• 제목/요약/키워드: SEM $T_g

검색결과 162건 처리시간 0.027초

Corrosion Characteristics of Cell-Covered Ternary Ti-Nb-Ta Alloy for Biomaterials

  • Kim, W.G.;Yu, J.W.;Choe, H.C.;Ko, Y.M.;Park, G.H.
    • Corrosion Science and Technology
    • /
    • 제8권2호
    • /
    • pp.62-67
    • /
    • 2009
  • Ti and Ti-alloys have good biocompatibility, appropriate mechanical properties and excellent corrosion resistance. However, the widely used Ti-6Al-4V is found to release toxic ions (Al and V) into the body, leading to undesirable long-term effects. Ti-6Al-4V has much higher elastic modulus (100 GPa) than cortical bone (20 GPa). Therefore, titanium alloys with low elastic modulus have been developed as biomaterials to minimize stress shielding. The electrochemical behavior of surface-modified and MC3T3-E1 cell-cultured Ti-30(Nb,Ta) alloys with low elastic modulus have been investigated using various electrochemical methods. Surfaces of test samples were treated as follows: $0.3{\mu}m$ polished; $25{\mu}m$, $50{\mu}m$ and $125{\mu}m$ sandblasted. Specimen surfaces were cultured with MC3T3-E1 cells for 2 days. Average surface roughness ($R_a$) and morphology of specimens were determined using a surface profilometer, OM, and FE-SEM. Corrosion behavior was investigated using a potentiostat(EG&G PARSTAT 2273), and electrochemical impedance spectroscopy was performed (10 mHz to 100 kHz) in 0.9% NaCl solution at $36.5{\pm}1^{\circ}C$. The microstructures of the Ti-30(Ta,Nb) alloys had a needle-like appearance. The $R_a$ of polished Ti-30Ta and Ti-30Nb alloys was lower than that of the sandblasted Ti alloy. Cultured cells displayed round shapes. For polished alloy samples, cells were well-cultured on all surfaces compared to sandblasted alloy samples. In sandblasted and cell-cultured Ti-30(Nb,Ta) alloy, the pitting potential decreased and passive current density increased as $R_a$ increased. Anodic polarization curves of cell-cultured Ti alloys showed unstable behavior in the passive region compared to non-cell-cultured alloys. From impedance tests of sandblasted and cell-cultured alloys, the polarization resistance decreased as $R_a$ increased, whereas, $R_a$ for cell-cultured Ti alloys increased compared to non-cell-cultured Ti alloys.

알루미늄 발포용 TiH2/TiH2-Al의 제조와 수소화 특성 평가 (Fabrication and Evaluations of Hydrogenation Properties of TiH2/TiH2-Al agents on Aluminum Foam Alloy)

  • 홍태환;조경원;권순용;김일호;이정일;어순철;이영근;류성림
    • 한국수소및신에너지학회논문집
    • /
    • 제15권3호
    • /
    • pp.235-243
    • /
    • 2004
  • A number of potential applications of aluminum foams are being identified and renewed interest in these engineering materials is also reflected by several current research projects. One of the key issues for industrial exploitation of aluminum foams is the development of cost-effective manufacturing strategies facilitating, preferably, net shape production of foams with controlled porosity and cell size, and minimized structural imperfection. Especially, melt route to aluminum foam production based on the foaming agents offer attraction of low cost and the potential for good microstructure. The present paper is focused mainly on foaming agents of melt-foam aluminum such as $TiH_2$ or $TiH_2-Al$ mixture. For the purpose of economical manufacturing, we are proposed to hydrogen induced mechanical alloying (HIMA) process. Thermo-physical properties of particles synthesized are compared with conventional methods. Specimens synthesized are characterized by scanning electron microscopy (SEM) with energy dispersive spectroscopy (EDS), thermo- gravimetry-differential scanning calorymetry (TG-DSC), pressure-composition-isotherm. (PCI).

Influence of polishing systems on roughness and color change of two dental ceramics

  • Maciel, Lucas Campagnaro;Silva, Carlos Frederico Bettcher;de Jesus, Ricardo Huver;da Silva Concilio, Lais Regiane;Kano, Stefania Carvalho;Xible, Anuar Antonio
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권4호
    • /
    • pp.215-222
    • /
    • 2019
  • PURPOSE. To evaluate the polishing effect on roughness and color change of pressed and layering ceramics after immersion in coffee solution. MATERIALS AND METHODS. 88 ceramic discs ($1.0mm{\times}10.0mm$) were manufactured - 44 nano-fluorapatite layering ceramics (IPS e.max Ceram. Group C) and 44 pressed lithium disilicate ceramic discs (IPS e. max Press - Group P). Each group was divided into 4 subgroups according to surface treatments: (G) Glaze, (S) Shofu polishing system (Shofu Inc.), (E) Edenta AG polishing System, (KG) $30-{\mu}m$ diamond granulation tip. Surface roughness (Ra) and color change (${\Delta}E$) measurings after the surface treatments were performed, before and 12 days after the immersion in coffee solution. A samples' qualitative analysis was conducted with a scanning electron microscopy (SEM). Data were statistically-treated with one-way-ANOVA and Duncan's tests, apart from paired t-test and Pearson's correlation test (${\alpha}=5%$). RESULTS. The decrescent order, both for surface roughness (Ra) and ${\Delta}E$ for both ceramics were: KG > E > S > G (P<.05). With exception for PG and CG subgroups, which did not present statistical difference between them, all other pressed ceramics subgroups presented smaller Ra values and greater ${\Delta}E$ values than the layering ceramics subgroups (P<.05). CONCLUSION. Although mechanical polishing systems presented intermediate Ra values, their colors were considered clinically acceptable. There is a strong correlation between the surface roughness and the color change of tested ceramics.

리튬이차전지 음극재용 나노입자 Li4Ti5O12의 전기화학적 연구 (Electrochemical Study of Nanoparticle Li4Ti5O12 as Negative Electrode Material for Lithium Secondary Battery)

  • 오미현;김한주;김영재;손원근;임기조;박수길
    • 전기화학회지
    • /
    • 제9권1호
    • /
    • pp.1-5
    • /
    • 2006
  • 리튬이온전지용 음극 활물질로 스피넬 구조의 리튬 티탄산화물$(Li_4Ti_5O_{12})$이 졸겔법과 HEBM법으로 제조되었다. 제조된 $Li_4Ti_5O_{12}$의 입자크기 및 결정구조를 확인하기 위하여 X-선 회절분석(XRD), 주사전자현미경(SEM) 및 평균입자분석(PSA)을 수행한 결과 100nm의 균일한 크기의 입자를 확인하였다. 작업전극으로 $Li_4Ti_5O_{12}$를 사용하고 기준전극과 상대전극으로 lithium 호일을 사용하여 전기화학적인 삼상전극 셀을 구성하여 전기화학적인 특성 평가를 한 결과 $1.0\sim2.5V$의 전압 범위에서 고율 충 방전 성능과 0.2C에서 173mAh/g의 용량 특성을 나타내었다. $Li_4Ti_5O_{12}$은 리튬의 삽입과 탈리가 일어나는 동안 구조적인 안정성을 보여주고 있다.

HDPE/EPDM/Boron Carbide/Triphenyl Phosphate 블렌드의 상용화제 첨가에 따른 난연성 및 기계적 물성 연구 (A Study on Flammability and Mechanical Properties of HDPE/EPDM/Boron Carbide/Triphenyl Phosphate Blends with Compatibilizer)

  • 신범식;정승태;전준표;김현빈;오승환;강필현
    • 폴리머
    • /
    • 제36권5호
    • /
    • pp.549-554
    • /
    • 2012
  • 난연제 triphenyl phosphate는 HDPE(high-density polyethylene)/EPDM(ethylene-propylene diene monomer)/boron carbide 내에서 miscibility가 좋지 못하여 고분자의 기계적 물성을 크게 저하시킨다. HDPE/EPDM/boron carbide/triphenyl phosphate 블렌드의 분산성을 향상시키기 위해서 상용화제로 PE-g-MAH(polyethylene-graft-maleic anhydride)를 사용하여 블렌딩하였다. Triphenyl phosphate 함량이 증가할수록 인장강도를 크게 저하시킴을 확인하였다. 하지만 상용화제 첨가로 인하여 기계적 물성이 향상되는 것을 확인하였다. Triphenyl phosphate의 분산성의 향상은 SEM 분석을 통해서 확인하였다. HDPE/EPDM/boron carbide/triphenyl phosphate의 내열성과 난연성을 측정하기 위해서 TGA 분석과 LOI 분석을 진행하였다. 분산성이 향상됨에 따라서 triphenyl phosphate 첨가제의 기본적인 특성인 내열성과 난연성이 향상되었으며, 그 결과로 자기 소화성인 21% 이상의 한계산소지수(LOI)를 가지는 HDPE/EPDM/boron carbide/triphenyl phosphate 블렌드를 얻을 수 있었다.

In vitro performance and fracture resistance of novel CAD/CAM ceramic molar crowns loaded on implants and human teeth

  • Preis, Verena;Hahnel, Sebastian;Behr, Michael;Rosentritt, Martin
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권4호
    • /
    • pp.300-307
    • /
    • 2018
  • PURPOSE. To investigate the fatigue and fracture resistance of computer-aided design and computer-aided manufacturing (CAD/CAM) ceramic molar crowns on dental implants and human teeth. MATERIALS AND METHODS. Molar crowns (n=48; n=8/group) were fabricated of a lithium-disilicate-strengthened lithium aluminosilicate glass ceramic (N). Surfaces were polished (P) or glazed (G). Crowns were tested on human teeth (T) and implant-abutment analogues (I) simulating a chairside (C, crown bonded to abutment) or labside (L, screw channel) procedure for implant groups. Polished/glazed lithium disilicate (E) crowns (n=16) served as reference. Combined thermal cycling and mechanical loading (TC: $3000{\times}5^{\circ}C/3000{\times}55^{\circ}C$; ML: $1.2{\time}10^6$ cycles, 50 N) with antagonistic human molars (groups T) and steatite spheres (groups I) was performed under a chewing simulator. TCML crowns were then analyzed for failures (optical microscopy, SEM) and fracture force was determined. Data were statistically analyzed (Kolmogorow-Smirnov, one-way-ANOVA, post-hoc Bonferroni, ${\alpha}=.05$). RESULTS. All crowns survived TCML and showed small traces of wear. In human teeth groups, fracture forces of N crowns varied between $1214{\pm}293N$ (NPT) and $1324{\pm}498N$ (NGT), differing significantly ($P{\leq}.003$) from the polished reference EPT ($2044{\pm}302N$). Fracture forces in implant groups varied between $934{\pm}154N$ (NGI_L) and $1782{\pm}153N$ (NPI_C), providing higher values for the respective chairside crowns. Differences between polishing and glazing were not significant ($P{\geq}.066$) between crowns of identical materials and abutment support. CONCLUSION. Fracture resistance was influenced by the ceramic material, and partly by the tooth or implant situation and the clinical procedure (chairside/labside). Type of surface finish (polishing/glazing) had no significant influence. Clinical survival of the new glass ceramic may be comparable to lithium disilicate.

Doped Sol-gel TiO2 Films for Biological Applications

  • Gartner, M.;Trapalis, C.;Todorova, N.;Giannakopoulou, T.;Dobrescu, G.;Anastasescu, M.;Osiceanu, P.;Ghita, A.;Enache, M.;Dumitru, L.;Stoica, T.;Zaharescu, M.;Bae, J.Y.;Suh, S.H.
    • Bulletin of the Korean Chemical Society
    • /
    • 제29권5호
    • /
    • pp.1038-1042
    • /
    • 2008
  • Mono and multilayer TiO2(Fe, $PEG_{600}$) films were deposited by the dip-coating on $SiO_2$/glass substrate using sol-gel method. In an attempt to improve the antibacterial properties of doped $TiO_2$ films, the influence of the iron oxides and polyethilenglycol ($PEG_{600}$) on the morphological, optical, surface chemical composition and biological properties of nanostructured layers was studied. Complementary measurements were performed including Spectroscopic Ellipsometry (SE), Scanning Electron Microscopy (SEM) coupled with the fractal analysis, X-Ray Photoelectron Spectroscopy (XPS) and antibacterial tests. It was found that different concentrations of Fe and $PEG_{600}$ added to coating solution strongly influence the porosity and morphology at nanometric scale related to fractal behaviour and the elemental and chemical states of the surfaces as well. The thermal treatment under oxidative atmosphere leads to films densification and oxides phase stabilization. The antibacterial activity of coatings against Escherichia Coli bacteria was examined by specific antibacterial tests.

습식방사 된 PVDF 섬유의 후 처리를 통한 결정구조의 변화 (The Effects of Post-Treatments for Wet Spun PVDF on the Piezoelectric Property)

  • 유성미;오현주;황상균;정용식;황희윤;김성수
    • Composites Research
    • /
    • 제26권2호
    • /
    • pp.123-128
    • /
    • 2013
  • PVDF(polyvinylidene fluoride) 섬유는 습식방사방법을 적용하여 제조하였다. PVDF 분자 내 압전 특성과 밀접한 관련을 갖는 ${\beta}$형태의 결정 함량을 높이기 위하여, 본 연구에서는 습식방사 된 섬유에 1단계 연신, 2단계 어닐링 공정으로 구성하여 후 처리를 도입하였다. 후 처리는 PVDF 고분자의 유리전이 온도($T_g$)와 용융온도($T_m$) 사이의 온도범위에서 진행하여, 최대의 ${\beta}$형태 결정을 생성 할 수 있는 열처리 조건을 최적화 하였다. 제조된 PVDF 섬유 내 분자 배향 특성과 결정 구조를 확인하기 위하여 적외선 분광 광도계(FT-IR)와 X선 회절 분석기(XRD)를 이용하여 분석하였으며, 전자현미경(SEM)을 통하여 섬유의 표면을 관찰하여 섬유의 평균직경을 확인하였다. 분석 결과, 후 처리 공정이 PVDF 결정 구조의 영향을 미치며, ${\beta}$형태의 결정 비율을 증가시킨다는 것을 확인하였다. 더불어 ${\beta}$형태 결정 향상으로 인해 기계적 강도가 증가되었으며, 압전 특성 향상까지 기대할 수 있었다.

Wind-induced responses and equivalent static wind loads of tower-blade coupled large wind turbine system

  • Ke, S.T.;Wang, T.G.;Ge, Y.J.;Tamura, Y.
    • Structural Engineering and Mechanics
    • /
    • 제52권3호
    • /
    • pp.485-505
    • /
    • 2014
  • This study aimed to develop an approach to accurately predict the wind models and wind effects of large wind turbines. The wind-induced vibration characteristics of a 5 MW tower-blade coupled wind turbine system have been investigated in this paper. First, the blade-tower integration model was established, which included blades, nacelle, tower and the base of the wind turbine system. The harmonic superposition method and modified blade element momentum theory were then applied to simulate the fluctuating wind field for the rotor blades and tower. Finally, wind-induced responses and equivalent static wind loads (ESWL) of the system were studied based on the modified consistent coupling method, which took into account coupling effects of resonant modes, cross terms of resonant and background responses. Furthermore, useful suggestions were proposed to instruct the wind resistance design of large wind turbines. Based on obtained results, it is shown from the obtained results that wind-induced responses and ESWL were characterized with complicated modal responses, multi-mode coupling effects, and multiple equivalent objectives. Compared with the background component, the resonant component made more contribution to wind-induced responses and equivalent static wind loads at the middle-upper part of the tower and blades, and cross terms between background and resonant components affected the total fluctuation responses, while the background responses were similar with the resonant responses at the bottom of tower.

Analytical study of composite steel-concrete beams with external prestressing

  • Turini, Thiago T.;Calenzani, Adenilcia F.G.
    • Structural Engineering and Mechanics
    • /
    • 제82권5호
    • /
    • pp.595-609
    • /
    • 2022
  • Prestressed composite steel-concrete beams are still a technology restricted to repair sites of large-scale structures and spans. One of the reasons for that is the absence of standard frameworks and publications regarding their design and implementation. In addition, the primary normative codes do not address this subject directly, which might be related to a scarcity of papers indicating methods of design that would align the two technics, composite beams and external prestressing. In this context, this paper proposes methods to analyze the sizing of prestressed composite beams submitted to pre-tension and post-tension with a straight or polynomial layout cable. This inquiry inspected a hundred and twenty models of prestressed composite beams according to its prestressing technology and the eccentricity and value of the prestressing force. The evaluation also included the ratio between span and height of the steel profile, thickness and typology of the concrete slab, and layout of the prestressing cables. As for the results, it was observed that the eccentricity of the prestressing force doesn't significantly influence the bending resistance. In prestressed composite beams subjected to a sagging moment, the ratio L/d can reach 35 and 30 for steel-concrete composite slabs and solid concrete slabs, respectively. Considering the negative bending moment resistance, the value of the L/d ratio must be less than or equal to 25, regardless of the type of slab. When it comes to the value of the prestressing force, a variation greater than 10% causes a 2.6% increase in the positive bending moment resistance and a 4% decrease in the negative bending moment resistance. The pre-tensioned composite beams showed a superior response to flexural-compression and excessive compression limit states than the post-tensioned ones.