선박 엔진룸의 소화용 분무노즐의 재료특성 및 유동해석 (Finite Element Analysis and Material Characteristics of Fire Spray Nozzle for Ship Engine Room)

  • 배동수;이진경
    • 한국산업융합학회 논문집
    • /
    • 제22권5호
    • /
    • pp.553-559
    • /
    • 2019
  • Various types of nozzles have been used to cope with fire in ships. However, in Korea, precise nozzles that perform fine spraying function are required for fire fighting in case of fire in a ship, and most of these nozzles depend on imports. Therefore, in this study, we developed various types of nozzles to develop the water spray nozzle for evolving fire in the engine room of the ship, and developed an optimal nozzle through flow analysis and fire test. For this purpose, we selected the materials that can satisfy the characteristics of existing nozzle materials and developed the design technology and processing technology in the nozzle considering fluid flow to achieve optimal water spraying performance. In order to develop an optimal nozzle, the flow through the finite element analysis was first analyzed and the nozzle was manufactured. As a result of flow analysis of the developed nozzle, the maximum velocity at the outlets of four holes at 0.3 MPa was about 3m/s and about 0.15 MPa. In addition, when the pressure at the inlet was 1.8 MPa, it showed the outlet speed of about 18m/s and a pressure of 1.2 MPa.

급기가압 제연설비의 내부 유동특성에 대한 수치해석 (Numerical Analysis on Flow Characteristics in the Pressurized Air Supply Smoke Control System)

  • 고권현
    • 한국화재소방학회논문지
    • /
    • 제31권4호
    • /
    • pp.52-58
    • /
    • 2017
  • 본 연구에서는 급기가압에 따른 건축물 내부의 공기유동에 대한 수치해석을 수행하고 거실, 부속실 및 계단실 간의 차압분포 및 유동 특성을 분석하였다. 유동 해석은 유효누설면적을 측정하기 위해 제작된 누기율 시험설비에 대하여 수행하였으며, 급기가압에 따른 각 실의 압력 및 유속분포 등을 분석하였다. 본 해석에서 공기의 누설은 유효누설면적을 갖는 얇은 틈새를 방화문과 창문에 위치시키는 방법으로 모사하였다. 이러한 방법을 이용한 해석은 계단실과 부속실 간의 차압에 대한 기존 실험의 결과를 적절히 예측하였다. 해석 결과를 통해 국부적인 누설이 급기가압 제연 설비의 전체적인 유동 패턴 및 압력 분포에 큰 영향을 미치지 않음을 확인하였다. 거실-부속실 문 단면에서의 평균속도가 방연풍속에 대한 국가화재안전기준을 만족하였으나 문의 상부와 같은 국부적인 위치에서 부속실로의 유출이 발생할 수 있음을 확인하였다.

공동주택 화재 시 부속실 가압 시스템의 방연풍속에 관한 수치해석적 연구 (Numerical Study on Air Egress Velocity of Ancillary Room Pressurization Systems in Apartment Fires)

  • 김병준;양영;신원규
    • 한국화재소방학회논문지
    • /
    • 제34권4호
    • /
    • pp.78-86
    • /
    • 2020
  • 본 연구에서는 공동주택 화재 시 부속실 가압 시스템의 방연풍속에 관하여 수치해석을 수행하였다. 수치해석을 통해 댐퍼의 급기량과 방화문에서의 방연풍속의 관계식을 선형적으로 나타내었고 국가화재안전기준인 방연풍속 0.7 m/s를 만족하는 댐퍼의 최소유량을 선정할 수 있었다. 댐퍼의 최소유량을 적용하여 댐퍼의 급기 방향과 설치 높이에 따라 방연속도를 분석하였다. 댐퍼의 급기 방향이 상향인 경우와 댐퍼가 높게 설치되었을 때 댐퍼의 급기 방향이 하향인 경우보다 방화문 상부에서 더 큰 방연풍속을 나타내었고 누출된 연기 농도가 더 낮은 것을 확인할 수 있었다. 따라서 방화문 상부에서 큰 방연풍속을 확보하는 것이 제연에 더 효율적일 것으로 판단된다.

건물화재의 플래시오버 도달 시간에 영향을 미치는 인자들에 관한 연구 (Parameter Effects on the Time to Reach Flashover Conditions in Single Room Fires)

  • 김형진;데이비드 릴리;백병준;박복춘
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1384-1388
    • /
    • 2003
  • In structural fires, flashover is characterized by the rapid transition in fire behavior from localized burning of fuel to the involvement of all combustibles in the enclosure. An investigation of parameter effects on the time to reach flashover conditions in a typical single room fire is undertaken using a zone method (FAST) and Thomas method. Major parameters affecting the time to reach flashover are found to be fire growth rate, ventilation opening area and internal room surface. The results of the FAST and the Thomas Method give very similar results of the time to reach flashover..

  • PDF

발코니 길이변화에 의한 화염분출성상의 실험적 고찰 (Experimental Study of the Blowoff Flame Phenomena Due to Changes of Balcony Length)

  • 김회천;손장열;박형주
    • 설비공학논문집
    • /
    • 제19권3호
    • /
    • pp.235-244
    • /
    • 2007
  • In the case of the fire outburst within a partitioned space, it can disappear inside it through smoldering process if the fire cannot obtain sufficient imflammability. On the contrary, if it obtains it, the fire is not restricted within the room, spreading to the higher levels beyond outside windows and the compartment room. The method to prevent the fire spread through windows is considered to build a balcony or equip with sprinkler facilities. This case study is to identify which effects and controlibility a balcony brings about on the spread of fire through a full scale model experiment. In order to understand the effects of fire spread on the upper levels of the room on fire by changing the length of balcony, the temperature was measured, radiant heat was investigated, and products of combustion were analyzed. The result showed that when fire occured, longer length of the balcony, which linked to the outside wall of the apartments, led to the blocking of the fire spread, lower level of radiant heat, and significantly less transfer of toxic gases, and the driving force of the outburst of flame was identified as the attractive force due to the turbulence of uncombusted gases, which exist on the upper level of the outbursting flame.

소화약제를 이용한 자동차 엔진룸 화재 실험에 관한 연구 (An Experimental Study on the Automobile Engine Room Fire Using the Extinguishing Agents)

  • 한용택;김동호;권성필
    • 한국화재소방학회논문지
    • /
    • 제28권4호
    • /
    • pp.1-7
    • /
    • 2014
  • 자동차의 엔진룸의 내부를 살펴보면 여러 가지의 장치 및 장비가 복잡하게 설치되어 있고 각종 오일 등의 인화물질을 포함하고 있어 재발화 가능성이 매우 높다. 또한, 폭발가능성도 높기 때문에 운전자나 탑승자가 보닛을 열고 엔진룸에 직접 분말 소화기를 분사하는 방식으로는 한계가 있다. 따라서 엔진룸 내부에서 화재를 감지하여 소화약제를 분사한 뒤, 화재를 진화하는 소화시스템과 엔진룸 내부의 고열에 견딜 수 있고, HFC-227ea를 포함하는 충분한 점성을 가진 폼 형태의 소화약제를 개발 및 시험하였다. 그리고 포소화약제가 가지고 있는 소화원리인 질식 및 냉각효과와 HFC-227ea가 가진 부촉매효과를 동시에 이끌어 내고, 소화 후에도 분말 소화기처럼 잔존물에 의한 2차 피해가 없는 맞춤형 소화약제를 개발하였으며, 차량을 이용한 충돌실험을 통하여 방출이 완료된 후에도 이물질 없이 소화약제를 제거할 수 있는 장점이 존재하는 실험결과를 획득하였다.

건물 내장재의 화재위험성 평가 방법 (A Fire Hazard Assessment of Interior Finish Materials)

  • 김운형
    • 한국화재소방학회논문지
    • /
    • 제12권2호
    • /
    • pp.17-28
    • /
    • 1998
  • 건물 화재시 예상되는 내장재의 실째 화재성농올 기준으로 한 위험성 명가방법올 제시하였다. 이률 위해 ISO Room Corner Test. (9705)를 기준으로 Qui ntie re의 화재확산 모델을 이용하여 내장재의 열 적 특성과 플래쉬 오버 도달시간과의 상관성을 유도하고 스쩨덴의 실제 시험결과와 비교 분석하였다. 이 결과, 내장재의 상대척인 화재위험성은 화재확산 변수 b륨 기준으로 명가될 수 있었다.