• Title/Summary/Keyword: Ring Finger

Search Result 138, Processing Time 0.032 seconds

Cloning and Expression Analysis of a Novel Mouse Zinc Finger Protein Gene Znf313 Abundantly Expressed in Testis

  • Li, Na;Sun, Huaqin;Wu, Qiaqing;Tao, Dachang;Zhang, Sizhong;Ma, Yongxin
    • BMB Reports
    • /
    • 제40권2호
    • /
    • pp.270-276
    • /
    • 2007
  • We have cloned a novel mouse zinc finger protein gene Znf313 by rapid amplification of cDNA ends (RACE) according to the homologue of human ZNF313 gene. The cDNA is 2,163 base pairs (bp) in length and encodes a 229 amino acids (aa) protein with a $C_3HC_4$ ring finger domain and three $C_2H_2$ domains. 89% and 93% nucleotide (nt) and aa sequence identity is observed with its human homologue. Revealed by Northern blot and RT-PCR, full mRNA consists of 2.16 kb and widely expresses in tissues as a single transcript, most abundantly in heart, liver, kidney and testis. The expression of Znf313 in testis is detected in all development stages. Western blot analysis also reveals that Znf313 is expressed in the tissues. Immunohistochemical staining and subcellular localization demonstrate that Znf313 is expressed both in the cytoplasm and nucleus whereas predominantly localized in the nucleus. Present data suggests that Znf313 gene might play a fundamental role in gene transcription and regulation in organism and relates to spermatogenesis.

원통형 물체 쥐기 시 건강한 성인과 척수마비 환자의 최대 손가락 끝 힘 분포 비교 (Comparison of Maximum Fingertip Force Distribution in Cylindrical Grasping Between Healthy Adults and Patients With Spinal Cord Injury)

  • 황지선;이재선;황선홍
    • 한국전문물리치료학회지
    • /
    • 제29권1호
    • /
    • pp.28-36
    • /
    • 2022
  • Background: It is known that hand strength and fingertip force are used as an indicator of muscle strength and are also highly related to the various chronic symptoms and even lifespan. To use the individual fingertip force (IFF) as a quantitative index for clinical evaluation, the IFF should be measured and analyzed with various variables from various subjects, such as the normal range of fingertip force and the difference in its distribution by disease. Objects: We tried to measure and analyze the mean maximum IFF distribution during grasping a cylindrical object in healthy adults and patients with spinal cord injury (SCI). Methods: Five Force-sensitive resistor (FSR) sensors were attached to the fingertips of 24 healthy people and 13 patients with SCI. They were asked to grip the object three times for five seconds with their maximum effort. Results: The mean maximum IFF of the healthy adult group's thumb, index, and middle finger was similar statistically and showed relatively larger than IFF of the ring and small finger. It is a 3-point pinch grip pattern. All fingertip forces of patients with SCI decreased by more than 50% to the healthy group, and their IFF of the middle finger was relatively the largest among the five fingertip forces. The cervical level injured SCI patients showed significantly decreased IFFs compared to thoracic level injured SCI patients. Conclusion: We expect that this study results would be helpful for rehabilitation diagnosis and therapy goal decision with robust further study.

머신러닝과 3D 프린팅을 이용한 저비용 인공의수 모형 (Low-cost Prosthetic Hand Model using Machine Learning and 3D Printing)

  • 신동욱;염호준;박상수
    • 문화기술의 융합
    • /
    • 제10권1호
    • /
    • pp.19-23
    • /
    • 2024
  • 양손 절단 환자들에게 미용적 목적과 함께 기능적 목적을 갖춘 의수가 필요하며 잔존 근육의 근전도를 이용한 인공 의수에 대한 연구가 활발하나 아직도 비싼 비용의 문제가 있다. 본 연구에서는 저비용의 부품과 소프트웨어인 표면 근전도 센서, 머신러닝 소프트웨어 Edge Impulse, Arduino Nano 33 BLE, 그리고 3D 프린팅을 이용하여 인공의수를 제작하고 성능을 평가하였다. 표면 근전도 센서로 획득하고 Edge Impulse에서 디지털 시그널 프로세싱 과정을 거친 신호들을 이용하여 머신러닝으로 손가락 운동의 종류를 판단하는 훈련을 통해 각 손가락의 굽힘 운동신호를 의수 모델의 손가락들에 전달하였다. 디지털 시그널 프로세싱 조건을 노치 필터 60 Hz, 대역필터 10-300 Hz, 그리고 샘플링 주파수 1,000 Hz로 했을 때, 머신 러닝의 정확도가 82.1%로 가장 높았다. 각 손가락 굴곡 운동간에 혼동될 수 있는 가능성은 약지가 가장 높아서 검지의 운동으로 혼동될 가능성이 44.7 %이었다. 저비용 인공의수의 성공적인 개발을 위해서는 더 많은 연구가 필요하다.

컴퓨터의 보안향상을 위한 상호정전용량 터치스크린패널의 차동펄스를 이용한 지문인식을 위한 송신법 (The Transmit Method for Fingerprint sensing using Differential Pulse in Mutual Capacitance Touch Screen Panel for improving security of computer information)

  • 김성문;최은호;고낙영;변영재
    • 전자공학회논문지
    • /
    • 제54권7호
    • /
    • pp.55-60
    • /
    • 2017
  • 본 논문은 컴퓨터의 보안향상을 위한 차동펄스를 이용하여 상호정전용양 터치스크린 패널의 지문인식 송신법을 제안한다. 차동펄스생성기와 Ring-Counter로 구성되어 있으며, 공급전압은 5V이다. 제안된 시스템의 출력파형은 In-Phase 와 Out of Phase의 구성되었으며, 2ms의 동안에 1MHz가 포함된 펄스를 출력한다. 4개의 채널을 구동할 수 있는 구조로 설계되었으며 전체 전력소모량은 약 78.08nW 이다. 본 시스템은 TSMC 0.25um CMOS 공정으로 설계 되었고, Chip Area는 $870um{\times}880um$이다.

Schizosaccharomyces pombe rsml Genetically Interacts with spmex67, Which Is Involved in mRNA Export

  • Yoon, Jin-Ho
    • Journal of Microbiology
    • /
    • 제42권1호
    • /
    • pp.32-36
    • /
    • 2004
  • We have previously isolated three synthetic lethal mutants from Schizosaccharomyces pombe in order to identify mutations in the genes that are functionally linked to spmex67 with respect to mRNA export. A novel rsm1 gene was isolated by complementation of the growth defect in one of the synthetic lethal mutants, SLMex1. The rsml gene contains no introns and encodes a 296 amino-add-long protein with the RING finger domain, a C3HC4 in the N-terminal half. The Δrsm1 null mutant is viable, but it showed a slight poly(A)$\^$+/ RNA accumulation in the nucleus. Also, the combination of Δrsm1 and Δspmex67 mutations confers synthetic lethality that is accompanied by the severe poly(A)$\^$+/ RNA export defect. These results suggest that rsm1 is involved in mRNA export from the nucleus.

RFID tag 집적화를 위한 $0.18{\mu}m$ 표준 CMOS 공정을 이용한 쇼트키 다이오드의 제작 (Fabrication of Schottky diodes for RFID tag integration using Standard $0.18{\mu}m$ CMOS process)

  • 심동식;민영훈
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2006년도 하계종합학술대회
    • /
    • pp.591-592
    • /
    • 2006
  • Schottky diodes for Radio-frequency identification (RFID) tag integration on chip were designed and fabricated using Samsung electronics System LSI standard $0.18{\mu}m$ CMOS process. Schottky diodes were designed as interdigitated fingers array by CMOS layout design rule. 64 types of Schottky diode were designed and fabricated with the variation of finger width, length and numbers with a $0.6{\mu}m$ guard ring enclosing n-well. Titanium was used as Schottky contact metal to lower the Schottky barrier height. Barrier height of the fabricated Schottky diode was 0.57eV. DC current - voltage measurements showed that the fabricated Schottky diode had a good rectifying properties with a breakdown voltage of -9.15 V and a threshold voltage of 0.25 V.

  • PDF

The Onset and Duration of Action of 0.2% Lidocaine in a One-per-Mil Tumescent Solution for Hand Surgery

  • Prasetyono, Theddeus O.H.;Lestari, Puri A.
    • Archives of Plastic Surgery
    • /
    • 제43권3호
    • /
    • pp.272-277
    • /
    • 2016
  • Background One-per-mil tumescent solution, which contains 0.2% lidocaine with 1:1,000,000 epinephrine, has been reported to be clinically effective for hand surgery under local anesthesia. However, it was lacking in its basic pharmacokinetics profile in regard to the onset of action (OOA) and duration of action (DOA). Methods A randomized, double-blind study was conducted on 12 volunteers who met the inclusion criteria from October to November 2014. All volunteers had their right and left ring finger pulps injected with either one-per-mil solution or 2% lidocaine. Semmes-Weinstein and two-point discrimination tests were used to test sensation. Visual analogue scale was recorded at the time when the finger lost its sensation and when it regained normal sensation to measure the OOA and DOA. The data were then analyzed with a paired t-test and a Wilcoxon signed-rank test. Results The OOA and DOA of 2% plain lidocaine were 1 minute and 99.67 minutes, respectively. Meanwhile, 0.2% lidocaine in a one-per-mil tumescent solution showed an OOA of 5 minutes and a DOA of 186.83 minutes. The OOA of 0.2% lidocaine in a one-per-mil tumescent solution is statistically shorter than 2% plain lidocaine (P=0.04); while its DOA is statistically longer than 2% plain lidocaine (P<0.001). Conclusions The 0.2% lidocaine in a one-per-mil tumescent solution is statistically and clinically superior to 2% plain lidocaine in achieving longer duration of local anesthesia.

손가락 길이 비율과 남녀 체형과의 상관성 (Second to Fourth Digit Ratio and Sexually Dimorphic Body Composition)

  • 박정현;송미영;김호준;이명종
    • 한방비만학회지
    • /
    • 제10권1호
    • /
    • pp.41-48
    • /
    • 2010
  • Background The length of the second digit (the index finger) relative to the length of the fourth digit (the ring finger) is sexually dimorphic as males have a lower second to fourth digit ratio (2D:4D). There is evidence that sex differences in 2D:4D arise from in utero concentrations of sex steroids, with a low 2D:4D (male typical ratio) being positively related to prenatal testosterone, while a high 2D:4D (female typical ratio) is positively associated with prenatal oestrogen Objective To investigate possible associations between 2D:4D ratio and sexually dimorphic body composition Methods 2D:4D ratio, body mass index (BMI), waist circumference, waist-hip ratio (WHR), weight, and body fat percentage was measured from 46 men and 20 women Results Digit ratio was found to be significantly lower in men than in women. No significant correlation between 2D:4D ratio and body compositions was found for both men and women while digit ratio in obese men was significantly higher than normal weight men. Conclusion This finding dose not support the significant correlation between digit ratio and sexually dimorphic body composition. However digit ratio in obese men was significantly higher than normal weight men.

Development of the Caliper System for a Geometry PIG Based on Magnetic Field Analysis

  • Kim, Dong-Kyu;Cho, Sung-Ho;Park, Seoung-Soo;Yoo, Hui-Ryong;Park, Yong-Woo;Kho, Young-Tai;Park, Gwan-Soo;Park, Sang-Ho
    • Journal of Mechanical Science and Technology
    • /
    • 제17권12호
    • /
    • pp.1835-1843
    • /
    • 2003
  • This paper introduces the development of the caliper system for a geometry PIG (Pipeline Inspection Gauge). The objective of the caliper system is to detect and measure dents, wrinkles, and ovalities affect the pipe structural integrity. The developed caliper system consists of a finger arm, an anisotropic permanent magnet, a back yoke, pins, pinholes and a linear hall effect sensor. The angle displacement of the finger arm is measured by the change of the magnetic field in sensing module. Therefore the sensitivity of the caliper system mainly depends on the magnitude of the magnetic field inside the sensing module. In this research, the ring shaped anisotropic permanent magnet and linear hall effect sensors were used to produce and measure the magnetic field. The structure of the permanent magnet, the back yoke and pinhole positions were optimized that the magnitude of the magnetic field range between a high of 0.1020 Tesla and a low of zero by using three dimensional nonlinear finite element methods. A simulator was fabricated to prove the effectiveness of the developed caliper system and the computational scheme using the finite element method. The experimental results show that the developed caliper system is quite efficient for the geometry PIG with good performance.

체감각 자극치료가 뇌졸중 환자의 감각, 상지 기능 및 자아존중감의 변화에 미치는 영향 (Effects of Somatosensory Stimulation Therapy on Upper Limb Sensory and Function and Self-Esteem of Stroke Patients)

  • 이지웅;최원호
    • 대한통합의학회지
    • /
    • 제8권1호
    • /
    • pp.87-99
    • /
    • 2020
  • Purpose : This study aims to investigate the effect of somatosensory stimulation on the upper limb sensory and function and self-esteem of stroke patients. Methods : This study period was march 4 to april 4 (5 weeks). The subject were 20 stroke patients with somatosensory impairment in B hospital, seongnam, gyeonggi province. They were devided into two group-experimental and control-with 10 members each. The members of the experimental group underwent somatosensory stimulation, whereas the members of the control group underwent an occupation-based intervention for 5 weeks. Thirty-minute therapy was provided 3 times per week for 5 weeks. Before and after the intervention, both groups were evaluated via light touch, static two-point discrimination, stereognosis, Fugl-Meyer assessment (FMA), and self-esteem scale Results : In this study, light touch was not significant in both groups. Static two-point discrimination was significant among the experimental group member's index fingers. Among the control group members, it was significant in the ring finger. The comparison between the two groups was significant in the index finger. The stereognosis results were significant in the experimental group but not in the control group. The comparison between the groups after the intervention was not significant. FMA was significant in the shoulder/ elbow/ forearm (SEF), hand and coordination among the experimental group. Among the control group, it was significant in the SEF and hand. The comparison between the groups was significant in the SEF, hand and coordination. The self-esteem scale results were significant among both groups, and the comparison between the group's score was likewise significant. Conclusion : In conclusion, somatosensory stimulation therapy increases the static two-point discrimination, stereognosis, upper extremity function, and self-esteem of patients with stroke. Therefore, while somatosensory stimulation therapy is not the best therapy, it is one of the best occupational therapies for stroke patients.