• Title/Summary/Keyword: SR-B1

Search Result 345, Processing Time 0.022 seconds

Dielectric and Piezoelectric Properties of Pb-free Bi(Na, K)TiO3-SrTiO3 Ceramics with MnO2 Addition (MnO2 첨가에 따른 무연 Bi(Na, K)TiO3-SrTiO3 세라믹스의 유전 및 압전 특성)

  • Lee, Mi-Young;Ryu, Sung-Lim;Yoo, Ju-Hyun;Chung, Kwang-Hyun;Jeong, Yeong-Ho;Hong, Jae-Il;Yoon, Hyun-Sang
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.10
    • /
    • pp.1056-1060
    • /
    • 2004
  • In this study, 0.96B $i_{0.5}$($Na_{0.84}$ $K_{0.16}$)$_{0.5}$Ti $O_3$ + 0.04SrTi $O_3$ + 0.3 wt% N $b_2$ $O_{5}$+0.2 wt% L $a_2$ $O_3$ + xwt % Mn $O_2$ were investigated as a function of the amount of Mn $O_2$ addition in order to improve dielectric and piezoelectric properties of Lead-free piezoelectric ceramics. With increasing the amount of Mn $O_2$ addition, the density, electromechanical coupling factor( $k_{p}$), piezoelectric constant( $d_{33}$, $g_{33}$) and curie temperature (Tc) showed the maximum value of 5.7 g/㎤, 38 %, 219 pC/N, 26 mVㆍm/N and 32$0^{\circ}C$ at 0.1 wt% Mn $O_2$ addition, respectively, and mechanical quality factor( $Q_{m}$ ) showed the maximum value of 158 at 0.3 wt% Mn $O_2$ addition.ddition.ion.n.

Microstructure and Properties of $(Sr_{0.85}Ca_{0.15})TiO_3$ Thin Film with Annealing Temperature (열처리온도에 따른 $(Sr_{0.85}Ca_{0.15})TiO_3$박막의 구조 및 특성)

  • 김진사;조춘남;신철기;최운식;김충혁;이준웅
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.10
    • /
    • pp.802-807
    • /
    • 2001
  • The (S $r_{0.85}$C $a_{0.15}$)Ti $O_{3}$(SCT) thin films are deposited on Pt-coated electrode (Pt/TiN/ $SiO_2$/Si) using RF sputtering method. The composition of SCT thin films deposited on Si substrate at woom temperature is close to stoichiometry(1.102 in A/B ratio). The maximum dielectric constant of SCT thin films is obtained by annealing at 600[$^{\circ}C$]. The capacitance characteristics had a stable value within $\pm$4[%]. The drastic decrease of dielectric constant and increase of dielectric loss in SCT thin films is observed above 200[kHz]. SCT thin films used in this study show the phenomena of dielectric relaxation with the increase of frequencey.cey.

  • PDF

Testing Bacterial Spot Resistant Lines of Capsicum Pepper for Nuclear Genotype Interacting with Male Sterile Cytoplasm (고추 더뎅이병 저항성 계통의 세포질웅성불임 관련 핵내유전자형 검정)

  • 김병수;황희숙
    • Korean Journal Plant Pathology
    • /
    • v.14 no.3
    • /
    • pp.212-216
    • /
    • 1998
  • Capsicum pepper selections fro PI163192, PI241670, PI244670, PI271322, PI308787, PI322719, and PI369994 were confirmed to be non-hypersensitively resistant to race 3 of Xanthomonas campestris pv. vesicatoria. A resistant cultivar,‘SR’, was shown to be hypersensitive. Four Koran local cultivars, a cytoplasmic male sterile line (A-line) and its maintainer (B-line) were highly susceptible. The resistant selections and cultivars were crossed with a male sterile A-line (Smsms) and fertility of their F1 hybrids was examined by observing he pollen production, testing pollen germination, and quantifying the amount of pollen produced per anther to identify the genotype interacting with the male sterile cytoplasm. The seven resistant PI selections turned out to be restorers (N(S)MsMs) and‘SR’to be a maintainer (Nmsms).

  • PDF

On the Development of Parthenogenetic Oocytes by Cytochalasin B and Production of Cloned Mice by SCNT

  • Sim, Bo-Woong;Min, Kwan-Sik
    • Journal of Embryo Transfer
    • /
    • v.29 no.2
    • /
    • pp.111-117
    • /
    • 2014
  • This study was conducted to optimize the efficiency of cloning and to produce cloned mice. The majority of cloned mammals derived by nuclear transfer (NT) die during gestation and have enlarged and dysfunctional placentas. In this study, the optimized conditions were established to produce clone mice. The parthenogenetic oocytes were activated after 6 h regardless of cytochalasin B (CB) concentration. CB treatment ($2{\mu}g/ml$) was found second polar body. Lower concentration of CB was decreased the activation rate, but the second polar body was the best highly increased during 6 h incubation. The small fragments were exhibited in the $5{\mu}g/ml$ treatment of CB, but it was not found in lower concentration groups (> $2.5{\mu}g/ml$). To examine effects of $SrCl_2$ on the adult cumulus cells, somatic cell NT oocytes were exposed during 0.5, 1 and 6 hrs. The second polar body was significantly greater in 0.5 h exposure group (6.6%) than 1, 6 hrs. Developmental rate from 2-cell to 4-cell was the lowest in 7.5 mM Strontium chloride ($SrCl_2$) groups (84.1% and 64.3%) than 5, 10 m $MSrCl_2$. The implantation rate was not significantly difference among 5, 7.5 and 10 m $MSrCl_2$ group. Three live fetuses were produced by SCNT. SCNT placentas were remarkably heavier than IVF group (8 fetuses) (0.34, 0.34, 0.33 vs 0.14 g) compared with the placenta weight of IVF and SCNT clones.

Characteristics of HTS Tube Depending on Chemical Compositions

  • Jung, Seung-Ho;Jang, Guneik
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.1
    • /
    • pp.27-30
    • /
    • 2003
  • The Bi2212 based HTS tubes with 4 different compositions, Bi:Sr:Ca:Cu = 2.0:2.0:1.0:2.0, 2.1:2.0:1.0:2.0,2.2:1.8:1.0:2.0 and 2.2:1.8.1.0.2:2 with 10% of SrSO$_4$ were studied. For tube fabrication the optimum range of melt temperatures and preheating temperature and time for mold were 105$0^{\circ}C$~110$0^{\circ}C$ and 55$0^{\circ}C$ for 30min respectively. The mold rotating speed was 1000rpm. Typical tube dimension was 30/24mm in outside/inside diameter and 60mm in length. A tube was annealed at 84$0^{\circ}C$ for 40 hours in oxygen atmosphere. The plate like grains more than 20${\mu}{\textrm}{m}$ were well developed along the rotating direction of mold regardless of initial chemical compositions. The specimen with Bi2212 composition exhibited $T_c$ of 83K while the specimen with other compositions are lower than 60K. The measured $I_c and J_c$ at 77K(B = 0T) in Bi2212 composition were about 80A and 266A/$\textrm{cm}^2$.

How about IRMA Curve (IRMA 법 Curve에 관하여)

  • Chang, Hyunyeong;Sin, Sunyoung;Lee, Hyunju;Woo, Jearyong;Lee, Hoyoung
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.156-161
    • /
    • 2012
  • Purpose : IRMA method for the experimental reagents, as set out in the manual settings for doing and reporting the test results should, in principle. But many of the reagents allows for the setting of the plot does not have a lot of information. Depending on the angle setting of the table make a difference in test results and what settings are best suited to investigate. Materials and Methods : The hospital has Boramae DREAM10, Cobra, SR-300's using the Immunotech TSH reagents have been compared with the measurements. Since then there using EXCEL calculation of the equipment compared with the measurement. Results : In the comparison between each piece of equipment 1.SR-300: DREAM 10 y = 1.1376x - 0.046 (LOG-LOGIT), 2.SR-300: COBRA y = 1.0985x + 0.042 (LOG-LOG) 3.DREAM10: COBRA y = 0.965x + 0.0887 (LOG-LOG) was the result. In all charts the same X, Y axis, X values were good in general when you have. Linear-Logit value of Cobra Dream10 and Excel tends to match the calculated values provided. Conclusion : Is to guide the B / max, B / Total Logit Y axis of the chart is set to draw a look at the value equation when the X-axis LOG a high concentration are disadvantages rising urgently toward the slope. Linear-Logit plots close to the straight line has a curve. If you have a chart to guide on setting AS setting and therefore, set to guide the absence of information on the need to set up the experiment are thought to pass through.

  • PDF

SUPERSTRUCTURES OF Bi-Sr-Ca-Cu-O SUPERCONDUTORS (Bi-Sr-Ca-Cu-O계열 초전도체의 초구조)

  • Nam, Gung-Chan;Lee, Sang-Yun
    • Korean Journal of Materials Research
    • /
    • v.4 no.3
    • /
    • pp.268-279
    • /
    • 1994
  • The x-ray powtler pattern of single phase $Bi_2S_2CaCu_2O_{8+x}$ has been identified and fullyindexed using a pseudotetragonal subcell with a= 5.408, c = 30.83 $\AA$ and an incommensurate supercellwith reciprocal lattice vector, X$q^*$, given by $q^*=0.211b^*-c^*$. The x -ray powder pattern of the Pb-free110K superconductor phase "$Bi_2S_2CaCu_2O_{10+x}$" has many lines which belong t.o an incommensuratesupercell. Using elect.ron d~ffraction pImt.ographs as a indexing guide, an indexing scheme for the powderpattern has been obtained. The unit cell has a geometrically orthorhombic subcell a=5.411, b= 5.420, c=37.29(2) $\AA$. Supercell reflections have indices that are derived from the subcell k, 1 indices by addition uf$\pm q^*$, where $\pm q^*=0.211b^*-0.78c^*$The incommensurate con~ponent In the b dwection, $\delta$, is the same for both phases but on going from2212 to 2223 phase, the superlattic component in the c direction changes from commensurate($\varepsilon$=1) toincommensurate($\varepsilon$=0.78).X>$\varepsilon$=0.78).

  • PDF

Effects of Coupling Agents on the Rheological and Magnetic Properties of Plastic Ferrite Magnets (커플링제가 플라스틱 페라이트 자석의 레올로지와 자기특성에 미치는 영향)

  • 이석희;최준환;문탁진;정원용
    • Journal of the Korean Magnetics Society
    • /
    • v.8 no.5
    • /
    • pp.275-281
    • /
    • 1998
  • Effects of coupling agents on the rheological and magnetic properties of plastic ferrite magnets were investigated. Magnetic powder used was Sr-ferrite, and binder used was polypropylene (PP), and coupling agents used were ${\gamma}$-methacryloxypropyl trimethoxy silane (A174) and isopropyl triisostearoyl titanate (TTS). It was found that the addition of coupling agents to the PP/ferrite system reduced the melt viscosity and increased the magnetic properties considerably, and the treatment with TTS showed greater effect than A174 did. By comparison with that of the untreated one, the apparent viscosities of the mixtures treated with A174 and TTS decreased 23 % and 50%, respectively, at the shear rate of $1280\; sec^{-1}$ . Untreated plastic magnets showed remanent flux density $(B_r)$ of 1.89 kG and maximum energy energy product $(BH_{max})$ of 0.84 MGOe, and A174 treated magnets showed of Br 2.25 Kg and $BH_{max}$ of 1.23 MGOe. TTS treated magnets showed $B_r$ of 2.35 kG and $BH_{max}$ of 1.33 MGOe.

  • PDF

Sensitivity Analysis and Optimization of Design Variables Related to an Algorithm for Loss of Balance Detection (균형상살 검출 알고리즘에서 검출과 관련된 설계변수의 민감도 해석 몇 최적화)

  • Ko, B.K.;Kim, K.H.;Son, K.
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.1
    • /
    • pp.7-14
    • /
    • 2011
  • This study suggested an optimized algorithm for detecting the loss of balance(LOB) in the seated position. And the sensitivity analysis was performed in order to identify the role of each design variable in the algorithm. The LOB algorithm consisted of data processing of measured signals, an internal model of the central nervous system and a control error anomaly(CEA) detector. This study optimized design variables of a CEA detector to obtain improved values of the success rate(SR) of detecting the LOB and the margin time(MT) provided for preventing the falling. Nine healthy adult volunteers were involved in the experiments. All the subjects were asked to balance their body in a predescribed seated posture with the rear legs of a four-legged wooden chair. The ground reaction force from the right leg was measured from the force plate while the accelerations of the chair and the head were measured from a couple of piezoelectric accelerometers. The measured data were processed to predict the LOB using a detection algorithm. Variables S2, h2 and hd are related to the detector: S2 represents a data selecting window, h2 a time shift and hd an operating period of the LOB detection algorithm. S2 was varied from 0.1 to 10 sec with an increment of 0.1 sec, and both h2 and hd were varied from 0.01 to 1.0 sec with an increment of 0.01 sec. It was found that the SR and MT were increased by up to 9.7% and 0.497 sec comparing with the previously published case when the values of S2, h2 and hd were set to 4.5, 0.3 and 0.2 sec, respectively. Also the results of sensitivity analysis showed that S2 and h2 had considerable influence on the SR while these variables were not so sensitive to the MT.

Effects of Scutellariae Radix on Neuronal Apoptosis of Spinal Cord Contusion Injury in Rats (황금(黃芩)이 척수압박손상 흰쥐의 척수신경세포 자연사에 미치는 영향)

  • Bahn, Hyo-Jung;Jo, Jong-Jin;Kim, Bum-Hoi;Park, Seong-Ha;Shin, Jung-Won;Kim, Seong-Joon;Sohn, Nak-Won
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.21 no.4
    • /
    • pp.13-22
    • /
    • 2011
  • Objectives : This Study was performed to evaluate the effects of Scutellariae Radix(SR) water-extract on the tissue and neuronal apoptosis of the spinal cord injury(SCI). Methods: SCI was induced by mechanical contusion following laminectomy of 10th thoracic vertebra in Sprague-Dawley rats. SR was orally given once a day for 7 days after SCI. Neuronal apoptosis was examined with terminal deoxynucleotidyl transferase-mediated dUTPnick-end labeling(TUNEL) assay. Bax (Bcl-2-asociated X protein), Bcl-2(B-cell blastoma 2), c-Fos(FBJ osteosarcoma oncogene) expressions were examined using immuno-histochemistry. Individual TUNEL and immuno-labeled cells expressing Bax, Bcl-2 and c-Fos were counted on the same level in peri-damaged region and in ventral horn. Results: 1. SR significantly reduced number of TUNEL labeled apoptotic cells induced by the spinal cord contusion injury. 2. SR significantly reduced Bax positive cells expression on the motor neuron in the ventral horn induced by the spinal cord contusion injury. 3. SR strengthened Bcl-2 expression on the motor neuron in the ventral horn induced by the spinal cord contusion injury. 4. SR reduced c-Fos expression on the motor neuron in the ventral horn induced by the spinal cord contusion injury. Conclusions : These results suggest that SR plays an inhibitory role against neuronal apoptosis and has significant effects for locomotor disfunction induced by SCI.