• Title/Summary/Keyword: SS(Stainless steel)

Search Result 156, Processing Time 0.024 seconds

A study on the corrosion characteristics of weldment and harmful pollutants in welding process (용접부의 부식특성과 용접공정에서 발생되는 유해물질에 관한 연구)

  • Yun, Yeong-Muk;Lee, Cheol-Gu
    • Proceedings of the KWS Conference
    • /
    • 2007.11a
    • /
    • pp.279-281
    • /
    • 2007
  • This paper reviews corrosion characteristics of welded in the area of 409 Stainless Steel, Aluminium and Carbon steel. The effects of alloying elements and welding conditions on the intergranular-corrosion in weldment of the 409 stainless steels(SS) were investigated. And then this was to investigate factors affecting the composition and concentrations of fumes generated from various types of welding processes. It is also suggested that the direct relationship between the corrosion characteristics and welding type be clarified by experimental and analytical results.

  • PDF

Stress Corrosion Cracking of Heat Exchanger Tubes in District Heating System

  • Cho, Sangwon;Kim, Seon-Hong;Kim, Woo-Cheol;Kim, Jung-Gu
    • Corrosion Science and Technology
    • /
    • v.18 no.2
    • /
    • pp.49-54
    • /
    • 2019
  • The purpose of this paper is to present failure analysis, of the heat exchanger tube in a district heating system. SS304 stainless steel is used, as material for the heat exchanger tube. The heat exchanger operates in a soft water environment containing a small amount of chloride ions, and regularly repeats operation and standstill period. This causes concentration of chloride ions on the outer surface of the tube, as well as repeat of thermal expansion, and shrinkage of the tube. As a result of microscopic examination, cracks showed transgranular as well as branched propagation, and many pits were present, at the initiation point of each crack. Energy disperstive spectroscopy analysis showed Fe and O peak, as well as Cl peak, meaning that cracks were affected by Cl ion. Failure of the tube was caused by chloride-induced stress corrosion cracking by thermal stress, high temperature, and localized enrichment of chloride ions.

Evaluation of Microstructure and Mechanical Properties in 17-4PH Stainless Steels Fabricated by PBF and DED Processes (PBF와 DED 공정으로 제조된 17-4PH 스테인리스 강의 미세조직 및 기계적 특성 평가)

  • Yoon, Jong-Cheon;Lee, Min-Gyu;Choi, Chang-Young;Kim, Dong-Hyuk;Jeong, Myeong-Sik;Choi, Yong-Jin;Kim, Da-Hye
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.2
    • /
    • pp.83-88
    • /
    • 2018
  • Additive manufacturing (AM) technologies have attracted wide attention as key technologies for the next industrial revolution. Among AM technologies using various materials, powder bed fusion (PBF) processes and direct energy deposition (DED) are representative of the metal 3-D printing process. Both of these processes have a common feature that the laser is used as a heat source to fabricate the 3-D shape through melting of the metal powder and solidification. However, the material properties of the deposited metals differ when produced by different process conditions and methods. 17-4 precipitation-hardening stainless steel (17-4PH SS) is widely used in the field of aircraft, chemical, and nuclear industries because of its good mechanical properties and excellent corrosion resistance. In this study, we investigated the differences in microstructure and mechanical properties of deposited 17-4PH SS by PBF and DED processes, including the heat treatment effect.

A Study of the Heat Treatment Effect on the Fatigue Crack Growth Behavior in Dissimilar Weld Metal Joints of SA508 Low-Carbon Steel and AISI316 Austenitic Stainless Steel (SA508 저탄소강과 AISI316 오스테나이트강의 이종 용접부 피로균열 성장 거동에 미치는 열처리 영향 연구)

  • Kim, Chung-Seok
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.3
    • /
    • pp.16-21
    • /
    • 2018
  • The effect of heat treatment on the fatigue crack growth behavior in welded joints between the heat-affected zone (HAZ) of SA 508 Cl.3 low-alloy steel and HAZ of AISI 316L stainless steel is investigated. When the crack propagates across SA 508 Cl.3 or AISI 316L SS and HAZ into the weldment, the fatigue crack growth rate (FCGR) in the HAZ region does not change or decrease despite the increase in stress intensity factor ${\Delta}K$. The residual stress at the HAZ region is more compressive than that at the base Δ materials and weldment. The effect of the welding residual stress on the crack growth behavior is determined by performing a residual stress relief heat treatment at $650^{\circ}C$ for 1h and subsequent furnace cooling. The FCG behavior in the HAZ region in the as-welded specimen and the residual stress relief heat-treated specimen is discussed in terms of the welding residual stress.

Contact resistance characteristics of 2G HTS coils with metal insulation

  • Sohn, M.H.;Ha, H.;Kim, S.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.20 no.4
    • /
    • pp.26-30
    • /
    • 2018
  • The turn-to-turn contact resistance of 2G high temperature superconducting (HTS) coils with metal insulation (MI) is closely related to the stability of the coils, current charging rate and delay time [1]. MI coils were fabricated using five kinds of metal tapes such as aluminum (Al) tape, brass tape, stainless steel (SS) tape, copper (Cu)-plated tape and one-sided Cu-plated SS tape. The turn-to-turn contact surface resistances of co-winding model coils using Al tape, brass tape, and SS tape were 342.6, 343.6 and $724.8{\mu}{\Omega}{\cdot}cm^2$, respectively. The turn-to-turn contact resistance of the model coil using the one-sided Cu-plated SS tape was $ 248.8{\mu}{\Omega}{\cdot}cm^2$, which was lower than that of Al and brass tape. Al or brass tape can be used to reduce contact resistance and improve the stability of the coil. Considering strength, SS tape is recommended. For strength and low contact resistance, SS tape with copper plating on one side can be used.

Bone Ingrowth and Enhancement of Bone Bonding Strength at Interface between Bone and HA Coated Stainless Steel (HA 코팅된 스테인레스강과 뼈의 계면에서의 경조직 성장 및 결합력 향상)

  • Kim, C.S.;Kim, S.Y.;Kim, D.H.;Khang, G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.133-136
    • /
    • 1996
  • We investigated how hydroxyapatite (HA) coating onto a porous super stainless steel (S.S.S, 22Cr-20Ni-6Mo-0.25N) affects bone ingrowth in a dog transcortical femoral model. Implants were histologically evaluated after 4 and 48 weeks of implantation, and the bone bonding strength at the bone/implant interface was examined by employing the pull-out test. The direct osseous tissue bonding onto the HA-coated S.S.S was observed, but the uncoated stainless steels had thin fibrous tissue layers. The mean interface strength of the HA-coated S.S.S was 1.5 and 2.5 times greater than those of the S.S.S and the 316L SS after one year of implantation, respectively. In preliminary studies, no toxic responce was observed from a cytotoxicity test of the S.S.S, having similar corrosion resistance to titanium. Our results suggest that early osteoconductive nature of HA coating may induce long term osteointegration for a bioinert substrate.

  • PDF

Inhibitory effects of ultraviolet-C light and thermal treatment on four fungi isolated from pig slaughterhouses in Korea

  • Lee, Eun-Seon;Kim, Jong-Hui;Kang, Sun Moon;Kim, Bu-Min;Oh, Mi-Hwa
    • Journal of Animal Science and Technology
    • /
    • v.64 no.2
    • /
    • pp.343-352
    • /
    • 2022
  • Pig slaughterhouses harbor high humidity because of the necessary cleaning that takes place simultaneously with slaughter, which facilitates the existence of mold. Due to the enclosed space, there are several limitations to the control of mold growth with respect to cleaning, ventilation, and drying. In this study, the prevalence of fungi was investigated in four pig slaughterhouses in Korea. Four fungi (Aspergillus niger, Penicillium commune, Penicillium oxalicum, and Cladosporium cladosporioides) were detected with the highest frequency. These four strains were subjected to various treatments to reduce their growth. The fungi were inoculated onto stainless steel (SS) chips and treated with ultraviolet (UV)-C irradiation and hot water. Individual treatments with UV-C (15, 30, 90, 150, 300, and 600 mJ/cm2), and hot water (60, 65, 70, and 83℃) were performed to sanitize the SS chips. Simultaneous cleaning with 60℃ hot water and more than 150 mJ/cm2 of UV-C reduced the fungal incidence by > 6.5 Log from 6.6-7.0 Log CFU/cm2 (initial count). Our results demonstrate that a combined treatment of UV-C and hot water is the most economical and convenient way to prevent microbiological contamination of small tools (such as knives and sharpeners) and steel surfaces in slaughterhouses.

태양전지 적용을 위한 Stainless Steel 기판의 표면처리 효과에 관한 연구

  • Lee, Yu-Jeong;Yun, Seon-Jin;Im, Jeong-Uk;Lee, Seong-Hyeon;Baek, Je-Hun;Kim, Gyeong-Bo;Park, Yeong-Jun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.404-404
    • /
    • 2011
  • 앞으로 유연성 태양전지는 빌딩 디자인에 부합하는 태양전지로서 다양하게 활용될 수 있는 매우 유망한 기술 분야이다. 얇은 스테인레스 스틸(SS) 기판은 이러한 유연성 박막태양전지의 기판으로서 중요한 장점을 가지고 있다. 250$^{\circ}C$ 이상의 고온 박막태양전지 제조 공정에서 안정하고, 부식의 염려가 없으며, 또한 기판을 통해 수분, 산소 등이 침투할 수 없기 때문에 패키징이 수월하다. 그러나 SS 기판은 표면 스크래치 등이 전혀 없도록 제조하기 어렵고, 그 위에 무기 박막을 형성할 때 adhesion 특성이 나쁜 어려움이 있다. 본 연구에서는 SS 기판 표면을 단시간 식각하거나, 졸겔 방법으로 SiO2, Al2O3의 조성을 변화시키면서 막을 형성하여 adhesion특성 변화를 연구하였다. 또한 SS 기판 처리 조건에 따라 박막태양전지 기판으로서 중요한 특성인 표면 거침도에 따른 가시광선 산란 정도를 SS 기판 상에 금속, 투명전극을 형성하여 분석하였다. 기판을 식각해서 표면을 개질하고 그 위에 Al 박막을 증착한 후 반사도를 측정하였을 때, 식각 시간을 30초에서 3분으로 증가시킴에 따라 total reflectance는 75.7%에서 66.5%로 감소한 반면, diffuse reflectance는 1.1%에서 44.8%로 증가하였다. 이러한 diffuse reflectance의 증가는 박막 태양전지의 효율을 향상시킬 것으로 기대된다.

  • PDF

Pulmonary Toxicity and Recovery from Inhalation of Manual Metal Arc Stainless Steel Welding Fumes in Rats

  • Yang, Mi-Jin;Kim, Jin-Sung;Yang, Young-Su;Cho, Jae-Woo;Choi, Seong-Bong;Chung, Yong-Hyun;Kim, Yong-Bum;Cho, Kyu-Hyuk;Lim, Chae-Woong;Kim, Choong-Yong;Song, Chang-Woo
    • Toxicological Research
    • /
    • v.24 no.2
    • /
    • pp.119-127
    • /
    • 2008
  • The objectives of this study were to examine the lung injury and inflammation caused by manual metal arc stainless steel(MMA-SS) welding fume inhalation and to evaluate the recovery process. Sprague-Dawley rats were exposed to MMA-SS welding fumes for 2 h per day in a whole-body exposure chamber, with a total suspended particulate(TSP) concentration of $51.4{\pm}2.8mg/m^3$(low dose) or $84.6{\pm}2.9mg/m^3$(high dose) for 30 days. The animals were sacrificed after 30 days of exposure as well as after a 30-day recovery period. To assess the inflammatory or injury responses, cellular and biochemical parameters as well as cytokines were assayed in the bronchoalveolar lavage fluid(BALF). MMA-SS welding fume exposure led to a significant elevation in the number of alveolar macrophages(AM) and polymorphonuclear cells(PMN). Additionary, the values of $\beta$-n-acetyl glucosaminidase($\beta$-NAG) and lactate dehydrogenase(LDH) in the BALF were increased in the exposed group when compared to controls. After 30 days of recovery from exposure, a significant reduction in inflammatory parameters of BALF was observed between the exposed and recovered groups. Slight, but significant elevations were noted in the number of AM and PMN in the recovered groups, and AM that had been ingested fume particles still remain in the lungs. In conclusion, these results indicated that welding fumes induced inflammatory responses and cytotoxicity in the lungs of exposed rats. Fume particles were not fully cleared from lungs even after a 30-day recovery period.

Corrosion Behaviors of Structural Materialsin High Temperature S-CO2 Environments

  • Lee, Ho Jung;Kim, Hyunmyung;Jang, Changheui
    • Corrosion Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.41-47
    • /
    • 2014
  • The isothermal corrosion tests of several types of stainless steels, Ni-based alloys, and ferritic-martensitic steels (FMS) were carried out at the temperature of 550 and $650^{\circ}C$ in SFR S-$CO_2$ environment (200 bar) for 1000 h. The weight gain was greater in the order of FMSs, stainless steels, and Ni-based alloys. For the FMSs (Fe-based with low Cr content), a thick outer Fe oxide, a middle (Fe,Cr)-rich oxide, and an inner (Cr,Fe)-rich oxide were formed. They showed significant weight gains at both 550 and $650^{\circ}C$. In the case of austenitic stainless steels (Fe-based) such as SS 316H and 316LN (18 wt.% Cr), the corrosion resistance was dependent on test temperatures except SS 310S (25 wt.% Cr). After corrosion test at $650^{\circ}C$, a large increase in weight gain was observed with the formation of outer thick Fe oxide and inner (Cr,Fe)-rich oxide. However, at $550^{\circ}C$, a thin Cr-rich oxide was mainly developed along with partially distributed small and nodular shaped Fe oxides. Meanwhile, for the Ni-based alloys (16-28 wt.% Cr), a very thin Cr-rich oxide was developed at both test temperatures. The superior corrosion resistance of high Cr or Ni-based alloys in the high temperature S-$CO_2$ environment was attributed to the formation of thin Cr-rich oxide on the surface of the materials.