• Title/Summary/Keyword: Room fire

Search Result 528, Processing Time 0.029 seconds

A Study on Design and Operation Performance of Automatic Fire Detection Equipment (P-type One-class Receiver) by Bidirectional Communication (양방향 통신이 가능한 자동화재탐지설비(P형 1급 수신기)의 설계 및 동작특성에 관한 연구)

  • Lee, Bong-Seob;Kwak, Dong-Kurl;Jung, Do-Young;Cheon, Dong-Jin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.2
    • /
    • pp.347-353
    • /
    • 2012
  • In this paper, authors will develop the quick and precise remote controller of automatic fire detection equipment (P-type one-class receiver) based on information communication technology (IT). The remote controller detects the fire and disaster in the building automatically and quickly and then activates the facilities to extinguish the fire and disaster, monitoring such situation in a real time through wire-wireless communication network. The proposed remote controller is applied a programmable logic device (PLD) micom. of one-chip type which is small size and lightweight and also has highly sensitive-precise reliabilities. The one-chip type PLD micom. analyzes digital signals from sensors, then activates fire extinguishing facilities for alarm and rapid suppression in a case of fire and disaster. The detected data is also transferred to a remote situation room through wire-wireless network of RS232c and bluetooth communication, and then the situation room sends an emergency alarm signal. The automatic fire detection equipment (AFDE) based on IT will minimize the life and wealth loss while prevents fire and disaster.

Simulation of a Clean Room Fire I. Effects of Smoke Curtain (청정실 화재의 시뮬레이션 I. 방연커튼의 효과)

  • Park Woe-Chul
    • Fire Science and Engineering
    • /
    • v.19 no.2 s.58
    • /
    • pp.8-12
    • /
    • 2005
  • A fire in a clean room may cause a serious loss by spreading smoke particles. The effects of the width of smoke curtains on delay in smoke spread, which is located the work area boundaries, were investigated by using a computational fluid dynamics, for loss prevention by smoke spreading from one fire area to another. The fire scenario was set to a 1 MW methanol fire in a space of $30m\times10m$ floor and 4 m high. Distributions of temperature and smoke particles were compared for the width of the smoke curtains 0 (without smoke curtains), 1, 2, 3m. It was confirmed that a larger width of the smoke curtain delays spread of smoke more, and that making the work areas compartments is necessary to confine the smoke in the fire area.

A Study on the Performance of a Sprinkler System with Direct-Coupled Waterworks by Full-Scale Fire Test (실화재실험을 통한 상수도 직결형 스프링클러시스템의 성능에 관한 연구)

  • Jung, Jong-Jin;Nam, Dong-Gun;Lim, Woo-Sub
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.39-43
    • /
    • 2011
  • In this research, full-scale fire test was performed on a real house for the evaluation of the performance of waterworks direct-coupled sprinkler system. The fire was set to occur as spontaneous combustion as the cooking oil overheats. The size of house is $56m^2$ and it consists of a living room, a kitchen, and a room. In order to verify the performance of waterworks direct-coupled sprinkler system, it was installed in the kitchen. The result of the test showed that the fire started from the kitchen enlarged up to its ceiling but it was soon exhausted as the sprinkler started to work. The pressure of the waterworks was 0.28 MPa when the sprinkler operated, by which it verified that fire could go out even by waterworks pressure of the general residence.

A Study for the Fire Hazard Evaluation through the Fire Simulation of an Apartment Fire Accident (아파트 화재 사례 전산모사를 통한 화재위험성 평가에 관한 연구)

  • Jeon, Heung-Kyun;Choi, Young-Sang;Choo, Hong-Lok
    • Fire Science and Engineering
    • /
    • v.24 no.4
    • /
    • pp.69-78
    • /
    • 2010
  • In this study, Fire Hazards were evaluated through computer simulation using FDS program for an apartment fire accident. The results of fire simulation showed that the maximum heat release rate in the case of no sprinklers activation was 7,700 kW which was about 16 times of that in the case of sprinklers activation, 497 kW and there was a very high fire hazard due to the backdraft phenomenon when the door of fire room was forced to open. Regarding the hazard time of fire room temperature and detection time of detectors, available evacuation time was 32.5 seconds of minimum to 53.5 seconds of maximum. In the case of sprinklers activation, fire hazard in the apartment was showed to be very low due to the fire control by the spray cooling of sprinklers. This study shows that what a important function for fire safety is the activations of fire sprinkler system and emergency alarm system and what a large loss can cause if these systems don’t activate in fire accidents.

Fire Extinguishing Capability of an Automatic Spreading Fire Extinguisher in Accordance with Horizontal Distance from a Fire Source (자동확산소화장치의 이격거리에 따른 소화성능평가연구)

  • Kwark, Ji-Hyun;Kim, Dong-Suk;Ku, Jae-Hyun
    • Fire Science and Engineering
    • /
    • v.27 no.5
    • /
    • pp.38-43
    • /
    • 2013
  • An automatic spreading fire extinguisher usually installed in a closed area like a boiler room, a laundry store or a restaurant's kitchen room is one of the fire protection equipments. This extinguisher automatically discharges dry powder, extinguishing fire. As this extinguisher has the extinguishing capability applicable to the nominal protection area, objects outside the area cannot be properly extinguished. However only its number is being requested according to the floor area in the related laws, and the extinguishing capability depends on the distance from a fire source. In this study we tried to investigate the extinguishing capability of the automatic spreading fire extinguisher in accordance with horizontal separation distance from a fire source. It appeared that the maximum horizontal separation distance was about 30 cm for both class A and B fire to be certainly extinguished.

Investigation of the Relationship Between Wall Thermal Conductivity and Inner Room Temperature in Compartment Fires (구획화재에서 벽면의 열전도 계수와 내부 온도의 상관관계 분석)

  • You, Woo Jun;Ko, Gwon-Hyun
    • Fire Science and Engineering
    • /
    • v.32 no.2
    • /
    • pp.17-23
    • /
    • 2018
  • In this study, the relations of the wall thermal conductivity and surface temperature in a compartment fire are investigated using Buckingham Pi theorem. The dimensionless parameters of the previous study are analyzed in order to correlate the dimensionless groups of the heat release rate, the thermal conductivity, the volume of compartment and the convective heat transfer coefficient. In addition the reduced scale of compartment, which has 1/6 size of ISO 9705 Room Corner Tester, is manufactured and the oxygen concentration and the maximum temperature in the space are measured for the gasoline pool fire ($10cm{\times}10cm$, $15cm{\times}15cm$ and $20cm{\times}20cm$). Finally, the criterion of the wall temperature increase are suggested in accordance with the thermal conductivity and the convective heat transfer coefficient. In addition, the dimensionless empirical equation using Buckingham Pi theorem considering the heat release rate are presented suggested. The results of this study will be useful especially for the fire phenomenon investigation of the wall thermal conductivity coefficient and shape in the compartment space.

The Development of Flow Control Ventilation Damper According to the Pressure Variation of Smoke Control Room (제연구역의 압력변화에 따른 풍량제어 배출댐퍼 개발)

  • Lee, Dong-Myung
    • Fire Science and Engineering
    • /
    • v.32 no.4
    • /
    • pp.69-74
    • /
    • 2018
  • This study developed a ventilation damper that can control flow rate according to pressure differential variation of the smoke control room in order to improve problems related to existing smoke management systems and maximizing performance of smoke management systems. The development damper was tested for verification of utility and performance. The supply flow of the developed ventilation damper was increased by about 1 to 5%. The results prove the effectiveness of the flow control ventilation damper by providing stable flow over the designed flow of the fan in the smoke control room. In addition, the study acquired the original technology for a flow control ventilation damper.

A Numerical Study on the Effect of Volume Change in a Closed Compartment on Maximum Heat Release Rate (밀폐된 구획실의 체적변화가 최대 열발생률에 미치는 영향에 관한 수치해석 연구)

  • Yun, Hong-Seok;Nam, Dong-Gun;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.19-27
    • /
    • 2017
  • The effects of changes in area and location of fire source, fire growth rate, and volume of compartment on the major fire characteristics, including heat release rate, in closed compartment fires were examined. To this end, a fire simulation using Fire Dynamics Simulator (FDS) was performed for ISO 9705 room with a closed opening. As main result, it was found that the changes in the area and location of fire source did not significantly affect the thermal and chemical characteristics inside the compartment, such as maximum heat release rate, total heat release, maximum temperature at upper layeras well as species concentrations. However, increasinthe fire growth rate and volume of compartment resulted in increase of the maximum heat release rate and total heat release, decrease in the limiting oxygen concentration and increase in the maximum CO concentration. Finally, a methodology for the application of fire growth curves to closed compartment fires was proposed by deriving the correlation of the maximum heat release rate expressed as a function of the fire growth rate and the volume ratio of compartment based on the ISO 9705 room.

A Study on the Reverberation Time Characteristics of Inside Space of Apartment Buildings (공동주택 내부 공간의 잔향시간 특성 조사 연구)

  • Jeong, Jeong Ho;Lee, Byung Kwon;Jeon, Jin Yong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.4
    • /
    • pp.291-298
    • /
    • 2015
  • In this study, the reverberation time of apartment living room was measured and distribution of the reverberation time was analyzed. In addition, sound field characteristics of mock-up test room similar with living room and timber structured bedroom was investigated with addition of furniture and sound absorption material. Average reverberation time of unfurnished apartment unit was 1.11 s, and reverberation time in 630 Hz~2000 Hz bands were longer than 1.2 s. It was found that from the field measurement results, reverberation time characteristic of furnished apartment living room was uniform in most of frequency bands. Averaged reverberation time of furnished living room was 0.48 s and the reverberation time of bedroom was 0.44 s. Standardized sound pressure level correction values were calculated from the average reverberation time of furnished and unfurnished apartment units. The correction value of unfurnished living room was −3.4 dB and that of furnished living room was 0.2 dB. Measured reverberation time of furnished and unfurnished apartment units indicated that reference reverberation time; 0.5 s, in KS and ISO standards is reasonable also in Korean residential environment.

A Study on the Effect of Inflammable Materials on the Control Characteristics of Thermal and Smoke Fluid of Water Curtain System (가연성 물질에 따른 워터커튼 시스템의 열 및 연기유동 제어특성에 관한 연구)

  • You, Woo-Jun;Nam, Jun-Seok;Kim, Dong-Joon;Lee, Jeong-Kyoon;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.26 no.2
    • /
    • pp.53-58
    • /
    • 2012
  • In this study fire control characteristics for inflammable materials of water curtain system are experimentally analyzed. Heat release rate for pinewood and gasoline was calculated using Room Corner Tester (RCT) and fire test apparatus for water curtain system is manufactured. Nozzles (180 degree of injection angle, 8.2 mm of orifice diameter) are installed at the nearby ceiling of place at 5 m distance from fire originate and temperature profile as well as transmission are obtained from the fire experiment of pinewood and gasoline in the water curtain system. Based on the results, parameters of engineering importance for fire control characteristics of water curtain system such as generation of high temperature smoke and thermal phenomena of fluid flow by injection nozzle are identified.