The Development of UV-IR Combination Flame Detector (UV-IR 복합형 화재감지장치 개발)

  • 이복영;권오승;정창기;박상태
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.1
    • /
    • pp.1-8
    • /
    • 2001
  • All objects emit thermal radiation and this radiation is the basis of the techniques used to detect flames. The usual phenomena occurring in the initial stage of the fire are generally invisible products of a combustion and visible smoke. Liquid or gaseous materials do not undergo a smoldering stage so that fires develop very rapidly. Also, the heat generated by the initial flames is usually not sufficient to activate a heat detector. In this case the most effective criterion for automatic fire detection is the flame. According to the fire regulation of korea, the compulsory standard provided that a flame detector shall be installed in a place that the attachment height of detector is higher than 20 m, chemical plants, hangar, refinery, etc.. The results of the research and development are discriminated between a flame and other radiant emitters, developed a UV detector tube contains an inert gas which absorbs UV radiation, developed PZT pyroelectric element is based on the use of photovoltanic cell, developed IR band-pass filter that only allow a 4.3 $\mu\textrm{m}$ radiation wavelength to reach the sensors and developed UV-IR combination flame detector combined into a single detection device.

  • PDF

A Study on the X-Band Active Radar Reflector for safety at the Sea (해상 안전을 위한 X밴드 능동형 레이더 반사기에 관한 연구)

  • 정종혁;김남호;양규식
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.3 no.4
    • /
    • pp.849-858
    • /
    • 1999
  • There are several improved designs of passive radar reflector available, but their performance is ultimately limited by the cross-section area and this is governed by the size of the buoy and the acceptable windage. Therefore it is needed to investigate the low-cost, low power, a active device that can be improve the reliability of response. Active Radar Reflector(AAR) consists of a microwave amplifier with separate receive and transmit antennas. It is a device which automatically transmits a signal in response to an interrogating signal received. It was intended to improve the consistency of the radar return from the buoy and the small craft, particularly in poor sea conditions. And it directly improves safety of navigation at sea.

  • PDF

Distributed Control of DC Servo Motor on LonWorks-IP Virtual Device Network for Predictive and Preventive Maintenance (LonWorks-IP 가상 디바이스 네트워크상에서 예지 및 예방보전을 위한 DC 서보모터의 분산제어)

  • Song, Ki-Won
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.4 s.76
    • /
    • pp.25-32
    • /
    • 2006
  • LonWorks over IP(LonWorks-IP) virtual device network(VDN) is an integrated form of LonWorks device network and IP data network. In especially real-time distributed servo applications on the factory floor, timely response is essential for predictive and preventive maintenance. The time delay in servo control on LonWorks-IP based VDN has highly stochastic nature. LonWorks-IP based VDN induced transmission delay deteriorates the performance and stability of the real-time distributed control system and can't give an effective preventive and predictive maintenance. In order to guarantee the stability and performance of the system, and give an effective preventive and predictive maintenance, LonWorks-IP based VDN induced time-varying uncertain time delay needs to be predicted and compensated. In this paper new Pill control scheme based on Smith predictor, disturbance observer and band pass filter is proposed and tested through computer simulation about position control of DC servo motor. It is shown that how can the proposed control scheme be designed to minimize the effects of uncertain varying time delay and model uncertainties. The validity of the proposed control scheme is compared and demonstrated with the comparison of internal model controllers(IMC) based on Smith predictor with and without disturbance observer.

Patch Antenna for MOB Attached on Safety Helmet (안전모에 부착하는 MOB용 패치 안테나)

  • Kim, Jaewon;Yang, Gyusik
    • Journal of Advanced Navigation Technology
    • /
    • v.20 no.1
    • /
    • pp.93-98
    • /
    • 2016
  • The purpose of this study is to design for MOB antenna attached on safety helmet using microstrip patch antenna. The patch antenna is fabricated in 0.2 mm FR-4 substrate with $64{\times}64mm$ size. The proposed antenna is based on a slot-ring design which cover Inmarsat (1.52 ~ 1.65 GHz) and GPS (1.575 GHz) frequency band. To obtain the optimized parameters, HFSS simulator is used, and antenna is designed by optimized parameters. After antenna was etched, SMA connector was attached to the microstrip feeding line and the result between antenna simulation and measurement was analyzed. Proposed antenna is satisfied the -10 dB bandwidth requirement while simultaneously covering the 1.53 ~ 1.65 GHz.

Effect of Trichloroethylene on the Induction of Rat Liver Microsomal Enzymes

  • Chang, Sung-Keun;Jeong, Hyo-Seok;Chai, Se-Ok;Kim, Ki-Woong;Park, Sang-Shin
    • BMB Reports
    • /
    • v.30 no.4
    • /
    • pp.237-239
    • /
    • 1997
  • The effects of trichloroethylene (TRI) on the induction of cytochrome P-450 (CYP) and several other related enzymes in Sprague Dawley rats were investigated Rats were treated with TRI 150. 300. 600 mg/kg body weight in corn oil intra peritoneally once a day for 2 days. The total contents of microsomal CYP and cytochrome $b_5\;(b_5)$ decreased with the increase of TRI concentration. but the activity of p-nitrophenol hydroxylase increased with the increase of TRI dosage (p<0.05). Western blot analysis which utilized monoclonal antibodies against CYP2E1 also showed a significant increase in the CYP2E band density. The increase of the activity of pentoxyresolufin-O-deethylase also was observed with the TRI treatment (p<0.05) although there was no significant increase in the cytochrome CYP2B1/2 in Western blotting The TRI did not affect the induction of aryl hydrocarbon hydroxylase. These findings suggest that the CYP2E1 is the primary enzyme which could be induced by TRI treatment in rats.

  • PDF

2D Image Construction from Low Resolution Response of a New Non-invasive Measurement for Medical Application

  • Hieda, Ichiro;Nam, Ki-Chang
    • ETRI Journal
    • /
    • v.27 no.4
    • /
    • pp.385-393
    • /
    • 2005
  • This paper presents an application of digital signal processing to data acquired by the radio imaging method (RIM) that was adopted to measure moisture distribution inside the human body. RIM was originally developed for the mining industry; we are applying the method to a biomedical measurement because of its simplicity, economy, and safety. When a two-dimensional image was constructed from the measured data, the method provided insufficient resolution because the wavelength of the measurement medium, a weak electromagnetic wave in a VHF band, was longer than human tissues. We built and measured a phantom, a model simulating the human body, consisting of two water tanks representing large internal organs. A digital equalizer was applied to the measured values as a weight function, and images were reconstructed that corresponded to the original shape of the two water tanks. As a result, a two-dimensional image containing two individual peaks corresponding to the original two small water tanks was constructed. The result suggests the method was applicable to biomedical measurement by the assistance of digital signal processing. This technique may be applicable to home-based medical care and other situations in which safety, simplicity, and economy are important.

  • PDF

A Study on the Construction of Vibration Measurement System and Evaluation of Vibration Related Habitability on the Training Ship (진동계측 시스템의 구축과 실습선 내 거주성에 미치는 진동 평가에 관한 연구)

  • Nam, Taek-Kun;Kim, Deug-Bong;Lee, Don-Chcol
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.16 no.1
    • /
    • pp.135-140
    • /
    • 2010
  • Vibration on the ship was generated mainly by main engine and propeller. The vibration which is generated from the ship has an effect on durability of ship's machinery and it also has an evil influence on the working conditions for crew. In this research, vibration measurement system to measure ship's vibration was built and vibration signals using acceleration sensors were measured from an accomodation space of training ship. An evaluation of vibration with regard to habitability was also discussed and the evaluation process followed the guidelines ISO6954:2000E.

Preliminary strong ground motion simulation at seismic stations within nuclear power plant sites in South Korea by a scenario earthquake on the causative fault of 2016 Gyeongju earthquake

  • Choi, Hoseon
    • Nuclear Engineering and Technology
    • /
    • v.54 no.7
    • /
    • pp.2529-2539
    • /
    • 2022
  • Stochastic and an empirical Green's function (EGF) methods are preliminarily applied to simulate strong ground motions (SGMs) at seismic stations within nuclear power plant (NPP) sites in South Korea by an assumed large earthquake with MW6.5 (scenario earthquake) on the causative fault of the 2016 Gyeongju earthquake with MW5.5 (mainshock). In the stochastic method, a ratio of spectral amplitudes of observed and simulated waveforms for the mainshock is assumed to be an adjustment factor. In the EGF method, SGMs by the mainshock are simulated assuming SGMs by the 2016 Gyeongju earthquake with MW5.0 (foreshock) as the EGF. To simulate SGMs by the scenario earthquake, a ratio of fault length to width is assumed to be 2:1 in the stochastic method, and SGMs by the mainshock are assumed to be EGF in the EGF method. The results are similar based on a bias of the simulated response spectra by the two methods, and the simulated response spectra by the two methods exceeded commonly standard design response spectra anchored at 0.3 g of NPP sites slightly at a frequency band above 4 Hz, but considerable attention to interpretation is required since it is an indirect comparison.

A Study on the Analysis of Fire Mechanisms in Electronic Products due to Failure and Malfunction of Thermostats Through Fire Cases and Reproduction Experiments (화재사례 및 재현실험을 통한 온도조절장치 고장 및 오동작으로 인한 전자제품 화재 메커니즘 분석)

  • Jeong-il Lee;Jong-Hwa Im
    • Journal of the Korea Safety Management & Science
    • /
    • v.26 no.1
    • /
    • pp.31-38
    • /
    • 2024
  • In this paper, as there are many cases of fires occurring due to the failure or inoperability of the thermostat of electronic products, the purpose is to test and analyze the risks and probabilities through fire cases and reproduction experiments, and suggest countermeasures. Among electronic products, water purifiers are composed of a refrigerant system with a compressor to make cold water, a heating device to make hot water, and an electric device used as an energy source. Due to the nature of the water purifier manufacturing, these devices are subject to a lot of moisture and dust. etc. exist in large quantities and use electrical energy, so there is a possibility of fire due to short circuit in the wire, electrical abnormal overheating (tracking phenomenon) in the thermostat, electronic board, starting relay, etc., and overheating of the heating device (Band Heater). there is. Therefore, in order to prevent fires from these devices, a system to remove foreign substances inside the water purifier is necessary, the use of heat-resistant (fire-resistant) wires for electrical devices is essential, and the use of non-combustible materials (semi-combustible materials) for each part is necessary to prevent fire. The risk must be eliminated through prevention and combustion expansion prevention devices.

CD11b as a Biomarker for Canine Systemic Inflammatory Response Syndrome and Sepsis (개 전신성염증반응증후군 및 패혈증의 진단적 표지자로서 CD11b의 활용)

  • Yu, Do-Hyeon;Noh, Dong-Ho;Song, Ru-Hui;Kim, Jun-Hwan;Lee, Da-Mi;Kim, Sue-Hee;Park, Chul;Park, Jin-Ho
    • Journal of Veterinary Clinics
    • /
    • v.27 no.6
    • /
    • pp.627-630
    • /
    • 2010
  • The aim of this study is to investigate neutrophil activation markers among canine ICU (intensive care unit) control, systemic inflammatory response syndrome (SIRS) and sepsis. These markers include WBC (white blood cells), platelets counts, blood film examination (neutrophilic band to segmentation ratio and neutrophilic degenerative changes), and flow cytometric analysis (CD11b expression of neutrophils). As a result, the mean CD11b fluorescence intensity of neutrophils and the neutrophilic degenerative change scores were both significantly higher in sepsis group (P<0.05). In addition, mortality was also found to be correlated with the up-regulation of CD11b expression in circulating neutrophils. This study demonstrates that CD11b expression of neutrophils could be more a reliable biomarker to predict prognosis in ICU patients than traditional blood film examination according to this study.