Development of Real-time Checking System on Ringer's Solution Using Load Cell

  • Ha, Kwan-Yong;Nam, Chul;;Kim, Hie-Sik
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1409-1412
    • /
    • 2005
  • Therefore this study focused on developing real-time system, which makes it possible for nurses to check the residual quantity and changing time of Ringer's solution in nurses' room. Load Cell is utilized as a sensor to check the residual quantity of Ringer's solution. This Load Cell detects the physical changes of Ringer's solution and transfers electronic signal to the amplifier. Amplified analog signal is converted into digital signal by A/D converter. Developed Embedded system, which computes these data with microprocess(8052) then makes it possible to monitor the residual quantity of Ringer's solution real-time on a server computer. A Checking system on Residual Quantity of Ringer's Solution Using Load cell cut costs using a simple design for a circuit

  • PDF

링거액 주입시의 부피팽창 효과에 대한 모델링 (Modeling of Volume Expansion Effects During Infusion of Ringer's Solution)

  • 이은호;최규택;여영구
    • 제어로봇시스템학회논문지
    • /
    • 제12권12호
    • /
    • pp.1191-1196
    • /
    • 2006
  • In this work the kinetics of volume changes of fluid spaces associated with infusion of Ringer's solution are analyzed using the body fluid space model. During infusion of Ringer's solution, the human body is assumed to be characterized by the fluid space model into which fluid is fed and from which fluid is left. Various infusion types were tested to accommodate different medical situations. Volunteers were given Ringer's solution and the changes in blood hemoglobin were detected. From the comparison with experimental data, the single- and two-fluid space models were found to represent adequately the kinetics of human volume expansion during infusion of Ringer's solution.

링거액 소진 감지를 위한 정전용량방식의 차동센서 설계 및 제작 (Design & implementation of differential sensor using electrostatic capacitance method for detecting Ringer's solution exhaustion)

  • 심요섭;김청월
    • 센서학회지
    • /
    • 제19권5호
    • /
    • pp.391-397
    • /
    • 2010
  • This paper proposes a differential structure sensor for detecting Ringer's solution exhaustion, in which three C-type electrodes of 10 mm width are disposed on a ringer hose at a distance of 5 mm each other in the direction of Ringer's solution flow. In the center of middle electrode, two capacitances are formed at the proposed sensor. When ringer hose is filled with Ringer's solution, there is no difference between two capacitances. But capacitance difference exist under the Ringer's solution shortage, because the shortage causes the hose filled with air from the top position electrode. The capacitance difference got to maximum 1.81 pF, when air was filled between top and middle electrode and the last of hose was filled with 10 % dextrose injection Ringer's solution. The capacitance difference varied with hose-wraparound coverage of electrodes as well as the width of them. For hose-wraparound electrode coverage of 90 % and 70 %, the maximum capacitance difference was 1.81 pF and 1.56 pF, respectively. A differential charge amplifier converted the capacitance difference to electric signal, and minimized electrodes' adhering problem and external noise coupling problem.

마이크로프로세서를 이용한 병원용 환자 링거액 잔류유량 원격 실시간 검사 시스템 개발 (Development of a Remote Monitoring System of the Residual Amount of Ringer's Solution at Hospitals Using a Microprocessor)

  • 하관용;권종원;오드게렐;김희식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.279-282
    • /
    • 2005
  • A real-time measurement and control system was developed, This system is used for nurses at hospitals to check the residual quantity and changing time of Ringer's solution in nurses' room. Load Cell is utilized as a sensor to check the residual quantity of Ringer's solution, This Load Cell detects the physical changes of Ringer's solution and transfers electronic signal to the amplifier. Amplified analog signal is converted into digital signal by NO converter. Developed Embedded system, which computes these data with microprocess(8052) then makes it possible to monitor the residual quantity of Ringer's solution real-time on a server computer. A Checking system on Residual Quantity of Ringer's Solution Using Load cell cut costs using a simple design for a circuit

  • PDF

효율적인 환자관리를 위한 링거액 감지기 및 송수신기 설계 (Ringer's solution detector and transceiver design for efficient manage of patient)

  • 송제호;이인상;이유엽
    • 한국산학기술학회논문지
    • /
    • 제17권9호
    • /
    • pp.45-50
    • /
    • 2016
  • 본 논문에서는 효율적인 환자관리를 위한 링거액 감지기 및 송수신기를 설계 하고자 한다. 링거액 감지기 및 송수신기는 메인 제어부, 링거액 감지부, 디스플레이 및 경고 발생부, 무선 송수신부, 전원 공급부로 구성된다. 메인 제어부에서는 GC89L591A0-MQ44IP의 CPU를 사용하여 전체 시스템을 제어하고 링거액 감지부는 수광부에 TSL235R-LF 포토다이오드, 투광부에 Water-Clear Type LED를 적용하였다. 또한, 디스플레이 및 경고 발생부는 7-세그먼트와 적색 LED를 적용하였으며 무선 송수신부는 NR-FPCX 모듈을 사용하여 데이터를 송수신하였다. 전원 공급부는 건전지를 사용하며 일반 전원이나 충전식 전원도 사용할 수 있도록 하였다. 따라서, 효율적인 환자관리를 위한 링거액 감지기 및 송수신기 설계에 대한 연구 결과 링거액이 포토다이오드에 의해 감지되었을 때 주파수는 11.95kHz이며, 감지되지 않았을 때는 9.6kHz로 측정되었다. 이때, 링거액의 감지 데이터가 링거액 송신기를 통해 출력되지 않을 때는 "0" 으로, 출력되었을 때는 해당 병실의 호실 정보가 링거액 수신기에 표시됨을 확인 할 수 있었다. 또한, 링거액 감지기의 사용전원은 신호가 감지되지 않을 때에는 Sleep 모드로 전환하여 배터리 절약 모드로 동작하며 링거액 송수신기는 대략 700m이내의 거리에서 무선 송수신이 가능하다.

수액제에 유입되는 실내 유기오염물질의 거동 (Behavior of Indoor Organic Pollutants Dissolved into the Ringer's Solution)

  • 김만구;정영림
    • 한국대기환경학회지
    • /
    • 제12권3호
    • /
    • pp.315-322
    • /
    • 1996
  • Recently, hospital acquired infections have an increase interest as a public problems, which are caused of indoor pollutants in hospital. Microorganisms, ethylene oxide, formaldehyde, and anesthetic gases are main hazardous pollutants in hospital. The possible pathways of the infection are a respiratory channel as well as a blood channel. The blood channel is concerned since these pollutants might be dissolved into the Ringer's solution. The objective of this research was to evaluate the removal efficiencies of adsorption trap for formaldehyde and microorganisms as indoor pollutants which permeated into the Ringer's solution. Dissolved formaldehyde in the solution was increased with the injection dose time. The amount of dissolved formaldehyde was 67.5 $\pm$ 9.5% in Ringer's solution when injection dose time was controlled about 7hrs. An adsorption trap was designed for preventing formaldehyde and microorganisms to be permeated into Ringer's solution. The adsorption trap was packed with 0.4g of active carbon (60/80 mesh) in a sterilized plastic tube (7.79 cm length, 0.46 cm i.d.) and both ends were packed with glass wool. Devised infusion set equipped with the adsorption trap showed 99.9% of removal efficiency for formaldehyde. Microorganism numbers detected on sterilized water for injection and 5% dextrose infusion used in the hospital were 2,695 $\times 10^3$ cells/l and 4,190 $\times 10^3$ cells/l, respectively. Removal efficiency by the adsorption trap was 92.3 $\pm$ 8.5% as for microorgnisms.

  • PDF

링거 자동 교체를 위한 잔량 검출 알고리즘 (An Algorithm for Detecting Residual Quantity of Ringer's Solution for Automatic Replacement)

  • 김창욱;우상효;지아모이우딘;원철호;홍재표;조진호
    • 한국산업정보학회논문지
    • /
    • 제13권1호
    • /
    • pp.30-36
    • /
    • 2008
  • 최근 POC (Point of care)와 같은 의료서비스의 질을 높이기 위한 연구가 많이 진행되고 있다. 서비스의 질을 높이기 위해서는 장비뿐만 아니라 간호사 인력의 확충이 매우 중요하다. 그러나 현재 대한민국의 간호사 인력은 매우 부족하며, OECD 국가 중 최하위를 기록하고 있다. 많은 간호사의 업무중 단순 반복적인 업무를 대체할 경우, 추가적인 인건비 없이도 고급의 간호 인력을 다른 업무에 사용할 수 있다. 수많은 단순 반복적인 간호사 업무 중에는, 본 논문에서는 링거액을 교체하는 업무에 초점을 맞추었다. 그러므로 본 논문에서는 링거의 자동 교체를 위하여, 먼저 링거의 잔량을 검출하는 알고리즘을 구현하였다. 구현된 알고리즘은 실제 현장에 사용할 때 많이 발생할 수 있는 조명 문제의 해결을 위하여 수정된 SQI 알고리즘을 사용하였으며, 이후 간단한 히스토그램 누적 방법을 이용하여 링거의 잔량을 검색하였다. 구현된 알고리즘은 링거 교체에 사용될 수도 있으며, 간호사들에게 경보를 주는 곳에도 사용할 수 있다.

  • PDF

정전용량변화를 이용한 링거액소진감지장치의 구현 (Implementation of apparatus for detecting Ringer's solution exhaustion using electrostatic capacitance variation)

  • 김청월
    • 센서학회지
    • /
    • 제19권1호
    • /
    • pp.1-7
    • /
    • 2010
  • Electrostatic capacitance measurement method in a fine hose was proposed, in which two ring-type electrodes were disposed on the hose in the direction of fluid flow instead of the conventional face-to-face electrodes. With the proposed electrode structure, we realized a Ringer's solution exhaustion detector for an IV(invasive vein) injection set. On a 4 mm-diameter hose of IV set, we disposed two ring-type electrodes of 10 mm width at a distance of 5 mm each other and obtained 0.72 pF and 2.51 pF for air and 10 % dextrose Ringer's solution in the hose, respectively. The capacitance between the two electrodes varied with the hose-wraparound coverage of electrode as well as the width of electrode and the distance between the electrodes. For hose-wraparound electrode coverage of 75 %, the capacitance varied from 0.62 pF to 1.98 pF with the Ringer's solution level between the two electrodes. A charge amplifier converted the capacitance. variation into electric signal and a comparator was used to detect whether Ringer's solution was exhausted or not. The result was delivered to a host using a RF transmitter with 320 MHz carrier frequency.

비접촉 IoT 링거 교체 자동 알림 시스템 설계 및 구현 (Design and Implementation of Non-contact IoT Ringer Replacement Automatic Notification System)

  • 이효승;오재철
    • 한국전자통신학회논문지
    • /
    • 제13권6호
    • /
    • pp.1405-1410
    • /
    • 2018
  • 의료기관에서 사용하는 링거는 몸에 수분을 공급하여 열이나 탈수 상태에 있던 몸의 상태를 회복시켜 주는데 도움을 주는 주사제 중 하나로 의료진이 해당 환자에게 처방된 링거의 양을 수시로 점검하여 링거의 교체 시기를 확인하여야 한다. 하지만 현재 간호사 인력은 매우 부족하고 부여된 업무량도 적지 않아 업무에 부하가 발생하게 되고 이로 인하여 환자 및 보호자에게 양질의 의료서비스를 제공하지 못하게 된다는 문제점이 발생하게 된다. 이러한 문제점을 해결하기 위해 본 논문에서는 비접촉식 센서와 WiFi통신방식을 이용한 IoT 디바이스와 OCS 연동을 통한 링거 교체 시기 관제 시스템을 설계하고 구현함으로써 의료진에게 해당 환자의 링거 자동 교체 타이밍을 알려 과거 비효율적이던 중간 단계를 생략함으로써 링거 교체 업무를 효율적으로 운영하고 환자 및 보호자에게 양질의 의료서비스를 제공할 수 있기를 기대한다.

슬관절 관절경 수술시 세척액 - 생리 식염수와 Lactated Ringer 용액의 비교 (Irrigation Solutions in the Knee Arthroscopy - Comparison with Normal Saline and Lactated Ringer's Solution)

  • 이우석;배인탁;허윤무;박원기;오병학;정환용
    • 대한관절경학회지
    • /
    • 제12권2호
    • /
    • pp.125-128
    • /
    • 2008
  • 목적: 슬관절 관절경하 반월상 연골 수술 시 생리 식염수와 Lactated Ringer 용액을 세척액으로 사용하여 임상적인 결과를 분석하고자 하였다. 대상 및 방법: 내측 반월상 연골 파열로 관절경하 내측 반월상 연골 부분 절제술을 시행한 64예를 대상으로 하였다. 제 I 군은 세척액으로 생리 식염수를 사용한 군으로, 제 II 군은 세척액으로 Lactated Ringer 용액을 사용한 군으로 분류 하였다. 수술 후 1일째의 visual analogue scale, 능동적 슬관절 굴곡 각도 및 슬관절 둘레의 증가율를 측정하여 비교 분석하였다. 결과: 수술 후 1일째의 visual analogue scale 및 능동적 슬관절 굴곡 각도의 비교는 통계학적으로는 두군 간에 유의성은 없었다. 그러나 수술 후 슬관절 둘레의 증가는 Lactated Ringer 용액을 사용한 군에서 생리 식염수를 사용한 군에 비해 통계학적으로 유의하게 적었다. 결론: 슬관절 반월상 연골 수술 시 Lactated Ringer 용액이 수술 후 부종의 감소에 생리 식염수보다 좋을 것으로 사료된다.

  • PDF