• Title/Summary/Keyword: Room temperatures

Search Result 1,012, Processing Time 0.032 seconds

Growth of MnS Thin Film on c-Sapphire by Pulsed Laser Deposition (PLD 법에 의한 c-사파이어 기판위의 MnS 박막성장)

  • Song, Jeong-Hwan
    • Korean Journal of Materials Research
    • /
    • v.17 no.9
    • /
    • pp.475-479
    • /
    • 2007
  • Pulsed laser deposition was utilized to grow MnS thin films on c-sapphire substrate using a KrF excimer laser at growth temperatures that ranged from room temperature to $700^{\circ}C$. The results of X-ray diffraction (XRD) and UV-visible spectroscopy were employed to investigate the structural and optical properties of the MnS films. While the growth rate decreased as $T_s$ increased, the overall quality of the film improved. The highest quality MnS film was obtained at $700^{\circ}C$. Variations in the $T_s$ resulted in the MnS films exhibiting different growth mechanisms. The oriented (200) rocksalt MnS film was grown at room temperature. In the case of higher $T_s,\;200{\sim}500^{\circ}C$, the films consisted of mixed phases of rocksalt and wurtzite. The main structure of the films was altered to (111) rocksalt when the temperature was increased to in excess of $600^{\circ}C$. This behavior may very well be the result of elements such as surface energy and atomic arrangement during the growth process. The optical band gap of the obtained ${\alpha}-MnS$ film was estimated to be 3.32 eV.

A Study on the Temperature Characteristics of the Floor Cooling System of Mock-up Experimentent (Mock-up실험에 의한 바닥복사 냉방시스템의 온도특성에 관한 연구)

  • Yoo, Ho-Chun;Lee, Young-A
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.6
    • /
    • pp.48-57
    • /
    • 2008
  • The research analyzed the distribution of the indoor temperatures of a radiant floor cooling system through mock-up experiments. It investigated the temperature difference of feed water, the vertical temperature difference of indoor air, the temperature difference of floor surface, and so on. The following is the results of the research. First, the research shows that the difference between indoor temperature and outside temperature was the smallest when the temperature of feed water was set at 16$^{\circ}C$. In addition, the temperature changes according to indoor positions (wall, room, floor, and ceiling) were the most uniform. Thus, the research found that the cold water temperature of 16$^{\circ}C$ is the most proper. In addition, it confirmed that the feed water temperature of 18$^{\circ}C$ is effective because the temperature can lower the temperature of a room to 13.55$^{\circ}C$, which is lower than the temperature of a non-cooling mode. Second, an investigation on the temperature distribution of vertical air in indoor space shows that the temperature distribution had a difference of 0.2 to 1.9$^{\circ}C$ on the average, which satisfies the range of 3.0$^{\circ}C$ in the standard of ISO.

Studies on the viability and infectivity of Fasciola hepatica metacercariae (간질(Fasciola hepatica) 피낭유충의 생존성 및 감염성에 관한 연구)

  • Kim, Ji-ho;Kim, Jong-taek;Cho, Shin-hyeong;Lee, Chung-gil
    • Korean Journal of Veterinary Research
    • /
    • v.38 no.1
    • /
    • pp.161-166
    • /
    • 1998
  • Fasciola hepatica eggs were obtained from the bile of infected cattle at a local abattoir. Metacercariae(MC) were produced using Lymnaea viridis, the intermediate host of the parasite. They were stored in distilled water at refrigerator($3{\sim}5^{\circ}C$) and at room temperature($22{\sim}27^{\circ}C$). The viability and infectivity of the MC were determined at monthly intervals for 12 months. The viability was determined by both microscope and excystation, and the infectivity by infecting mice. The MC stored at room temperature had a high viability up until 60 days, and thereafter the viability declined rapidly ; at day 120, only 2.5% of the MC were excysted. Most of the MC stored at refrigerator retained the viability up until 90 days, and thereafter the viability declined slowly ; about half of them were viable at day 210 and 5% of them retained the viability until day 270. The survival rates of the MC determined by microscope were always higher than those determined by excystation(p<0.05). The infectivity of the MC wisely followed the viability at the two different storage temperatures. Most of the mice infected orally with the MC died within 3-9 weeks of acute fasciolosis.

  • PDF

The Structure and Electrochromic Characteristics of $WO_3$ thin Film with deposition Conditions and Post-Annealing (증착조건 및 후-열처리에 따른 $WO_3$박막의 구조와 전기착색 특성)

  • 조형호;임원택;안일신;이창효
    • Journal of the Korean Vacuum Society
    • /
    • v.8 no.2
    • /
    • pp.141-147
    • /
    • 1999
  • The electrochromic characteristics of tungsten oxide films are largely affected by deposition conditions, such as substrate temperature and gas flow rate and also post-annealing. We have considered gas flow rate and temperature as important factors having an effect on an electrical, optical phenomenon and structural variation of $WO_3$ . The tungsten oxide films were deposited onto ITO(20$\Omega\box$, 1000$\AA$) using rf magnetron sputtering method. In particular, the films deposited at room temperature were annealed at various temperatures in air. All specimens had crystal structure except one being deposited at room temperature with nearly amorphous-like structure. The specimen deposited at $100^{\circ}C$ had a structure in which the increase in deposition temperature. The specimen deposited at $100^{\circ}C$ had a structure in which the cations$(Li^+)$ are easily movable because of void boundaries induced by regularly arrayed large grains. The specimen deposited at $300^{\circ}C$ had a dense structure with small grains but it exhibited the large mobility and charge density in $WO_3$ because of distinct grain boundaries.

  • PDF

Structural and Magnetic Properties of LaFeO3-BaTiO3 Solid Solutions

  • Ramana, E.Venkata;Kwon, O-Ung;Kim, Jin-I;Jung, C.U.
    • Journal of Magnetics
    • /
    • v.14 no.3
    • /
    • pp.117-119
    • /
    • 2009
  • Polycrystalline samples of LaFe$O_3$-BaTi$O_3$ were synthesized to examine the structural and magnetic behavior. X-ray diffraction confirmed that the ceramics had tetragonal symmetry with less tetragonal strain (c/a) than BaTi$O_3$. The magnetic hysteresis measured at room temperature suggested that the magnetic nature deviates from that of the parent LaFe$O_3$, which has antiferromagentic with a G-type spin structure. Improved magnetic behavior of the solid solution compound might be due to the increase in the canting angle of the spin. The presence of oxygen vacancies and fluctuating Fe valence, arising from the substitution of $Ba^{2+}$ and $Ti^{4+}$ at the A- and B-sites of the lattice, might contribute to bulk magnetization. The temperature dependent magnetization indicated that magnetization was higher at low temperatures and showed a decreasing trend with increasing temperature to room temperature. The magnetic transition temperature of these samples was 665 K and 743 K for the mixed system and LaFe$O_3$, respectively.

Prediction of Useful Life by Heat Aging of Motor Fan Isolating Rubber (모터팬 방진고무부품의 노화수명 예측)

  • Kim, W.S.;Woo, C.S.;Cho, S.J.;Kim, W.D.
    • Elastomers and Composites
    • /
    • v.37 no.2
    • /
    • pp.107-114
    • /
    • 2002
  • This paper discusses the accelerated heat aging tests were carried out to predict the useful life of EPDM isolating rubber components of ventilation fan motor for clean room. 20% compression set results changes as the threshold are used for assessment of the useful life and the time to threshold value were plotted against reciprocal of absolute temperature to give the Arrhenius plot. The useful life at variable temperatures and activation energy are obtained from the Arrhenius relationship. An accelerated test program to assess useful life can be represented an appreciable investment in time was designed. We also considered the effect of antioxidant agents.

A Study on the Fatigue and Data Retention Characteristics of Single Grained PZT Thin Films (단결정립 PZT 박막의 피로 및 정보 유지 특성에 관한 연구)

  • Lee, Jang-Sik;Ju, Seung-Gi
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.5
    • /
    • pp.1-8
    • /
    • 2000
  • Fatigue and data retention characteristics of the Pt/PZT/Pt structure using single grain PZT thin films by PZT seeding method were investigated. In case of fatigue, there is no loss in switched polarization up to 2$\times$10$^{11}$ cycles using 1MHz square wave form at $\pm$10V and no data loss after 30000sec of memory retention at room temperature. From the activation energy measured at high temperatures, the time required 20% loss in remanent polarization is estimated to be 6.6$\times$10$^{7}$ years at room temperature.

  • PDF

Characteristics of Refractive Index Profiles at Different Temperatures in $LiNbO_3$ and $KTiOPO_4$ Waveguide Formed by 350 keV Light Ions

  • Wang, Ke-Ming;Feng Chen;Hui Hu;Xia, Hui-Hao;Wang, Xue-Lin;Shi, Bo-Rong;Lu, Qing-Ming
    • Journal of the Korean Vacuum Society
    • /
    • v.12 no.S1
    • /
    • pp.28-32
    • /
    • 2003
  • Both $LiNbO_3$ and $KTiOPO_4$ samples were implanted with 350 keY $H^+$ and $He^+$ ions at different doses ranging from $1 ${\times}$\times10^{16}$ to of $5 ${\times}$\times10^{16}$ ions/$\textrm{cm}^2$. Single and multi-energy implantations were performed at room temperature. Mono-mode or a few modes in both $LiNbO_3$ and $KTiOPO_4$ waveguides were observed. The effect of temperature on the refractive index profiles of $LiNbO_3$ and $KTiOPO_4$ waveguids was studied. The temperature covered from room temperature, $200^{\circ}C$, 194.5 K (dry ice) and 77K (liquid nitrogen). Different mechanisms are needed to interpret the observed behavior. A n, increased mono-mode $LiNbO_3$ waveguide was formed by multi-energy keV $He^+$ ions.

Dependence of Crosslinking Temperature on Swelling Behavior of Hyaluronic Acid Porous Microbeads Synthesized by a Modified Spray Method (노즐 낙하법으로 제조한 히알루론산 다공성 마이크로비드의 가교온도에 따른 팽윤특성)

  • Kim, Young-Hun;Lee, In-Kyu;Kim, Jin-Tae;Park, Ju-Hyun;Lee, Deuk Yong
    • Journal of the Korean Ceramic Society
    • /
    • v.49 no.6
    • /
    • pp.518-522
    • /
    • 2012
  • Hyaluronic acid (HA) microbeads were synthesized by dropping 0.5 wt% of sodium hyaluronate dissolved in NaOH into 0.2 vol% of divinyl sulfone dissolved in 2-methyl-1propanol at a speed of 0.005 ml/min. HA microbeads were collected from a divinyl sulfone crosslinker solution stirred at 200 to 400 rpm for 5 h at temperatures from room temperature to $60^{\circ}C$ at intervals of $10^{\circ}C$. The crosslinked microbeads were then cleaned thoroughly using distilled water and ethanol. SEM results revealed that the microbeads were white-colored spheres. The 3-D porous network structure of the microbeads became dense with an increase in the crosslinking temperature; however, no dependence of the crosslinking temperature on the microbead size was detected. The extent of swelling decreased from 970% to 670% with an increase in the crosslinking temperature from room temperature to $60^{\circ}C$, most likely due to the increase in the degree of crosslinking.

Experimental Evaluation of the Lighting Environment for Main Activities of the Residents in Living Room (거실 거주자의 주요 행위에 적합한 조명환경 평가 실험)

  • Kim, Hyun-Ji;Woo, Seong Jun;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.9
    • /
    • pp.6-14
    • /
    • 2013
  • The position of the light source, illuminance distribution, and color temperature were evaluated in each lighting environment for the three main activities in a living room - 'watching TV,' 'reading' and 'relaxing.' In 'watching TV', the experiment was done to estimate the degree of comfort felt by the subjects when they watch static video and moving video, respectably, with different ambient brightness, with or without partial lighting above the TV set, and with different color temperatures. In 'reading', the comfortableness was estimated by the illuminance ratio of the ambient lighting to the lighting for reading and by the difference in color temperature. And in 'relaxing', the comfortableness was estimated by means of the ambient brightness, use/no use of a relaxing lamp, and color temperature. This experiment determined the general satisfaction for each visual act and the optimum lighting environment to reduce glare.