• Title/Summary/Keyword: S대역

Search Result 1,981, Processing Time 0.046 seconds

Video Compression using Characteristics of Wavelet Coefficients (웨이브렛 계수의 특성을 이용한 비디오 영상 압축)

  • 문종현;방만원
    • Journal of Broadcast Engineering
    • /
    • v.7 no.1
    • /
    • pp.45-54
    • /
    • 2002
  • This paper proposes a video compression algorithm using characteristics of wavelet coefficients. The proposed algorithm can provide lowed bit rate and faster running time while guaranteeing the reconstructed image qualify by the human virtual system. In this approach, each video sequence is decomposed into a pyramid structure of subimages with various resolution to use multiresolution capability of discrete wavelet transform. Then similarities between two neighboring frames are obtained from a low-frequency subband which Includes an important information of an image and motion informations are extracted from the similarity criteria. Four legion selection filters are designed according to the similarity criteria and compression processes are carried out by encoding the coefficients In preservation legions and replacement regions of high-frequency subbands. Region selection filters classify the high-frequency subbands Into preservation regions and replacement regions based on the similarity criteria and the coefficients In replacement regions are replaced by that of a reference frame or reduced to zero according to block-based similarities between a reference frame and successive frames. Encoding is carried out by quantizing and arithmetic encoding the wavelet coefficients in preservation regions and replacement regions separately. A reference frame is updated at the bottom point If the curve of similarity rates looks like concave pattern. Simulation results show that the proposed algorithm provides high compression ratio with proper Image quality. It also outperforms the previous Milton's algorithm in an Image quality, compression ratio and running time, leading to compression ratio less than 0.2bpp. PSNR of 32 dB and running tome of 10ms for a standard video image of size 352${\times}$240 pixels.

Design of a Holter Monitoring System with Flash Memory Card (플레쉬 메모리 카드를 이용한 홀터 심전계의 설계)

  • 송근국;이경중
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.3
    • /
    • pp.251-260
    • /
    • 1998
  • The Holter monitoring system is a widely used noninvasive diagnostic tool for ambulatory patient who may be at risk from latent life-threatening cardiac abnormalities. In this paper, we design a high performance intelligent holter monitoring system which is characterized by the small-sized and the low-power consumption. The system hardware consists of one-chip microcontroller(68HC11E9), ECG preprocessing circuit, and flash memory card. ECG preprocessing circuit is made of ECG preamplifier with gain of 250, 500 and 1000, the bandpass filter with bandwidth of 0.05-100Hz, the auto-balancing circuit and the saturation-calibrating circuit to eliminate baseline wandering, ECG signal sampled at 240 samples/sec is converted to the digital signal. We use a linear recursive filter and preprocessing algorithm to detect the ECG parameters which are QRS complex, and Q-R-T points, ST-level, HR, QT interval. The long-term acquired ECG signals and diagnostic parameters are compressed by the MFan(Modified Fan) and the delta modulation method. To easily interface with the PC based analyzer program which is operated in DOS and Windows, the compressed data, that are compatible to FFS(flash file system) format, are stored at the flash memory card with SBF(symmetric block format).

  • PDF

A GNSS Code Tracking Scheme Based in Slope Difference of Correlation Outputs (상관 함수의 기울기 차에 기반한 GNSS의 부호 추적 기법)

  • Yoo, Seung-Soo;Yoo, Seung-Hwan;Chong, Da-Hae;Ahn, Sang-Ho;Yoon, Seok-Ho;Kim, Sun-Yong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.6C
    • /
    • pp.505-511
    • /
    • 2008
  • The global navigation satellite system (GNSS) is using a direct sequence/spread spectrum (DS/SS) modulation. In order to recover the information data, the DS/SS system first performs a two-step synchronization process: acquisition and tracking. The acquisition process adjusts the phase difference between the received and locally generated acquisition sequences within ${\pm}T_c/2$ or less, where $T_c$ is the chip period. The tracking process performs fine synchronization. In this paper, we focus on the tracking issue. The single delta delay locked loop($\Delta$-DLL) is the optimal tracking scheme for a GNSS in the absence of multipath signals, where $\Delta$ means the spacing between the early and late correlation time offset. In the multipath environments, however, the $\Delta$-DLL suffers from huge estimation bias(denoted by $\beta$) caused by distorted correlation values. Although some modified schemes such as a $\Delta$-DLL with a narrow $\Delta$ and a double delta DLL (${\Delta}^{(2)}$-DLL) were proposed to reduce the estimation bias, they cannot remove the estimation bias completely and need more accurate acquisition process. This paper proposes a novel tracking scheme that can dramatically reduce the estimation bias, using the maximum slope change among the correlation outputs.

The Study of Thermal Effect Suppression and Wavelength Dependence of Azobenzene-coated FBG for UV Sensing Application (UV광 측정용 아조벤젠 코팅된 FBG의 열적 효과 제거 및 파장 의존성에 대한 연구)

  • Choi, Dong-Seok;Kim, Hyun-Kyoung;Ahn, Tae-Jung
    • Korean Journal of Optics and Photonics
    • /
    • v.22 no.2
    • /
    • pp.67-71
    • /
    • 2011
  • In the paper, we have demonstrated an azobenzene-coated fiber Bragg grating (FBG) for monitoring ultraviolet light (UV) intensity in remote measurement. The elasticity of the coated azobenzene polymer is changed by the UV light, which induces a center wavelength change corresponding to the change of the FBG's grating period. The wavelength shift resulting from both UV light and other light with the wavelength out of the UV range was about 0.18 nm. In order to improve the accuracy of the measurement, the center wavelength shift caused by radiant heat of the light source was sufficiently removed by using a thermal filter. The amount of the center wavelength shift was consequently reduced to 0.06 nm, compared to the result without the thermal filter. Also, the FBGs coated by using azobenzene polymer were produced by two different methods; thermal casting and UV curing. Considering temperature dependence, UV curing is more suitable than thermal casting in UV sensor application of the azobenzene-coated FBG. In addition, we have confirmed the wavelength dependence of the optical sensor by means of four different band pass filters. Thus, we found out that the center wavelength shift per unit intensity is 0.029 [arb. unit] as a maximum value at 370 nm wavelength region and that the absorption spectrum of the azobenzene polymer was very consistent with the wavelength dependence of the azobenzene-coated FBG.

The Design of Feature Selection Classifier based on Physiological Signal for Emotion Detection (감성판별을 위한 생체신호기반 특징선택 분류기 설계)

  • Lee, JeeEun;Yoo, Sun K.
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.11
    • /
    • pp.206-216
    • /
    • 2013
  • The emotion plays a critical role in human's daily life including learning, action, decision and communication. In this paper, emotion discrimination classifier is designed to reduce system complexity through reduced selection of dominant features from biosignals. The photoplethysmography(PPG), skin temperature, skin conductance, fontal and parietal electroencephalography(EEG) signals were measured during 4 types of movie watching associated with the induction of neutral, sad, fear joy emotions. The genetic algorithm with support vector machine(SVM) based fitness function was designed to determine dominant features among 24 parameters extracted from measured biosignals. It shows maximum classification accuracy of 96.4%, which is 17% higher than that of SVM alone. The minimum error features selected are the mean and NN50 of heart rate variability from PPG signal, the mean of PPG induced pulse transit time, the mean of skin resistance, and ${\delta}$ and ${\beta}$ frequency band powers of parietal EEG. The combination of parietal EEG, PPG, and skin resistance is recommendable in high accuracy instrumentation, while the combinational use of PPG and skin conductance(79% accuracy) is affordable in simplified instrumentation.

Design of Compact and Broadband Quasi-Yagi Antenna Using Balance Analysis of the Balun (발룬의 평형도 해석을 이용한 소형화된 광대역 Quasi-Yagi 안테나 설계)

  • Woo, Dong Sik;Kim, In-Bok;Kim, Young-Gon;Kim, Kang Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.1
    • /
    • pp.27-35
    • /
    • 2013
  • In this paper, a compact, broadband quasi-Yagi antenna utilizing balance analysis of the ultra-wideband microstrip-to-coplanar stripline(MS-to-CPS) balun is proposed. The antenna size was reduced by removing the reflector on bottom layer and ground plane is used as a reflector. A planar balun that transforms from microstrip(MS) to balanced coplanar stripline(CPS) is characterized in the amplitude and phase imbalances at CPS output ports are investigated and discussed. As compared with the conventional balun, the proposed MS-to-CPS balun demonstrated very wideband performance from 7 to over 20 GHz. From the simulation study, amplitude and phase imbalances are within 1 dB and ${\pm}5^{\circ}$, respectively. The implemented antenna provides very wide bandwidth from 6.9 to 15.1 GHz(74.5 %). The gain of the antenna is from 3.7 to 5.5 dBi, the front-to-back ratio is more than 10 dB, and the nominal radiation efficiency is about 94 %.

Development of Thermoluminescence and Optical Stimulated Luminescence Measurements System (열자극발광 및 광자극발광 측정장치의 개발)

  • Park, Chang-Young;Chung, Ki-Soo;Lee, Jong-Duk;Chang, In-Su;Lee, Jungil;Kim, Jang-Lyul
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.1
    • /
    • pp.46-54
    • /
    • 2015
  • The thermoluminescence (TL) and optically stimulated luminescence (OSL) are commonly used to measure and record the expose of individuals to ionization radiation. Design and performance test results of a newly developed TL and OSL measurement system are presented in this paper. For this purpose, the temperature of the TL material can be controlled precisely in the range of $1{\sim}1.5^{\circ}C$ by using high-frequency (35 kHz) heating system. This high-frequency power supply was made of transformer with ferrite core. For optical stimulation, we have completed an optimal combination of the filters with the arrangement of GG420 filter for filtering the stimulating light source and a UG11 filter at the detecting window (PMT). By using a high luminance blue LED (Luxeon V), sufficient luminous intensity could be obtained for optical stimulation. By using various control boards, the TL/OSL reader device was successfully interfaced with a personal computer. A software based on LabView program (National Instruments, Inc.) was also developed to control the TL/OSL reader system. In this study, a multi-functional TL/OSL dosimeter was developed and the performance testing of the system was carried out to confirm its reliability and reproducibility.

The variable power divider circuit to use the ring-hybrid coupler (링-하이브리드 커플러를 이용한 가변 전력 분배기 회로)

  • Park, Ung-hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.2
    • /
    • pp.253-259
    • /
    • 2016
  • This paper introduces a new variable power divider circuit with an arbitrary power division ratio ranging from $1:{\infty}$ to ${\infty}:1$. The proposed power divider circuit consists of one branch-line coupler to be a good input matching characteristic, two variable phase shifters with 90-degree phase variation to be connected two output paths of the branch-line coupler, and one ring-hybrid coupler to combine output signals of two variable phase shifter. The power division ratio between the two output ports of the proposed power divider can be easily controlled by the phase variation of the two phase shifter. The proposed power divider circuit fabricates on laminated RF-35 (h = 20 mil, er=3.5; Taconic) with a center frequency of 2 GHz. The power division ratio of the fabricated prototype varies from about 1:1000 to 5000000:1, with an input reflection characteristic(S11) of below -20 dB, an insertion loss of about -1.0 dB, and an isolation characteristic of below -17 dB between two output ports in the range 1.9-2.1 GHz.

The Design Method of GNSS Signal Using the Analysis Result of Receiver Performance (수신 성능 분석을 이용한 위성항법 신호 설계 방안)

  • Jin, Mi-Hyun;Choi, Heon-Ho;Kim, Kap-Jin;Park, Chan-Sik;Ahn, Jae-Min;Lee, Sang-Jeong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.6C
    • /
    • pp.502-511
    • /
    • 2012
  • As the importance of GNSS system increases, the necessity of independent system is increased also. When the independent GNSS system is required, GNSS signal design is necessary with requirement definition. This paper suggests the design method of GNSS signal using the analysis result of receiver performance. First, the candidates are defined based on the design elements. Then the receiver performance of the candidates is analyzed based on the performance evaluation parameters. The weights of performance evaluation parameter are defined in order to consider the receiver performance in a various aspects. Finally, the calculation of normalized performance evaluation parameters and weights are derived to obtain the compared value for signal selection. Spreading code, modulation method and carrier frequency are considered as design parameters. Also, correlation width, DLL PLL thermal noise jitter, frequency bandwidth and side lobe peak ratio are considered as performance evaluation parameters. And positioning performance, robustness to noise, bandwidth efficiency are considered as the performance aspects. This paper analyzes the performance of each candidate using software based simulator and suggest the method to compare objectively the performance of each candidates.

A Study for Co-channel Interference Cancelation Algorithm with Channel Estimation for WBAN System Application (WBAN 환경에서 채널 추정 기반의 공용 채널 간섭 제거 기술)

  • Choi, Won-Seok;Kim, Jeong-Gon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.6C
    • /
    • pp.476-482
    • /
    • 2012
  • In this paper, we analyze and compare several co-channel interference mitigation algorithms for WBAN application in 2.4 GHz ISM frequency bands. ML (Maximum Likelihood), OC (Optimal Combining) and MMSE (Minimum Mean Square Error) has been considered for the possible techniques for interference cancellation in view of the trade off between the performance and the complexity of implementation. Based on the channel model of IEEE 802.15.6 standard, simulation results show that ML and OC attains the lower BER performance than that of MMSE if we assume the perfect channel estimation. But, ML and OC have the additional requirement of implementation for his own and other users's channel estimation process, hence, besides the BER performance, the complexity of implementation and the sensitivity to channel estimation error should be considered since it requires the simple and small sized equipment for WBAN system application. In addition, the gap of detection BER performance between ML, OC and MMSE is much decreased under the imperfect channel estimation if we adopt real channel estimation process, therefore, in order to apply to WBAN system, the trade off between the BER performance and complexity of implemetation should be seriously considered to decide the best co-channel interference cancellation for WBAN system application.