• 제목/요약/키워드: SFC program

검색결과 20건 처리시간 0.026초

Safety assessment of nuclear fuel reprocessing plant under the free drop impact of spent fuel cask and fuel assembly part I: Large-scale model test and finite element model validation

  • Li, Z.C.;Yang, Y.H.;Dong, Z.F.;Huang, T.;Wu, H.
    • Nuclear Engineering and Technology
    • /
    • 제53권8호
    • /
    • pp.2682-2695
    • /
    • 2021
  • This paper aims to evaluate the structural dynamic responses and damage/failure of the nuclear fuel reprocessing plant under the free drop impact of spent fuel cask (SFC) and fuel assembly (FA) during the on-site transportation. At the present Part I of this paper, the large-scale SFC model free drop test and the corresponding numerical simulations are performed. Firstly, a composite target which is composed of the protective structure, i.e., a thin RC plate (representing the inverted U-shaped slab in the loading shaft) and/or an autoclaved aerated concrete (AAC) blocks sacrificial layer, as well as a thick RC plate (representing the bottom slab in the loading shaft) is designed and fabricated. Then, based on the large dropping tower, the free drop test of large-scale SFC model with the mass of 3 t is carried out from the height of 7 m-11 m. It indicates that the bottom slab in the loading shaft could not resist the free drop impact of SFC. The composite protective structure can effectively reduce the damage and vibrations of the bottom slab, and the inverted U-shaped slab could relieve the damage of the AAC blocks layer dramatically. Furthermore, based on the finite element (FE) program LS-DYNA, the corresponding refined numerical simulations are performed. By comparing the experimental and numerical damage and vibration accelerations of the composite structures, the present adopted numerical algorithms, constitutive models and parameters are validated, which will be applied in the further assessment of drop impact effects of full-scale SFC and FA on prototype nuclear fuel reprocessing plant in the next Part II of this paper.

제어 시스템 설계를 위한 IEC 1131-3 기반의 제어 로직 생성기의 개발 (Development of a IEC 1131-3-Based Control Logic Generator for the Control System Design)

  • 정구;심주현;이제필;이철수
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2001년도 춘계학술대회 논문집(한국공작기계학회)
    • /
    • pp.171-176
    • /
    • 2001
  • This paper describes the methodology of an IEC 1131-3-based control logic generator for the control system design and converting algorithm between programmable languages. The proposed control logic generator is generated based on the software model and common element with data type, variables, POUs(program organization unit) and execution control unit commonly used within programmable languages of IEC 1131-3 Standard. The generation method of object file was proposed on five programmable language based on IECI 131-3. The generation method of object file is represented as following; 1) the generation method using conversion algorithm from LD to IL with FBD(function block diagram), 2) the generation method using C code generation algorithm from SFC using the SFC execution sequence with FBD and ST(structured text). The proposed control logic generator was implemented by Visual C++ and MFC on MS-windows NT 4.0

  • PDF

PLC에 의한 블록별 제어 (Control of Block Unit By PLC)

  • 유정봉
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.249-251
    • /
    • 2008
  • In Factory Automation(FA) used by Programmable Logic Controller(PLC), Ladder Diagram(LD) is the most widely utilized and plays an important role in industrial control system. But recently, the study about Sequential Function Chart(SFC) is performed actively. When we program by SFC, generally, we design one routine from start to end. This method is difficult to design block control system, and we often make mistakes. In this paper, we propose the method that we design block control system and we analysis the difference of the method used this paper from conventional method.

  • PDF

산업공정제어 시스템을 위한 계층제어구조의 효율적인 서브시스템의 결합에 관한 연구 (Study about a union of efficient subsystem of hierarchical control structure for industrial process control system)

  • 남상엽;유정봉
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2006년도 하계종합학술대회
    • /
    • pp.1021-1022
    • /
    • 2006
  • In industrial control system used by Programmable Logic Controller(PLC), Ladder Diagram(LD) is the most widely utilized and plays an important role in industrial control system. But recently, the study about Sequential Function Chart(SFC) is performed actively. When we program by SFC, generally, we design one routine from start to end. This method is difficult to design, and we often make mistakes. In this paper, we propose the method that we compose each sub-system after we design each sub-system, and we analysis the difference of the method used this paper from conventional method.

  • PDF

계층제어구조에서 결합된 서브시스템의 비교분석 (Comparison Analysis of Subsystem composited in Hierarchical Control Structure)

  • 유정봉
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.462-466
    • /
    • 2006
  • In industrial control system used by Programmable Logic Controller(PLC), Ladder Diagram(LD) is the about widely utilized and plays an important role in industrial control system. But recently, the study about Sequential Function Chart(SFC) is performed actively. When we program by SFC, generally, we design one routine from start to end. This method is difficult to design, and we often make mistakes. In this paper, we propose the method that we compose each sub-system after we design each sub-system and we analysis the difference of the method used this paper from conventional method.

  • PDF

PLC용 RISC 프로세서의 구조와 명령어에 관한 연구 (A study on the architecture and instruction of a RISC processor for programmable logic controller)

  • 구경훈;박재현;장래혁;권욱현
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1993년도 한국자동제어학술회의논문집(국내학술편); Seoul National University, Seoul; 20-22 Oct. 1993
    • /
    • pp.1012-1017
    • /
    • 1993
  • In this paper, the instruction set and the architecture of a RISC processor for programmable logic controller is suggested. From the measurement of existing programs, the characteristics of ladder instructions are analyzed. The instruction set is defined so that the existing ladder program can be reused with simple translation. Because bit instructions controls the behavior of word instructions, the processor suits for high level language like SFC. Simulations show that the PLC with the suggested processor is twenty times faster than the PLC with the multi-purpose microprocessor.

  • PDF

선택시퀀스 기능을 위한 단일시퀀스의 시간지연에 관한 연구 (Study on the Time Delay of Single Sequence for Select Sequence)

  • 유정봉
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2009년도 정보 및 제어 심포지움 논문집
    • /
    • pp.305-307
    • /
    • 2009
  • When we design the control system used Programmable Logic Controller(PLC), we program the main algorithm by Ladder Diagram(LD) among the standard language. We can substitute the select sequence function by the unique sequence. We can implement this function by the delay time. Therefore this thesis show the select sequence function by the unique sequence and we confirmed its feasibility through actual example.

  • PDF

분석 및 분리용 크로마토그래피에서 조업조건의 최적화를 위한 HCI 프로그램의 이용 (Use of HCI Program for Optimization of Operating Conditions in Analytical and Preparative Chromatography)

  • 이주원;이민우;노경호
    • KSBB Journal
    • /
    • 제14권4호
    • /
    • pp.408-413
    • /
    • 1999
  • 빠른 분석시간과 우수한 분리도를 가진 분석기기로서 크로마토그래피가 분취용으로 이용되기 위해서는 많은 시료양을 취급할 수 있어야 한다. 이 경우 충전물과 관의 크기가 커지게 되면 관의 효율은 분석용에 비해서 떨어지게 된다. 순도와 수율에 미치는 변수가 서로 복잡하게 연관되어 있기때문에 특히 분취용 조업조건의 최적화는 많은 경험과 실험이 요구된다. 또한 많은 상관된 실험변수들이 있고 분리하고자 하는 물질의 종류가 다양하기 때문에 수학적 모델을 적용하여 시료가 관내에서 거동 (behavior)을 예측하는 것이 쉽지 않다. 이러한 문제점을 해결하기 위해서 외국에서는 최소한의 실험을 통하여 고분가 가치 물질을 효율적이고 경제적으로 얻기 위한 크로마토그래피용 프로그램을 활발하게 이용하기 시작하였다. 인하대학교 고순도분리연구실에서 개발된 HCI 프로그램은 단지 LC에 국한된 것이 아니라 GC,SFC (supercritical fluid chromatography) 뿐만아니라 연속식 시스템인 SMB (simulated moving bed)까지 확장될 예정이다.

  • PDF

이진 페트리 네트의 메모리-베이스 구현을 기본으로 하는 프로그래머블 제어기에 관한 연구 (A programmable controller based on the memory-based implementation of a binary-petri net)

  • 장래혁;박재현;노갑선;권욱현
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1993년도 한국자동제어학술회의논문집(국내학술편); Seoul National University, Seoul; 20-22 Oct. 1993
    • /
    • pp.342-347
    • /
    • 1993
  • For a fast evolution, a memory-based implementation of a petri net is discussed. A sub-class petri net model called B-petri net is suggested to make a memory-based implementation feasible in a large size application. The suggested B-petri net is a binary-petri net since only a binary-typed decision, fork and join are allowed. The application of a B-petri nt is focused to a SFC(sequential function chart) program. The memory requirement, speed and computational load are compared with a petri net when they are implementated by a memory-based method.

  • PDF

가스터빈 동기기 통합형 기동 및 여자시스템 개발 (Development of Integrated Start-up and Excitation System for Gas Turbine Synchronous Generator)

  • 류호선;차한주
    • 전기학회논문지P
    • /
    • 제63권3호
    • /
    • pp.183-188
    • /
    • 2014
  • Power conversion systems used in large gas turbine power plant can be divided into two main part. Because of the initial start-up characteristic of the gas turbine combustor, the gas turbine must be accelerated by starting device(LCI : Load Commutated Inverter) up to 10%~20% of rated speed to ignite it. In addition, the ECS(Excitation Control system) is used to control the rotor field current and reactive power in grid-connected synchronous generator. These two large power conversion systems are located in the same space(container) because of coordination control. Recently, many manufactures develop high speed controller based on function block available in the LCI and ECS with the newest power semiconductor. We also developed high speed controller based on function block to be using these two system and it meets the international standard IEC61131 as using real-time OS(VxWorks) and ISaGRAF. In order to install easily these systems at power plant, main controller, special module and IO module are used with high speed communication line other than electric wire line. Before initial product is installed on the site, prototype is produced and tests are conducted for it. The performance results of Integrated controller and application program(SFC, ECS) were described in this paper. The test results will be considered as the important resources for the application in future.