• Title/Summary/Keyword: Rotational Motion

Search Result 606, Processing Time 0.029 seconds

Molecular Dynamics Simulation Study on Segmental Motion in Liquid Normal Heptadecane

  • 이송희;김한수;박형석
    • Bulletin of the Korean Chemical Society
    • /
    • v.19 no.11
    • /
    • pp.1217-1221
    • /
    • 1998
  • We present results of molecular dynamic (MD) simulations for the segmental motion of liquid n-heptadecane in order to investigate conformational transitions from one rotational isomeric state to another. The behavior of the hazard plots for n-heptadecane obtained from our MD simulations are compared with that for polymer of Brownian dynamics (BD) study. The transition rate at the ending dihedrals of the n-heptadecane chain is much higher than that at the central dihedrals. In the study of correlation between transitions of neighboring dihedrals, the large value of c2 implies that some 30% of the transitions of the second neighbors can be regarded as following transitions two bonds away in a correlated fashion. Finally the analysis of multiple transitions and the number of times occurred in the initial 0.005 ns are discussed.

EQUATIONS OF MOTION FOR CRACKED BEAMS AND SHALLOW ARCHES

  • Gutman, Semion;Ha, Junhong;Shon, Sudeok
    • Nonlinear Functional Analysis and Applications
    • /
    • v.27 no.2
    • /
    • pp.405-432
    • /
    • 2022
  • Cracks in beams and shallow arches are modeled by massless rotational springs. First, we introduce a specially designed linear operator that "absorbs" the boundary conditions at the cracks. Then the equations of motion are derived from the first principles using the Extended Hamilton's Principle, accounting for non-conservative forces. The variational formulation of the equations is stated in terms of the subdifferentials of the bending and axial potential energies. The equations are given in their abstract (weak), as well as in classical forms.

Effect of Kinematic Motion on Changes in Coefficients of Friction of Porcine Knee Joint Cartilage (기구학적 운동이 돼지 무릎 관절연골의 마찰계수 변화에 미치는 영향)

  • Kim, Hwan;Kim, ChoongYeon;Lee, KwonYong;Kim, DaeJoon;Kim, DoHyung
    • Tribology and Lubricants
    • /
    • v.29 no.1
    • /
    • pp.46-50
    • /
    • 2013
  • In this study, the frictional behaviors of articular cartilage against a Co-Cr alloy in two types of kinematic motions were compared. Cartilage pins were punched from the femoral condyles of porcine knee joints, and Co-Cr alloy disks were machined from orthopedic-grade rods and polished to a surface roughness ($R_a$) of 0.002. Friction tests were conducted by using a pin-on-disk-type tribotester in phosphate buffered saline (PBS) under pressures of 0.5, 1, and 2 MPa. All tests were performed in the repeat pass rotational (ROT) and the linear reciprocal (RCP) sliding motions with the same sliding distance and speed of 50 mm/s. The coefficients of friction of the cartilage against the Co-Cr alloy increased with the sliding time in both kinematic motions for all contact pressures. The maximum coefficients of friction in RCP motion were 1.08, 2.82, and 1.96 times those in ROT motion for contact pressures of 0.5, 1, and 2 MPa, respectively. As the contact pressure increased, the coefficients of friction gradually increased in RCP motion, whereas they decrease and then increased in ROT motion. The interaction between the directional change of the shear stress and the orientation of collagen fiber in the superficial layer of the cartilage could affect the change in the frictional behaviors of the cartilage. A large difference in the coefficients of friction between the two kinematic motions could be interpreted as differences in the directional change of shear stress at the contact surface.

MPM-Based Angular Animation of Particles using Polar Decomposition Theory (극 분해 이론을 활용한 MPM기반의 입자 회전 애니메이션)

  • Song, Chang-yong;Kim, Ki-hoon;Kim, Sun-jeong;Kim, Changhun
    • Journal of the Korea Computer Graphics Society
    • /
    • v.28 no.4
    • /
    • pp.13-22
    • /
    • 2022
  • In this paper, we propose a single framework based on the MPM(Material Point Method) that can represent the dynamic angular motion of the elementary particle unit. In this study, the particles can have various shapes while also describing linear and angular motion. As a result, unlike other particle-based simulations, which only represent linear movements of spherical (e.g. Circle, Sphere) particles, it is possible to express the visually dynamic motion of them. The proposed framework utilizes MPM, due to the fact that rotational motion can be decomposed and derived from large deformation. During the integration process of the presented technique, a deformation gradient tensor is decomposed by polar decomposition theory for extracting rotation tensor. By applying this together with the linear motion of each particle, as a result, it is possible to simultaneously express the angluar and linear motion of the particle itself. To verify the proposed method, we show the simulation of rotating particles scattering in the wind field, and the interaction(e.g. Collision) between a moving object and them by comparing the traditional MPM

Study of Blood Characteristics in Stenosed Artery under Human Body Rotation by Using FSI Method (FSI 기법을 적용한 인체 회전 시 협착 혈관에서의 혈류 특성)

  • Cho, Seong Wook;Kim, Seungwook;Ro, Kyoung Chul;Ryou, Hong Sun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.5
    • /
    • pp.449-457
    • /
    • 2013
  • In this study, we performed a numerical analysis to investigate the effect of rotation on the blood flow and arterial wall behavior by using the FSI (fluid-structure interaction) technique. The geometry of the artery included 50% stenosis at the center. To simulate the rotational effect, 2-6 rps of axial velocity was applied to the arterial model. A spiral wave and asymmetric flow occurred due to the stenosis and axial rotation both in the rigid body model and in the FSI model. However, the arterial wall motion caused periodic and transient blood flow changes in the FSI model. The FRZ (fluid recirculation zone) decreased in the FSI model, which is a known predictor for the formation and vulnerability of plaque. Therefore, it is observed that arterial wall motion also influences the generation of the FRZ.

Effect of Neutron irradiation in $Fe_{81}B_{13.5}_Si{3.5}C_2$Amorphous Ribbon (비정질 $Fe_{81}B_{13.5}_Si{3.5}C_2$ 리본의 중성자 조사에 따른 자기적 특성변화)

  • 김효철;홍권표;김철기;유성초
    • Journal of the Korean Magnetics Society
    • /
    • v.10 no.2
    • /
    • pp.49-52
    • /
    • 2000
  • The changes of magnetic properties in neutron irradiated F $e_{81}$ $B_{13.5}$S $i_{3.5}$ $C_2$ amorphous ribbon were studied by X-ray diffraction, hysteresis loop, temperature dependence of magnetization and complex permeability. The fluences of thermal ( $n_{th}$) and fast ( $n_{f}$) neutron were 6.95$\times$10$^{18}$ $n_{th}$ c $m^{-2}$ and 4.56$\times$10$^{16}$ $n_{f}$c $m^{-2}$ , respectively. The changes of XRD Profiles were not observable at the neutron irradiated sample. The complex permeability spectra showed that the permeability from domain wall motion decreased due to the increase of pinning force against domain motion by the neutron irradiation, and the relaxation frequency of rotational magnetization moved to higher frequency region. The measurement of hysteresis loop showed the increase of magnetic softness, related to rotational magnetization, but saturation magnetization was decreased in neutron irradiation sample. The Curie temperature was decreased in the neutron irradiated sample.e.e.e.

  • PDF

Particle filter for Correction of GPS location data of a mobile robot (이동로봇의 GPS위치 정보 보정을 위한 파티클 필터 방법)

  • Noh, Sung-Woo;Kim, Tae-Gyun;Ko, Nak-Yong;Bae, Young-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.2
    • /
    • pp.381-389
    • /
    • 2012
  • This paper proposes a method which corrects location data of GPS for navigation of outdoor mobile robot. The method uses a Bayesian filter approach called the particle filter(PF). The method iterates two procedures: prediction and correction. The prediction procedure calculates robot location based on translational and rotational velocity data given by the robot command. It incorporates uncertainty into the predicted robot location by adding uncertainty to translational and rotational velocity command. Using the sensor characteristics of the GPS, the belief that a particle assumes true location of the robot is calculated. The resampling from the particles based on the belief constitutes the correction procedure. Since usual GPS data includes abrupt and random noise, the robot motion command based on the GPS data suffers from sudden and unexpected change, resulting in jerky robot motion. The PF reduces corruption on the GPS data and prevents unexpected location error. The proposed method is used for navigation of a mobile robot in the 2011 Robot Outdoor Navigation Competition, which was held at Gwangju on the 16-th August 2011. The method restricted the robot location error below 0.5m along the navigation of 300m length.

A comparative analysis of the kinematical characteristics of Forehand & Backhand Flying Disc Throwing (플라잉디스크 포핸드 및 백핸드 던지기 동작의 운동학적 특성 비교)

  • Kim, Mee-Hyang;Park, Jong-Chul;Byun, Kyung-Seok
    • Journal of Digital Convergence
    • /
    • v.17 no.12
    • /
    • pp.555-563
    • /
    • 2019
  • This study was to provide quantitative basic data on the forehand and backhand throw movements of flying disks. For this purpose, the kinematic variables were calculated using the three-dimensional motion analysis system. A comprehensive analysis of the study variables showed that it is important to throw flying disks accurately as well as far away, so in P2 and P3 it is necessary to control forward movement and concentrate on the rotation of the joints. In addition, rotational force transfer from pelvis to body is considered important for efficient rotational movement. The forehand was found to mainly utilize the movement of the upper extremity joint to perform throwing motion, while the backhand throw was found to be relatively utilized for the rotation of the torso and pelvis. Based on the quantitative data of this study, we hope that it can be used as a basic material for on-site training of Flying Discs.

Bending Vibration of Rotating Cantilever Beams (회전 외팔보의 굽힘 진동해석)

  • 유홍희
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.5
    • /
    • pp.891-898
    • /
    • 1992
  • When catilever beams rotate about axes perpendicular to the underformed beam's longitudinal axis, their bending stiffnesses change due to the stretching caused by centrifugal inertia forces. Such phenomena result in variations of natural frequencies and mode shapes associated with constant speed rotational motions of the beams. These variations are important in many practical applications such as helicopter blades, turbomachines, and space structures. This paper presents the formulation of a set of linear equations governing the lateral motion of rotating cantilever beams. These equations can be used to provide accurate predictions of the variations of natural frequencies and mode shapes associated with constant speed rotational motions of the beams. These variations are important in many practical applications such as helicopter blades, turbomachines, and space structures. This paper presents the formulation of a set of linear equations governing the lateral motion of rotating cantilever beams. These equations can be used to provide accurate predictions of the variations of natural frequencies and mode shapes due to rotation. This technique is simpler and more consistent than other conventional techniques which are commonly used in the literature.

A Kinematic analysis of Golf Swing Motion (골프 스윙동작의 운동학적 분석)

  • Shin, Sung-Hyu;Ko, Seok-Kon
    • Korean Journal of Applied Biomechanics
    • /
    • v.13 no.2
    • /
    • pp.101-114
    • /
    • 2003
  • The purpose of this study was to examine the major kinematicak variance to Increase the club head velocity during the driver swing two PGA prp-golfers utilizing 3-dimensional Image analyzing linear velocity of the club-head during the impact quantiatively. To achive these purpose, two high speed camera in 120 field/s and one high-speed camera in 500 field/s were used in this study. The program made by Younghoo Kwon(1944) was used to analysis the digitalization of reference point, digitalization of joint venter, synchronization, calculation of 3-Dimensional coordinate by DLT method, and smoothing. Through this study, the conclusions are as follow. 1. During the drivel swing, in the percentile of the total time, two pro-golfer showed 0.925, 0.929 second from adress to top-swing, 0.236, 0.929 second from top-swing to impact. 2. During the driver swing, in the displacement of the center of the body, two pro-golfer showed 45.3, 45.23% from adress, 44.3, 44.24% front impact. 3. In the velocity variance, The maximum club-head velocity two pro-golfer showed 43.36, 43.24m/s respectively the down swing. The ball velocity showed 63.12, 63.06m/s. 4. In the rotational angle of the shoulder joint. two pro-golfer showed $-13.5,-13.53^{\circ}$, during the back swing respectively. Two subject adressed opening status og upper body. 5. In the rotational angle of the right knee angle showed $156.3,154.7^{\circ}$ from the adress.