• 제목/요약/키워드: Root canal types

검색결과 50건 처리시간 0.019초

단근 소구치의 근관계 형태에 따른 치근단 부위의 근관 형태 (The apical root canal shape according to the root canal system of premolars with single root)

  • 박민수;황호길;조형훈
    • 대한치과의사협회지
    • /
    • 제55권1호
    • /
    • pp.63-70
    • /
    • 2017
  • Materials and methods: Sixty extracted premolars were assigned to three groups according to the root canal system (Weine's classification; type I, II and III) of 20 teeth each using radiographic examination. The root tip was cut horizontally 1 mm from the anatomical apex and the apical cross-section was visualized using microscope at x50 magnification and photographed. Minimum and maximum apical root canal diameter of each tooth was measured and classified into three types by canal morphology (round, oval and flattened shape). Statistical analysis was performed to compare the apical root canal diameter and morphology according to the root canal system. Results: In apical root canal morphology at cross-sectional view, the most common shape was round in type I, flat in type II, and oval in type III. In apical root canal diameters at cross-sectional view, there was a significant difference between the minimum and maximum diameter in all types (p<0.05). The maximum diameter was 0.331 mm in type I, 0.519 mm in type II, and 0.310 mm in type III. There was a significant difference among type I, III and type II (p<0.05). Conclusion: The morphology and diameter of apical root canal was different according to the root canal system. Therefore, clinicians should consider the apical file size in view of the apical root canal shape according to the root canal system.

  • PDF

단근 소구치의 근관계에 관한 방사선 사진과 투명표본 간의 일치도 (COINCIDENCE BETWEEN RADIOGRAPHS AND CLEARING SAMPLES ON THE ROOT CANAL SYSTEMS OF SINGLE HOOTED PREMOLARS)

  • 황호길;강호민;서강
    • Restorative Dentistry and Endodontics
    • /
    • 제30권6호
    • /
    • pp.461-469
    • /
    • 2005
  • 한 개의 치근을 가진 상, 하악 소구치의 방사선 사진 상의 근관계와 동일치아의 투명표본 상의 근관계를 각각 관찰한 다음 상호 비교하기 위해 총 142개의 소구치를 선택한 후, 구내 치과용 표준 방사선 필름을 이용하여 근원심과 협설측으로 방사선을 채득하였다. 동일하게 교육받은 4명의 판독자가 방사전 사진을 판독하여 근관계의 형태를 분류하였다. 동일한 치아에 근판와동을 형성한 후 $5\%$ 질산용액에 48시간 동안 담가 치수조직을 용해시키고 인디안 잉크를 치수강 내로 주입하여 치수조직을 염색하였다. $5\%$ 질산용액에 48시간 동안 담가 탈회시킨 후 메틸 살리실레이트로 투명화시키고 입체현미경하에서 20배의 크기로 근관계의 형태를 평가하여 다음과 같은 결과를 얻었다. 방사선과 입체현미경 소견간에는 판독자 간에 통계학적으로 유의한 차이를 나타냈다 (p<0.05). 따라서 동일한 방사선 사진을 판독할 경우 판독자 간에 근관의 형태에 있어서 차이가 있을 수 있다. 그러므로 임상가는 방사전 사진을 주의깊은 판독과 예견된 근관의 형태에 따라 난이도를 고려하여 근관치료를 시행해야 할 것으로 사료된다.

콘빔CT (Cone beam computed tomography, CBCT)를 이용한 상악 대구치 에서의 C-형 치근 및 근관에 관한 연구 (A cone-beam computed tomographic study of C-shaped root and root canal in maxillary molars)

  • 김진우;지효진;조경모;김성민;박세희
    • 구강회복응용과학지
    • /
    • 제31권2호
    • /
    • pp.104-111
    • /
    • 2015
  • 목적: 이 후향적 연구의 목적은 한국인에서 콘빔CT를 이용하여 상악 대구치에서 C-형 치근 및 근관의 발현빈도와 형태를 분류하기 위함이다. 연구 재료 및 방법: 총 357개 상악 대구치(제1대구치 186개, 제2대구치 171개)의 콘빔CT 영상을 두 명의 치과보존과 전문의가 평가하였다. 결과: 8가지의 C-형 치근 형태와 5가지의 C-형 근관형태로 분류할 수 있었으며, C-형 치근 및 근관의 발현빈도는 각각 21.0%와 5.3%였다. 결론: 이러한 해부학적 변이는 제1대구치보다 제2대구치에서 많이 발견되었다. 상악 대구치의 성공적인 근관치료를 위해 다양한 형태의 C-형 치근 및 C-형 근관에 대한 해부학적 지식이 필요하다.

Evaluation of mesial root canal configuration of mandibular first molars using micro-computed tomography

  • Salli, Gulay Altan;Egil, Edibe
    • Imaging Science in Dentistry
    • /
    • 제51권4호
    • /
    • pp.383-388
    • /
    • 2021
  • Purpose: The aim of this study was to evaluate the root canal morphology of mesial roots of mandibular first molars. Materials and Methods: Forty extracted mandibular first molars were used in this study. The morphological examination of root canals was conducted in accordance with the Vertucci classification using micro-computed tomography (micro-CT). Any aberrant root canal configurations not included in the Vertucci classification were recorded, and their frequency was established using descriptive statistics. Intra-observer reliability was assessed using the Wilcoxon signed-rank test, while inter-observer reliability was assessed using the Cohen kappa test. Significance was evaluated at the P<0.05 level. Results: The mesial roots of mandibular first molars had canal configurations of type I (15%), type II (7.5%), type III (25%), type IV (10%), type V (2.5%), type VI (7.5%), and type VII (7.5%). The images showed 10 (25%) additional configuration types that were not included in the Vertucci classification. These types were 1-3-2-3, 1-2-3-2-3, 2-3-1, 2-3, 1-2-3-1, 2-1-2-3, 3-2-1, 1-2-3-1, 2-3-2-3, and 1-2-1-2-1. The intra-observer differences were not statistically significant(P>0.05) and the kappa value for inter-observer agreement was found to be 0.957. Conclusion: Frequent variations were detected in mesial roots of mandibular first molars. Clinicians should take into consideration the complex structure of the root canal morphology before commencing root canal treatment procedures to prevent iatrogenic complications. Micro-CT was a highly suitable method to provide accurate 3-dimensional visualizations of root canal morphology.

근관형성 기구 및 방법에 따른 근관 형태의 변화 (CHANGES IN ROOT CANAL CONFIGURATION USING DIFFERENT FILE TYPES AND TECHNIQUES)

  • 허영주;김성교
    • Restorative Dentistry and Endodontics
    • /
    • 제22권1호
    • /
    • pp.291-304
    • /
    • 1997
  • The purposes of this study were to evaluate the changes in root canal configuration with canal instrumentation using different file types and techniques and to investigate most appropriate instrumentation technique in maintaining the original canal configuration with different file types. Fifty curved mesiobuccal or distobuccal canals of extracted human maxillary molar teeth were instrumented using a step-back technique with stainless steel K-files or nickel-titanium K-files, a crown-down pressureless technique with stainless steel K-files or nickel-titanium K-files and nickel-titanium engine-driven files. Radiographs were taken before and after instrumentation using a specially designed device that allowed for the pre-and postinstrumentation canals to be taken with the same X-ray angulation. Magnified X-ray images on a magnifier screen were traced and post instrumentation canal images were compared with the preinstrumentation ones. Changes in canal curvature and the incidence of procedural accidents were analyzed. The results were as follows : Crown-down pressureless technique with nickel-titanium K-files and nickel-titanium engine-driven filing produced no significant changes in canal curvature (p>0.05), while the step-back technique with stainless steel K-files or nickel-titanium K-files (p<0.01) and the crown-down pressureless technique with stainless steel K-files (p<0.05) produced significant changes. With nickel-titanium K-file, crown-down pressureless technique produced significantly less changes in canal curvature than step-back technique (p<0.05), while there was no significant difference between techniques with stainless steel K-files (p>0.05). File types exerted no significant influences in the changes of canal curvature both in the step-back technique and crown-down pressureless technique (0>0.05). Regardless of the file types used, step-back technique produced more procedural accidents such as ledge or elbow formation, apical zipping and apical transportation than the crowndown pressureless technique and nickel-titanium engine-driven filing. Both with stainless steel K-files and with nickel-titanium K-files, the incidence of apical extrusion of canal debris was higher in step-back technique than in crown-down pressureless technique.

  • PDF

Analysis of C-shaped root canal configuration in maxillary molars in a Korean population using cone-beam computed tomography

  • Jo, Hyoung-Hoon;Min, Jeong-Bum;Hwang, Ho-Keel
    • Restorative Dentistry and Endodontics
    • /
    • 제41권1호
    • /
    • pp.55-62
    • /
    • 2016
  • Objectives: The purpose of this study was to investigate the incidence of root fusion and C-shaped root canals in maxillary molars, and to classify the types of C-shaped canal by analyzing cone-beam computed tomography (CBCT) in a Korean population. Materials and Methods: Digitized CBCT images from 911 subjects were obtained in Chosun University Dental Hospital between February 2010 and July 2012 for orthodontic treatment. Among them, a total of selected 3,553 data of maxillary molars were analyzed retrospectively. Tomography sections in the axial, coronal, and sagittal planes were displayed by PiViewstar and Rapidia MPR software (Infinitt Co.). The incidence and types of root fusion and C-shaped root canals were evaluated and the incidence between the first and the second molar was compared using Chi-square test. Results: Root fusion was present in 3.2% of the first molars and 19.5% of the second molars, and fusion of mesiobuccal and palatal root was dominant. C-shaped root canals were present in 0.8% of the first molars and 2.7% of the second molars. The frequency of root fusion and C-shaped canal was significantly higher in the second molar than the first molar (p < 0.001). Conclusions: In a Korean population, maxillary molars showed total 11.3% of root fusion and 1.8% of C-shaped root canals. Furthermore, root fusion and C-shaped root canals were seen more frequently in the maxillary second molars.

CBCT를 이용한 한국인 고령환자의 상악 대구치에서 치근 및 근관형태의 분석 (Evaluation of root and root canal morphology of elderly Korean patients maxillary molars using cone-beam computed tomography)

  • 이태용;김미연;김선호;김정희
    • 대한치과보철학회지
    • /
    • 제58권2호
    • /
    • pp.95-102
    • /
    • 2020
  • 목적: Cone-beam computed tomographic (CBCT)를 이용하여 한국인의 상악 제1대구치(MM1), 제2대구치(MM2)에서 제2근심협측(MB2) 근관, 치근 융합 및 C형 근관의 발생률에 대해 평가하였다. 재료 및 방법: 술 전 평가를 위해 CBCT 촬영을 한 환자를 선택했다. 1658명의 환자로부터 1498개의 MM1과 1742개의 MM2의 CBCT 영상이 획득되었고, MB2 근관, 치근융합 및 C형 근관을 분석했다. 연령, 성별 및 치아위치와 MB2 근관 발생률간의 관계도 조사하였다. 결과: 연구표본은 비교적 고령(평균연령: 66.1세)이었다. MB2 근관의 발생률은 MM1, MM2 각각 60.1%, 28.0% 였고, MM1, MM2에서 각각 Weine Type III, Type II가 우세했다. 연령이 증가함에 따라 MB2 근관은 감소하는 경향을 보였으며, MM1에서는 남성에서 MB2 근관이 더 많이 발견되었다. 치근융합은 MM1에서 2.3%, MM2에서 26.2%, C형 근관은 MM1에서 0.4%, MM2에서 2.7%로 모두 MM2에서 발생률이 더 높았다. 결론: MB2 근관은 MM2보다 MM1에서 더 발생률이 높았다. 치근융합과 C형 근관은 모두 MM2에서 더 발생률이 높았다.

하악 제3대구치와 하악관과의 위치관계에 대한 파노라마 방사선사진과 cone beam형 전산화단층촬영상의 비교 (Comparison of cone beam computed tomography and conventional panoramic radiography in assessing the topographic relationship between the mandibular canal and impacted third molars)

  • 최형수;김규태;최용석;황의환
    • Imaging Science in Dentistry
    • /
    • 제38권3호
    • /
    • pp.169-176
    • /
    • 2008
  • Purpose : To assess the diagnostic accuracy and value in an imaging technique field through the comparison of cone beam computed tomography and conventional panoramic radiography in assessing the topographic relationship between the mandibular canal and impacted third molars. Materials and Methods : Participants consisted of 100 patients offered the images through cone beam computed tomography and panoramic radiography. PSR-$9000^{TM}$ Dental CT system (Asahi Roentgen Ind. Co., Ltd, Japan) was used as the unit of cone beam computed tomography. CE-II (Asahi Roentgen Ind. Co., Ltd, Japan) and Pro Max (Planmeca Oy, Finland) were used as the unit of panoramic radiography. The images obtained through panoramic radiography were classified into 3 types according to the distance between mandibular canal and root of mandibular third molar. And they were classified into 4 types according to the proximity of radiographic feature. The images obtained through cone beam computed tomography based on the classification above were classified into 4 types according to the location between the mandibular canal and the root and were analyzed. And they were classified into buccal, inferior, lingual, and between roots, according to the location between mandibular canal and root. The data were statistically analyzed and estimated by $X^2$-test. Results : 1. There was no statistical significance according to 3 types (type I, type II, type III) through CBCT. 2. The results of 4 types (type A, type B, type C, type D) through CBCT were as high prevalence of CBCT 1 in type A, CBCT 2 in type B, CBCT 3 in type C, and CBCT1 in type D and those of which showed statistical significance (P value=0.03). 3. The results according to location between mandibular canal and root through CBCT recorded each 49, 25, 17, 9 as buccal, inferior, lingual, between roots. Conclusion : When estimating the mandibular canal and the roots through the panoramic radiography, it could be difficult to drive the views of which this estimation was considerable. Thus it is required to have an accurate diagnostic approaching through CBCT that could estimate the location between mandibular canal and roots.

  • PDF

Accuracy of Root ZX in teeth with simulated root perforation in the presence of gel or liquid type endodontic irrigant

  • Shin, Hyeong-Soon;Yang, Won-Kyung;Kim, Mi-Ri;Ko, Hyun-Jung;Cho, Kyung-Mo;Park, Se-Hee;Kim, Jin-Woo
    • Restorative Dentistry and Endodontics
    • /
    • 제37권3호
    • /
    • pp.149-154
    • /
    • 2012
  • Objectives: To evaluate the accuracy of the Root ZX in teeth with simulated root perforation in the presence of gel or liquid type endodontic irrigants, such as saline, 5.25% sodium hypochlorite (NaOCl), 2% chlorhexidine liquid, 2% chlorhexidine gel, and RC-Prep, and also to determine the electrical conductivities of these endodontic irrigants. Materials and Methods: A root perforation was simulated on twenty freshly extracted teeth by means of a small perforation made on the proximal surface of the root at 4 mm from the anatomic apex. Root ZX was used to locate root perforation and measure the electronic working lengths. The results obtained were compared with the actual working length (AWL) and the actual location of perforations (AP), allowing tolerances of 0.5 or 1.0 mm. Measurements within these limits were considered as acceptable. Chi-square test or the Fisher's exact test was used to evaluate significance. Electrical conductivities of each irrigant were also measured with an electrical conductivity tester. Results: The accuracies of the Root ZX in perforated teeth were significantly different between liquid types (saline, NaOCl) and gel types (chlorhexidine gel, RC-Prep). The accuracies of electronic working lengths in perforated teeth were higher in gel types than in liquid types. The accuracy in locating root perforation was higher in liquid types than gel types. 5.25% NaOCl had the highest electrical conductivity, whereas 2% chlorhexidine gel and RC-Prep gel had the lowest electrical conductivities among the five irrigants. Conclusions: Different canal irrigants with different electrical conductivities may affect the accuracy of the Root ZX in perforated teeth.

역행충전시 수복재와 와동 형태에 따른 변연누출의 정량적 분석 (QUANTITATIVE ANALYSIS OF MARGINAL MICROLEAKAGE IN VARIOUS RETROGRADE FILLING MATERIALS AND PREPARATION TYPES)

  • 한충경;양홍서
    • Restorative Dentistry and Endodontics
    • /
    • 제15권1호
    • /
    • pp.97-105
    • /
    • 1990
  • When conventional root canal treatment is failed or contraindicated, retrograde root canal filling following apicoectomy is a valuable procedure, aimed at hermetically sealing the root canal against leakage of irritants from the canal into the periapical tissue. In this in vitro investigation, to analyze apical microleakage electrochemically in teeth with different retrograde filling materials and preparation types, single - rooted tooth was cut 2mm from the apex and each Class I and Slot preparation was prepared. Experimental groups : Group 1. Amalgam filling with cavity varnish in Class I preparation Group 2. Scotchbond 2+Silux filling in Class I preparation Group 3. Gutta percha filling with ZOE cement in Class I preparation Group 4. Amalgam filling with cavity varnish in Slot preparation Group 5. Scotchbond 2+Silux filling in Slot preparation Each specimens was immersed in 1% solution of KCl, and applied a potential of 9V external power supply. Measurements of the current flow were obtained at 1, 2, 3, 7, 9, 12, 14, 18, 21, 25 and 28 day after immerson. Marginal microleakage were compared and evaluated. The results were as follows ; 1. The group filled with composite resin with dentin bonding agent shows lower apical microleakage value than the group filled with amalgam following varnish application (P<0.01). 2. In the group filled with gutta percha, apical microleakage value was the hightest 3. There was no significant difference between Class I cavity and Slot type cavity regardless of the used materials.

  • PDF