• Title/Summary/Keyword: SND

Search Result 73, Processing Time 0.023 seconds

A real-time vision system for SMT automation

  • Hwang, Shin-Hwan;Kim, Dong-Sik;Yun, Il-Dong;Choi, Jin-Woo;Lee, Sang-Uk;Choi, Jong-Soo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10b
    • /
    • pp.923-928
    • /
    • 1990
  • This paper describes the design and implementation of a real-time, high-precision vision system and its application to SMT(surface mounting technology) automation. The vision system employs a 32 bit MC68030 as a main processor, and consists of image acquisition unit. DSP56001 DSP based vision processor, and several algorithmically dedicated hardware modules. The image acquisition unit provides 512*480*8 bit image for high-precision vision tasks. The DSP vision processor and hardware modules, such as histogram extractor and feature extractor, are designed for a real-time excution of vision algorithms. Especially, the implementation of multi-processing architecture based on DSP vision processors allows us to employ more sophisticated and flexible vision algorithms for real-time operation. The developed vision system is combined with an Adept Robot system to form a complete SMD system. It has been found that the vision guided SMD assembly system is able to provide a satisfactory performance for SND automation.

  • PDF

Digital correction and calibration circuits for a high-resolution CMOS pipelined A/D converter (파이프라인 구조를 가진 고해상도 CMOS A/D 변환기를 위한 디지탈 교정 및 보정 회로)

  • 조준호;최희철;이승훈
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.6
    • /
    • pp.230-238
    • /
    • 1996
  • In this paper, digital corrction and calibration circuit for a high-resolution CMOS pipelined A/D converter are proposed. The circuits were actually applied to a 12 -bit 4-stage pipelined A/D converter which was implemented in a 0.8${\mu}$m p-well CMOS process. The proposed digital correction logic is based on optimum multiplexer and two nonoverlapping clock phases resulting in a small die area snd a modular pipelined architecture. The propsoed digital calibration logic which consists of calibration control logic, error averaging logic, and memory can effectively perform self-calibration with little modifying analog functional bolcks of a conventional pipelined A/D conveter.

  • PDF

Stduy on the Surface Grinding Machining of Fine-ceramics with high efficiency (화인세라믹스의 고능률적 평면 연삭가공을 위한 실험적 연구(I))

  • Gang, Jae-Hoon;Lee, Jae-Kyung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.7 no.4
    • /
    • pp.40-54
    • /
    • 1990
  • Recently, Fine Ceramics have been concerned significantly with some excellent properties and many functions as new industrial materials to the industry at alrge. For the manufacture of Fine Ceramics, sintering is essential process. Thus the most of a Fine Ceramics used for precision parts are in need of machining proces. It is, however, very difficult to manufacture the Advanced Ceramics with high efficiency because they have not only high strength and brittl- eness but also high hardness. In present research, experiments are carried out to obtain the basic knowledge of Fine Ceramics grinding with high efficiency. Representative advanced ceramics, such as A1/sub 2/0/sub 3/, Z/sub r/O/sub 2/SiC snd Si/sub 2/N/sub 4/are ground with diamond wheels using conventional surface grinding machine. This research is carried out for the purpose of saving machining technology required for manufactiring Fine Ceramics parts

  • PDF

Comparative Anatomic Structures of Nonhuman Primate Lungs 2. Tracheobronchial Geometry and Lung Lobe Weight (영장동물폐(靈長動物肺)의 비교해부학적연구(比較解剖學的硏究) 2. 기관(氣管) 및 기관지(氣管枝)의 기하학적계측(幾何學的計測)과 폐중량(肺重量)에 관(關)한 연구(硏究))

  • Kim, Moo Gang;Kim, James C.S.
    • Korean Journal of Veterinary Research
    • /
    • v.19 no.1
    • /
    • pp.9-15
    • /
    • 1979
  • Anatomical measurements were made at the necoropsy and sacrifice in a group of 41 adult female Rhesus monkey to determine the 34 characteristcs found in tracheas snd bronchus. Table 1, 2, 3, 4, and figure 1 were therefore prepared as a guide in the further use for illustrating monkey lung research. Summary of this report is as follows: 1. Accurate Knowledge of these measurements may have some value in pulmonary dissection and reconstructive procedures. 2. These studies may provide a more accurate determination of the monkey lungs. 3. The right and left bronchus length of the monkey is shorter than fornd in man. 4. The left bronchus length is more longer than the rrght bronchas. 5. There were large variation among the weight of adult female Rhesus monkey.

  • PDF

Surface and Interface Analysis with Medium Energy Ion Scattering Spectroscoppy

  • Moon, Dae-Wom
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1998.02a
    • /
    • pp.129-129
    • /
    • 1998
  • Most of the surface/interface analysis tools have limited depth profiling c capability in terms of the profiling range and the depth resolution. However, M MEIS can profile the surface and subsurface composition and structure q quantitatively and non-destructively with atomic layer depth resolution. I In this presentation, the MEIS system developed at KRISS will be briefly d described with an introduction on the principle of MEIS. Recent MEIS r results on the surface and interface composition and structural change due to i ion bombardment will be presented for preferential sputtering of T:없Os and d damage depth profiles of SHooD, Pt(l11), and Cu(l1D due to Ar+ ion b bombardment. Direct observation of strained Si lattices and its distribution i in the SHool)-SiCh interface and the initial stage of Co growth on Pt(l11) w will be reported. H surfactant effects on epitaxial growth of Ge on Si(ooD w will be discussed with STM results from SND.

  • PDF

The Characteristics of SMD Inductor Core (SMD Inductor Core의 전기적 특성)

  • Oh, Yong-Chul;Kim, Jin-Sa;Lee, Dong-Gyu;Shin, Chul-Ki;Kim, Ki-Joon;Lee, Chul-Hwan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.05b
    • /
    • pp.85-88
    • /
    • 2005
  • In this study, it analysis electric field of SMD(Surface Mounted Device) Inductor Core and it get electric field only exist inside of SMD core. Therefore electric fields do not affect any device and equipments. These results are very important to design data acquisition system(several test equipments such as temperature, impedance, and current test), because data acquisition system can place under the SND Inductor core. So, it can be decrease their test error due to electric field.

  • PDF

A Study on the Downward Filteration Movement, the Dust Collection and Filteration Plane Constitution by the use of Infinity (무한대를 이용하는 여과평면 구성 및 하향 여과공기 거동조성과 최적집진에 관한 연구)

  • 정동백
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.11 no.4
    • /
    • pp.373-375
    • /
    • 1995
  • In order to turn the Bag Filter to the Purse Filter, the past system that the adverse reason is removed, the input of synthetic materiality of dust and air is placed down, and the output is placed up has been improved so that any adverse effect shall not be raised. The form of filteration mechanism is changed from a cylinder from, and the dust and air is mixed to make the entry velocity and one person can velocity of the mixed materiality become lower by the use of infinity, and the reception of filteration mechanism has been made reasonably. The dust separated from the filteration mechanism is desceded down, snd the mixde materiality is ascended up. So, a cross point is formed, and a collision and a friction is occurred from its process, and at its result, dust is scattered to stick to a filter cloth, therefore, the loss of pressure shall ont be appeared by cause of the increase of dust-loading.

  • PDF

Effects of Rhus Verniciflua Strokes Extracts snd its Components on the Proliferation, Collagen Synthesis, and the Mrna Level of Hepatic Fibrosis Related Proteins in Rat Hepatic Stellate Cells

  • Jung, Seung-Hyun;Kim, Jeong-Ran;Na, Chun-Soo;Park, Bum-Rak;Yoon, Sun-Young;Park, Young-In;Dong, Mi-Sook
    • Proceedings of the Korean Society of Toxicology Conference
    • /
    • 2003.10b
    • /
    • pp.167-167
    • /
    • 2003
  • Hepatic stellate cells (HSC) and the derived myofibroblasts are known to playa central role in liver fibrosis. Rhus verniciflua Strokes (RVS) has traditionally been used in Korea herbal medicine for a stomachic tonic. In this study, we observed the effect of RVS acetone extract (Ra) on the proliferation, the collagen synthesis, and hepatic fibrosis related proteins mRNA levels in HSC-T6 cells which is a fully acivated rat hepatic stellate cell line.(omitted)

  • PDF

The Safety and Usefulness of Combined Video-Assisted Mediastinoscopic Lymph Adenectomy and Video-Assisted Thoracic Surgery Lobectomy for Left-sided Lung Cancer (좌측 폐암 환자에서 동반 시행한 비디오 종격동경 림프절 절제술과 흉강경 폐엽 절제술의 안정성과 유용성)

  • Jung, Hee Suk;Kim, Yong Hee;Park, Seung-Il;Kim, Dong-Kwan
    • Journal of Chest Surgery
    • /
    • v.43 no.1
    • /
    • pp.33-38
    • /
    • 2010
  • Background: The use of video-assisted thoracic surgery (VATS) to perform major pulmonary resection with systematic node dissection (SND) for lung cancer by is commonly used in clinics. However, the feasibility of SND by VATS remains controversial. Video-assisted mediastinal lymphadenectomy (VAMLA) increases the quality of mediastinal lymph node staging in lung cancer. The video-mediastinoscope allows systematic lymphadenectomy by bimanual preparation. This study was conducted to assess safety and usefulness and clinical feasibility of VAMLA expanding Linder-Dahan mediastinoscope with VATS lobectomy for left sided lung cancer. Material and Method: Between February 2004 to April 2008, a total 50 patients who underwent VATS lobectomy for left sided lung cancer were analyzed retrospectively. Thirty patients (group A) underwent VAMLA followed by VATS lymphadenectomy and 20 patients (group B) underwent VATS lymphadenectomy for SND. Result: There were no statistical differences in operation times, chest tube indwelling times, or hospital days between the 2 groups. The number of dissected total nodes (p=0.001) and N2 nodes (p=0.013) were higher in group A than in group B, but there was no difference in N1 nodes. Postoperative complications included 2 prolonged air leakages (${\geq}$10 days) in each group, one pneumonia in group A, and one vocal cord palsy in group B. There were no early operative mortalities. Conclusion: Mediastinal staging of resectable lung cancer is performed by VAMLA. This new technique is the basis for VATS lobectomy particularly for left-sided lung cancer, because a higher percentage of mediastinal lymph nodes undergo complete resection using VAMLA.

Change in Influent Concentration of Domestic Wastewater from Separated Sewer and Biological Nitrogen and Phosphorus Removal of a Full Scale Air-vent SBR (분류식 하수관거로의 전환시 유입하수의 성상 변화 및 선회와류식 SBR공법의 처리 특성)

  • Lee, Jang-Hee;Kang, Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.1
    • /
    • pp.63-70
    • /
    • 2012
  • This study was carried out to investigate change in influent concentration of domestic wastewater flowed from a newly constructed separate sewer system (SSS) and biological nutrients removal efficiency of a full scale Air-vent sequential batch reactor (SBR, $600m^3/d$). The average concentration of $BOD_5$, SS, T-N and T-P from SSS were 246.5 mg/L, 231.6 mg/L, 42.974 mg/L, 5.360 mg/L, respectively which corresponds to 2.2times, 1.2times, 1.8times and 2.1times higher than those from the conventional combined sewer system (CSS). The removal efficiency of $BOD_5$, SS, T-N, and T-P for the Air-vent SBR operated with influent from SSS averaged 99.1%, 99.0%, 91.2%, and 93.5%, respectively. Especially the respective nitrogen and phosphorus removal was 15% greater than that of the SBR operated with influent from CSS. Simultaneous nitrification and denitrification (SND) was observed in an aerobic reactor(II) as a result of DO concentration gradient developed along the depth by the Air-vent system. In order to achieve T-N removal greater than 90%, the C/N ratio should be over 6.0 and the difference between $BOD_5$ loading and nitrogen loading rate be over 100 kg/day (0.130 kg $T-N/m^3{\cdot}d$). Even with high influent T-P concentration of 5.360 mg/L from SSS (compared with 2.465 mg/L from CSS) T-P removal achieved 93.5% which was 15.5% higher than that of the SBR with influent from CSS. This is probably due to high influent $BOD_5$ concentration from SSS that could provide soluble carbon source to release phosphorus at anaerobic condition. In order to achieve T-P removal greater than 90%, the difference between $BOD_5$ loading and phosphorus loading rate should be over 100 kg /day (0.130 kg $T-N/m^3{\cdot}d$).