• Title/Summary/Keyword: Safety Door

Search Result 327, Processing Time 0.023 seconds

Feasibility analysis of RPSD(Rope type Platform Safe Door) on the simulation (시뮬레이션을 통한 로프타입 상하개폐식 승강장 안전문 적용성 검토)

  • Kang, Hee-Chan;Kim, Hyun;Chung, Younshik
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.12 no.2
    • /
    • pp.22-29
    • /
    • 2013
  • The platform safety door is difficult to install in platform because the doors of railway vehicles and existing Passenger Safety doors should be alined. To be able to solve this problem, we propose the use of Rope Type Platform Safe Door (RPSD) which is a vertically retractable platform that is designed to close from top to bottom. This platform has installed safety gate pillars at intervals of 20-40 m which accommodates different types of train regardless of train length, gate opening and location. In this paper, we reviewed the application of existing PSD and RPSD in various train stops in Seoul Gyeongbu Line platform. The results of the review showed that the existing PSD may cause problem in construction, safety and cost efficiency. The use of RPSD however shows that minimal problems will be encountered.

Allocation of Safety Integrity Level for Railway Platform Screen Door System considering Semi-Quantitative Risk Reduction Factor (반 정량적 리스크 저감 요소를 고려한 철도 승강장 스크린 도어시스템의 안전 무결성 수준 할당)

  • Song, Ki Tae;Lee, Sung Ill
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.4
    • /
    • pp.156-163
    • /
    • 2016
  • There exists required safety integrity level (SIL) to assure safety in accordance with international standards for every electrical / electronics / control equipment or systems with safety related functions. The SIL is allocated from lowest level (level 0) to highest level (level 4). In order to guarantee certain safety level that is internationally acceptable, application of methodology for SIL allocation and demonstration based on related international standards is required. However, the theoretical and practical study for safety integrity level is barely under way in the domestic railway industry. This research studied not only the global process of SIL allocation to guarantee safety in accordance with international standards for safety related equipment and system, but the quantitative methodology based on international standard and the semi-quantitative methodology as alternative way for SIL allocation. Specifically, the systematic SIL allocation for platform screen door system of railway is studied applying the semi-quantitative methodology in order to save much time and effort compared to quantitative method.

Interlocked control and interface safety between train door and PSD (열차 출입문과 PSD간 연동제어 및 인터페이스 안전성 확보)

  • Kim, Kyoung-Shik;Choi, Jong-Mook;Lee, Jong-Seong;Yoo, Sung-Ho
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.249-254
    • /
    • 2007
  • A PSD which cooperates with train door provides safety and convenience for passengers. In order to cooperate with train door, the PSD should interface between the PSD control system and the control units of train door. This interface is generally performed in signaling system(ATC/ATO), however, the lines which don't have the interface functionality in the signaling system, it is required to have additional "PSD inter face system" to communicate between train and PSD. In this paper, we propose a safe PSD interface methodology by discussing interlocked control between train door and PSD, recognition of accuracy stop point, troubleshooting logic and log of troubles and driver panel which are adopted in Inchon line1.

  • PDF

Numerical Analysis on Features of Airflow through Open Door in Pressure Differential System (급기가압 제연시스템의 방연풍속 형성특성에 대한 수치해석적 분석)

  • Kim, Jung-Yup;Rie, Dong-Ho;Kim, Ha-Young
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.463-468
    • /
    • 2008
  • The fact that the major cases of life casualties are from smoke in the fire accidents and the expected steep increase of skyscrapers, huge spaces, multiplexes and huge scaled underground spaces demand establishment of efficient smoke countermeasure. In pressure differential systems for smoke management, the speed of airflow through open door between accommodation and lobby should be maintained over 0.5m/s on the whole area of door to prevent smoke from infiltrate into evacuation root when the door is open for refuge. The numerical analysis on features of airflow through open door are carried out and the results are presented.

  • PDF

A Study on the Collision Detection for Smart Door by Disturbance Observer (외란관측기를 이용한 스마트도어의 충돌감지에 관한 연구)

  • Park, Min-Kyu;Sung, Kum-Gil;Lee, Byungsoo
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.4
    • /
    • pp.31-36
    • /
    • 2011
  • Smart Door(SD) is a human friendly power-assisted door system for passenger car doors. It offers comfort and safety to passengers and drivers by supplying additional power. In this study, dynamic system model and the equation of motion derivation are derived. And we propose the disturbance observer based collision detection algorithm for safety when opening the door. A disturbance caused by collision has a fast response compared to a friction, uncertainties and so on. The main idea this study is to estimate a variation of disturbance for stably and effectively detecting a collision. In order to evaluate a performance of collision detection, an experiment set up is constructed. The experimental results validate the usefulness of the proposed collision detection algorithm.

Estimating Door Open Time Distributions for Occupants Escaping from Apartments

  • Hopkin, Charlie;Spearpoint, Michael;Hopkin, Danny;Wang, Yong
    • International Journal of High-Rise Buildings
    • /
    • v.10 no.1
    • /
    • pp.73-83
    • /
    • 2021
  • The door open time, resulting from occupants evacuating from apartments, is an important parameter when assessing the performance of smoke ventilation systems in high-rise apartment buildings. However, the values recommended in UK design guidance appear to have limited substantiation. Monte Carlo simulations have been carried out considering variabilities in door swing time, flow rate and number of occupants. It has been found that the door open time can be represented by a lognormal distribution with a mean of 6.6, 8.7 and 11.1 s and a standard deviation of 1.7, 3.2 and 4.7 s for one, two and three-bedroom apartments, respectively. For deterministic analyses, it is proposed that the 95th percentile values may be adopted in line with recommended practice for other fire safety design parameters such as fuel load density and soot yield, giving door open times of 10 s to 19 s, depending on the number of bedrooms.

Allocation of Safety Integrity Level for Railway Platform Screen Door System based on Consequence Severity and Risk Graph (결과 심각도 및 리스크 그래프에 기반한 철도 승강장 도어시스템의 안전 무결성 수준 할당)

  • Song, Ki Tae;Lee, Sung Ill
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.6
    • /
    • pp.164-173
    • /
    • 2015
  • There exists required safety integrity level (SIL) to assure safety in accordance with international standards for every electrical / electronics / control equipment or systems with safety related functions. The SIL is allocated from lowest level (level 0) to highest level (level 4). In order to guarantee certain safety level that is internationally acceptable, application of methodology for SIL allocation and demonstration based on related international standards is required. However, application standard differs from every industry in domestic or international for application on mythology for allocation and demonstration of SIL. Application or assessment is not easy since absence on clear criteria or common definition. This research studied not only fundamental concept of SIL required to guarantee safety in accordance with international standards for safety related equipment and system, but different types of methodologies for SIL allocation. Specifically, SIL allocation for Platform Screen Door system of railway is studied applying methodology of severity of accidents and risk graph among different methodologies for SIL allocation.

Evaluation of Out-door Fitness Safety in the Korea - TUV Standards Applied - (국내 야외 운동기구 안전성 평가에 관한 연구 - TUV 기준을 적용하여 -)

  • Kim, Yeong-Ha;Hwang, Sun-Ju;Park, Seung-Burm
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.41 no.5
    • /
    • pp.46-56
    • /
    • 2013
  • This research prepared safety standard for out-door fitness and this research's purpose is to evaluate and investigate safety condition for out-door fitness which was distributed in domestic residence by applying TUV standard which evaluate product's safety inspection. We choose twelve companies which have many sales' amount and investigated for ten out-door fitness which have high consumer preferences. As a result of that, the ratio of successful applicants for safety evaluation was 55.1%. The terms desired was evaluated highly in safety for out-door fitness's fixing condition. However, the terms desired was evaluated lowly in safety for movable condition. Fitness equipment which has high consumer preferences was compared lowly than other equipment in safety part. It was analyzed that there was no difference in safety evaluation according to manufacturing company. So, it is necessary to prepare safety standard by establishing law in order to prevent accident while they are using because we cannot think that fitness equipments which was distributed in domestic area have high safety. We think that preparing safety standard can influence on preventing accident and reinforcing out-door fitness manufacturing companies' competitive.

Study on Disaster Prevention in Case of Fire at Subway Platform with Platform Screen Door

  • Rie, Dong-Ho;Yoon, Sung-Wook;Ko, Jae-Woong;Lee, Keun-Oh
    • International Journal of Safety
    • /
    • v.4 no.2
    • /
    • pp.36-42
    • /
    • 2005
  • A study on fire phenomena in a subway transit mass station has been carried out as a part of disaster prevention plan at the subway station. The ventilation facilities installed in both the platform and the trackway are designed to convert into a smoke exhaust system in emergency situation, creating an environment necessary for evacuation. 3 dimensional Numerical Simulations based on the CFD are carried out using a simulation tool, Fire Dynamic Simulator. Total of six different cases are made and performances are compared each other to find optimal vents operation to ensure safer environment for evacuation at the platform area considering the installation of platform screen door.

Behavior Analysis of Elevator Door (엘리베이터 도어의 거동해석)

  • Lee, Jong-Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.5
    • /
    • pp.991-994
    • /
    • 2007
  • Recently, there has been major issue in safety of elevator. In the view of safe management of elevator, the corresponding research must be done since accidents related elevator include not only actual accident but also possible accident in order to protect user from dangerousness. This research aims to seek an analytical solution for safety apparatus which caused accident again and again among dangerous factors of an elevator. In order to assure safety of door, ANSYS, a commercial software was applied and evaluate safety qualitatively by calculating stress and strain deformed under the loads of 40 to 100kg.

  • PDF