• Title/Summary/Keyword: Return Current Path

Search Result 37, Processing Time 0.039 seconds

Study on the Effect of Parallel Ground Conductor at the Single Point Bonding in Underground Transmission System (지중송전 편단접지개소에서의 병행지선 설치효과 검토)

  • Kang, J.W.;Park, H.S.;Yoon, H.H.;Yoon, J.K.;Bae, J.H.;Suk, K.H.;Oh, J.M.;Kim, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.736-737
    • /
    • 2007
  • The single point bonding in underground transmission system can induce high voltage on the sheath when ground fault, lightning serge and switching serge occurs, at that time underground cable systems cannot offer a return path of fault current. Accordingly if fault current, which cannot return to ground, flows at the single point bonding, high voltage can be induced in SVL and that voltage can cause aging and breakdown of SVL. Therefore this paper study on the effect of parallel ground conductor at the single point bonding when ground fault and lightning serge occurs by using ATPDraw.

  • PDF

Domestic Conditions on the Electrolytic Corrosion Protection of Buried Metallic Structures (지하매설 금속구조물의 전식방지 국내 현황)

  • Lee, Hyun-Goo;Ha, Tae-Hyun;Choi, Jeong-Hee;Jung, Ho-Sung;Bae, Jeong-Hyo
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.2
    • /
    • pp.1-6
    • /
    • 2009
  • With respect to a given structure, a stray current is to be defined as a current flowing on a structure that is not part of the intended electrical circuit. Most often DC-powered traction systems like railroads and tramlines are responsible for large dynamic stray currents. This type of stray current is generally results from the leakage of return currents from large DC traction systems that are grounded or have a bad earth-insulated return path. At the place where the current leaves the rail and metallic structures, electrolytic corrosion may take place. This paper investigates the domestic conditions on the electrolytic corrosion protection of buried metallic structures adjacent to DC traction systems by survey.

  • PDF

Modulated Carrier Control for Interleaved Continuous Conduction Mode(CCM) Boost Power Factor Correction Converter

  • Kim, Hye-jin;Choi, Kyu-sik;Cho, B.H.;Choi, Hang-seok
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.195-196
    • /
    • 2012
  • In recent years, in an effort to improve the efficiency and the power density of the front-end power factor correction(PFC), the interleaving of multiple converter is employed. The conventional interleaved continuous conduction mode(CCM) boost PFC converter requires input and output voltage sensing and three current sensing to obtain current balancing between modules. In this paper, the interleaved CCM PFC converter based on modulated carrier control is proposed. With the proposed method, two phase interleaved PFC can be realized simply without line voltage sensing resistor and can achieve current balancing without additional current sensing resistor on common return path. The simulation studies are carried out to verify the effectiveness of the proposed control scheme.

  • PDF

The Protection methods of Telecommunication Network from Electrical Transient Phenomena (전기적 과도현상으로부터 통신망의 보호대책)

  • Choi, Man-Ho;Kim, Hyun-Duk;Kim, Byung-Cheul
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.2
    • /
    • pp.693-696
    • /
    • 2005
  • Parallel and cross of the electrical power and telecommunication network is become accelerated, because telecommunication equipments are constructed according to road for efficient maintenance of domestic telecommunication network. The electrical power network can generate an electrostatic induction, and is itself transmission medium from electrical transient phenomenon such as lighting. So, transient phenomenon of lightning surge is induced to telecommunication network, and then it is damaged by connecting between electrical ground of electrical power network and telecommunication network. In this study, we found that cut-off of return path current by separate distance between electrical ground of electrical power network and telecommunication network, and cut-off of electrostatic induction voltage by grounding unused leads of both terminals of the electrical and telecommunication network have good effect as the protection methods of telecommunications network from electrical transient phenomena.

  • PDF

DC Motor Drive with Circuit Balancing Technique to Reduce Common Mode Conducted Noise

  • Jintanamaneerat, Jintanai;Srisawang, Arnon;Prempraneerach, Yothin
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1881-1884
    • /
    • 2003
  • In some requirements of dc motor drive circuit applications are high quality output with generation of low internal conducted EMI. However the conventional dc motor drive circuits have been usually using unbalanced circuit which generates the high conducted EMI to the frame ground. This paper presents a balanced dc motor drive circuit which is effective way to reduce the common-mode noise. The circuit balancing is to make the noise pick up or occurring in both conductor lines, signal path and return path is equal in amplitude and opposite phase so that it will cancel out in the frame ground. The common-mode conducted noise reduction of this proposed dc motor drive is confirmed by experimental results.

  • PDF

Sheath Circulating Current Analysis of a Crossbonded Power Cable Systems

  • Jung, Chae-Kyun;Lee, Jong-Beom;Kang, Ji-Won
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.3
    • /
    • pp.320-328
    • /
    • 2007
  • The sheath in underground power cables serves as a layer to prevent moisture ingress into the insulation layer and provide a path for earth return current. Nowadays, owing to the maturity of manufacturing technologies, there are normally no problems for the quality of the sheath itself. However, after the cable is laid in the cable tunnel and is operating as part of the transmission network, due to network construction and some unexpected factors, some problems may be caused to the sheath. One of them is the high sheath circulating current. In a power cable system, the uniform configuration of the cables between sections is sometimes difficult to achieve because of the geometrical limitation. This will cause the increase of sheath circulating current, which results in the increase of sheath loss and the decrease of permissible current. This paper will study the various characteristics and effects of sheath circulating current, and then will prove why the sheath current rises on the underground power cable system. A newly designed device known as the Power Cable Current Analyser, as well as ATP simulation and calculation equation are used for this analysis.

A Broadband Digital Step Attenuator with Low Phase Error and Low Insertion Loss in 0.18-${\mu}m$ SOI CMOS Technology

  • Cho, Moon-Kyu;Kim, Jeong-Geun;Baek, Donghyun
    • ETRI Journal
    • /
    • v.35 no.4
    • /
    • pp.638-643
    • /
    • 2013
  • This paper presents a 5-bit digital step attenuator (DSA) using a commercial 0.18-${\mu}m$ silicon-on-insulator (SOI) process for the wideband phased array antenna. Both low insertion loss and low root mean square (RMS) phase error and amplitude error are achieved employing two attenuation topologies of the switched path attenuator and the switched T-type attenuator. The attenuation coverage of 31 dB with a least significant bit of 1 dB is achieved at DC to 20 GHz. The RMS phase error and amplitude error are less than $2.5^{\circ}$ and less than 0.5 dB, respectively. The measured insertion loss of the reference state is less than 5.5 dB at 10 GHz. The input return loss and output return loss are each less than 12 dB at DC to 20 GHz. The current consumption is nearly zero with a voltage supply of 1.8 V. The chip size is $0.93mm{\times}0.68mm$, including pads. To the best of the authors' knowledge, this is the first demonstration of a low phase error DC-to-20-GHz SOI DSA.

EMI Reduction Analysis by a Conductor between Frames (프레임을 연결하는 전도체의 구조가 EMI 감소에 미치는 영향 분석)

  • Koh, Eun-Kwang;Shim, Min-Kyu;Hong, Eun-Ju;Lee, Jai-Yeol;Park, Seung-Hun;Kwak, In-Gu;Nah, Wan-Soo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.2
    • /
    • pp.263-270
    • /
    • 2008
  • In this paper, we investigated EMI(electromagnetic interference) reduction by conductor connection, which was used for fixing and electrical grounding between frames. Conductor connects two frames and then it provides the decrease of return path of signal current. To prove the effect of conductor, we measured/simulated the RE(radiated emission) with/without conductors between the two frames. From the measured/simulated results, we observed that EMI decreased about 1$\sim$10 dB at the frequency range of 30 MHz to 1 GHz. VNA(vector network analyzer) was used to measure the S parameters and the RE was measured in a 3 m anechoic chamber. The simulated and measured results are compared and discussed.

A Study on the Desin of Microstrip Antenna for Mobile System (Mobile 시스템을 위한 마이크로스트립 안테나 설계에 관한 연구)

  • 고영혁;이종악
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.4 no.2
    • /
    • pp.34-40
    • /
    • 1993
  • A microstrip antenna for mobile system are designed at the resont frequency 0.88 GHz. The microstrip array antenna are designed to depend on the size of rectanular microstrip path for the relative current distribution to be 1:4.69:1 using Tchebyscheff polynominals. Gain difference between the main lobe and sidelobe is calculated for theoritical values of 20 dB. The designed microstrip array antenna are mesureed various characteristics, such as return loss, radiation pattern, V.S.W.R, bandwidth, and agreed with each other and theoretical value. Also it is presented a process of phase variation of patch array antenna depend on relative current distribution for beam scanning.

  • PDF