• 제목/요약/키워드: Ringer

검색결과 148건 처리시간 0.281초

Development of Real-time Checking System on Ringer's Solution Using Load Cell

  • Ha, Kwan-Yong;Nam, Chul;;Kim, Hie-Sik
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1409-1412
    • /
    • 2005
  • Therefore this study focused on developing real-time system, which makes it possible for nurses to check the residual quantity and changing time of Ringer's solution in nurses' room. Load Cell is utilized as a sensor to check the residual quantity of Ringer's solution. This Load Cell detects the physical changes of Ringer's solution and transfers electronic signal to the amplifier. Amplified analog signal is converted into digital signal by A/D converter. Developed Embedded system, which computes these data with microprocess(8052) then makes it possible to monitor the residual quantity of Ringer's solution real-time on a server computer. A Checking system on Residual Quantity of Ringer's Solution Using Load cell cut costs using a simple design for a circuit

  • PDF

Design & implementation of differential sensor using electrostatic capacitance method for detecting Ringer's solution exhaustion (링거액 소진 감지를 위한 정전용량방식의 차동센서 설계 및 제작)

  • Sim, Yo-Sub;Kim, Cheong-Worl
    • Journal of Sensor Science and Technology
    • /
    • 제19권5호
    • /
    • pp.391-397
    • /
    • 2010
  • This paper proposes a differential structure sensor for detecting Ringer's solution exhaustion, in which three C-type electrodes of 10 mm width are disposed on a ringer hose at a distance of 5 mm each other in the direction of Ringer's solution flow. In the center of middle electrode, two capacitances are formed at the proposed sensor. When ringer hose is filled with Ringer's solution, there is no difference between two capacitances. But capacitance difference exist under the Ringer's solution shortage, because the shortage causes the hose filled with air from the top position electrode. The capacitance difference got to maximum 1.81 pF, when air was filled between top and middle electrode and the last of hose was filled with 10 % dextrose injection Ringer's solution. The capacitance difference varied with hose-wraparound coverage of electrodes as well as the width of them. For hose-wraparound electrode coverage of 90 % and 70 %, the maximum capacitance difference was 1.81 pF and 1.56 pF, respectively. A differential charge amplifier converted the capacitance difference to electric signal, and minimized electrodes' adhering problem and external noise coupling problem.

Modeling of Volume Expansion Effects During Infusion of Ringer's Solution (링거액 주입시의 부피팽창 효과에 대한 모델링)

  • Lee, Eun-Ho;Choi, Kyu-Taek;Yeo, Yeong-Koo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • 제12권12호
    • /
    • pp.1191-1196
    • /
    • 2006
  • In this work the kinetics of volume changes of fluid spaces associated with infusion of Ringer's solution are analyzed using the body fluid space model. During infusion of Ringer's solution, the human body is assumed to be characterized by the fluid space model into which fluid is fed and from which fluid is left. Various infusion types were tested to accommodate different medical situations. Volunteers were given Ringer's solution and the changes in blood hemoglobin were detected. From the comparison with experimental data, the single- and two-fluid space models were found to represent adequately the kinetics of human volume expansion during infusion of Ringer's solution.

Development of a Remote Monitoring System of the Residual Amount of Ringer's Solution at Hospitals Using a Microprocessor (마이크로프로세서를 이용한 병원용 환자 링거액 잔류유량 원격 실시간 검사 시스템 개발)

  • Ha, Kwan-Yong;Gwon, Jong-Won;Odgelral, Odgelral;Kim, Hie-Sik
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2005년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.279-282
    • /
    • 2005
  • A real-time measurement and control system was developed, This system is used for nurses at hospitals to check the residual quantity and changing time of Ringer's solution in nurses' room. Load Cell is utilized as a sensor to check the residual quantity of Ringer's solution, This Load Cell detects the physical changes of Ringer's solution and transfers electronic signal to the amplifier. Amplified analog signal is converted into digital signal by NO converter. Developed Embedded system, which computes these data with microprocess(8052) then makes it possible to monitor the residual quantity of Ringer's solution real-time on a server computer. A Checking system on Residual Quantity of Ringer's Solution Using Load cell cut costs using a simple design for a circuit

  • PDF

Ringer's solution detector and transceiver design for efficient manage of patient (효율적인 환자관리를 위한 링거액 감지기 및 송수신기 설계)

  • Song, Je-Ho;Lee, In-Sang;Lee, You-Yub
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제17권9호
    • /
    • pp.45-50
    • /
    • 2016
  • This paper reports a Ringer's solution detector and transceiver design for the efficient management of patients. The ringer's solution detection and transceiver consisted of the main control part, ringer's solution detection part, display and warning light part, wireless transceiver, and power supply part. The light receiving part of the ringer's solution detection part employed TSL260R-LF photodiode; light permeating part, Water-Clear type LED; and wireless transceiver part, the RF wireless data transceiver module, NR-FPCX. As a result of this Ringer's solution detector and transceiver design that can manage the patient efficiently, it was found that when the ringer's solution was detected by the double photodiode, the operating frequency was 11.95kHz; when it was not detected, the number was 9.6kHz. In the ringer's solution receiver, when the ringer's solution was detected, the number was 0. The corresponding unique RF code was displayed when not detected. The power used in the ringer's solution detection part was converted to the Sleep mode to operate under battery save mode. The ringer's solution transceiver can exchange wireless communication approximately within a 700m radius.

Effect of Chelated Organic Minerals Liquid Fertilizer on Growth and Fruit Quality in 'Jukhyang' Strawberry (킬레이트 유기 미네랄 액비가 '죽향' 딸기의 생육 및 과실품질에 미치는 영향)

  • Noh, Hye-Ji;Chae, Hyo-Seok;Cho, Hyang-Hyun;Lee, Cheol-Gyu
    • Korean Journal of Organic Agriculture
    • /
    • 제25권4호
    • /
    • pp.725-736
    • /
    • 2017
  • TThis study investigated the influence of AGH-Ringer (chelated organic minerals liquid fertilizer) on the growth, yield, and fruit quality of 'Jukhyang' strawberry in a hydroponic system. The results revealed that AGH-Ringer group led to significantly higher plant length than that of the control group, and that leaf length and leaf width increased with increasing leaf area. In addition, the fresh and dry weights of leaves and SPAD unit, which measures leaf color also showed a significant increase with AGH-Ringer. However, the length and dry weight of roots did not show significant differences when compared to the control group. In the fruit quality analysis, AGH-Ringer group did not show any difference in fruit length compared to the control group, but it increased both the fruit weight, which, along with the simultaneous increase in fruit width, increased the yield per strawberry. Furthermore, AGH-Ringer group strengthened the red skin color of the fruit, and resulted in significantly greater hardness than that of the control group, but did not have any effect on the soluble solid content and acidity. As shown in the results, the AGH-Ringer group resulted in lesser mineral content and lower to medium EC (electrical conductivity) in comparison to the inorganic mineral hydroponic fertilizer, which was used as a control. However, it increased the leaf growth, fruit weight, and yield, and improved the fruit quality by increasing the soluble solid content in the hydroponic system of 'Jukhyang' strawberry. Therefore, based on this study, AGH-Ringer is thought to be a more effective hydroponic fertilizer than the inorganic mineral hydroponic fertilizer. Moreover, the field experiment demonstrated that AGH-Ringer is a useful hydroponic fertilizer convenient for application in farms. This study also proved that AGH-Ringer is a fertilizer that can promote plant nutrition by controlling the salinity of the soil and facilitating the absorption of necessary minerals in future soil cultivation, thereby providing basic data for organic farming.

Irrigation Solutions in the Knee Arthroscopy - Comparison with Normal Saline and Lactated Ringer's Solution (슬관절 관절경 수술시 세척액 - 생리 식염수와 Lactated Ringer 용액의 비교)

  • Lee, Woo-Suk;Bae, In-Tak;Hur, Yun-Moo;Park, Won-Ki;Oh, Byung-Hak;Chung, Whan-Yong
    • Journal of the Korean Arthroscopy Society
    • /
    • 제12권2호
    • /
    • pp.125-128
    • /
    • 2008
  • Purpose: The object of this study is to compare the clinical results of noraml saline and Lactated Ringer's solution in the arthroscopic meniscus surgery on the knee. Materials and Methods: The study group included 64 patients who had an medial meniscus tear and received arthroscopic partial medial meniscectomy. The group I was normal saline group, which was used as an irrigation solution during operation. The group II was Lactated Ringer's solution group. We measured the visual analogue scale, painless active knee flexion angle, and the ratio of the knee swelling at postoperative one day for all patients. Results: The visual analogue scale and the painless active knee flexion angle were no significant differences in comparing with normal saline and Lactated Ringer's solution group. The ratio of the knee swelling in Lactated Ringer's solution group was significantly less than those of noraml saline group. Conclusion: Lactated Ringer's solution has an advantage of decreasing the knee swelling in the arthroscopic meniscus surgery on the knee.

  • PDF

An Algorithm for Detecting Residual Quantity of Ringer's Solution for Automatic Replacement (링거 자동 교체를 위한 잔량 검출 알고리즘)

  • Kim, Chang-Wook;Woo, Sang-Hyo;Zia, Mohy Ud Din;Won, Chul-Ho;Hong, Jae-Pyo;Cho, Jin-Ho
    • Journal of Korea Society of Industrial Information Systems
    • /
    • 제13권1호
    • /
    • pp.30-36
    • /
    • 2008
  • Recently, ere are many researches to improve the quality of e medical service such as Point of care (POC). To improve the quality of the medical service, not only good medical device but also more man power is required. Especially, the number of nurses are very few in Korea that is almost the lowest rank compared to OECD countries. If the simple repetition works of the nurse could be removed, it is possible to use the skillful nurse for other works and provide better quality services. There are many simple repetition works which the nurses have to do, such as replacing the ringer's solution. To replace the ringer's solution automatically, it is necessary to detect residual quantity of the ringer's solution. In this paper, image processing is used to detect the residual quantity of ringer's solution, and modified self quotient image (SQI) algorithm is used to strong background lights. After modified SQI algorithm, the simple histogram accumulation is done to find the residual quantity of the ringer's solution. The implemented algorithm could be use to replace the ringer's solution automatically or alarm to the nurses to replace the solution.

  • PDF

Design and Implementation of Non-contact IoT Ringer Replacement Automatic Notification System (비접촉 IoT 링거 교체 자동 알림 시스템 설계 및 구현)

  • Lee, Hyo-Seung;Oh, Jae-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • 제13권6호
    • /
    • pp.1405-1410
    • /
    • 2018
  • The Ringer's Solution used in medical institutions is one of the injections helpful for recovering the body condition from fever or dehydration by supplying the water to the body. The medical staffs frequently check the amount of Ringer's Solution prescribed for the relevant patient to check the time for replacing the Ringer's Solution. However, currently, many nurses experience the excessive workload because of the insufficient workforce and lots of workload assigned to each of the nurses; so the they cannot provide the high-quality medical services to patients and guardians. In order to solve this problem, this thesis designed and realized the Ringer's Solution replacement time control system through the non-contacting sensor, IoT device using WiFi, and OCS interlock. Thus, this study is expected to be able to efficiently operate the Ringer's Solution replacement work and also to provide the high-quality medical service to patients and guardians by automatically notifying the timing of Ringer's Solution replacement to medical staffs, and omitting the inefficient intermediate step in the past.

Implementation of apparatus for detecting Ringer's solution exhaustion using electrostatic capacitance variation (정전용량변화를 이용한 링거액소진감지장치의 구현)

  • Kim, Cheong-Worl
    • Journal of Sensor Science and Technology
    • /
    • 제19권1호
    • /
    • pp.1-7
    • /
    • 2010
  • Electrostatic capacitance measurement method in a fine hose was proposed, in which two ring-type electrodes were disposed on the hose in the direction of fluid flow instead of the conventional face-to-face electrodes. With the proposed electrode structure, we realized a Ringer's solution exhaustion detector for an IV(invasive vein) injection set. On a 4 mm-diameter hose of IV set, we disposed two ring-type electrodes of 10 mm width at a distance of 5 mm each other and obtained 0.72 pF and 2.51 pF for air and 10 % dextrose Ringer's solution in the hose, respectively. The capacitance between the two electrodes varied with the hose-wraparound coverage of electrode as well as the width of electrode and the distance between the electrodes. For hose-wraparound electrode coverage of 75 %, the capacitance varied from 0.62 pF to 1.98 pF with the Ringer's solution level between the two electrodes. A charge amplifier converted the capacitance. variation into electric signal and a comparator was used to detect whether Ringer's solution was exhausted or not. The result was delivered to a host using a RF transmitter with 320 MHz carrier frequency.