• Title/Summary/Keyword: Response time analysis

Search Result 4,034, Processing Time 0.034 seconds

Time Domain Soil-Structure Interaction Analysis for Earthquake Loadings Based on Analytical Frequency-Dependent Infinite Elements (무한요소를 사용한 지반-구조물 상호작용계의 시간 영역 지진응답해석)

  • 김두기
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1999.10a
    • /
    • pp.107-112
    • /
    • 1999
  • This paper presents a time domain method for soil-structure interaction analysis for seismic loadings. It is based on the finite element formulation incorporating analytical frequency-dependent infinite elements for the far-field soil. The dynamic stiffness matrices of the far-field region formulated in frequency domain using the present method can be easily transformed into the corresponding matrices in time domain. Hence the response can be analytical computed in time domain. Example analysis has been carried out to verify the present method for an embedded block in a multi-layered half-space. The present methods can be easily extended to the nonlinear analysis since the response analysis is carried out in time domain.

  • PDF

In-Cabinet Response Spectrum Generation Using Frequency Domain Analysis Method (진동수영역해석법을 이용한 캐비닛내부응답스펙트럼 생성 기법)

  • Cho, Sung Gook;So, Gihwan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.24 no.2
    • /
    • pp.103-110
    • /
    • 2020
  • Seismic qualification of instruments and devices mounted on electrical cabinets in a nuclear power plant is performed in this study by means of the in-cabinet response spectrum (ICRS). A simple method and two rigorous methods are proposed in the EPRI NP-7146-SL guidelines for generating the ICRS. The simple method of EPRI can give unrealistic spectra that are excessively conservative in many cases. In the past, the time domain analysis (TDA) methods have been mostly used to analyze a structure. However, the TDA requires the generation of an artificial earthquake input motion compatible to the target response spectrum. The process of generating an artificial earthquake may involve a great deal of uncertainty. In addition, many time history analyses should be performed to increase the accuracy of the results. This study developed a numerical analysis program for generating the ICRS by frequency domain analysis (FDA) method. The developed program was validated by the numerical study. The ICRS calculated by FDA thoroughly matched with those obtained from TDA. This study then confirms that the method it proposes can simply and efficiently generate the ICRS compared to the time domain method.

KBC Seismic Design Force for Nonstructural Element (KBC 비구조요소 내진설계 하중)

  • Kim, Dae-Kon
    • Journal of Korean Association for Spatial Structures
    • /
    • v.14 no.1
    • /
    • pp.77-84
    • /
    • 2014
  • Simple 3, 10, and 30-story buildings with a nonstructural element which is located at roof or near the middle of the building height are selected. Based on 2009 Korean Building Code, the seismic design force applied at the nonstructural element is evaluated. Response spectrum analysis is conducted with the design response acceleration spectrum of 2009 Korean Building Code and the analytical response is compared with the seismic design force from the Code. Furthermore, an artificial earthquake based on Korean design response acceleration spectrum and the 50% intensity of El Centro earthquake, which can be considered as the maximum future earthquake possibly occurring in Korea, are selected to conduct time history analysis. When the period of the nonstructural element is shorter than 0.06 second or longer than that of the 1st period of each building, the Code equations of seismic design force for nonstructural element seems to be appropriate. However, the period of the nonstructural element is close to the one of the building's higher mode periods including the 1st period, seismic force of the nonstructural element might exceed the Code specified seismic design force.

Applicability of Beam Model among Earthquake Response Analysis Models of Liquid-Storage Tank (액체저장탱크의 지진응답해석 모델 중 빔 모델의 적용성)

  • Jin, Byeong-Moo;Jeon, Se-Jin;Kim, Young-Jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.696-699
    • /
    • 2004
  • Generally, the time history analysis among seismic response analyses of a structure needs more times than static analysis. Therefore the mechanical model of a structure has been used as a simple lumped parameter model in time history analysis. For the most cases, the simple mechanical model shows the similar results to that of detailed finite element model. so it is reasonable to use the simple mode] in preliminary analysis. In seismic design of liquid storage tank, such as LNG storage tank, the lumped parameter mode] also is being used in preliminary analysis, however sometimes shows the differences to the results of detailed finite element model. Therefore in this study, the dynamic characteristics between lumped parameter model and detailed finite model is compared for the variables such as height/diameter of liquid-storage tank and thickness of wall, then the applicability of beam mode] to the seismic response analysis are evaluated for some liquid storage tanks.

  • PDF

Application of frequency domain analysis for generation of seismic floor response spectra

  • Ghosh, A.K.
    • Structural Engineering and Mechanics
    • /
    • v.10 no.1
    • /
    • pp.17-26
    • /
    • 2000
  • This paper presents a case study with a multi-degree-of-freedom (MDOF) system where the Floor Response Spectra (FRS) have been derived from a large ensemble of ground motion accelerograms. The FRS are evaluated by the frequency response function which is calculated numerically. The advantage of this scheme over a repetitive time-history analysis of the entire structure for each accelerogram of the set has been highlighted. The present procedure permits generation of FRS with a specified probability of exceedence.

Holistic Scheduling Analysis of a CAN based Body Network System (CAN을 이용한 차체 네트웍 시스템에 대한 Holistic 스케줄링 해석)

  • 신민석;이우택;선우명호
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.5
    • /
    • pp.114-120
    • /
    • 2002
  • In a distributed real-time control system, it is essential to confirm the timing behavior of all tasks because these tasks of each real-time controller have to finish their processes within the specified time intervals called a deadline. In order to satisfy this objective, the timing analysis of a distributed real-time system such as shcedulability test must be performed during the system design phase. In this study, a simple application of CAN fur a vehicle body network system is formulated to apply to a holistic scheduling analysis, and the worst-case execution time (WCET) and the worst-case end-to-end response time (WCRT) are evaluated in the point of holistic system view.

Earthquake Response Analysis for Seismic Isolation System of Single Layer Lattice Domes With 300m Span (300m 단층 래티스 돔의 면진 장치에 대한 지진 반응 해석)

  • Park, Kang-Geun;Chung, Mi-Ja;Lee, Dong-Woo
    • Journal of Korean Association for Spatial Structures
    • /
    • v.18 no.3
    • /
    • pp.105-116
    • /
    • 2018
  • The objective of this study is to investigate the response reducing effect of a seismic isolation system installed between 300m dome and supports under both horizontal and vertical seismic ground motion. The time history analysis is performed to investigate the dynamic behavior of single layer lattice domes with and without a lead rubber bearing seismic isolation system. In order to ensure the seismic performance of lattice domes against strong earthquakes, it is important to investigate the mechanical characteristics of dynamic response. Horizontal and vertical seismic ground motions cause a large asymmetric vertical response of large span domes. One of the most effective methods to reduce the dynamic response is to install a seismic isolation system for observing seismic ground motion at the base of the dome. This paper discusses the dynamic response characteristics of 300m single layer lattice domes supported on a lead rubber seismic isolation device under horizontal and vertical seismic ground motions.

Demand Response Program Using the Price Elasticity of Power Demand (전력수요의 가격탄력성을 이용한 수요반응 프로그램)

  • Yurnaidi, Zulfikar;Ku, Jayeol;Kim, Suduk
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.76.1-76.1
    • /
    • 2011
  • With the growing penetration of distributed generation including from renewable sources, smart grid power system is needed to address the reliability problem. One important feature of smart grid is demand response. In order to design a demand response program, it is indispensable to understand how consumer reacts upon the change of electricity price. In this paper, we construct an econometrics model to estimate the hourly price elasticity of demand. This panel model utilizes the hourly load data obtained from KEPCO for the period from year 2005 to 2009. The hourly price elasticity of demand is found to be statistically significant for all the sample under investigation. The samples used for this analysis is from the past historical data under the price structure of three different time zones for each season. The result of the analysis of this time of use pricing structure would allow the policy maker design an appropriate incentive program. This study is important in the sense that it provides a basic research information for designing future demand response programs.

  • PDF

The Multiple Traveling Purchaser Problem for Minimizing Logistics Response Time in Wartime (전시 군수반응시간 최소화를 위한 복수 순회구매자 문제)

  • Choi, Myung-Jin
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.431-437
    • /
    • 2010
  • It's strongly needed to minimize the logistics response time for supporting military operations in wartime. In this paper, we suggest the ILP formulation for minimizing logistics response time in wartime. Main structure of this formulation is based on the traveling purchaser problem(TPP) which is a generalized form of the well-known traveling salesman problem(TSP). In the case of general TPP, objective function is to minimize the sum of traveling cost and purchase cost. But, in this study, objective function is to minimize traveling cost only. That's why it's more important to minimize traveling cost(time or distance) than purchase cost in wartime. We find out optimal solution of this problem by using ILOG OPL STUDIO(CPLEX v.11.1) and do the sensitive analysis about computing time according to number of operated vehicles.

Estimation of Nonlinear Response for Moment Resisting Reinforced Concrete Frames Using Equivalent SDOF System (등가 1 자유도계에 의한 철근콘크리트 건물의 비선형 동적해석의 검토)

  • 전대한;노필성
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.09a
    • /
    • pp.205-212
    • /
    • 2003
  • To evaluate the seismic performance of multistory building structures use an equivalent SDOF model. This paper presents a method of converting a MDOF system into an equivalent SDOF model. The principal objective of this investigation is to evaluate appropriateness of converting method through perform nonlinear time history analysis of a multistory building structures and an equivalent SDOF model. The hysteresis rules to be used an equivalent SDOF model is obtained from the pushover analysis. The conclusion of this study is following; A method of converting a MDOF system into an equivalent SDOF model through the nonlinear time history response analysis is valid. The representative lateral displacement of a moment resisting reinforced concrete frames is close to the height of the first modal participation vector $_1$$\beta$$_1$u}=1. It can be found that the hysteresis rule of an equivalent SDOF model have influence on the time history response. Therefore, it is necessary for selecting hysteresis rules to consider hysteresis characteristics of a moment resisting reinforced concrete frames.

  • PDF