• 제목/요약/키워드: SQUID sensor data

검색결과 6건 처리시간 0.019초

소형 SQUID, 직접 되먹임 방식 전자회로, 고온초전도 SQUID 주사현미경의 개량 (Development of Small-sized SQUID and Direct-coupled Electronics for High-$T_c$ Scanning SQUID Microscope)

  • 백범;이승민;윤주환;김정구
    • Progress in Superconductivity
    • /
    • 제3권1호
    • /
    • pp.78-82
    • /
    • 2001
  • The spatial resolution of $high-T_{c}$ scanning SQUID microscope is limited by the washer size of SQUID and the gap distance between SQUID sensor and the sample. In this work, we tried to improve the spatial resolution of scanning SQUID microscope by reducing the size of SQUID sensor fabricated with $YBa_2$$Cu_3$$O_{7}$ thin film. Outer dimensions of the SQUiDs we tested are 24 $\mu\textrm{m}$ $\times$ $ 28\mu\textrm{m}$, $12 \mu\textrm{m}$ $\times$ $16\mu\textrm{m}$, $12\mu\textrm{m}$ x $12\mu\textrm{m}$, $10 \mu\textrm{m}$ $\times$ $10 \mu\textrm{m}$ each. To operate them in the flux-locked loop scheme, we used a direct-coupled electronics instead of using conventional electronics involving a modulation scheme. Since the direct-coupled feedback scheme does not require modulation current adjustment that poses as a practical difficulty in the SQUID operation in modulation-scheme, the direct feedback operation is rather simpler than the conventional modulation method. The resulting noise features were dominated by the noise of preamp in FLL electronics except that of the largest SQUID. The noise levels of SQUIDs are expected below 1$\times$$10^{-5}$ $\Phi_{0}$H $z^{1}$2/ (at 300 Hz), that is a typical noise level for SQUID made of $YBa_2$C $u_3$$O_{7}$ thin film. The data acquisition and motion-controlling parts were also improved, resulting in faster data acquisition rate and less vibration of the system.m.

  • PDF

256-channel 1 ksamples/sec 심자도 신호획득 시스템 (256-channel 1ks/s MCG Signal Acquisition System)

  • 이동하;유재택;허영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.538-540
    • /
    • 2004
  • Electrical currents generated by human heart activities create magnetic fields represented by MCG(MagnetoCardioGram). Since an MCG signal acquisition system requires precise and stable operation, the system adopts hundreds of SQUID(Superconducting QUantum Interface Device) sensors for signal acquisition. Such a system requires fast real-time data acquisition in a required sampling interval, i.e., 1 mili-second for each sensor. This paper presents designed hardware to acquire data from 256-channel analog signal with 1 ksamples/sec speed, using 12-bit 8-channel ADC devices, SPI interfaces, parallel interfaces, 8-bit microprocessors, and a DSP processor. We implemented SPI interface between ADCs and a microprocessor, parallel interfaces between microprocessors. Our result concludes that the data collection can be done in $168{\mu}sec$ time-interval for 256 SQUID sensors, which can be interpreted to 6 ksamples/sec speed.

  • PDF

다채널 스퀴드 미분계에서 센서 잡음이 위치추정 오차에 미치는 영향 (Influence of Sensor Noise on the Localization Error in Multichannel SQUID Gradiometer System)

  • 김기웅;이용호;권혁찬;김진목;정용석;강찬석;김인선;박용기;이순걸
    • Progress in Superconductivity
    • /
    • 제5권2호
    • /
    • pp.98-104
    • /
    • 2004
  • We analyzed a noise-sensitivity profile of a specific SQUID sensor system for the localization of brain activity. The location of a neuromagnetic current source is estimated from the recording of spatially distributed SQUID sensors. According to the specific arrangement of the sensors, each site in the source space has different sensitivity, that is, the difference in the lead field vectors. Conversely, channel noises on each sensor will give a different amount of the estimation error to each of the source sites. e.g., a distant source site from the sensor system has a small lead-field vector in magnitude and low sensitivity. However, when we solve the inverse problem from the recorded sensor data, we use the inverse of the lead-field vector that is rather large, which results in an overestimated noise power on the site. Especially, the spatial sensitivity profile of a gradiometer system measuring tangential fields is much more complex than a radial magnetometer system. This is one of the causes to make the solutions of inverse problems unstable on intervening of the sensor noise. In this study, in order to improve the localization accuracy, we calculated the noise-sensitivity profile of our 40-channel planar SQUID gradiometer system, and applied it as a normalization weight factor to the source localization using synthetic aperture magnetometry.

  • PDF

심자도 신호 획득을 위한 고속 병렬 데이터 전송 구현 (Implementation of high-speed parallel data transfer for MCG signal acquisition)

  • 이동하;유재택
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 추계학술대회 논문집 Vol.17
    • /
    • pp.444-447
    • /
    • 2004
  • A heart diagnosis system adopts hundreds of Superconducting Quantum Interface Device(SQUID) sensors for precision MCG(Magnetocardiogram) or MEG(Magnetoencephalogram) signal acquisitions. This system requires correct and real-time data acquisition from the sensors in a required sampling interval, i.e., 1 mili-second. This paper presents our hardware design and test results, to acquire data from 256 channel analog signal with 1-ksample/sec speed, using 12-bit 8-channel ADC devices, SPI interfaces, parallel interfaces, and 8-bit microprocessors. We chose to implement parallel data transfer between microprocessors as an effective way of achieving such data collection. Our result concludes that the data collection can be done in 250 ${\mu}sec$ time-interval.

  • PDF

전자센서와 다변량 분석을 이용한 국내 국·탕류의 향미 특성 분석 (Electronic Sensors and Multivariate Approaches for Taste and Odor in Korean Soups and Stews)

  • 부창국;홍성준;조진주;신의철
    • 한국식품위생안전성학회지
    • /
    • 제35권5호
    • /
    • pp.430-437
    • /
    • 2020
  • 본 연구는 전자코와 전자혀 시스템을 이용한 15가지 국내 식품에 대한 맛과 향에 대한 기본 접근 연구를 진행하였다. 먼저 전자혀 시스템을 이용한 샘플의 맛 성분에 대해 상대적인 센서 강도를 제시하였다. 신맛으로 대표되는 SRS 센서에서는 소고기배추국이 가장 높은 9.0을 나타내었고, 미역국에서 가장 낮은 3.7을 나타내었다. 짠맛으로 대표되는 STS 센서는 오징어국에서 가장 높은 8.2를 나타내었고, 소고기배추국이 가장 낮은 1.9를 나타내었다. 감칠맛으로 확인되는 UMS 센서의 경우 소고기배추국이 가장 높은 10.1을 보였고, 달걀국이 가장 낮은 3.3을 나타내었다. 단맛에 관여하는 SWS 센서에서는 비교적 큰차이를 보이지 않았는데, 시금치된장국이 가장 높은 7.3을 나타내었고, 달걀국이 가장 낮은 4.6을 나타내었다. 마지막으로 쓴맛에 기여하는 BRS 센서에서는 시래기 된장국이 가장 높은 7.8을 나타내었으며, 햄김치찌개에서 가장 낮은 4.4를 보였다. 주성분 분석을 통해 5가지 맛 성분과 15가지 샘플에 대한 패턴을 확인한 결과 PC1에서 56.21%의 variance를 확인하였고, PC2에서 25.23%의 variance를 확인할 수 있었다. 각 맛 성분의 경우 SRS 센서의 경우 PC1과 PC2의 factor loading의 경우 -0.95와 -0.20을 나타내었고, STS 센서의 경우 PC1과 PC2의 factor loading의 값이 0.96과 0.14, UMS 센서의 경우 PC1과 PC2의 factor loading의 값이 -0.94와 0.22, SWS 센서의 경우 PC1과 PC2의 factor loading의 값이 0.08과, 0.89, 그리고 BRS 센서의 경우 PC1과 PC2의 factor loading의 값이 0.32와 -0.60을 각각 나타내었다. 군집분석을 통해 확인된 샘플간의 유사도는 크게 4개의 cluster를 확인할 수 있었다. 15가지 샘플에서 확인된 향기성분은 총 25가지 성분이 확인되었고, 모든 샘플에서 상대적으로 가장 높은 함량을 보이는 향기성분은 ethanol과 2-methylthiophene으로 확인되었다. 주성분 분석을 통해 휘발성 향기 성분과 15가지 샘플에 대한 패턴을 확인한 결과 PC1에서 28.54%의 variance를 확인하였고, PC2에서 20.80%의 variance를 확인할 수 있었다. 군집분석의 경우 크게 3개의 cluster로 분류되는 것을 확인할 수 있었다. 이러한 맛과 향에 대한 연구를 통해서 국내 식품에 대한 표준 자료로써의 활용이 가능할 것으로 판단된다.

한국형 뇌자도 시스템을 이용한 유발 자계 측정 및 임상 응용 (Measurement of Neuromagentic Evoked Fields Using Korean Magnetoencephalography system and Its Clinical Application)

  • 김봉수;장원석;황수정;김기웅;권혁찬;유권규;김진목;이용호;장진우
    • 전자공학회논문지
    • /
    • 제51권10호
    • /
    • pp.213-220
    • /
    • 2014
  • 시공간 분해능이 우수하고 비침습적으로 대뇌 신경활동의 측정이 가능한 뇌자도는 뇌기능 연구 및 뇌질환 진단에 유용한 진단용 의료기기이다. 순수 국내기술로 개발한 한국형 뇌자도 시스템을 임상시설(병원)에 설치하고 뇌질환 환자를 대상으로 유발자계를 측정, 분석하여 한국형 뇌자도 시스템의 임상 응용 가능성을 검토하였다. 1) 반측성 안면 경련 환자를 대상으로 소리자극에 대한 청각유발자계를 측정, 분석하여 안면신경과 청신경의 상호작용 여부 및 이명과의 연관성 검토, 2)뇌종양 환자의 정중신경 자극에 대한 체성감각 유발자계를 측정하여 뇌전증 유무에 따른 연관성 검토. 뇌자도 데이터의 분석 결과로부터 한국형 뇌자도 시스템이 뇌기능 연구 및 뇌질환 진단에 유용한 시공간적인 분석 정보를 제공할 수 있음을 시사하고 있다.