• Title/Summary/Keyword: Safety Distance

Search Result 1,587, Processing Time 0.026 seconds

Development of Portable Cable Fault Detection System with Automatic Fault Distinction and Distance Measurement (자동 고장 판별 및 거리 측정 기능을 갖는 휴대용 케이블 고장 검출 장치 개발)

  • Kim, Jae-Jin;Jeon, Jeong-Chay
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.10
    • /
    • pp.1774-1779
    • /
    • 2016
  • This paper proposes a portable cable fault detection system with automatic fault distinction and distance measurement using time-frequency correlation and reference signal elimination method and automatic fault classification algorithm in order to have more accurate fault determination and location detection than conventional time domain refelectometry (TDR) system despite increased signal attenuation due to the long distance to cable fault location. The performance of the developed system method was validated via an experiment in the test field constructed for the standardized performance test of power cable fault location equipments. The performance evaluation showed that accuracy of the developed system is less than 1.34%. Also, an error of automatic fault type and location by detection of phase and peak value through elimination of the reference signal and normalization of correlation coefficient and automatic fault classification algorithm not occurred.

Fatigue Measurement by Lifting Index

  • Kim Dae-Sik;Kang Kyong Sik
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2000.11a
    • /
    • pp.187-193
    • /
    • 2000
  • The purpose of this study was to reduce the chronical low back pain for the manual material handlers. The objectives of this study was to: (1) examine lifting variables, (2) analyze collected data, and (3) suggest lifting redesign recommendations in workplace. The data were collected in A company, manufactures various paints in Si-Wha industrial complex, Kyunggi-Do. It was found that Sb(horizontal distance), Sc(vertical distance), 54(travelling distance) and Sf(frequency) were significant at the 0.01 level and Sa(weight) was significant at the 0.05 level.

  • PDF

A Study on the Prevention of Forklift Accidents in Distribution Center by Using AHP Techniques (AHP기법을 활용한 통한 물류센터 내 지게차사고 예방에 관한 연구)

  • Byung Hyun Chung;Ki Hong Kim
    • Journal of the Korea Safety Management & Science
    • /
    • v.26 no.3
    • /
    • pp.115-121
    • /
    • 2024
  • The forklift carry cargo and move to various places. When a forklift moves to various places, a forklift accident occurs due to a number of factors,such as speed, safe distance. Forklift accidents occur at the logistic site and there are many studies on the causes of accident such as jamming, falling, collisions, etc. However, safety operation for accident prevention is necessary before operating a forklift. Pre-accident safety precautions may prevent accidents. In this study, precautionary factors for safe operation were analyzed to prevent forklift safety accidents through the AHP technique. As a result of the study showed that safety management was the priority in the terminal group and the logistics warehouse group.

Measurement and Analysis of Ground Impedance according to Arrangement of Auxiliary Probe around Ground Grid (접지 그리드에서의 보조전극 배치에 따른 접지임피던스 측정 및 분석)

  • Gil, Hyoung-Jun;Shong, Kil-Mok;Kim, Young-Seok;Kim, Chong-Min
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.4
    • /
    • pp.46-50
    • /
    • 2015
  • This paper describes the measurement and analysis of ground impedance according to arrangement of auxiliary probe around ground grid using the fall-of-potential method and the testing techniques to minimize the measuring errors are proposed. The fall-of-potential method involves passing a current between a ground electrode and a current probe, and then measuring the voltage between a ground electrode and a potential probe. To minimize interelectrode influences due to mutual resistances, the current probe is a generally placed at a substantial distance from the ground electrode under test. In order to analyze the effects of ground impedance due to the arrangement of auxiliary probe and frequency, ground impedances were measured in case that the arrangements of auxiliary probe were straight line, perpendicular line, and horizontal line. The distance of current probe was located from 10[m] to 200[m] and the measuring frequency was ranged from 55[Hz] to 513[Hz]. As a consequence, the ground impedance increases with increasing the distance from the ground electrode to the point to be tested, but the ground impedance decreases with increasing the frequency.

Planning for Safety Control on LPG Distribution Depot (LPG 판매업소의 위험성 제어계획)

  • 노삼규;전성우;강태희;서영민
    • Fire Science and Engineering
    • /
    • v.12 no.4
    • /
    • pp.21-30
    • /
    • 1998
  • The safety of LPG vessel storage has been simply designed and controled with blast wave barrier structure concept regardless of its quantity or hazardous situation. The limit of regal controls on LPG vessel storage need to be identified in terms of safety buffer distance from LPG explosion. The level of overpressure effect and heat radiation to the neighbouring structure and human activity required to be estimated to find the gap between existing controls on such storage. PHAST and IAEA manual for risk rankings and assessment had been applied to get the required safety distance for neighbouring facilities, Japanese legal control for such facilities were also investigated. To this context the issues on LPG vessel storage required additional safety distance between existing blast wave barrier structure and safety separation distances.

  • PDF

Toxic Concentration(T-LOC) Endpoint Distance Study for Fire Brigade Protection in Response to Chemical Accidents (화학사고 초기대응 소방대 보호를 위한 독성농도(T-LOC) 끝점거리 연구)

  • Jong Chan Yun;Chul Hee Cho;Jeong Hun Won
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.6
    • /
    • pp.60-71
    • /
    • 2023
  • The purpose of this study is to propose a quantitative toxicity endpoint distance suitable for the initial response of firefighters by comparing and analyzing the commonly applied toxic level of concern (T-LOC), specifically emergency response planning guidelines (ERPG), acute exposure guideline levels (AEGL), and immediately dangerous to life or health (IDLH). This is to protect the fire brigade, which responds to toxic chemical accidents first during the golden time. Using areal locations of hazardous atmospheres, a damage prediction program, the amount of leakage for both acidic and basic substances, along with the endpoint distance, were analyzed for alternative accident and worst-case accident scenarios. The results showed that the toxicity endpoint distance, serving as a compromise between Level-3 and Level-2 of T-LOC, was longer than ERPG-3 and shorter than ERPG-2 with IDLH, while its values were analyzed in the order of ERPG-2, AEGL-2, IDLH, AEGL-3, and ERPG-3. It is suggested that the application of IDLH in an emergency (red card) and ERPG-2 endpoint distance in a non-emergency (non-red card) can be utilized for the initial response of the fire brigade.

A Study on Minimum Separation Distance for Aboveground High-pressure Natural Gas Pipelines (지상 고압 천연가스 배관의 최소 이격거리 기준에 관한 연구)

  • Lee, Jin-Han;Jo, Young-Do
    • Korean Chemical Engineering Research
    • /
    • v.57 no.2
    • /
    • pp.225-231
    • /
    • 2019
  • In Korea, the minimum separation distance between aboveground high-pressure natural gas pipeline and buildings is regulated by Korea gas safety (KGS) code. In this paper, The technical backgrounds for the revision of the KGS code related to the minimum separation distance was presented. A consequence-based approach was adopted to determine the minimum separation distance by a reasonable accident scenario, which was a jet fire caused by the rupture of one inch branch line attached the gas pipeline. Where, the higher thermal radiation flux threshold was selected for workers in industrial area than for people in non-industrial area, because the workers in industrial area were able to escape in a shorter time than the people in public. As result of consequence analysis for the accident scenario, we suggested the KGS code revision that the minimum separation distances between high-pressure natural gas pipeline installed above ground and buildings should be 30 meter in non-industrial area and 15 meter in industrial area. The revised code was accepted by the committee of the KGS code and now in effect.

A Study on the Minimum Safety Distance between Navigation Vessels based on Vessel Operator's Safety Consciousness (선박운항자 안전 의식에 기초한 선박통항 최소 이격거리에 관한 연구)

  • Park, Young-Soo;Jeong, Jae-Yong;Kim, Jong-Sung
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.16 no.4
    • /
    • pp.401-406
    • /
    • 2010
  • Vessel Operator has been navigating with subjective sate distance in accordance with night & daytime, fore & aft, port & stbd abeam and visibility situation. This sate distances may different depending on inside & outside harbor limit, current, wind and visibility situation. By now, the concept of proper sate distance between navigating vessels has been adopted in Korea, using the early 1980's foreign data. And the safe distance is being used with the same value without any consideration of inside & outside harbor and the kind of vessel. So it is necessary to evaluate or search proper distance concept based on different sate consciousness of Korean manners. This paper aims to develop the basic model for marine traffic evaluation and the new model of marine traffic congestion. Also this paper proposes the basic control guideline of vessel traffic service center. The result of this study showed that minimum sate distance should be 4.4L forward, 3.1L aft and 26L abeam in case of good visibility in daytime, considering various parameters such as visibility, day and night. Some differences Here found between the existing minimum sate distance and the new minimum sate distance derived from the result of this study.