The platform safety door is difficult to install in platform because the doors of railway vehicles and existing Passenger Safety doors should be alined. To be able to solve this problem, we propose the use of Rope Type Platform Safe Door (RPSD) which is a vertically retractable platform that is designed to close from top to bottom. This platform has installed safety gate pillars at intervals of 20-40 m which accommodates different types of train regardless of train length, gate opening and location. In this paper, we reviewed the application of existing PSD and RPSD in various train stops in Seoul Gyeongbu Line platform. The results of the review showed that the existing PSD may cause problem in construction, safety and cost efficiency. The use of RPSD however shows that minimal problems will be encountered.

기존의 승강장 안전문은 철도 차량의 출입문과 승강장 안전문이 1:1로 매칭이 되어야만 사용이 가능하기 때문에 다양한 열차가 정차하는 승강장에는 적용이 매우 어렵다. 이러한 문제를 해결하기 위해 제시된 승강장 안전문이 로프타입 상하개폐식 승강장 안전문(Rope type Platform Safe Door : RPSD)이다. 로프타입 상하개폐식 승강장 안전문은 승강장 안전문이 위에서 아래로 닫히고 승강장 안전문의 상하 이동을 위한 기둥은 20~40m 간격으로 설치되기 때문에 열차의 길이 및 출입문 위치, 출입문 개수와 상관없이 다양한 열차가 혼용하여 사용할 수 있도록 설계되었다. 본 논문에서는 다양한 열차가 정차하는 영등포역 일반열차 승강장에 기존 PSD 및 RPSD의 적용이 가능한지를 시뮬레이션을 통해 검토하였다. 검토결과 기존의 PSD는 시공, 안전, 비용상 문제가 발생할 것으로 파악되었으나, RPSD의 경우에는 적용에 큰 문제가 없는 것으로 나타났다.

Keywords

References

  1. S. W. Kim, K. C. Seong, B. K. Kang, "The Study of Introducing the Screen Door in Subway Station" Korea institute of healthcare architecture journal, vol. 10 no. 2, 2004
  2. J. K. Kim, "A Study on the improvement in safety after the installation pf Platform Screen Door", Seoul national university of science and technology, Paper of masters degree, 2008
  3. J. S. Kim, J. G. Shon, "Development of High Reliability Monitoring and Control System for Platform Screen Door", Korea institute of electrical engineers journal, Vol. 59 No.2, 2010
  4. C. H. Woo, J. G. Son, J. S. Kim, "The proto-type manufacturing and field application of the DCU for PSD", Korea institute of electrical engineers The 42th conference, 2011
  5. S. H. Lee, "The introduction of platform screen door in the subway station", Seoul national university of science and technology, Paper of masters degree, 2004
  6. Korail, "Detailed rules of train driving", Article 7, 2005
  7. Hyundai elevator co., "Introduce of PSD control method", 2006
  8. PTV-Vision. VISSIM 5.40 User Manual, PTV AG, 2012
  9. PTV-Vision. VISSIM 5.40-07 COM Interface Manual, PTV AG, 2012
  10. Doosan encyclopedia 'platform screen door', Mar., 10, 2013