• Title/Summary/Keyword: Rotation error

Search Result 461, Processing Time 0.021 seconds

A Vector-Coordinate-Rotation Arithmetic Processor Using RNS (RNS를 이용한 벡터 좌표 회전 연산 프로세서)

  • Cho, Won Kyung;Lim, In Chil
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.23 no.3
    • /
    • pp.340-344
    • /
    • 1986
  • This paper shows that we can design a vector-coordinate rotation processor and obtain the approximate evaluations of sine and cosine based upon the use of residue number systems. The algorithm results in the considerable improvement of the computation speed when compared to CORDIC algorithm. The results from computer simulation show that the mean error of sine and cosine is 0.0025 and the mean error of coordinate rotation arithmatic is 0.65. Also, the proposed processor has the efficiency for the design and fabrication of integrated circuit, because it consists of the array of idecntially structured look-up tables.

  • PDF

Nozzle Swing Angle Measurement Involving Weighted Uncertainty of Feature Points Based on Rotation Parameters

  • Liang Wei;Ju Huo;Chen Cai
    • Current Optics and Photonics
    • /
    • v.8 no.3
    • /
    • pp.300-306
    • /
    • 2024
  • To solve the nozzle swing angle non-contact measurement problem, we present a nozzle pose estimation algorithm involving weighted measurement uncertainty based on rotation parameters. Firstly, the instantaneous axis of the rocket nozzle is constructed and used to model the pivot point and the nozzle coordinate system. Then, the rotation matrix and translation vector are parameterized by Cayley-Gibbs-Rodriguez parameters, and the novel object space collinearity error equation involving weighted measurement uncertainty of feature points is constructed. The nozzle pose is obtained at this step by the Gröbner basis method. Finally, the swing angle is calculated based on the conversion relationship between the nozzle static coordinate system and the nozzle dynamic coordinate system. Experimental results prove the high accuracy and robustness of the proposed method. In the space of 1.5 m × 1.5 m × 1.5 m, the maximum angle error of nozzle swing is 0.103°.

Comparison Between Stroke Patients and Normal Persons for Trunk Position Sense and It's Relation to Balance and Gait (정상인과 뇌졸중 환자의 체간 위치감각 비교 및 보행과 균형에 미치는 영향)

  • Yang, Hea-Duck;Kim, Chang-beom;Choi, Jong-Duk;Moon, Young
    • Physical Therapy Korea
    • /
    • v.27 no.3
    • /
    • pp.178-184
    • /
    • 2020
  • Background: Stroke patients have reduced trunk control compared to normal people. The ability to control the trunk of a stroke patient is important for gait and balance. However, there is still a lack of research methods for the characteristics of stroke control in stroke patients. Objects: The aim of this research was to determine whether trunk position sense has any relation with balance and gait. Methods: This study assessed trunk performance by measuring position sense. Trunk position sense was assessed using the David back concept to determine trunk repositioning error in 20 stroke patients and 20 healthy subjects. Four trunk movements (flexion, extension, lateral flexion, rotation) were tested for repositioning error and the measurement was carried out 6 times per move; these parameters were used to compare the mean values obtained. Subjects with stroke were also evaluated with clinical measures of balance and gait. Results: There were significant differences in trunk repositioning error between the stroke group and the control group in flexion, lateral flexion to the affected side, lateral flexion to the unaffected side, rotation to the affected side, and rotation to the unaffected side. Mean flexion error: post-stroke: 7.95 ± 6.76 degrees, control: 3.32 ± 2.27; mean lateral flexion error to the affected side: 6.13 ± 3.79, to the unaffected side: 5.32 ± 3.15, control: 3.57 ± 1.92; mean rotation error to the affected side: 8.25 ± 3.09, to the unaffected side: 9.24 ± 3.94, control: 5.41 ± 1.82. There was an only significant negative correlation between the repositioning error of lateral flexion and the Berg balance scale score to the affected side (-0.483) and to the unaffected side (-0.497). A strong correlation between balance and gait was found. Conclusion: The results of this study indicate that stroke patients exhibit greater trunk repositioning error than age-matched controls on all planes of movement except for extension. And lateral flexion has correlation with balance and gait.

Study of the CatcherTM Couch's Usefulness (토모치료기 CatcherTM Couch의 유용성에 대한 고찰)

  • Um, Ki Cheon;Lee, Chung Hwan;Jeon, Soo Dong;Song, Heung Kwon;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.2
    • /
    • pp.65-74
    • /
    • 2019
  • Purpose: Recently, A Catcher was added to prevent sagging in Radixact® X9. In this study, We quantitatively compared general couch of Tomo-HDA® with catcher couch of Radixact® X9 using the human phantom and evaluated usefulness of catcher. Materials and methods: We used rando phantom for phantom study and set the each iso-center of head and neck region and Pelvis region for region parameter. Furthermore, We used hand made low melting point alloys for weight parameter. MVCT(Mega Voltage Computed Tomography) images were acquired for vertical error and rotation(pitch) error measurement increasing weight(A: 15kg, A+B: 30kg, A+B+C: 45kg). We selected 120 patients who has been treated using Tomotherpy machine for patient study. 60 patients has been treated in Tomo-HDA® and the other 60 patients treated in Radixact® X9. In the patient study methods, vertical error and rotation(pitch) error was measured for mean value calculation using MVCT images acquired on first day of radiation therapy. Result: Result of phantom study, Vertical error and rotation(pitch) error was increased proportionally increased as the weight increases in general couch of Tomo-HDA®. each maximum value was 7.52mm, 0.38° in head and neck region and 11.94mm, 0.92° in pelvis region. However, We could confirm that there was stable error range(0.02~0.1mm, 0~0.04°) in Catcher couch of Radixact®. Result of patient study, The head and neck region was measured 4.79mm 0.33° lower, and the pelvis region was measured 7.66mm, 0.22° lower in Catcher couch of Radixact® X9. Conclusion: In this study, Vertical error and rotation(pitch) error was proportionally increased as the weight increases in general couch of Tomo-HDA®. Especially, The pelvis region error was more increased than the head and neck region error. However, Vertical error and rotation(pitch) error was regularly generated regardless of weight or regions in CatcherTM couch of Radixact® X9 that this study's purpose. In conclusion, CatcherTM couch of Radixact® X9 can minimize mechanical error that couch sagging. Furthermore, The pelvis region is more efficiency than head and neck region. In radiation therapy using Tomotherapy machine, it is regarded that may contribute to minimizing unadjusted pitch error due to characters of Tomotherapy.

A Study on Tooth Micro-geometry Optimization of Planetary Gear for 5MW Wind Turbine Pitch Drive (5MW 풍력용 피치드라이브의 유성기어 Micro-geometry 최적화에 관한 연구)

  • Lee, In-Bum;Kim, Dong-Young;Xu, Zhe-Zhu;Lee, Do-Young;Lyu, Sung-Ki
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.1
    • /
    • pp.85-91
    • /
    • 2014
  • The rotation of a spindle unit must be accurate for high-quality machining and to improve the quality of the machine tools. Therefore, the proper measurement of the rotation accuracy and ensuring a proper analysis are very important. Separate processes are necessary because spindle errors and roundness errors associated with the test balls can both factor into the measured rotation error values. We used three methods to discern test ball errors and analyzed which could be deemed as the most proper technique in a test of the rotation accuracy of the main spindle of a machine tool.

A Method of Pose Matching Rate Acquisition Using The Angle of Rotation of Joint (관절의 회전각을 이용한 자세 매칭률 획득 방법)

  • Hyeon, Hun-Beom;Song, Su-Ho;Lee, Hyun
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.11 no.3
    • /
    • pp.183-191
    • /
    • 2016
  • Recently, in rehabilitation treatment, the situation that requires a measure of the accuracy of the pose and movement of joints is being increased due to the habits and lifestyle of modern people and the environment. In particular, there is a need for active automated system that can determine itself for the matching rate of pose Basically, a method for measuring the matching rate of pose is used by extracting an image using the Kinect or extracting a silhouette using the imaging device. However, in the case of extracting a silhouette, it is difficult to set the comparison, and in the case of using the Kinect sensor, there is a disadvantages that high accumulated error rate according to movement. Therefore, In this paper, we propose a method to reduce the accumulated error of matching rate of pose getting the rotation angle of joint by measuring the real-time amount of change of 9-axis sensor. In particular, it can be measured same conditions that unrelated of the physical condition and unaffected by the data for the back and forth movement, because of it compares the current rotation angle of the joint. Finally, we show a comparative advantage results by compared with traditional method of extracting a silhouette and a method using a Kinect sensor.

Improvement of Chip Thickness Model in 2-flutes Slot End Milling (2날 엔드밀 슬롯 가공시 칩두께 모델의 개선)

  • Lee Dong-Kyu;Lee Ki-Yong;Lee Kune-Woo;Oh Won-Zin;Kim Jeong-Suk
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.1
    • /
    • pp.32-38
    • /
    • 2005
  • Generally, cutting force models use a sin function method to calculate chip thickness. In slot end milling, the error from a sin function method is much bigger than other machining because a tool rotation angle in cutting is much larger. Thus in this paper, a new method to calculate chip thickness was suggested and evaluated. In a new method, tool position data according to tool rotation are checked and stored so that it is possible correct chip thickness is calculated. Cutting force waveforms simulated from a sin function method and a new method and measured waveforms from experiments were compared and error percentages were obtained. Finally, a new method had good results for simulating cutting force in slot end milling.

Measurement of Radial Error Motions of a Rotating Spindle by Moire Topography (모아레 원리를 이용한 스핀들의 반경방향 회전정도 측정)

  • 박윤창;김승우
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.11
    • /
    • pp.2723-2729
    • /
    • 1993
  • Moire principles are applied to the measurement of the spindle radial error motion. As opposed to conventional techniques, no master cylinder or ball is needed in the measurement so that the offset and out-of-roundness errors of the master can be inherently eliminated. Two periodic circular gratings are used, one is made on the spindle and the other is held stationary on the reference frame. When the two gratings are seen superimposed during spindle rotation, an interference fringe pattern is observed from which the information on the eccentricity between the two gratings can be extracted with high precision. The optical design and fringe analysis techniques of a prototype measurement system are described in detail with exemplary measurement results.

Registration Error Compensation for Face Recognition Using Eigenface (Eigenface를 이용한 얼굴인식에서의 영상등록 오차 보정)

  • Moon Ji-Hye;Lee Byung-Uk
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.5C
    • /
    • pp.364-370
    • /
    • 2005
  • The first step of face recognition is to align an input face picture with database images. We propose a new algorithm of removing registration error in eigenspace. Our algorithm can correct for translation, rotation and scale changes. Linear matrix modeling of registration error enables us to compensate for subpixel errors in eigenspace. After calculating derivative of a weighting vector in eigenspace we can obtain the amount of translation or rotation without time consuming search. We verify that the correction enhances the recognition rate dramatically.

Noncommutativity Error Analysis with RLG-based INS (링레이저 자이로 관성항법시스템의 비교환 오차 해석)

  • Kim, Gwang-Jin;Park, Chan-Guk;Yu, Myeong-Jong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.1
    • /
    • pp.81-88
    • /
    • 2006
  • In this paper, we analyze a noncommutativity error that is not able to be compensated with integrating gyro outputs in RLG-based INS. The system can suffer from some motion known as RLG dithering motion, coning motion, ISA motion derived by an AV mount and vehicle real dynamic motion. So these motions are a cause of the noncommutativity error, the system error derived by each motion has to be analyzed. For the analysis, a relation between rotation vector and gyro outputs is introduced and applied to define the coordinate transformation matrix and the angular vector.