• Title/Summary/Keyword: S/V ratio

Search Result 1,356, Processing Time 0.031 seconds

Conversion of Mixed Fat into Biodiesel in Plug Flow Reactor Using Alkali and Mixed Catalysts (관형반응기에서 알칼리 및 혼합촉매를 사용한 혼합지방의 바이오디젤화)

  • Hyun, Young-Jin
    • Journal of the Korean Applied Science and Technology
    • /
    • v.27 no.2
    • /
    • pp.123-128
    • /
    • 2010
  • The continuous transesterification of mixed fat was done on the plug flow reactor packed with the static mixers. The transesterification using 0.5 wt% KOH, 0.8 wt% TMAH and mixed catalyst[40 v/v% KOH(0.5 wt%)+60 v/v% TMAH(0.8 wt%)] was conducted with the changes of molar ratios, weight percentage of beef, flow rates and number of static mixer's elements at $65^{\circ}C$. The overall conversion of mixed fat at 1:8 molar ratio, 50 wt% of beef and 24 of static mixer's elements increased until 0.7mL/min of flow rate. The overall conversion of mixed fat showed 96% at those conditions. So, the optimum operating conditions on tublar reactor were 1:8 molar ratio, 50 wt% of beef, 0.7 mL/min of flow rate and 24 of static mixer' s elements.

A EMTP Simulation of High-Voltage Pulse Transformer for Pulsed Power System (펄스파워 시스템용 고전압 펄스변압기의 EMTP 시뮬레이션)

  • Kim, Min-Soo;Lee, Hyong-Gu;Ju, Heung-Jin;Ko, Kwang-Cheol;Kan, Hyong-Bu
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1984-1986
    • /
    • 2000
  • In pulsed-power techniques. Marx generator is generally used for the high-power device. but this generator has insulation and spatial problems. So we will suggest a pulse transformer that has a small size to generate the high voltage pulse instead of Marx generator. In this paper, Pulse duration is 4 [${\mu}s$] and the ratio of input and output voltage is 40[kV]/200[kV](step-up ratio=5). The output voltage and the process of pulse compression for pulse circuit are simulated by EMTP (Electro-Magnetic Transient Program). The secondary voltage of pulse transformer is about 200[kV] and pulse width is 4[t/s]. When the secondary winding of the pulse transformer is saturated. the pulse width is 1.25[${\mu}s$]. We selected dummy load 50[$\Omega$] for impedance matching. The pulse voltage of dummy load is 100[kV] and pulse width is 500[ns].

  • PDF

Effects of Cow에s Milk Addition on the Quality of Soybean Curd (우유 첨가가 두부 품질에 미치는 영향)

  • 김중만;김형태;최용배;황호선;김태영
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.22 no.4
    • /
    • pp.437-442
    • /
    • 1993
  • Soybean curds were made from the mixture of soybean milk and cow's milk (raw milk) at the ratio of 10, 20, 30, 40, 50% (v/v), and then the general composition and mineral content, pH, yield, firmness by sensory evaluation and amino acid composition were investigated. As cow's milk addition increased, total sugar crude fat, crude protein, ash content, firmness, weight and volume of the soybean curd were increased. Whereas moisture content decreased, $Ca^{++}$, $K^{+}$, and Na$^{+}$ were increased, but $Mg^{++}$ and Fe$^{++}$ decreased. In sensory evaluation, color (white), firmness, flavor, and taste were higher than those of control as cow's milk increased. By adding cow's milk at the ratio of 10, 20, 30, 40%, and 50%, sulfur containing amino acid content such as methionine and cystine were enriched 1.31, 1.58, 1.67, 1.85, and 1.95 times, respectively.

  • PDF

Fabrication and Characteristic Analysis of Single Poly-Si flash EEPROM (단일층 다결정 실리콘 Flash EEPROM 소자의 제작과 특성 분석)

  • Kwon Young-Jun;Jung Jung-Min;Park Keun-Hyung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.7
    • /
    • pp.601-604
    • /
    • 2006
  • In this paper, we propose the single poly-Si Flash EEPROM device with a new structure which does not need the high voltage switching circuits. The device was designed, fabricated and characterized. From the measurement results, it was found that the program, the erase and the read operations worked properly. The threshold voltage was 3.1 V after the program in which the control gate and the drain were biased with 12 V and 7 V for $100{\mu}S$, respectively. And it was 0.4 V after the erase in which the control gate was grounded and the drain were biased with 11 V for $200{\mu}S$. On the other hand, it was found that the program and the erase speeds were significantly dependent on the capacitive coupling ratio between the control gate and the floating gate. The larger the capacitive coupling ratio, the higher the speeds, but the target the area per cell. The optimum structure of the cell should be chosen with the consideration of the trade-offs.

Fatigue and Retention Characteristics of PLZT(10/y/z) Thin films with Various Zr/Ti Concentrations Ratio (PLZT(10/y/z) 박막에서 Zr/Ti 농도에 따른 피로와 리텐션 특성)

  • Joung Yang-Hee;Kang Seong-Jun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.3
    • /
    • pp.609-615
    • /
    • 2005
  • The effects of Zr/Ti concentration ratio in PLZT (10/y/z) thin films prepared by sol-gel method are investigated for the NVFRAM application. As Ti amount of Zr/Ti concentration ratio increases, the dielectric constants at 10 kHz decrease from 550 to 400, while the loss tangents increase from 0.028 to 0.053 and the leakage current densities at 170 kV/cm decrease from $1.64\times10^{-6}$ to $1.26\times10^{-7}\;A/cm^2$. In the results of hysteresis loops measured at $\pm170kV/cm$, the remanent polarization and the coercive field increase from 6.62 to $12.86{\mu}C/cm^2$ and from 32.15 to 56.45 kV/cm, respectively, according to the change from 40/60 to 0/100 in Zr/Ti concentration ratio. Fatigue and retention properties also improve much as the Zr/Ti concentration ratio change from 40/60 to 0/100. After applying $10^9$ square pulses with $\pm5V$, the remanent polarization of the PLZT (10/40/60) thin film decreases $50\%$ from the initial state while that of the PLZT (10/0/100) thin film decreases $28\%$. In the results of retention measurements of 10s s, the remanent polarization of the PLZT (10/0/100) thin film dec.eases only $10\%$ from the initial state, while that of the PLZT (10/40/60) thin film decreases $40\%$.

H/V Spectral-ratio Analysis of Microtremors in Jeju Island (제주도 상시미동의 H/V 스펙트럼비 분석)

  • Hong, Myung-Ho;Kim, Ki-Young
    • Geophysics and Geophysical Exploration
    • /
    • v.13 no.2
    • /
    • pp.144-152
    • /
    • 2010
  • To study the thickness variation of volcanic rocks of Jeju Island, microtremor data were recorded at eight and four sites using short-period and broadband seismometers, respectively, for 30 ~ 60 minutes with a 100 Hz sampling rate. During the daytime, these records show increased cultural noise at frequencies above 1.8 Hz. Natural noise occurs in the frequency range of 0.4 to 0.8 Hz in both daytime and nighttime data. Predominant frequencies determined by the H/V spectral-ratio method are in the range of 0.2 ~ 0.7 Hz. These frequencies decrease gradually as the central part of the Mt. Halla is approached. This may indicate that the basement is warped downward beneath the center of the island, which is consistent with previous gravimetric and magnetic models. Assuming an average shear-wave velocity of 1,800 m/s for the overburden basalts, the depths to basement are estimated to be between 640 and 2,140 m.

Effects of Ga Composition Ratio and Annealing Temperature on the Electrical Characteristics of Solution-processed IGZO Thin-film Transistors

  • Lee, Dong-Hee;Park, Sung-Min;Kim, Dae-Kuk;Lim, Yoo-Sung;Yi, Moonsuk
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.2
    • /
    • pp.163-168
    • /
    • 2014
  • Bottom gate thin-film transistors were fabricated using solution processed IGZO channel layers with various gallium composition ratios that were annealed on a hot plate. Increasing the gallium ratio from 0.1 to 0.6 induced a threshold voltage shift in the electrical characteristics, whereas the molar ratio of In:Zn was fixed to 1:1. Among the devices, the IGZO-TFTs with gallium ratios of 0.4 and 0.5 exhibited suitable switching characteristics with low off-current and low SS values. The IGZO-TFTs prepared from IGZO films with a gallium ratio of 0.4 showed a mobility, on/off current ratio, threshold voltage, and subthreshold swing value of $0.1135cm^2/V{\cdot}s$, ${\sim}10^6$, 0.8 V, and 0.69 V/dec, respectively. IGZO-TFTs annealed at $300^{\circ}C$, $350^{\circ}C$, and $400^{\circ}C$ were also fabricated. Annealing at lower temperatures induced a positive shift in the threshold voltage and produced inferior electrical properties.

Comparative study: nonsynonymous and synonymous substitution of SARS-CoV-2, SARS-CoV, and MERS-CoV genome

  • Sohpal, Vipan Kumar
    • Genomics & Informatics
    • /
    • v.19 no.2
    • /
    • pp.15.1-15.7
    • /
    • 2021
  • The direction of evolution can estimate based on the variation among nonsynonymous to synonymous substitution. The simulative study investigated the nucleotide sequence of closely related strains of respiratory syndrome viruses, codon-by-codon with maximum likelihood analysis, z selection, and the divergence time. The simulated results, dN/dS > 1 signify that an entire substitution model tends towards the hypothesis's positive evolution. The effect of transition/transversion proportion, Z-test of selection, and the evolution associated with these respiratory syndromes, are also analyzed. Z-test of selection for neutral and positive evolution indicates lower to positive values of dN-dS (0.012, 0.019) due to multiple substitutions in a short span. Modified Nei-Gojobori (P) statistical technique results also favor multiple substitutions with the transition/transversion rate from 1 to 7. The divergence time analysis also supports the result of dN/dS and imparts substantiating proof of evolution. Results conclude that a positive evolution model, higher dN-dS, and transition/transversion ratio significantly analyzes the evolution trend of severe acute respiratory syndrome coronavirus 2, severe acute respiratory syndrome coronavirus, and Middle East respiratory syndrome coronavirus.

An Experimental Study to Predict Minimum Shear Reinforcement Ratio of RC Beams with Various Shear Span-to-Depth Ratios (전단경간비가 다른 철근콘크리트 보의 최소전단철근비 예측에 관한 실험적 연구)

  • 김욱연;김상우;이정윤
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.890-895
    • /
    • 2003
  • The purpose of this experimental study is to investigate the influence of shear span-to-depth ratio on the minimum shear reinforcement ratio of reinforced concrete beams. In this study, 7 reinforced concrete beam specimens were tested. The parameters of experiment are shear span-to-depth ratio(a/d=2.0, 3.0, 4.0) and shear reinforcement ratio($p_v$=0%, 0.183%, and 0.233%). The section of all secimens was 350mm width and 450mm depth. The observed results were compared with the calculated results by the current ACI 318-02 Building Code and the proposed equation. The safety rate of the specimens, L5S2A, L5S3A, L5S4A, and L5S4P specimens were 1.80, 1.25, 1.38, and 1.56 respectively. The test results indicated that the shear behavior of reinforced concrete beams with the minimum shear reinforcement was influenced by the shear span-to-depth ratio.

  • PDF

Haploid Plant Characteristics and Screening for T.M.V. Resistance from in Vitro Anther Culture of Nicotiana tabacum L. (담배 약배양에 의한 반수체식물의 특성과 T.M.V. 저항성 검정)

  • Ahn, D.M.;Lee, S.C.;Yoon, I.B.;Heu, I.
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.22 no.1
    • /
    • pp.41-44
    • /
    • 1977
  • Production of haploids in vitro anther culture of Nicotiana tabacum L. was oriented in a large number on a chemically defined culture medium. The haploids were screened for T.M.V. resistance and the segregating ratio in F$_1$ were in good agreement with the expected ratio.

  • PDF