• 제목/요약/키워드: Roughness pattern

검색결과 202건 처리시간 0.033초

The Effect of Circle Lens and Soft Contact Lens with Identical Material in Clinical Application on the Eyes (써클 및 동일 재질 콘택트렌즈의 임상 적용시 눈에 미치는 영향)

  • Park, Sang Hee;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • 제16권2호
    • /
    • pp.147-157
    • /
    • 2011
  • Purpose: The present study was conducted to investigate the actual condition of circle lens wear and the differences caused by the pigmentation in blinking rate, non-invasive tear break-up time (NIBUT), and lens surface between circle and soft contact lens wear during clinical application. Methods: Eighty subjects were surveyed to know the actual condition of wearing circle lens. Blink rate, NIBUT of 20 subjects in twenties were measured after separately wearing soft contact lens and circle lens for 5 days. Their lens surfaces were also observed by scanning electron microscope. Results: Fifty percent of circle lens wearers answered that major reason for changing circle lens was discomfort and 67% of answerers wore circle lens more than 6 hours a day. The tendency of increased blink rates in both wearers of circle and soft contact lens at 30 minutes later when tear film stabilized and 3 hour after lens wearing was shown on the 1st, 3rd and 5th day with expanding wearing time. Especially at 3 hours after lens wearing on the 3rd and 5th day, the difference of blink rates was statistically different in circle lens wear and soft contact lens wear. The NIBUTs of soft contact lens wearers and circle lens wearers were 6.0 and 3.7 secs, respectively, at 30 min later on 1st day and were significantly different. NIBUTs of soft contact lens wearers and circle lens wearers were also statistically different 3 hrs after lens wearing on the 1st day and the similar pattern of NIBUTs was shown on the 3rd and 5th day. The roughness of both surfaces in soft contact lens and front surface in circle lens was same. However, pigmented front surface of circle lens was rougher and uneven. Conclusions: As the results, the circle lens wearers might feel discomfort in clinical application since the difference in lens surface of circle lens would change lens wettability during wearing. The difference by tinting contact lens was shown from the result, which could help better wearing circle lens.

Irradiation enduced In-plane magnetization in Fe/MgO/Fe/Co multilayers

  • Singh, Jitendra Pal;Lim, Weon Cheol;Song, Jonghan;Kim, Jaeyeoul;Asokan, K.;Chae, Keun Hwa
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 한국진공학회 2015년도 제49회 하계 정기학술대회 초록집
    • /
    • pp.188.1-188.1
    • /
    • 2015
  • For present investigation Fe/MgO/Fe/Co multilayer stack is grown on Si substrate using e-beam evaporation in ultrahigh vacuum. This stack is irradiated perpendicularly by 120 MeV $Ag^{8+}$ at different fluences ranging from $1{\times}10^{11}$ to $1{\times}10^{13}ions/cm^2$ in high vacuum using 15UD Pelletron Accelerator at Inter University Accelerator Centre, New Delhi. Magnetic measurements carried out on pre and post irradiated stacks show significant changes in the shape of perpendicular hysteresis which is relevant with previous observation of re-orientation of magnetic moment along the direction of ion trajectory. However increase in plane squareness may be due to the modification of interface structure of stacks. X-ray reflectivity measurements show onset of interface roughness and interface mixing. X-ray diffraction measurements carried out using synchrotron radiation shows amorphous nature of MgO and Co layer in the stack. Peak corresponding body centered Fe [JCPDS-06-0696] is observed in X-ray diffraction pattern of pre and post irradiated stacks. Peak broadening shows granular nature of Fe layer. Estimated crystallite size is $22{\pm}1nm$ for pre-irradiated stack. Crystallite size first increases with irradiation then decreases. Structural quality of these stacks was further studied using transmission electron microscopic measurements. Thickness from these measurements are 54, 36, 23, 58 and 3 nm respectively for MgO, Fe, MgO, Fe+Co and Au layers in the stack. These measurements envisage poor crystallinity of different layers. Interfaces are not clear which indicate mixing at interface. With increase fluence mixing and diffusion was increased in the stack. X-ray absorption spectroscopic measurements carried out on these stacks show changes of Fe valence state after irradiation along with change of O(2p)-metal (3d) hybridized state. Valence state change predicts oxide formation at interface which causes enhanced in-plane magnetization.

  • PDF

The Fabrication and Characterization of Embedded Switch Chip in Board for WiFi Application (WiFi용 스위치 칩 내장형 기판 기술에 관한 연구)

  • Park, Se-Hoon;Ryu, Jong-In;Kim, Jun-Chul;Youn, Je-Hyun;Kang, Nam-Kee;Park, Jong-Chul
    • Journal of the Microelectronics and Packaging Society
    • /
    • 제15권3호
    • /
    • pp.53-58
    • /
    • 2008
  • In this study, we fabricated embedded IC (Double Pole Double throw switch chip) polymer substrate and evaluate it for 2.4 GHz WiFi application. The switch chips were laminated using FR4 and ABF(Ajinomoto build up film) as dielectric layer. The embedded DPDT chip substrate were interconnected by laser via and Cu pattern plating process. DSC(Differenntial Scanning Calorimetry) analysis and SEM image was employed to calculate the amount of curing and examine surface roughness for optimization of chip embedding process. ABF showed maximum peel strength with Cu layer when the procuring was $80\sim90%$ completed and DPDT chip was laminated in a polymer substrate without void. An embedded chip substrate and wire-bonded chip on substrate were designed and fabricated. The characteristics of two modules were measured by s-parameters (S11; return loss and S21; insertion loss). Insertion loss is less than 0.55 dB in two presented embedded chip board and wire-bonded chip board. Return loss of an embedded chip board is better than 25 dB up to 6 GHz frequency range, whereas return loss of wire-bonding chip board is worse than 20 dB above 2.4 GHz frequency.

  • PDF

ZnO 나노 입자가 분산 된 Resin을 이용한 굴절률 조절 및 광 산란 패턴 형성을 통한 비정질 실리콘 박막태양전지의 효율 향상

  • Ko, Bit-Na;Kim, Jae-Hyeon;Kim, Gyu-Tae;Sin, Ju-Hyeon;Jeong, Pil-Hun;Chu, So-Yeong;Choe, Hak-Jong;Hyeon, Seok;Lee, Heon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.295-295
    • /
    • 2014
  • 일반적으로 박막 태양전지의 효율은 박막 종류에 따른 광 흡수율에 의해 결정되며, 이는 증착한 박막의 두께에 의해 결정된다. 증착한 박막의 두께가 두꺼워질수록 광 흡수율은 증가하지만, 박막 두께가 지나치게 두꺼워지면 열화 현상으로 인한 모듈의 효율 감소가 생기므로 적절한 박막의 두께가 요구된다. 특히 a-Si:H의 경우 가시광 영역에서 높은 흡수계수를 가지고 있어서 얇은 박막 두께로도 태양전지의 제작이 가능하지만, 동일한 박막 두께에서 효율을 더욱 향상시키기 위한 다양한 광 포획 기술에 대한 연구가 많이 진행 되고 있다. 본 연구에서는 자외선을 이용한 nano-imprint lithography 기술을 이용하여 a-Si:H 태양전지의 유리기판 위에 pattern을 삽입하여 광 산란 효과를 향상 시키고자 하였다. 또한 유리기판의 굴절률 (n=1.5)과 투명전극의 굴절률 (n=1.9)의 중간 값을 갖는 ZnO nanoparticles (n=1.7)이 분산 된 imprinting resin을 사용함으로써 점진적으로 굴절률을 변화시켜, 최종적으로 a-Si:H 층까지의 광 투과율을 높이고자 하였다. 제작한 기판의 종류는 다음과 같다. 첫 번째 기판으로는 유리기판 위에 ZnO nanoparticles이 분산 된 imprinting resin을 spin-coating 하여 점진적인 굴절률의 변화에 의한 투과도 향상을 확인하고자 하였다. 두 번째 기판으로는 규칙적인 배열을 갖는 micro 크기의 패턴을 형성하였다. 마지막으로는 불규칙한 배열을 갖는 nano 크기와 micro 크기가 혼재 된 패턴을 형성하여 투과도 향상과 동시에 빛의 산란을 증가시키고자 하였다. 후에 이 세가지 종류를 기판으로 사용하여 a-Si:H 기반의 박막 태양전지를 제작하였다. 먼저 제작한 박막 태양전지용 기판의 광학적 전기적 특성을 분석하였다. 유리 기판 위에 형성한 패턴에 의한 roughness 변화를 확인하기 위해 atomic force microscopy (AFM)를 이용하여 시편의 표면을 측정하였다. 또한 제작한 유리 기판 위에 투명 전극층을 형성 후, 이로 인한 전기적 특성의 변화를 확인하기 위해 hall measurement system을 이용하여 sheet resistance, carrier mobility, carrier concentration 등의 특성을 측정하였다. 또한, UV-visible photospectrometer 장비를 이용하여 각 공정마다 시편의 광학적 특성(투과도, 반사도, 산란도, 흡수도 등)을 측정하였고, 최종적으로 제작한 박막 태양전지의 I-V 특성과 외부양자효율을 측정하여 태양전지의 효율 변화를 확인하였다. 그 결과 일반적인 유리에 기판에 제작된 a-Si:H 기반의 박막 태양전지에 비해, ZnO nanoparticles이 분산 된 imprinting resin을 spin-coating 하여 점진적인 굴절률 변화를 준 것만으로도 약 12%의 태양전지 효율이 증가하였다. 또한, micro 크기의 패턴과 nano-micro 크기가 혼재된 패턴을 형성한 경우 일반적인 유리를 사용한 경우에 비해 각각 27%, 36%까지 효율이 증가함을 확인하였다.

  • PDF

The effect of PDGF-BB loaded TCP/chitosan microgranules on new bone formation (혈소판유래성장인자를 함유한 TCP-chitosan 미세과립이 신생골조직 형성에 미치는 영향에 관한 연구)

  • Seol, Yang-Jo;Lee, Jue-Yeon;Kye, Seung-Beom;Lee, Young-Kyu;Kim, Won-Kyeong;Lee, Yong-Moo;Ku, Young;Han, Soo-Boo;Lee, Seung-Jin;Chung, Chong-Pyoung;Rhyu, In-Chul
    • Journal of Periodontal and Implant Science
    • /
    • 제32권3호
    • /
    • pp.489-500
    • /
    • 2002
  • The purpose of this study was to evaluate newly fabricated tricalcium phosphate(TCP)/chitosan microgranuls as bone substitutes. TCP/chitosan microgranules were fabricated by dropping TCP-chitosan suspension into the NaOH/ethanol solution. The size of microgranules could be controllable via airflow rate. PDGF-BB was loaded into the fabricated granules via freeze-drying methods(300 ng/20 mg). To evaluate cell proliferation, cultured osteoblasts cell lines(MC3T3-El) was dropped on the BioOss(R), chitosan microgranules, TCP/chitosan microgranules and cultured for 1, 7 , 14, and 28 days. Scanning electron microscopic observation was done after 7 days of culture and light microscopic examination was done after 28 days of culture. PDGF-BB release from the microgranules was tested. Rabbit calvarial defects(8 mm in diameter) were formed and chitosan, TCP/chitosan, PDGF-TCP/chitosan microgranules, and BioGran(R) were grafted to test the ability of new bone formation. At SEM view, the size of prepared microgranules was 250-1000 um and TCP powders were observed at the surface of TCP/chitosan microgranules. TCP powders gave roughness to the granules and this might help the attachment of osteoblasts. The pores formed between microgranules might be able to allow new bone ingrowth and vascularization. There were no significant differences in cell number among BioOss(R) and two microgranules at 28 day. Light and scanning electron microscopic examination showed that seeded osteoblastic cells were well attached to TCP/chitosan microgranules and proliferated in a multi-layer. PDGF-BB released from TCP/chitosan microgranules was at therapeutic concentration for at least 1 week. In rabbit calvarial defect models, PDGF-TCP/chitosan microgranules grafted sites showed thicker bone trabeculae pattern and faster bone maturation than others. These results suggested that the TCP/chitosan microgranules showed the potential as bone substitutes.

Microgrooves on titanium surface affect peri-implant cell adhesion and soft tissue sealing; an in vitro and in vivo study

  • Lee, Hyo-Jung;Lee, Jaden;Lee, Jung-Tae;Hong, Ji-Soo;Lim, Bum-Soon;Park, Hee-Jung;Kim, Young-Kwang;Kim, Tae-Il
    • Journal of Periodontal and Implant Science
    • /
    • 제45권3호
    • /
    • pp.120-126
    • /
    • 2015
  • Purpose: With the significance of stable adhesion of alveolar bone and peri-implant soft tissue on the surface of titanium for successful dental implantation procedure, the purpose of this study was to apply microgrooves on the titanium surface and investigate their effects on peri-implant cells and tissues. Methods: Three types of commercially pure titanium discs were prepared; machined-surface discs (A), sandblasted, large-grit, acid-etched (SLA)-treated discs (B), SLA and microgroove-formed discs (C). After surface topography of the discs was examined by confocal laser scanning electron microscopy, water contact angle and surface energy were measured. Human gingival fibroblasts (hGFs) and murine osteoblastic cells (MC3T3-E1) were seeded onto the titanium discs for immunofluorescence assay of adhesion proteins. Commercially pure titanium implants with microgrooves on the coronal microthreads design were inserted into the edentulous mandible of beagle dogs. After 2 weeks and 6 weeks of implant insertion, the animal subjects were euthanized to confirm peri-implant tissue healing pattern in histologic specimens. Results: Group C presented the lowest water contact angle ($62.89{\pm}5.66{\theta}$), highest surface energy ($45{\pm}1.2mN/m$), and highest surface roughness ($Ra=22.351{\pm}2.766{\mu}m$). The expression of adhesion molecules of hGFs and MC3T30E1 cells was prominent in group C. Titanium implants with microgrooves on the coronal portion showed firm adhesion to peri-implant soft tissue. Conclusions: Microgrooves on the titanium surface promoted the adhesion of gingival fibroblasts and osteoblastic cells, as well as favorable peri-implant soft tissue sealing.

Polymer Optical Microring Resonator Using Nanoimprint Technique (나노 임프린트 기술을 이용한 폴리머 링 광공진기)

  • Kim, Do-Hwan;Im, Jung-Gyu;Lee, Sang-Shin;Ahn, Seh-Won;Lee, Ki-Dong
    • Korean Journal of Optics and Photonics
    • /
    • 제16권4호
    • /
    • pp.384-391
    • /
    • 2005
  • A polymer optical microring resonator, which is laterally coupled to a straight bus waveguide, has been proposed and demonstrated using a nanoimprint technique. The propagation loss of the ring waveguide and the optical power coupling between the ring and bus waveguides was calculated by using a beam propagation method, then the dependence of the device performance on them was investigated using a transfer matrix method. We have especially introduced an imprint stamp incorporating a smoothing buffer layer made of a silicon nitride thin film. This layer played an efficient role in improving the sidewall roughness of the waveguide pattern engraved on the stamp and thus reducing the scattering loss. As a result the overall Q factor of the resonator was greatly increased. Also it reduced the gap between the ring and bus waveguides effectively to enhance the coupling between them, without relying on the direct writing method based on an e-beam writer. As for the achieved device performance at the wavelength of 1550 nm, the quality factor, the extinction ratio, and the free spectral range were ~103800, ~11 dB, and 1.16 m, respectively.

Photoemission Electron Micro-spectroscopic Study of the Conductive Layer of a CVD Diamond (001)$2{\times}1$ Surface

  • Kono, S.;Saitou, T.;Kawata, H.;Goto, T.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 한국진공학회 2009년도 제38회 동계학술대회 초록집
    • /
    • pp.7-8
    • /
    • 2010
  • The surface conductive layer (SCL) of chemical vapor deposition (CVD) diamonds has attracting much interest. However, neither photoemission electron microscopic (PEEM) nor micro-spectroscopic (PEEMS) information is available so far. Since SCL retains in an ultra-high vacuum (UHV) condition, PEEM or PEEMS study will give an insight of SCL, which is the subject of the present study. The sample was made on a Ib-type HTHP diamond (001) substrate by non-doping CVD growthin a DC-plasma deposition chamber. The SCL properties of the sample in air were; a few tens K/Sq. in sheet resistance, ${\sim}180\;cm^2/vs$ in Hall mobility, ${\sim}2{\times}10^{12}/cm^2$ in carrier concentration. The root-square-mean surface roughness (Rq) of the sample was ~0.2nm as checked by AFM. A $2{\times}1$ LEED pattern and a sheet resistance of several hundreds K/Sq. in UHV were checked in a UHV chamber with an in-situ resist-meter [1]. The sample was then installed in a commercial PEEM/S apparatus (Omicron FOCUS IS-PEEM) which was composed of electro-static-lens optics together with an electron energy-analyzer. The presence of SCL was regularly monitored by measuring resistance between two electrodes (colloidal graphite) pasted on the two ends of sample surface. Figure 1 shows two PEEM images of a same area of the sample; a) is excited with a Hg-lamp and b) with a Xe-lamp. The maximum photon energy of the Hg-lamp is ~4.9 eV which is smaller that the band gap energy ($E_G=5.5\;eV$) of diamond and the maximum photon energy of the Xe-lamp is ~6.2 eV which is larger than $E_G$. The image that appear with the Hg-lamp can be due to photo-excitation to unoccupied states of the hydrogen-terminated negative electron affinity (NEA) diamond surface [2]. Secondary electron energy distribution of the white background of Figs.1a) and b) indeed shows that the whole surface is NEA except a large black dot on the upper center. However, Figs.1a) and 1b) show several features that are qualitatively different from each other. Some of the differences are the followings: the two main dark lines A and B in Fig.1b) are not at all obvious and the white lines B and C in Fig.1b) appear to be dark lines in Fig.1a). A PEEMS analysis of secondary electron energy distribution showed that all of the features A-D have negative electron affinity with marginal differences among them. These differences can be attributed to differences in the details of energy band bending underneath the surface present in SCL [3].

  • PDF

Dry Etching of Flexible Polycarbonate and PMMA in O2/SF6/CH4 Discharges (O2/SF6/CH4 플라즈마를 이용한 플렉시블 Polycarbonate와 PMMA의 건식 식각)

  • Joo, Y.W.;Park, Y.H.;Noh, H.S.;Kim, J.K.;Lee, J.W.
    • Journal of the Korean Vacuum Society
    • /
    • 제18권2호
    • /
    • pp.85-91
    • /
    • 2009
  • There has been a rapid progress for flexible polymer-based MEMS(Microelectromechanical Systems) technology. Polycarbonate (PC) and Poly Methyl Methacrylate (PMMA), so-called acrylic, have many advantages for optical, non-toxic and micro-device application. We studied dry etching of PC and PMMA as a function of % gas ratio in the $O_2/SF_6/CH_4$ temary plasma. A photoresist pattern was defined on the polymer samples with a mask using a conventional lithography. Plasma etching was done at 100 W RIE chuck power and 10 sccm total gas flow rate. The etch rates of PMMA were typically 2 times higher than those of PC in the whole experimental range. The result would be related to higher melting point of PC compared to that of PMMA. The highest etch rates of PMMA and PC were found in the $O_2/SF_6$ discharges among $O_2/SF_6$, $O_2/CH_4$ and $SF_6/CH_4$ and $O_2/SF_6/CH_4$ plasma composition (PC: ${\sim}350\;nm/min$ at 5 sccm $O_2/5$ sccm $SF_6$, PMMA: ${\sim}570\;nm/min$ at 2.5 sccm $O_2/7.5$ sccm $SF_6$). PC has smoother surface morphology than PMMA after etching in the $O_2/SF_6/CH_4$ discharges. The surface roughness of PC was in the range of 1.9$\sim$3.88 nm. However, that of PMMA was 17.3$\sim$26.1 nm.

THE EFFECTS OF SURFACE TREATMENT OF DENIAL NICKEL-CHROMIUM ALLOY ON TENSILE BOND STRENGTH (치과용 니켈-크롬합금에 대한 표면 처리가 인장접착강도에 미치는 영향)

  • Lee, Eun-Suk;Kwon, Oh-Won
    • The korean journal of orthodontics
    • /
    • 제27권3호
    • /
    • pp.493-502
    • /
    • 1997
  • This study was conducted to evaluate the tensile bond strength by bonding the dental bracket with Super-bond after treating the surface of dental Nickel-Chromium alloy with sandblasting, sandblasting & tin-plating, respectively, and tin-plating. 10 pieces of Nickel-Chromium alloys with brackets bonded with Super-bond without their surface treatment were sampled as a control group, 20 pieces of Nickel-Chromium alloy brackets bonded with Super-bond after treating them with sandblasting as group I, 20 pieces of Nickel-Chromium alloys tin-plated and bonded with Super-bond after sandblasting as group II, and then 20 pieces of alloys with brackets bonded with Super-bond after tin-plating as group III. The result of those examination and comparison is summarized as follows: 1. Group I showed the mean tensile bond strength of $14.41{\pm}2.24MPa$ which was highest among 4 groups, followed by group III($13.59{\pm}.51MPa$), group II($12.27{\pm}.45MPa$), and control group($10.50{\pm}1.57MPa$), respectively. However, it was shown that there was no statistically significant difference between group I and III, group III and II, and group II and control group(p>0.05). 2. The main failure pattern of those brackets showed that $70\%$ of the control group had an adhesive failure at the bracket-Superbond interface, and $30\%$ at the Nickel-Chromium alloy-Superbond interface, while other groups did the adhesive failure at the bracket-Superbond interface. 3. When examined under SEM, it was shown that adhesives were mostly attached to the surface of the Nickel-Chromium alloy for all groups while a considerable quantity of adhesives were attached to the bracket base. Then, those samples treated only with sandblasting showed the most even and remarkable roughness of their surface.

  • PDF