• Title/Summary/Keyword: S-300 system

Search Result 950, Processing Time 0.034 seconds

제주도 한라산 남북측 사면 용천수의 수리지구화학

  • 이광식;박원배;현승규;김용제;문덕철;김구영
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.408-412
    • /
    • 2004
  • A total of 23 springs distributed in the southern and northern sides of Mt. Hala in Jeju Island were seasonally sampled and analyzed for their major ion chemistry and oxygen and hydrogen isotope compositions to investigate their hydrogeochemical and isotopic characteristics. Dissolved ion concentrations of the south-side springs slightly increase with decreasing altitude. This indicates that dissolved ion concentrations of groundwater recharged at higher altitudes increase by water-rock interaction during the downgradient migration of groundwater through highly permeable volcanic aquifer. Dissolved ion concentrations of the north-side springs also slightly increase with decreasing altitude, but dramatically increase at ~300 m.a.s.l. This may indicate a sudden input of contaminants to the north-side groundwater system around ~300 m.a.s.l. Springs located in areas above ~300 m.a.s.l. have very low concentrations of dissolved ions, showing little seasonal variations. Whereas springs located in areas below ~300 m.a.s.l. show a big seasonal variation in the concentration of dissolved ions. Seasonal variation of oxygen isotope compositions of springs is ~3$\textperthousand$ for high-altitude springs (~1700 m.a.s.l.) and is ~2$\textperthousand$ near shore, indicating an attenuation of the variation through mixing with other groundwater bodies during migration.

  • PDF

A study on the Application of STS wire Mesh air Cleaner for the 2-Wheel Automotive (2륜 자동차 공기청정기의 STS적용에 관한 연구)

  • Yi, C.S.;Lee, Y.H.;Suh, J.S.;Chung, H.S.;Jeong, H.M.
    • Journal of Power System Engineering
    • /
    • v.6 no.4
    • /
    • pp.30-35
    • /
    • 2002
  • This study represents the effects of the material of the air cleaner on the performance in a 4-stroke spark-ignition engine for motorcycles. This study is mainly focused on the possibility of the adopting the STS wire mesh air cleaner of a S.I engine. For investigating the possibility of that, the engine power, the fuel consumption and the exhaust gas analysis were carried out for the synthetic fiber air cleaner and the different size of 200 mesh, 250 mesh, 300 mesh of STS wire mash air cleaner. As the results of this study, the performance of STS wire air cleaner was similar to the fiber air cleaner at 9000 rpm but 300 mesh of STS air cleaner had a high engine power and torque at 9500 rpm. In the case of the synthetic fiber air cleaner the concentration of CO was low at 6500 rpm and in the case of the 300 mesh in STS wire mesh air cleaner the concentration of HC was lowest at all experimental regions.

  • PDF

Construction and performance evaluation of a medium energy ion scattering spectroscopy system (중 에너지 이온산란 분광장치의 제작 및 성능 평가)

  • 김현경;문대원;김영필;이재철;강희재
    • Journal of the Korean Vacuum Society
    • /
    • v.6 no.1
    • /
    • pp.97-102
    • /
    • 1997
  • A medium energy ion scattering spectroscopy(ME1S) system has been developed and tested.In the MEIS system a toroidal electrostatic energy analyzer(TEA) and a two dimensional position sensitivedetector(PSD) were used. The energy resolution of MEIS system was estimated to be less than $4\times 10^{-3}$ and the overall angular resolution was less than 0.3". From the MEIS spectrum of $Ta_2O_5$(300 $\AA$)/ onSi analyzedousing 60 keV $H^+$, the energy loss factor(S.1 and depth resolution were estimated to he 42 eV/$\AA$ and 9.7 $\AA$, respectively. Also Si(100) surface was analyzed using the MEIS system. A random MElSspectrum was obtained from thc Si(100) covered with native oxide layers. At the double alignment condition, MElS spectrum showed ;i Si surface peak, a oxygen peak and a carbon peak.nd a carbon peak.

  • PDF

Overhead Hoist Transport Control System Design Using UML (UML을 적용한 OHT 제어 시스템 설계)

  • Sim, Gab-Sig;Jung, Tae-Young
    • The KIPS Transactions:PartD
    • /
    • v.11D no.2
    • /
    • pp.461-470
    • /
    • 2004
  • As the semiconductor industrials change 200㎜-sized semiconductor wafer production process to 300㎜-sized one, it requires to develop the software for monitoring and simulating the robot which transfers a 300㎜-sized semiconductor wafer. Because such a software don't run at standalone but communicate MCS(Material Control System) and Its subsystem a robot, its architecture is very complex. Therefore, in order to develop such a software systematically, we must utilize an object-oriented development methodology. UML. This paper presents an UML process application developing the software for monitoring and simulating the robot which transfers a semiconductor wafer on the production process.

Growth of Lettuce in Closed-Type Plant Production System as Affected by Light Intensity and Photoperiod under Influence of White LED Light (밀폐형 식물생산시스템에서 백색 LED를 이용한 광도와 광주기에 따른 상추의 생장)

  • Park, Ji Eun;Park, Yoo Gyeong;Jeong, Byoung Ryong;Hwang, Seung Jae
    • Journal of Bio-Environment Control
    • /
    • v.22 no.3
    • /
    • pp.228-233
    • /
    • 2013
  • This study was conducted to examine the effect of light intensity and photoperiod of white LEDs as the artificial light source on the growth of leaf lettuce (Lactuca sativa L.) 'Seonhong Jeokchukmyeon' in a closed-type plant production system. Seedlings, transplanted at a density of $20cm{\times}20cm$ in a completely randomized design, were grown under white LEDs (FC Poibe Co. Ltd., Korea), at one of the 3 light intensities (100, 200, or $300{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$), and each with one of 3 photoperiods [12/12, 18/6, or 24/0 (Light/Dark)]. Plants were cultured for 22 days under the condition of $21{\pm}2^{\circ}C$, $60{\pm}10%$ RH, and $400{\pm}50{\mu}mol{\cdot}mol^{-1}\;CO_2$. The greatest leaf length and width, fresh and dry weights, and total anthocyanin content were obtained in the 24/0 photoperiod, regardless of the light intensity. Length of the longest root, fresh and dry weights, and number of leaves were greater in light intensity of $200{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ than 100 or $300{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$. Chlorophyll value was the greatest in the photoperiod 12/12 than 18/6 or 24/0. The results obtained suggest that plant grew the best kept by light intensity at 200 or $300{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, and photoperiod of 12/12 or 18/6.

Development of Medical System using Time-varying Magnetic field (시변 펄스형 자기장 의료기기 시스템)

  • Kim, In-Soo S.;Hong, Jung-Hwang
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.12
    • /
    • pp.2343-2351
    • /
    • 2007
  • In this paper, we describe the design and implementation of time-varying magnetic field stimulator. Novel design for power supply part to generate high repetitive magnetic field for very short time(less than $300{\mu}s$) was achieved. Using the novel designed power supply part and the circular type coil probe, we've achieved high magnetic field up to 1.2 Tesla in 20Hz repetition rate.

A Study on Emergency Monitoring Robot System by Back-Propagation Algorithm

  • Yoo, Sowol;Kim, Miae;Lee, Kwangok;Bae, Sanghyun
    • Journal of Integrative Natural Science
    • /
    • v.7 no.1
    • /
    • pp.62-66
    • /
    • 2014
  • This study aims to implement the emergency monitoring robot system which predicts the current state of the patients without visiting the medical institutions by measuring the basic health status of the user's blood pressure, heartbeat, and basic health status of body temperature in the disaster emergency situation based on the Smart Grid. By arranging a large number of sensor(blood pressure, heartbeat, body temperature sensor) and measuring the bio signs, so the attached wireless XBee sensor can be stored in DB of robot, and it aims to draw the current state of the patients by analysis of stored bio data. Among 300 data obtained from the sensor, 1st data to 100th data were used for learning, and from 101st data to 300th data were used for assessment. 12 results were different among the total 300 assessment data, so it shows about 96% accuracy.

Separation Performance of a Low-pressure Hydrocyclone for Suspended Solids in a Recirculating Aquaculture System

  • Lee, Jin-Hwan
    • Fisheries and Aquatic Sciences
    • /
    • v.13 no.2
    • /
    • pp.150-156
    • /
    • 2010
  • The separation performance of a low-pressure hydrocyclone (LPH) was evaluated for suspended-solids removal in a recirculating aquaculture system (RAS). The dimensions of the LPH were 335 mm cylinder diameter, 575 mm cylinder height, 60 mm overflow diameter, 50 mm underflow diameter, and $68^{\circ}$ cone angle. The inflow rate varied (400, 600, 800, and 1,000 mL $s^{-1}$) with 25%, 25%, 20%, and 10% of bypass ($R_f$), respectively. The maximum total separation efficiency (Et) and reduced separation efficiency (E't) for suspended solids from the effluent of the second settlement tank (before biofiltration) were 58.9% and 45.2%, respectively, at an inflow rate of 600 mL $s^{-1}$ and 25% of $R_f$. The maximum Et and E't for suspended solids from the water supply channel (after biofiltration) were 24.4% and 16%, respectively, at an inflow rate of 1,000 mL $s^{-1}$ and 10% of $R_f$. The maximum grade efficiency (Ei) was 51.6% for a 300 ${\mu}m$ particle size at an inflow rate of 600 mL $s^{-1}$ with 23% of $R_f$. The maximum reduced grade efficiency (E'i) was 37.6% for a 300 ${\mu}m$ particle size at an inflow rate of 1,000 mL $s^{-1}$ with 11% of $R_f$. The results indicate that the separation performance of the LPH for suspended solids removal was size selective and that maximum removal occurred at particle sizes ranging from 300 to 500 ${\mu}m$.

The Analysis of Global Register Allocation Algorithms (전역 레지스터 할당 알고리즘 분석)

  • 박종득
    • Proceedings of the IEEK Conference
    • /
    • 2000.06c
    • /
    • pp.51-54
    • /
    • 2000
  • In this paper, an compiler system is ported and modified for register allocation experiments. This compiler system will enable various global register allocation. Lcc is introduced and Chaitin's graph coloring algorithm is executed with cmcc on DEC ALPHA 255/300. Several functions of SPEC921NT is used as inputs of the compiler system.

  • PDF