• 제목/요약/키워드: SDOF

검색결과 225건 처리시간 0.03초

일방향 철근 콘크리트 슬래브의 폭발 피해 기준에 대한 실험적 분석 (Experimental Analysis on the Criteria of the Explosion Damage for One-way RC Slabs)

  • 이승재;박종일;이영학;김희식
    • 한국안전학회지
    • /
    • 제32권6호
    • /
    • pp.68-74
    • /
    • 2017
  • To predict the damage of Reinforced Concrete (RC) structures from mass explosion, Pressure-Impulse (P-I) curves representing the relationship between peak pressure and impulse based on damage criteria are essential. There are P-I curves developed by the U.S. DoD without detailed explanation regarding validation. In this study, full scale explosion tests were conducted measuring response of RC slab to modify and validate pre-existing P-I curves. Four same RC slabs were prepared, and placed at different distances, which are fixed to steel frame with concrete base. Scaled distances were selected to show different failure types using P-I curve based on Single Degree Of Freedom (SDOF) model. It was found that SDOF model can be used to evaluate and identify one-way RC slab damage with difference damage criteria.

Closed-form optimum tuning formulas for passive Tuned Mass Dampers under benchmark excitations

  • Salvi, Jonathan;Rizzi, Egidio
    • Smart Structures and Systems
    • /
    • 제17권2호
    • /
    • pp.231-256
    • /
    • 2016
  • This study concerns the derivation of optimum tuning formulas for a passive Tuned Mass Damper (TMD) device, for the case of benchmark ideal excitations acting on a single-degree-of-freedom (SDOF) damped primary structure. The free TMD parameters are tuned first through a non-linear gradient-based optimisation algorithm, for the case of harmonic or white noise excitations, acting either as force on the SDOF primary structure or as base acceleration. The achieved optimum TMD parameters are successively interpolated according to appropriate analytical fitting proposals, by non-linear least squares, in order to produce simple and effective TMD tuning formulas. In particular, two fitting models are presented. The main proposal is composed of a simple polynomial relationship, refined within the fitting process, and constitutes the optimum choice. A second model refers to proper modifications of literature formulas for the case of an undamped primary structure. The results in terms of final (interpolated) optimum TMD parameters and of device effectiveness in reducing the structural dynamic response are finally displayed and discussed in detail, showing the wide and ready-to-use validity of the proposed optimisation procedure and achieved tuning formulas. Several post-tuning trials have been carried out as well on SDOF and MDOF shear-type frame buildings, by confirming the effective benefit provided by the proposed optimum TMD.

Direct displacement-based design accuracy prediction for single-column RC bridge bents

  • Tecchio, Giovanni;Dona, Marco;Modena, Claudio
    • Earthquakes and Structures
    • /
    • 제9권3호
    • /
    • pp.455-480
    • /
    • 2015
  • In the last decade, displacement-based (DB) methods have become established design procedures for reinforced concrete (RC) structures. They use strain and displacement measures as seismic performance control parameters. As for other simplified seismic design methods, it is of great interest to prove if they are usually conservative in respect to more refined, nonlinear, time history analyses, and can estimate design parameters with acceptable accuracy. In this paper, the current Direct Displacement-Based Design (DDBD) procedure is evaluated for designing simple single degree of freedom (SDOF) systems with specific reference to simply supported RC bridge piers. Using different formulations proposed in literature for the equivalent viscous damping and spectrum reduction factor, a parametric study is carried out on a comprehensive set of SDOF systems, and an average error chart of the method is derived allowing prediction of the expected error for an ample range of design cases. Following the chart, it can be observed that, for the design of actual RC bridge piers, underestimation errors of the DDBD method are very low, while the overestimation range of the simplified displacement-based procedure is strongly dependent on design ductility.

The numerical solution of dynamic response of SDOF systems using cubic B-spline polynomial functions

  • Shojaee, S.;Rostami, S.;Moeinadini, A.
    • Structural Engineering and Mechanics
    • /
    • 제38권2호
    • /
    • pp.211-229
    • /
    • 2011
  • In this paper, we present a new explicit procedure using periodic cubic B-spline interpolation polynomials to solve linear and nonlinear dynamic equation of motion governing single degree of freedom (SDOF) systems. In the proposed approach, a straightforward formulation was derived from the approximation of displacement with B-spline basis in a fluent manner. In this way, there is no need to use a special pre-starting procedure to commence solving the problem. Actually, this method lies in the case of conditionally stable methods. A simple step-by-step algorithm is implemented and presented to calculate dynamic response of SDOF systems. The validity and effectiveness of the proposed method is demonstrated with four examples. The results were compared with those from the numerical methods such as Duhamel integration, Linear Acceleration and also Exact method. The comparison shows that the proposed method is a fast and simple procedure with trivial computational effort and acceptable accuracy exactly like the Linear Acceleration method. But its power point is that its time consumption is notably less than the Linear Acceleration method especially in the nonlinear analysis.

Shaking table tests on a SDOF structure with cylindrical and rectangular TLDs having rotatable baffles

  • Zahrai, Seyed Mehdi;Kakouei, Sirous
    • Smart Structures and Systems
    • /
    • 제24권3호
    • /
    • pp.391-401
    • /
    • 2019
  • Control of vibrations against extraordinary excitations such as wind and earthquake is very important to the protection of life and financial concerns. One of the methods of structural control is to use Tuned Liquid Damper (TLD), however due to the nature of TLD only one sloshing frequency can be created when the water is sloshing. Among various ideas proposed to compensate this problem, by changing the angle of some rotatable baffles embedded inside a TLD, a frequency range is created such that these baffles are tuned manually at different frequencies. In this study, the effect of cross sectional shape of container with rotating baffles on seismic behavior of TLD is experimentally studied. For this purpose, rectangular and cylindrical containers are designed and used to suppress the vibrations of a Single Degree-Of-Freedom (SDOF) structure under harmonic and earthquake excitations considering three baffle angles. The results show that the rectangular-shaped damper reduces the structural response in all load cases more than the damper with a cylindrical shape, such that maximum differences of two dampers to reduce the structural displacement and structural acceleration are 5.5% and 3% respectively, when compared to the cases where no baffles are employed.

An investigation on the maximum earthquake input energy for elastic SDOF systems

  • Merter, Onur
    • Earthquakes and Structures
    • /
    • 제16권4호
    • /
    • pp.487-499
    • /
    • 2019
  • Energy-based seismic design of structures has gradually become prominent in today's structural engineering investigations because of being more rational and reliable when it is compared to traditional force-based and displacement-based methods. Energy-based approaches have widely taken place in many previous studies and investigations and undoubtedly, they are going to play more important role in future seismic design codes, too. This paper aims to compute the maximum earthquake energy input to elastic single-degree-of-freedom (SDOF) systems for selected real ground motion records. A data set containing 100 real ground motion records which have the same site soil profiles has been selected from Pacific Earthquake Research (PEER) database. Response time history (RTH) analyses have been conducted for elastic SDOF systems having a constant damping ratio and natural periods of 0.1 s to 3.0 s. Totally 3000 RTH analyses have been performed and the maximum mass normalized earthquake input energy values for all records have been computed. Previous researchers' approaches have been compared to the results of RTH analyses and an approach which considers the pseudo-spectral velocity with Arias Intensity has been proposed. Graphs of the maximum earthquake input energy versus the maximum pseudo-spectral velocity have been obtained. The results show that there is a good agreement between the maximum input energy demands of RTH analysis and the other approaches and the maximum earthquake input energy is a relatively stable response parameter to be used for further seismic design and evaluations.

구조물의 회복탄력성 기반 성능평가법에 대한 고찰 및 적용 방안에 관한 연구 (A Study on the Resilience-Based Performance Evaluation Method of Structures and Their Application Plan)

  • 김유성;강주원;이준호
    • 한국공간구조학회논문집
    • /
    • 제20권4호
    • /
    • pp.159-167
    • /
    • 2020
  • The resilience performance evaluation method of a structure can evaluate the ability to recover after an earthquake disaster, and this study deals with the consideration and introduction of the resilience performance evaluation method. The resilience evaluation method can be expressed as a quantified number by constructing a loss estimation model and a recovery evaluation model. The recovery evaluation model should consider downtime in addition to the repair time, and the loss estimation model should consider not only direct loss to structures and non-structures, but also indirect loss due to functional loss of the building. In addition, to build a loss estimation model, the structure should be simplified to perform an efficient analysis. Therefore, in this study, the equivalent terminal induction system proposed cantilever-type and rahmen-type SDOF, and it is evaluated somewhat conservatively compared to the example structure, and it is judged that there is a need to improve the hysteresis characteristics by applying the stiffness reduction factor of the SDOF model.

Accuracy assessment of real-time hybrid testing for seismic control of an offshore wind turbine supporting structure with a TMD

  • Ging-Long Lin;Lyan-Ywan Lu;Kai-Ting Lei;Shih-Wei Yeh;Kuang-Yen Liu
    • Smart Structures and Systems
    • /
    • 제31권6호
    • /
    • pp.601-619
    • /
    • 2023
  • In this study, the accuracy of a real-time hybrid test (RTHT) employed for a performance test of a tuned mass damper (TMD) on an offshore wind turbine (OWT) with a complicated jacket-type supporting structure is quantified and evaluated by comparing the RTHT results with the experimental data obtained from a shaking table test (STT), in which a 1/25-scale model for a typical 5-MW OWT controlled by a TMD was tested. In the RTHT, the jacket-type OWT structure was modelled using both multiple-DOF (MDOF) and single-DOF (SDOF) numerical models. When compared with the STT test data, the test results of the RTHT show that while the SDOF model, which requires less control computational time, is able to well predict the peak responses of the nacelle and TMD only, the MDOF model is able to effectively predict both the peak and over-all time-history responses at multiple critical locations of an OWT structure. This also indicates that, depending on the type of structural responses considered, an RTHT with either an SDOF or a MDOF model may be a promising alternative to the STT to assess the effectiveness of a TMD for seismic mitigation in an OWT context.

철골 연성 모멘트 골조의 연성계수 및 강도계수 평가 (Evaluation of Ductility and Strength Factors for Special Steel Moment Resisting Frames)

  • 강철규;최병정
    • 한국강구조학회 논문집
    • /
    • 제16권6호통권73호
    • /
    • pp.793-805
    • /
    • 2004
  • 본 연구에서는 철골 연성 모멘트 골조에 대하여 반응수정계수(R)의 핵심 구성요소인 연성계수 및 강도계수를 평가하였다. 철골 연성 모멘트 골조에 대한 연성계수($R_{{\mu},MDOF}$) 는 단자유도 구조물에 대한 연성계수($R_{{\mu},SDOF}$)에 다자유도 보정계수($R_M$)를 곱하여 산정하였다. 단자유도 구조물에 대한 연성계수($R_{{\mu},SDOF}$)는 지진하중을 받는 탄소성 단자유도(SDOF) 구조물의 목표 변위 연성비와 주기에 따른 비선형 동적해석으로부터 산정하였다. 통계적 연구와 회귀분석으로부터 연성계수를 산정하기 위한 평가식이 제시되었다. 다자유도의 영향을 고려하기 위한 보정계수($R_M$)는 기존의 연구결과로보터 회귀분석을 이용하여 구하였다. 철골 연성 모멘트 골조에 대한 강도계수는 비선형 정적해석으로부터 산정하였다. 철골 연성 모멘트 골조의 연성 계수 및 강도계수를 평가하기 위하여, 구조물의 층수(4, 8 및 16층), 지진구역계수(Z=0.075, 0.2 및 0.4), 골조 시스템(외곽골조 및 분배골조) 및 붕괴 메카니즘(강기둥-약보 및 약기둥-강보)을 설계 매개변수로 하여 총 36개의 예제구조물을 설계하였다. 철골 연성 모멘트 골조의 연성계수 및 강도계수에 이러한 설계 매개변수가 미치는 영향을 분석하였다.

Parametric Analysis and Design of SDOF Vibration-Type Triboelectric Generator

  • ;전지훈;최덕현
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.398-398
    • /
    • 2016
  • A triboelectric generator uses the principles of static electrification and electrostatic induction to convert mechanical energy into useful electrical energy. In this work we study a single degree of freedom (SDOF) vibration type triboelectric generator that is initiated by a vibrating source at its base. The system is modeled in Abaqus and the design parameters are systematically explored by their effect on the output. The relationships between the parameters: input force, input frequency, mass, spring stiffness and gap between the plates, are analyzed. Finally, based on initial experiments, and simulation results, a design methodology is formulated. The methodology will provide guidance for application specific design of reliable and effective vibration type triboelectric generators.

  • PDF