• 제목/요약/키워드: Rogowski sensor

검색결과 25건 처리시간 0.027초

Design and fabrication of an optimized Rogowski coil for plasma current sensing and the operation confidence of Alvand tokamak

  • Eydan, Anna;Shirani, Babak;Sadeghi, Yahya;Asgarian, Mohammad Ali;Noori, Ehsanollah
    • Nuclear Engineering and Technology
    • /
    • 제52권11호
    • /
    • pp.2535-2542
    • /
    • 2020
  • To understand the fundamental parameters of Alvand tokamak, A Rogowski coil with an active integrator was designed and constructed. Considering the characteristics of the Alvand tokamak, the structural and electrical parameters affecting the sensor function, were designed. Calibration was performed directly in the presence of plasma. The sensor has a high resistance against interference of external magnetic fields. Plasma current was measured in various experiments. Based on the plasma current profile and loop voltage signal, the time evolution of plasma discharge was investigated and plasma behavior was analyzed. Alvand tokamak discharge was divided into several regions that represents different physical phenomena in the plasma. During the plasma discharge time, plasma had significant changes and its characteristic was not uniform. To understand the plasma behavior in each of the phases, the Rogowski sensor should have sufficient time resolution. The Rogowski sensor with a frequency up to 15 kHz was appropriate for this purpose.

저온소성 다층 세라믹 기판에 로고스키코일을 내장한 전류센서에 관한 연구 (A study on the application of Rogowski coil on the LTCC)

  • 박성현;김은섭;신병철
    • 센서학회지
    • /
    • 제19권6호
    • /
    • pp.475-482
    • /
    • 2010
  • Rogowski coil which detects magnetic flux on current changes. It is used for digital integration with watt-hour meter's current sensor, because, Rogowski coil has non-cored or non-magnetic core structure, so that, it cannot be saturated magnetically. This is a study for inventing accurate electric current sensors that have been applied on multi-layer ceramic substrate. We have confirmed its properties from each different layer's materials and pattern sizes by MWS 3D Electromagnetic field analysis program. And, after sensor manufacturing on multi-layer ceramic substrate, we confirmed its sensing quality is reliable as accurate electric current sensor for watt-hour meter.

저전류 영역에서 로고우스키 코일 특성 (Characteristics of Rogowski coil at Low Cutrrent Region)

  • 박정남;이강원;이청;김길수;박영국;강성화;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.47-50
    • /
    • 2001
  • Conventionally, air-cored Rogowski coil was designed for use as high alternating and transient current sensor without saturation caused by ferromagnetic material in its core. This paper investigated that Rogowski coil can be applied to low current measurement in 60Hz power line. Measured parameters R, L of coil were compared with theoretically calculated values. Output voltages crossed by Rogowski coil have shown some linearity according to input current(tens to thousands of amperes) passing through it. And also shielding effect for external noises was investigated for three cases.

  • PDF

부분방전전류측정을 위한 로고스키코일의 적용에 관한 연구 (Study about the Application of Rogowski Coil for measuring Partial Discharge Current)

  • 이강원;윤성철;김명룡;백광선;나동희
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.1378-1383
    • /
    • 2004
  • Rogowski coil is a kind of sensor for high amplitude and very short period current and suitable for the measurement of PD pulse. This paper have simulated the relations between PD signals and Rogowski coil which has its own equivalent circuit and investigated signals of Rogowski coil induced by PD pulse current. and compared with the PD signal obtained from conventional PD measuring system in accordance with IEC60270.

  • PDF

로고스키코일을 이용한 기중 방전 신호 검출 (Air Discharge Detection using Rogowski Coil)

  • 박성희;이용희;이강원;김길수;강성화;임기조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1884-1886
    • /
    • 2002
  • At present, the variable sensors are applied to detect PD pulse signals, UHF sensor, AE sensor and etc. In this paper we used the Rogowski sensor to detect PD pulse signals in air. We did performed test simulation and niddle to plane electrode structure for PD source. We compared Rogowski sensor with conventional type PD detector to detect discharge signals in air.

  • PDF

100kA 급 급준 펄스 대전류 측정을 위한 Rogowski형 전류 측정장치 (Rogowski Current Sensor for 100kA class Steep Pulse Measurement)

  • 이상욱;장용무
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.186-187
    • /
    • 2006
  • In this paper, for measuring 100kA class steep pulses, Rogowski pulse current sensor has been designed by EMD and then calibrated with discharged circuit. The operation range of designed sensor is 20 kHz$\sim$50 MHz, 1$\sim$100 kA.

  • PDF

전류측정감도 개선을 위한 로고우스키 코일의 설계 (Design of Rogowski coil to improve of current measurement sensitivity)

  • 박정남;이청;장용무;강성화;임기조;나동희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.609-612
    • /
    • 2001
  • Rogowski coil is made having no ferromagnetic material in a core. So the coil cannot be driven into saturation. This result in that Rogowski coils may be calibrated at relatively low currents. and used with confidence at very high currents. However the lowest level of current that can be measured is limited by the sensitivity of the voltage measuring instrument and system noise. Therefore. geometrical effects were investigated in order to measure high sensitivity of low level current and the significant source of error was examined as well. In the results, the source of error was associated with coil designs. i.e. shape and uniformity of coil and a geometrical location of current source inside and outside of the Rogowski coil.

  • PDF

전류측정감도 개선을 위한 로고우스키 코일의 설계 (Design of Rogowski coil to improve of current measurement sensitivity)

  • 박정남;이청;장용무;강성화;임기조;나동희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.609-612
    • /
    • 2001
  • Rogowski coil is made having no ferromagnetic material in a core. So the coil cannot be driven into saturation. This result in that Rogowski coils may be calibrated at relatively low currents, and used with confidence at very high currents. However the lowest level of current that can be measured is limited by the sensitivity of the voltage measuring instrument and system noise. Therefore, geometrical effects were investigated in order to measure high sensitivity of low level current and the significant source of error wa examined as well. n the results, the source of error was associated with coil designs, i.e. shape and uniformity of coil and a geometrical location of current source inside and outside of the Rogowski coil.

  • PDF

로고우스키코일을 이용한 과도전류의 측정 (Measurement of Transient Current by using the Rogowski Coil)

  • 이복희;길경석;정승수;정상진
    • 대한전기학회논문지
    • /
    • 제43권7호
    • /
    • pp.1206-1213
    • /
    • 1994
  • This paper presents the operation principle and design rule of the Rogowski coil which can measure the transient current and describes the calibration and application experimental results for performance evaluation. It is obtained that the response curves of the Robowski coil with the turns of 300 and the passive integrator to sinusoidal input give a good linearity up to the frequency of 500 [kHz] and the current measurement system gaving the Rogowski coil is the frequency bandwidth of 40 [Hz]~700 [kHz]. As an application experiment for the fabricated modeling power transmission line, the impulse current, which limitates the direct lightning return stroke to overhead ground wire, is measured by the Rogowski coil and its fast Fourier transformation is carried out. The equivalent circuit of the Rogowski coil considering the stray capacitances is proposed, and the theoretical analysis is in good agreement with the measurement results. Also, it is found that for high frequency domain the stray capacitance such as a distributed capacitance to the shield and the capacitance between windings of coil should be considered in designing the Rogowski coils since the resonance originates from the stray capacitance and the self-inductance of the Rogowski coil.

  • PDF

170kV GIS용 Rogowski coil형 CT개발 (Development of Rogowski-Coil Type CT for Application in 170kV GIS)

  • 정영환;김정배;송원표;김덕수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.479-481
    • /
    • 2001
  • Traditionally, instrument transformer of the ferromagnetic core type have been used for measuring current in GIS(Gas Insulated Switchgear). Recently, with the introduction of digital technology at the protection relay or measurement device level, the use of new current sensor can be foreseen. Current measurement by means of Rogowski coil is just one illustration of this. This paper describes the progress of development of Rogowski-coil type CT for application in 170kV GIS.

  • PDF