• Title/Summary/Keyword: S-STEP

Search Result 6,416, Processing Time 0.037 seconds

Efficient Scientific Computation on WP Parallel Computer (MP 병렬컴퓨터에서 효과적인 과학계산의 수행)

  • 김선경
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.8 no.4
    • /
    • pp.26-30
    • /
    • 2003
  • The Lanczos algorithm is the most commonly used in approximating a small number of extreme eigenvalues for symmetric large sparse matrices. Global communications in MP(Message Passing) parallel computer decrease the computation speed. In this paper, we introduce the s-step Lanczos method, and s-step method generates reduction matrices which are similar to reduction matrices generated by the standard Lanczos method. One iteration of the s-step Lanczos algorithm corresponds to s iterations of the standard Lanczos algorithm. The s-step method has the minimized global communication and has the superior parallel properties to the standard method. These algorithms are implemented on Cray T3E and performance results are presented.

  • PDF

The Effect of Heat Treatment on Shrinkage and Mechanical Properties of PET Filament (섬유공정에서의 습.건열처리가 PET 필라멘트사의 열수축과 인장특성에 미치는 영향)

  • 김경렬;김승진;김태훈;김영진;이응곤;송재수
    • Textile Coloration and Finishing
    • /
    • v.10 no.3
    • /
    • pp.10-19
    • /
    • 1998
  • This paper investigates the change of mechanical properties and thermal shrinkage in commercial multi-filament PET(polyethylene terephthalate) , namely, regular yarn, POY, DTY and composite yarn. To determine changing the effects of processing steps, these were examined at three steps process simulation conditions. The first step is sizing simulation$(S-1\;step\;:\;130^\circ{C}\times2\;min$., hot air treatment under 0.1 gf/d load), the second step is scouring simulation$(S-2\;step\;:\;100^\circ{C}\times20\;min$., boiling water treatment under free tension)and final step is setting simulation$(S-3\;step\;:\;180^\circ{C}\times2\;min$., hot air treatment under free tension). Regular yarn in multi-step treatment showed higher shrinkage at S-3 step and DTY showed higher in at S-1 step. While POY was relaxed at S-1 step, composite yarn showed different shrinkage properties depending on composite yarn type. Mechanical properties showed good relationship with shrinkage : high shrinkage makes initial modulus decrease and bleating strain increase. It also makes decreasing yield strain and yield stress decrease.

  • PDF

Efficient s-step GMRES Algorithm on a Message Passing Parallel System (Message Passing Parallel System에서 효과적인 s-step GMRES 알고리즘)

  • 김선경
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2000.11a
    • /
    • pp.484-488
    • /
    • 2000
  • 병렬 컴퓨터를 사용하는 경우 하드웨어만으로 모든 것이 해결되지 않으며 병렬처리 기법의 도입이 불가피하다. 효과를 극대화하기 위하여서는 각 병렬 컴퓨터의 하드웨어적인 특징을 극대화할 수 있는 병렬 알고리즘과 병렬 프로그램 등 소프트웨어 개발이 필수적이다. GMRES(Generalized Minimal residual) 방법은 아주 큰 대칭 또는 비대칭 선형시스템의 해를 구하는 반복법 중의 하나로 일반적으로 많이 사용되고 있다. 서로 직교인 벡터를 하나씩 구하는 대신에 선형인 s개의 벡터를 구하고 각 그룹간에는 직교가 되게하는 s-step GMRES 알고리즘은 병렬적 성질을 더 많이 가지고 있다. 이 병렬 알고리즘의 전반부는 이미 개발된 s-step Arnoldi 알고리즘을 이용할 수 있다. s-step GMRES 알고리즘은 message passing 병렬 시스템에서 모든 프로세서들 사이의 자료 교환 시간을 줄임으로써 기존의 GMRES 방법에 비해 훨씬 더 병렬성을 증가시킨다. 본 논문에서는 초병렬 시스템(MPP)인 Cray T3E에서 많은 프로세서를 이용할 경우 개발된 s-step 알고리즘이 기존의 알고리즘에 비하여 얼마나 더 효과적으로 빨리 수행될 수 있는지 분석한다.

  • PDF

Evaluation of the usefulness of Bolus, which combines Step Bolus and 3D Bolus (Step Bolus와 3D Bolus를 combine 한 Bolus의 유용성 평가)

  • Lee, Chang-Suk;Chae, Moon-Ki;Park, Byung-Suk;Kim, Sung-Jin;Joo, Kyoo-Sang;Park, Chul-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.79-88
    • /
    • 2021
  • Objectives: Bolus, which combines 3D-bolus and Step-bolus, was produced and its usefulness is evaluated. Materials and Methods: A Bolus was manufactured with a thickness of 10mm and 5mm using a 3D printer (3D printer, USA), and a Step Bolus of 5mm was bonded to a 5mm thick bolus. In order to understand the characteristics of Step bolus and 3D bolus, the differences in relative electron density, HU value, and mass density of the two bolus were investigated. These two Bolus were applied to anthropomorpic phantom to confirm its effectiveness. After all contouring of the phantom, a treatment plan was established using the computed treatment planning system (Eclipse 16.1, Varian medical system, USA). Treatment plan was performed using electron beam 6MeV, nine dose measurement points were designated on the phantom chest, air-gap was measured at that point, and dose evaluation was performed at the same point for each bolus applied using a glass dosimeter (PLD). Results: Bolus, which combines 3D-bolus 5mm and Step-bolus 5mm, was manufactured and evaluated compared with 3D-bolus 1cm. The relative electron density of 3D Bolus was 1.0559 g/cm2 and the step Bolus was 1.0590 g/cm2, which was different by 0.01%, so the relative electron density was almost the same. In the lightweight measurement of air-gap, the combined bolus was reduced to 54.32% for all designated points compared to 3D-bolus. In the dose measurement using a glass dose meter (PLD), the consistency was high in phantom using combined bolus at most points except the slope point. Conclusion: Combined bolus made by combining 3D-bolus and Step-bolus has all the advantages of 3D-bolus and Step-bolus. In addition, by dose inaccuracy due to Air-gap, more improved dose distribution can be shown, and effective radiation therapy can be performed.

Preparation of a axis oriented $YBa_2Cu_3O_{7-\delta}$ thin films by RF magnetron sputtering (RF 마그네트론 스퍼터링법에 의한 a-축 배향 $YBa_2Cu_3O_{7-\delta}$박막의 제조)

  • Lee, J.J.;Kim, Y.H.;Shin, J.;Lee, K.H.;Choi, S.S.;Hahn, T.S.
    • Korean Journal of Materials Research
    • /
    • v.4 no.4
    • /
    • pp.459-465
    • /
    • 1994
  • A-axis oriened YBCO thin flims were grown on $LaAIO_{3}$ single crystal substrate by off-axis rf magnetron sputtering method. We used two kinds of process to get a-axis oriented fi1ms;one-step process and two-step process. In one-step process, films are grown in single step in which substrate temperature( $T_s$) is in the range of $590^{\circ}C$ to $680^{\circ}C$. On the other hand, in two step process a-axis oriented thin film templates i f about 30nm thickness is deposited at low temperature first, and subsequently films are grown at elevated temperature to the final thickness of about 100nm. In the case of one step process($T_s$ ~)$600^{\circ}C$), prefered a-axis orientation is dominant and Cu-rich phases segregate at the surface. Segregations decrease and ($00 \ell$) peaks increase upon increasing $T_s$. The films prepared by two step method appeared to have strong(h00) peaks as the deposition rate increased. Microstructure shows pin holes resulted from mixed phases of a-axis and c-axis oriented films. In both cases of one step and two step process, as TS decreases, prepared films show stronger a-axis orientation. However electrical properties of the films are depressed with lower $T_c$ and wider $\Delta T$ as $T_s$ decreases.

  • PDF

Preliminary Analysis on Characteristics of Attitude Control based on Operation Scenario of Small SAR Satellite Mission, S-STEP (초소형 SAR 위성 S-STEP의 임무 시나리오에 따른 자세 제어 성능 예비 분석)

  • Lee, Eunji;Park, Jinhan;Song, Sung-Chan;Oh, Hyun-Ung
    • Journal of Aerospace System Engineering
    • /
    • v.16 no.5
    • /
    • pp.49-56
    • /
    • 2022
  • S-STEP is a small SAR satellite mission that monitors time-limited emergency targets and military anomalies in areas of interest, achieving the average revisit in less than 30 minutes by deploying a constellation of 32 satellites in low orbit at an altitude of 510 km. The mission operation mode of S-STEP is divided into normal mode, observation mode, communication mode, and orbit maintenance mode. Further,, the attitude control mode is subdivides into initial detumbling, sun pointing, target pointing, ground station pointing, and thrust direction maintenance. Based on the preliminary mission operational scenario and the satellite's characteristics, this study analyzed the attitude control performance during initial detumbling and observation modes. It verifies that each mode's attitude control accuracy requirements within the time allotted by the scenario of the S-STEP achieved.

Comparison and evaluation between 3D-bolus and step-bolus, the assistive radiotherapy devices for the patients who had undergone modified radical mastectomy surgery (변형 근치적 유방절제술 시행 환자의 방사선 치료 시 3D-bolus와 step-bolus의 비교 평가)

  • Jang, Wonseok;Park, Kwangwoo;Shin, Dongbong;Kim, Jongdae;Kim, Seijoon;Ha, Jinsook;Jeon, Mijin;Cho, Yoonjin;Jung, Inho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.1
    • /
    • pp.7-16
    • /
    • 2016
  • Purpose : This study aimed to compare and evaluate between the efficiency of two respective devices, 3D-bolus and step-bolus when the devices were used for the treatment of patients whose chest walls were required to undergo the electron beam therapy after the surgical procedure of modified radical mastectomy, MRM. Materials and Methods : The treatment plan of reverse hockey stick method, using the photon beam and electron beam, had been set for six breast cancer patients and these 6 breast cancer patients were selected to be the subjects for this study. The prescribed dose of electron beam for anterior chest wall was set to be 180 cGy per treatment and both the 3D-bolus, produced using 3D printer(CubeX, 3D systems, USA) and the self-made conventional step-bolus were used respectively. The surface dose under 3D-bolus and step-bolus was measured at 5 measurement spots of iso-center, lateral, medial, superior and inferior point, using GAFCHROMIC EBT3 film (International specialty products, USA) and the measured value of dose at 5 spots was compared and analyzed. Also the respective treatment plan was devised, considering the adoption of 3D-bolus and stepbolus and the separate treatment results were compared to each other. Results : The average surface dose was 179.17 cGy when the device of 3D-bolus was adopted and 172.02 cGy when step-bolus was adopted. The average error rate against the prescribed dose of 180 cGy was -(minus) 0.47% when the device of 3D-bolus was adopted and it was -(minus) 4.43% when step-bolus was adopted. It was turned out that the maximum error rate at the point of iso-center was 2.69%, in case of 3D-bolus adoption and it was 5,54% in case of step-bolus adoption. The maximum discrepancy in terms of treatment accuracy was revealed to be about 6% when step-bolus was adopted and to be about 3% when 3D-bolus was adopted. The difference in average target dose on chest wall between 3D-bolus treatment plan and step-bolus treatment plan was shown to be insignificant as the difference was only 0.3%. However, to mention the average prescribed dose for the part of lung and heart, that of 3D-bolus was decreased by 11% for lung and by 8% for heart, compared to that of step-bolus. Conclusion : It was confirmed through this research that the dose uniformity could be improved better through the device of 3D-bolus than through the device of step-bolus, as the device of 3D-bolus, produced in consideration of the contact condition of skin surface of chest wall, could be attached to patients' skin more nicely and the thickness of chest wall can be guaranteed more accurately by the device of 3D-bolus. It is considered that 3D-bolus device can be highly appreciated clinically because 3D-bolus reduces the dose on the adjacent organs and make the normal tissues protected, while that gives no reduction of dose on chest wall.

  • PDF

An algebraic step size least mean fourth algorithm for acoustic communication channel estimation (음향 통신 채널 추정기를 이용한 대수학적 스텝크기 least mean fourth 알고리즘)

  • Lim, Jun-Seok
    • The Journal of the Acoustical Society of Korea
    • /
    • v.35 no.1
    • /
    • pp.55-62
    • /
    • 2016
  • The least-mean fourth (LMF) algorithm is well known for its fast convergence and low steady-state error especially in non-Gaussian noise environments. Recently, there has been increasing interest in the least mean square (LMS) algorithms with variable step size. It is because the variable step-size LMS algorithms have shown to outperform the conventional fixed step-size LMS in the various situations. In this paper, a variable step-size LMF algorithm is proposed, which adopts an algebraic optimal step size as a variable step size. It is expected that the proposed algorithm also outperforms the conventional fixed step-size LMF. The superiority of the proposed algorithm is confirmed by the simulations in the time invariant and time variant channels.

A Study on the Visual Elevation Image of Apartment Buildings (아파트 입면계획에서 시각적 디자인 이미지에 관한 연구)

  • 손세욱;구시온
    • Journal of the Korean housing association
    • /
    • v.10 no.2
    • /
    • pp.247-257
    • /
    • 1999
  • This study is aimed to propose the evaluation model of forecasting visual quality of apartment buildings, which would be a useful tool to make the architectural concepts corresponding to user needs. This study was carried out through the four-step experiments as follows. The first step is to take the user's visual evaluation construct. To do this, the 22 adjective phrases were extracted, which were applicable to all apartment buildings. The second step is to analyze the user's visual preference, which is measured by the user's psychological quantity on the apartment buildings by S. D.(Semantic Differential) Method. The third step is to analyzethe five psychological-factors obtained from the Factor Analysis. The perceptual images on the 41 experimental subjects were checked up through evaluating and analyzing the factor scores of each subjects for each psychological-factor. The fourth step is to analyze, the similarity of various characters in a building, which is mirrored on the user's psychological quantity and how buildings are grouped by it.

  • PDF

The Effect of Using Standing Step Condition on Biomechanical Variables during Jab in Boxing (복싱 잽(jab) 동작 시 제자리 스텝의 사용이 운동역학적 변인에 미치는 영향)

  • Lee, Seong-Yeol;Kwon, Moon-Seok
    • Journal of the Korean Applied Science and Technology
    • /
    • v.37 no.2
    • /
    • pp.232-240
    • /
    • 2020
  • The purpose of this study was to analyze the effect of using standing step condition on biomechanical variables during jab in boxing. For this purpose, eight orthodox type college boxers(age = 20.38±0.52 yrs, height = 172.38±5.80 cm, body mass = 63.45±8.56 kg, career = 6.00±1.07 yrs) who without injury to the musculoskeletal system participated in the experiment over the last year. In order to verify the effect of biomechanical variables using standing step during jab in boxing, the paired t-test (α = .05) statistical method was used. First, W.S(with-step) showed a greater impact force than N.S(non-step), and muscle activity was analyzed to be low. Second, it was analyzed that the pelvis and foot segments move faster because W.S affects the velocity of the anterior segment of the human body. Third, the rotational movement of the pelvis was faster in W.S. Fourth, W.S was analyzed to have greater ground reaction force in the anterior caused by the right and left foot than N.S. Through this, it was found that the use of the standing step during jab increases the ground reaction force the velocity and rotational movement of the human segment. Therefore, it was confirmed that it allowed a faster and more agile movement, and thus produces a greater impact force with relatively less muscle activity. Therefore, in order to effectively deliver a greater impact force to the opponent during the jab, it was effectively analyzed to accompany the standing step.