• Title/Summary/Keyword: SRO

Search Result 34, Processing Time 0.039 seconds

Effect of social order, perch, and dust-bath allocation on behavior in laying hens

  • Wang, Yanan;Zhang, Runxiang;Wang, Lisha;Li, Jianhong;Su, Yingying;Li, Xiang;Bao, Jun
    • Animal Bioscience
    • /
    • v.35 no.2
    • /
    • pp.299-307
    • /
    • 2022
  • Objective: The objective of this study was to determine the effects of different social ranking order (SRO) and the enrichments (perch and dust-bath) allocation (EA) on behavior of laying hens in furnished cages. Methods: Total experimental period was 4 weeks. There were 216 Hy-line brown layers beak-trimmed at 1 d of age and selected randomly at 14 weeks of age from a commercial farm, and randomly divided into 36 cages with 6 hens in each cage. High enrichments (perch and dust-bath) allocation (HEA) and low enrichments (perch and dust-bath) allocation (LEA) were provided. Video observations of behavior were obtained from the focal hens between 14 and 18 weeks of age and perching, dust-bathing and other general behaviors of the hens with different social orders were measured. Results: Perching behavior of high SRO hens (HSR) were significantly higher than that of medium SRO hens (MSR), and that of the MSR were significantly higher than that of low SRO hens (LSR) (p<0.01), except for lying on perch (p>0.05). The hens in the high EA cage (HEAC) showed more lying behavior on perch than those in the low EA cage (LEAC) (p<0.01). The different SRO and EA did not affect dust-bathing behavior except vertical wing-shaking behavior (p<0.05). The LEA did not affect general behaviors (p>0.05), except standing and preening behaviors (p<0.01 and p<0.05), of which the hens in the HEAC showed less standing (p<0.01) and more preening behavior than the hens in the LEAC. Conclusion: The SRO of laying hens has a significant effect on the perching behaviors, but SRO and EA have little effect on dust-bathing and general behaviors.

Evaluation of $SrRuO_3$ Buffer Layer for $Pb(Zr,Ti)O_3$ Ferroelectric Capacitor ($Pb(Zr,Ti)O_3$ 강유전체 커패시터에 적용하기 위한 $SrRuO_3$ 버퍼 층의 특성 평가)

  • Kweon, Soon-Yong;Choi, Ji-Hye;Son, Young-Jin;Hong, Suk-Kyoung;Ryu, Sung-Lim
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.280-280
    • /
    • 2007
  • $Pb(Zr,Ti)O_3$ (PZT) 강유전체 박막은 높은 잔류 분극 (remanent polarization) 특성 때문에 현재 강유전체 메모리 (FeRAM) 소자에 적용하기 위하여 가장 활발히 연구되고 있다. 그런데 PZT 물질은 피로 (fatigue) 및 임프린트 (imprint) 등의 장시간 신뢰성 (long-term reliability) 특성이 취약한 단점을 가지고 있다. 이러한 신뢰성 문제를 해결할 수 있는 효과적인 방법 중의 하나는 $IrO_2$, $SrRuO_3$(SRO) 등의 산화물 전극을 사용하는 것이다. 많은 산화물 전극 중에서 SRO는 PZT와 비슷한 pseudo-perovskite 결정구조를 갖고 격자 상수도 비슷하여, PZT 커패시터의 강유전 특성 및 신뢰성을 향상시키는데 매우 효과적인 것으로 알려져 있다. 따라서 본 연구는 PZT 커패시터에 적용하기 위하여 SRO 박막을 증착하고 이의 전기적 특성 및 미세구조를 분석하고자 하였다. 또 실제로 SRO 박막을 상부전극과 PZT 사이의 버퍼 층 (buffer layer)으로 적용한 경우의 커패시터 특성도 평가하였다. 먼저 다결정 SRO 박막을 $SiO_2$/Si 기판 위에 DC 마그네트론 스퍼터링 법 (DC magnetron sputtering method)으로 증착하였다. 그 다음 이러한 SRO 박막의 미세구조, 결정성 및 전기적 특성이 증착 조건들의 변화에 따라서 어떤 경향성을 보이는지를 평가하였다. 기판 온도는 $350\;{\sim}\;650^{\circ}C$ 범위에서 변화시켰고, 증착 파워는 500 ~ 800 W 범위에서 변화시켰다. 또 Ar+$O_2$ 혼합 가스에서 산소의 혼합 비율을 20 ~ 50% 범위에서 변화시켰다. 이러한 실험 결과 SRO 박막의 전기적 특성 및 미세 구조는 기판의 증착 온도에 따라서 가장 민감하게 변함을 관찰할 수 있었다. 다른 증착 조건과 무관하게 $450^{\circ}C$ 이상의 온도에서 증착된 SRO 박막은 모두 주상정 구조 (columnar structure)를 형성하며 (110) 방향성을 강하게 나타내었다. 가장 낮은 전기 저항은 $550^{\circ}C$ 증착 온도에서 얻을 수 있었는데, 그 값은 약 $440\;{\mu}{\Omega}{\cdot}cm$ 이었다. SRO 버퍼 충을 적용하여 제작한 PZT 커패시터의 잔류 분극 (Pr) 값은 약 $30\;{\mu}C/cm^2$ 정도로 매우 높은 값을 나타내었고, 피로 손실 (fatigue loss)도 $1{\times}10^{11}$ 스위칭 사이클 후에 약 11% 정도로 매우 양호한 값을 나타내었다.

  • PDF

A Study on the Chest Radiography with Diseases in Consideration of Image Qualify and Patient Exposure (흉부질환의 화질과 피폭을 고려한 촬영조건의 연구)

  • Lee, Man-Koo;Hayashi, Taro;Ishida, Yuji
    • Journal of radiological science and technology
    • /
    • v.20 no.2
    • /
    • pp.56-62
    • /
    • 1997
  • To evaluated the image quality and the patient exposure for the chest radiography, its fundamental imaging properties were investigated. The basic imaging properties were evaluated by measuring characteristic curves, relative speeds, average gradient, and patient exposure dose. The image qualities were evaluated by using a rotating meter. It was found that the film gradient of SRO750/SRH system was 3.13 and that of SRO750/HR-C30 was 1.77. The ratio of SRO1000/TMH to FS/RP-1 was 1 to 18.2. It was possible to visualize the static image when the exposure time was less than 2.5 msec in patient that had respiratory excessive motion, heart beat and natural physical motion, and less than 8.5 msec in normal. The ratio of medical exposure dose compared with our method was 1 to 25 in the routine chest radiography and maximum was 1 to 70. In estimation of the image quality in same cases, we found that the image of SRO1000/SRH and TMH of super sensitive systems was the same results. We found that these super sensitive screen-film systems were available for the chest radiography considering the relationship between the image quality and patient exposure.

  • PDF

Replication Strategy using autonomous measurement of popularity on DHT based P2P System (DHT 기반 P2P 시스템에서 자율적인 인기도 측정을 이용한 복제 전략)

  • Han Dongyun;Cha Bonggwan;Son Youngsong;Kim Kyongsok
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2005.07a
    • /
    • pp.586-588
    • /
    • 2005
  • P2P (Peer-to-peer) 파일 공유 시스템에서 컨텐츠의 복제는 Hot Spot의 방지와 가용성의 보장, 검색 속도의 향상을 위해 사용되고 있다. 컨텐츠의 복제본의 수(공간 효율성)와 검색 성능은 일종의 trade-off로써 이 논문에서는 가능한 검색 성능을 향상시키면서 적절한 양의 복제본의 수를 유지하는 방법인 SRoD 알고리즘을 제안한다. SRoD는 DHT 기반 파일공유시스템에서 전반적으로 간단하게 접목하여 사용할 수 있다는 장점을 가지고 있다. 이러한 특징은 P2P가 추구하는 자율성과 평등성을 보장하기 위한 것이다. 본 논문에서는 SRoD 알고리즘을 설명하고 이것의 장점과 보완해야 할 점에 대해 논하게 될 것이다.

  • PDF

Image and Exposure Dose in Accordance with Radiation Quality on Plain Chest Radiography (흉부촬영(胸部撮影)에서 증감지(增感紙)-필름계의 선질변화(線質變化)에 따른 감도(感度)와 화질에 관(關)한 연구(硏究))

  • Kim, Jung-Min;Kim, Dong-Huan;Hayashi, Taro;Ishida, Yuji;Maeda, Mika;Sakura, Tatsuya
    • Journal of radiological science and technology
    • /
    • v.15 no.1
    • /
    • pp.65-78
    • /
    • 1992
  • Routine chest radiography is generally imaged by high voltage technique but some radiological technologists use low voltage for imaging. High voltage is usually said between $120\;kV{\sim}140\;kV$. Some RTs like using heavy filtration but others seldom like using it. However which is better for use calcium tungustate film screen system or ortho system and high contrast film or wide latitude c-type film for the exculusive use of chest radiography. We could not make a decision which is ideal method for use. In my opinion any method is not always exellent for chest radiography. In my experiments that I had at Kaken hospital in Japan last year I expect to keep the balance between image quality and diagnostic range and to reduce radiation dose for patients. My experiments are as follows. 1. We have looked into system characteristics(speed and contrast) in accordance with kVp($80{\sim}140$) and added filter($no{\sim}1/16\;VL$) in three screen film systems(BX3+CRONEX4, SRO750+MGH, SRO750+MGL). 2. We have looked into skin dose and film dose with same D=1.8 lung field density in accordance with kVp($80{\sim}140$) and added filter($no{\sim}1/16\;VL$) in three screen film systems. 3. We have compared with the evaluation between correlation of physical image quality(MTF) and optical diagnostic capability. Result are follows. 1. Speed of BX3+CRONEX4 became higher in accodance with kVp and thickness of filter but speed of ortho system was not as like regular system. Thicker filter diminished the speed over 100 kV range in SRO750+MGL. In case of SRO750+MGH speed of 1/16VL filter was looked into lower than speed of 1/4VL filter. Sensitivity of ortho system depends on tube voltage and added filter. 2. Skin dose has been detected $225\;{\mu}Gy{\sim}66\;{\mu}Gy$ in BX3+CRONEX4 from 80 kV, no filter to 140 kV, 1/16VL filter. SRO750+MGH could reduce the patient dose $1/2{\sim}1/3$ level in comparison to that of BX3+CRONEX4. 3. The higher kV was the worse MTF became the thicker filter was the worse MTF became too. MTF of BX3+CRONEX4 was detected better than MTF of SRO750+MGH but SRO750+MGH's optical detectability of small lesion in lung field came out better than that of BX3+CRONEX4. Conclusion Recently routine chest radiography is generally imaged by high voltage but it seems to be there are some questions in using of film screen combination. In high voltage chest radiography the subject contrast will come down that means latitude become wider. In this case if we select the low contrast film screen system(C or L type) the film contrast will fall down extremly and detectability of small lesion will be deteriorated. Wide latitude C, L type film has a merit of high detectability on mediastinum. Furthermore high contrast film screen system has the advantage to keep the high contrast in low density region as like mediastinum and heart shadow. Therefore in low subject contrast high voltage chest radiography we would rather choose the high contrast film screen system(H type) I think. From a view point of patient dose detectability of mediastinum and lung field. The optimum technical facter was found out 120 kV, 1/16VL filter : BX3+CRONEX4, 140 kV, 1/4VL filter : SRO750+MGH, 100 kV, 1/4VL filter : SRO750+MGL.

  • PDF

Double magnetic entropy change peaks and high refrigerant capacity in Gd1-xHoxNi compounds in the melt-spun form

  • Jiang, Jun-fan;Ying, Hao;Feng, Tang-fu;Sun, Ren-bing;Li, Xie;Wang, Fang
    • Current Applied Physics
    • /
    • v.18 no.12
    • /
    • pp.1605-1608
    • /
    • 2018
  • $Gd_{1-x}Ho_xNi$ melt-spun ribbons were fabricated by a single-roller melt spinning method. All the compounds crystallize in an orthorhombic CrB-type structure. The Curie temperature ($T_C$) was tuned between 46 and 99 K by varying the concentration of Gd and Ho. A spin reorientation (SRO) transition is observed around 13 K. Different from $T_C$, the SRO transition temperature is almost invariable for all compounds. Two peaks of magnetic entropy change (${\Delta}S_M$) were found. One at the higher temperature range was originated from the paramagnet-ferromagnet phase transition and the other at the lower temperature range was caused by the SRO transition. The maximum of ${\Delta}S_M$ around $T_C$ is almost same. The other maximum of ${\Delta}S_M$ around SRO transition, however, had significantly positive relationship with x. It reached a maximum about $8.2J\;kg^{-1}\;K^{-1}$ for x = 0.8. Thus double large ${\Delta}S_M$ peaks were obtained in $Gd_{1-x}Ho_xNi$ melt-spun ribbons with the high Ho concentration. And the refrigerant capacity power reached a maximum of $622J\;kg^{-1}$ for x = 0.6. $Gd_{1-x}Ho_xNi$ ribbons could be good candidate for magnetic refrigerant working in the low temperature especially near the liquid nitrogen temperature range.

Fluorine Penetration Characteristics on Various FSG Capping Layers (FSG Capping 레이어들에서의 플루오르 침투 특성)

  • Lee, Do-Won;Kim, Nam-Hoon;Kim, Sang-Yong;Eom, Joon-Chul;Chang, Eui-Goo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.04b
    • /
    • pp.26-29
    • /
    • 2004
  • High density plasma fluorinated silicate glass (HDP FSG) is used as a gap fill film for metal-to-metal space because of many advantages. However, FSG films can cause critical problems such as bonding issue of top metal at package, metal contamination, metal peel-off, and so on. It is known that these problems are caused by fluorine penetration out of FSG film. To prevent it, FSG capping layers such like SRO (Silicon Rich Oxide) are needed. In this study, their characteristics and a capability to block fluorine penetration for various FSG capping layers are investigated. Normal stress and High stress due to denser film. While heat treatment to PETEOS caused lower blocking against fluorine penetration, it had insignificant effect on SiN. Compared with other layers, SRO using ARC chamber and SiN were shown a better performance to block fluorine penetration.

  • PDF

Study on Fluorine Penetration of Capping Layers using FTIR analysis (FTIR을 이용한 캐핑레이어의 플루오르 침투 특성 연구)

  • Lee, Do-Won;Kim, Nam-Hoon;Kim, Sang-Yong;Kim, Tae-Hyoung;Chang, Eui-Goo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.300-303
    • /
    • 2004
  • To fill the gap of films for metal-to-metal space High density plasma fluorinated silicate glass (HDP FSG) is used due to various advantages. However, FSG films can have critical drawbacks such as bonding issue of top metal at package, metal contamination, metal peel-off, and so on. These problems are generally caused by fluorine penetration out of FSG film. Hence, FSG capping layers such like SRO(Silicon Rich Oxide) are required to prevent flourine penetration. In this study, their characteristics and a capability to block fluorine penetration for various FSG capping layers are investigated through FTIR analysis. FTIR graphs of both SRO using ARC chamber and SiN show that clear Si-H bonds at $2175{\sim}2300cm^{-1}$. Thus, Si-H bond at $2175{\sim}2300cm^{-1}$ of FSG capping layers lays a key role to block fluorine penetration as well as dangling bond.

  • PDF

Growth and characterization of superconductor-ferromagnet thin film heterostructure La1.85Sr0.15CuO4/SrRuO3

  • Kim, Youngdo;Sohn, Byungmin;Kim, Changyoung
    • Progress in Superconductivity and Cryogenics
    • /
    • v.23 no.2
    • /
    • pp.10-13
    • /
    • 2021
  • Superconductor-ferromagnet thin film heterostructure is an ideal system for studying the interplay between superconductivity and ferromagnetism. These two antagonistic properties combined in thin film heterostructure create interesting proximity effects such as spin-triplet superconductivity. Thin film heterostructure of optimally doped La2-xSrxCuO4(LSCO) cuprate superconductor and SrRuO3(SRO) ruthenate ferromagnet has been grown by pulsed laser deposition. Its temperature-dependent resistivity and Hall effect measurements show that our LSCO/SRO heterostructure has both superconductivity and ferromagnetism. In the Hall effect measurement results, we find additional hump-like structures appear in the anomalous Hall effect signal in the vicinity of superconducting transition. We conclude that giant magnetoresistance of the LSCO layer distorts the AHE signal, which results in a hump-like structure.

Ordering of Alloy 690 Steam Generator Tubings in a Nuclear Power Plant (원자력발전소 증기발생기 Alloy 690 전열관 재료의 규칙화 반응)

  • Seong Sik Hwang;Min Jae Choi;Sung Woo Kim
    • Corrosion Science and Technology
    • /
    • v.22 no.3
    • /
    • pp.214-219
    • /
    • 2023
  • Considering the case in the United States where most nuclear power plants with an initial design life of 40 years continue to operate until 60 or 80 years after undergoing material soundness evaluation, it is time to plan a more robust long-term operation strategy for nuclear power plants in Korea. There are some reports that SRO/LRO might be formed when Alloy 690 is heat treated for 10,000 hours to 100,000 hours at 360 to 450 ℃. The possibility of LRO formation in Alloy 690 steam generator tubings of Kori nuclear power plant unit 1 (Kori-1) was investigated using existing research papers. The mechanism in which SRO/LRO occurred was also surveyed. Alloy 690 was found to be more likely to cause ordering than Alloy 600 in terms of alloy composition. The ordering could be evaluated through changes in material properties. However, it is difficult to evaluate it from a microstructural point of view. The likelihood of LRO in Alloy 690 of the Kori-1 plant operated at 320 ℃ for 19 years seemed to be low in terms of time and exposure temperature.