• Title/Summary/Keyword: Room fire

Search Result 528, Processing Time 0.039 seconds

Fire Examples Study of Intake and Exhaust System, Alternator Tuning and Inflow of Inflammables on Exhaust Part in a Car (자동차 흡배기장치, 발전기 튜닝 및 배기측 인화성 물질 유입에 관련된 화재사례 연구)

  • Lee, Il Kwon;Kook, Chang Ho;Suh, Moon Won;You, Chang Bae;Youm, Kwang Wook;Lim, Chun Moo;Jung, Dong Hwa
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.5
    • /
    • pp.47-51
    • /
    • 2014
  • This paper is to analyze and study the fire examples in respect of intake and exhaust, alternator tuning and inflow of inflammables on exhaust part in a car. In the first example, the driver diverted the intake and exhaust system for tuning of a car. Stopping a car to rest for moment, the flammable styrofoam scrap go into exhaust pipe that installed with exhaust manifold newly. It certified the fact that catched fire gradually, furthermore enlarged the fire by leaking fuel. In the second example, the driver enlarged the generator performance to divert the audio system in side room., it knew the fact that the electric wiring connected with generator gave the cause of outbreak a fire by overheating. In the third example, the serviceman replaced the engine oil using funnel-shaped, he put the a bottle of plastic pat onto engine cover carelessly. Consequentially, it found the fire occurrence in the engine room. Therefore, the driver never divert the intake and exhaust and generator construction of a car abnormally. Also, repairing and inspecting a car, the serviceman have a care to not occur the fire by inflammables.

Numerical studies on shear connectors in push-out tests under elevated temperatures

  • Wang, Aaron J.
    • Structural Engineering and Mechanics
    • /
    • v.39 no.3
    • /
    • pp.317-338
    • /
    • 2011
  • Three-dimensional thermal and mechanical coupled finite element models are proposed to study the structural behaviours of shear connectors under fire. Concrete slabs, steel beams and shear connectors are modelled with eight-noded solid elements, and profiled steel deckings are modelled with eight-noded shell elements. Thermal, mechanical and geometrical nonlinearities are incorporated into the models. With the proper incorporation of thermal and mechanical contacts among steel beams, shear connectors, steel deckings and concrete slabs, both of the models are verified to be accurate after the validation against a series of push-out tests in the room temperature or under the standard fire. Various thermal and mechanical responses are also extracted and observed in details from the results of the numerical analyses, which gives a better understanding of the structural behavior of shear connectors under elevated temperatures.

Electrocautery-Ignited Surgical Field Fire Caused by a High Oxygen Level during Tracheostomy

  • Kim, Myung-Su;Lee, Jang-Hoon;Lee, Dong-Hyup;Lee, Young Uk;Jung, Tae-Eun
    • Journal of Chest Surgery
    • /
    • v.47 no.5
    • /
    • pp.491-493
    • /
    • 2014
  • Tracheostomy is a relatively common surgical procedure that is performed easily in an operating room or intensive care unit. Open tracheostomy is needed in patients requiring prolonged ventilation when percutaneous tracheostomy is inappropriate. Sometimes, it is difficult to achieve bleeding control in the peritracheal soft tissue, and in such cases, we usually use diathermy. However, the possibility of an electrocautery-ignited surgical field fire can be overlooked during the procedure. This case report serves as a reminder that the risk of a surgical field fire during tracheostomy is real, particularly in patients requiring high-oxygen therapy.

A Study on Bending, Compressive Strength of Mortar According to Temperature and Heating Time Change using Oyster Shell as Aggregate (굴 패각을 골재로 사용한 모르타르의 온도별 가열 시간에 따른 휨·압축 강도에 관한 연구)

  • You, Nam-Gyu;Jung, Ui-In;Kim, Bong-Joo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.131-132
    • /
    • 2017
  • As the building is becomes bigger and larger, it can lead to big damage in case of fire. Also, tunnel, machine room and underground joint are spaces that can cause high temperature fire above 1,350℃ in case of fire. Therefore, a refractory material is need that can be withstand in high temperatures for long time. One side, the composition of oyster shell is CaCO3 of 90% or more. It is expected that it will be possible to use it as a high calcium natural material which is the material of the refractory board. According to, Study on bending, compressive strength of mortar according to temperature and heating time change using oyster shell as aggregate the most commonly occurring particle sizes form 2.5mm to 5mm.

  • PDF

A Study on the Slip Test of Shear Connector in Fire (전단 연결재의 고온 성능 평가에 관한 연구)

  • Han, Sang-Hoon;Park, Won-Sup;Lee, Choul-Ho
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.48-51
    • /
    • 2008
  • Shear connector is the element which resist in the horizontal shear force between steel and concrete of composite members and the stud bolt is often used because of its constructional convenience and serviceability. Although the push-out test is the most common method to evaluate shear slip behaviour, it is suitable for only room temperature conditions. In this study, we investigated about shear force, temperature distribution and slip displacement of shear connector in high temperature through the modified push-out test with electronic furnace invented for steel part heating.

  • PDF

Uncertainty Analysis of Fire Modeling Input Parameters for Switchgear Room of Nuclear Power Plants (원자력발전소의 스위치기어실 화재모델링 입력모수 불확실성 분석)

  • Kang, Dae-Il;Park, Jong-Seuk;Han, Sang-Hoon
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.53-60
    • /
    • 2011
  • 본 논문에서는 원자력발전소의 스위치기어실 화재로 인한 케이블 손상시간과 케이블 온도를 평가하기 위해 화재모델링 입력모수 불확실성 분석을 수행하였다. 화재모델링은 FDS 5.5를 사용하였으며 입력모수 샘플링은 Wilks 식에 따라 93회를 수행하였다. 단순히 입력모수 평균 값을 사용한 화재모델링 분석결과는 화재모델링 불확실성 분석결과보다, 케이블 손상시간은 최대 1.6배 늦게, 케이블 온도는 최대 0.45배 낮게 평가될 수 있는 것으로 나타났다.

  • PDF

A Case Study of Hybrid Air Conditioning and Ventilation System (환기 병용형 냉난방 시스템 설계 및 현장 적용 사례 연구)

  • Lee, Hong-Cheol;Hwang, In-Ju;Shin, Hyun-Joon
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.89-94
    • /
    • 2008
  • In this study it was evaluated that hybrid air conditioning and ventilation system to reduce energy consumption and keep on comfortable indoor environment in an underground shopping center. Room temperature by hybrid HAVC system was controled as $1.8{\sim}2.1^{\circ}C$ low and indoor humidity was controled as $4.1{\sim}5.0%RH$ low, and response was fast in $2.0{\sim}2.5$ times compared with conventional system. And also transportation efficiency of hybrid HVAC system was improved in about 27%, and total energy consumption rate of hybrid HVAC system is decreased in 16% compared with conventional system.

  • PDF

A study on bending, Compressive Strength of Mortar According to Temperature and Heating Time Change using Classified Oyster shell as Aggregate (분급한 굴 패각을 골재로 사용한 모르타르의 가열 시간에 따른 휨·압축 강도에 관한 연구)

  • You, Nam-Gyu;Hong, Sang-Hun;Jung, Ui-In;Kim, Bong-Joo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.122-123
    • /
    • 2017
  • As the building is becomes bigger and larger, it can lead to big damage in case of fire. Also, tunnel, machine room and underground joint are spaces that can cause high temperature fire above 1,350℃ in case of fire. Therefore, a refractory material is need that can be withstand in high temperatures for long time. One side, the composition of oyster shell is CaCO3 of 90% or more. It is expected that it will be possible to use it as a high calcium natural material which is the material of the refractory board. According to, Study on bending, compressive strength of mortar according to temperature and heating time change using classified oyster shell as aggregate.

  • PDF

A Study on the Fire Safety of Expanded Poly-Stylene Foam Panel (스치로폼 패널의 화재 안전성 연구)

  • Kweon, Oh-Sang;Yoo, Yong-Ho;Kim, Heung-Youl;Kim, Jung-Hyun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.513-519
    • /
    • 2009
  • 현재 국내의 주요 샌드위치패널 화재안전성능 평가방법에는 Cone calorimeter (연소성능) 및 가스유해성 시험방법이 있지만 샌드위치패널의 경우 불연재질 속 심재의 연소특성을 측정하여 실제 화재에서의 연소거동을 예측하기가 쉽지 않다. 따라서, 본 연구에서는 스티로폼 패널의 화재 안전성 연구를 위해서 ISO 9705 시험(Room Corner Test)을 실시하였다. 실험결과 두 시편 모두 시험이 진행되고 약 12분 정도, 버너의 열량이 100 kW에서 300 kW로 진행되는 시점에서 천정부가 붕괴되어 스티로폼 샌드위치 패널의 구조적인 문제점이 발생되었다. 스티로폼 샌드위치 패널은 내부 심재에 화염이 전파되었을 경우 급속한 화염의 전파 속도로 인해 구조적인 문제점을 발생되는 것을 확인할 수 있었으며, 향후 이와 같은 스티로폼 샌드위치 패널의 실물 화재 시험에 따른 연구 결과들이 화재안전 성능 등급 분류 기준 설정에 사용될 수 있을 것이다.

  • PDF

A Study on the Fire Door Performance Method of Pressurized Room for Special Evacuation Stairwells (특별 피난계단의 부속실 출입문 성능 방안에 관한 연구)

  • You, Woo-Jun;Nam, Jun-Seok;Ryou, Hong-Sun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.12-16
    • /
    • 2010
  • 본 연구에서는 건설현장의 특별 피난계단 출입문 크기와 구조의 다양성을 고려한 자동폐쇄장치의 설계방안을 제시하였다. 이를 위해서 급기가압실의 방연풍속, 누설량 그리고 송풍기의 용량이 일정한 경우 출입문이 폐쇄되기 위한 힘의 상관관계를 회전각도와 회전속도의 변화에 따라서 분석하였으며, 방화문의 폭이 1,100 mm, 1,300 mm 인 경우 각각에 대해서 개방력과 폐쇄력을 측정하였다. 그 결과 현장 조건을 만족할 수 있는 자동폐쇄장치에 의한 방화문의 폐쇄조건 및 회전각도와 회전속도의 변화를 고려한 개방력과 폐쇄력의 최적 설계범위가 존재함을 확인하였다.

  • PDF