases) accounted for 15 percents in those of high heating light fixtures. Since incandescent lamp fires account for about 45 percents in the high heating light fixture, we could not overlook the fire risks by the incandescent lamp. Although many studies related with those have been conducted, incandescent lamp fires are continuously occurred. This study was carried out to study the fire risk of ignition of wood due to radiant heat of incandescent lamp. Radiant heat flux of the incandescent lamp was predicted by applying point source model, and critical distance for ignition of wood was calculated by applying integral model. The results from this study could applied to fire prevention activities related to light bulb, and it could be used in fire cause investigations related to radiant heat of incandescent lamp.

초정압 방전램프(UCD)를 적용한 안전조명 장치에 관한 연구 (An Experimental Study on the a Light Device which Adopt Safety Ultra Constant Dischange Lamp)

  • 정풍기;김영철
    • 대한안전경영과학회지
    • /
    • 제12권4호
    • /
    • pp.41-51
    • /
    • 2010
  • This paper describes the development of various lighting equipment adapting Ultra Constant Discharge Lamp that has newly been on commercial supply in the market. Meeting the required conditions of lighting equipment, various types of UCD Lamp equipment with excellent performances could be successfully developed. In order to provide a guideline for the economical lighting product selection, the analyzed data comparison between Hi-pressure Sodium Lamp which has been the most popular lamp for street lighting and UCD Lamp is provided. The conclusions of the study are made as follows; (1) The performance measurement result of UCD Lamp shows excellent Luminous Efficacy as 108Lm/W, daylight-like Color Rendering Index as 90Ra, and the best operating temperature range as $-50^{\circ}C{\sim}+85^{\circ}C$. Comparing to the Hi-pressure Sodium Lamp, UCD could be evaluated as much superior products. (2) In an assembled status with the lighting fixture (Type STB형-60W), UCD Lamp was tested OK for one hour duration at the temperature range form $-50^{\circ}C$ to $+85^{\circ}C$ and the humidity of 98%. The operation at the extremely low temperature can be an excellent feature to enable the export to the cold temperature regions such as Northern Europe and Russia and the specific applications for defense systems and special industry. (3) As UCD Lamp is a genuine Korea made product following Energy-saving and Eco-friendly policy, it should be appreciated as one of the best $CO^2$ reduction Green product.

휴대용 방폭형 작업등의 경량화 연구 (Development of a Light Weight Hand Lamp of Explosion-Proof Type)

  • 최상원;이관형;김명섭;임의수
    • 한국산업안전학회:학술대회논문집
    • /
    • 한국안전학회 1997년도 추계 학술논문발표회 논문집
    • /
    • pp.135-142
    • /
    • 1997
  • For lighting of dark and hazardous workplaces such as compartments of ships under construction, workers should use hand lamps of explosion-proof type. However, the heavy weight of such lamps has prevented most impatient workers from using such types of lamps extensively. In this paper, ire developed a light weight hand lamp of intrinsic safety type which reduced the weight a lot while maintaining or improving the lighting and explosion-proof function. We made a Prototype which consisted of lamp fixture and low/high frequency power supply. Testing results show that the hand lamp meets well all the explosion-proof testing requirements of the Korea Industrial Safety Corporation.

  • PDF