• 제목/요약/키워드: Response loop

검색결과 665건 처리시간 0.031초

Parallel Operation of Microgrid Inverters Based on Adaptive Sliding-Mode and Wireless Load-Sharing Controls

  • Zhang, Qinjin;Liu, Yancheng;Wang, Chuan;Wang, Ning
    • Journal of Power Electronics
    • /
    • 제15권3호
    • /
    • pp.741-752
    • /
    • 2015
  • This study proposes a new solution for the parallel operation of microgrid inverters in terms of circuit topology and control structure. A combined three-phase four-wire inverter composed of three single-phase full-bridge circuits is adopted. Moreover, the control structure is based on adaptive three-order sliding-mode control and wireless load-sharing control. The significant contributions are as follows. 1) Adaptive sliding-mode control performance in inner voltage loop can effectively reject both voltage and load disturbances. 2) Virtual resistive-output-impedance loop is applied in intermediate loop to achieve excellent power-sharing accuracy, and load power can be shared proportionally to the power rating of the inverter when loads are unbalanced or nonlinear. 3) Transient droop terms are added to the conventional power outer loop to improve dynamic response and disturbance rejection performance. Finally, theoretical analysis and test results are presented to validate the effectiveness of the proposed control scheme.

트랙킹 액추에이터의 진동 억제를 위한 트랙킹 Gain-up 제어기 설계 (Design of a Tracking Gain-up Controller for the Vibration Suppression of Tracking Actuator)

  • 이문노;진경복
    • 한국소음진동공학회논문집
    • /
    • 제23권4호
    • /
    • pp.356-364
    • /
    • 2013
  • This paper presents a tracking gain-up controller design method to control effectively the vibration of tracking actuator caused by external shocks and remaining velocity after seek control. A pole placement constraint is considered to assure a desired transient response against the vibration of tracking actuator. A loop gain-up constraint is introduced to hold the tracking gain-up loop gain and control bandwidth within allowable bounds. The pole placement constraint is expressed by a matrix inequality and the loop gain-up constraint is considered as an objective function so that genetic algorithm can be applied. Finally, a tracking gain-up controller is obtained by integrating a genetic algorithm with LMI design approach. The proposed tracking gain-up controller design method is applied to the track-following system of a DVD recording device and its effectiveness is evaluated through the experimental results.

Duty Ratio Predictive Control Scheme for Digital Control of DC-DC Switching Converters

  • Sun, Pengju;Zhou, Luowei
    • Journal of Power Electronics
    • /
    • 제11권2호
    • /
    • pp.156-162
    • /
    • 2011
  • The control loop time delay caused by sampling, the zero-order-holder effect and calculations is inevitable in the digital control of dc-dc switching converters. The time delay will limit the bandwidth of the control loop and therefore degrade the transient performance of digital systems. In this paper, the quantization time delay effects with different time delay values based on a generic second-order system are analyzed. The conclusion that the bandwidth of digital control is reduced by about 20% with a one cycle delay and by 50% with two cycles of delay in comparison with no time delay is obtained. To compensate the time delay and to increase the control loop bandwidth, a duty ratio predictive control scheme based on linear extrapolation is proposed. The compensation effect and a comparison of the load variation transient response characteristics with analogy control, conventional digital control and duty ratio predictive control with different time delay values are performed on a point-of-load Buck converter by simulations and experiments. It is shown that, using the proposed technique, the control loop bandwidth can be increased by 50% for a one cycle delay and 48.2% for two cycles of delay when compared to conventional digital control. Simulations and experimental results prove the validity of the conclusion of the quantization effects of the time delay and the proposed control scheme.

비정현 계통 전압하에서 단상 인버터의 PLL 성능 개선 방법 (A Method to Improve the Performance of Phase-Locked Loop (PLL) for a Single-Phase Inverter Under the Non-Sinusoidal Grid Voltage Conditions)

  • Khan, Reyyan Ahmad;Ashraf, Muhammad Noman;Choi, Woojin
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 추계학술대회
    • /
    • pp.7-8
    • /
    • 2017
  • The Phase-Locked Loop (PLL) is widely used in grid-tie inverter applications to achieve the synchronization between the inverter and the grid. However, its performance is deteriorated when the grid voltage is not pure sinusoidal due to the harmonics and the frequency deviation. Therefore it is important to design a high performance phase-locked loop (PLL) for the single phase inverter applications to guarantee the quality of the inverter output. In this paper a simple method to improve the performance of the PLL for the single phase inverter is proposed. The proposed PLL is able to accurately estimate the fundamental frequency component of the grid voltage even in the presence of harmonic components. In additional its transient response is fast enough to track a change in grid voltage within two cycles of the fundamental frequency. The effectiveness of the proposed PLL is confirmed through the PSIM simulation and experiments.

  • PDF

전원사고 시 3상 계통연계 인버터의 전원 전압 고속 검출 방법 (High Speed Grid Voltage Detection Method for 3 Phase Grid-Connected Inverter during Grid Faults)

  • 최형진;송승호;정승기;최주엽;최익
    • 한국태양에너지학회 논문집
    • /
    • 제29권5호
    • /
    • pp.65-72
    • /
    • 2009
  • The new method is proposed to improve high speed detection of grid voltage phase and magnitude during a voltage dip due to a grid faults. Usually, A LPF(Low Pass Filter) is used in the feedback loop of PLL (Phase Locked Loop) system because the measured grid voltage contains harmonic distortions and sensor noises. so, a new design method of the loop gain of the PI -type controller in the PLL system is proposed with the consideration of the dynamics of the LPF. As a result, a better transient response can be obtained with the proposed design method. The LPF frequency and PI controller gain are designed in coordination according to the steady state and dynamic performance requirement. This paper shows the feasibility and the usefulness of the proposed methods through the computer simulation and the lab-scale experiments.

임의 파형 발생기를 위한 단일 루프 전압 제어기 설계 (Design of the Single-loop Voltage Controller for Arbitrary Waveform Generator)

  • 김현식;지승준;설승기
    • 전력전자학회논문지
    • /
    • 제21권1호
    • /
    • pp.58-64
    • /
    • 2016
  • This study presents a design method for a single-loop voltage controller that is suitable for an arbitrary waveform generator (AWG). The voltage control algorithm of AWG should ensure high dynamic performance and should attain sufficient robustness to disturbances such as inverter nonlinearity, sensor noise, and load current. By analyzing the power circuit of AWG, control limitation and control target are presented to improve the dynamic performance of AWG. The proposed voltage control algorithm is composed of a single-loop output voltage control, an inverter current feedback term to improve transient response, and a load current feedforward term to prevent voltage distortion. The guideline for setting control gain is presented based on output filter parameters and digital time delay. The performance of the proposed algorithm is proven by experimental results through comparison with the conventional algorithm.

Novel Control Method for a Hybrid Active Power Filter with Injection Circuit Using a Hybrid Fuzzy Controller

  • Chau, MinhThuyen;Luo, An;Shuai, Zhikang;Ma, Fujun;Xie, Ning;Chau, VanBao
    • Journal of Power Electronics
    • /
    • 제12권5호
    • /
    • pp.800-812
    • /
    • 2012
  • This paper analyses the mathematical model and control strategies of a Hybrid Active Power Filter with Injection Circuit (IHAPF). The control strategy based on the load harmonic current detection is selected. A novel control method for a IHAPF, which is based on the analyzed control mathematical model, is proposed. It consists of two closed-control loops. The upper closed-control loop consists of a single fuzzy logic controller and the IHAPF model, while the lower closed-control loop is composed of an Adaptive Network based Fuzzy Inference System (ANFIS) controller, a Neural Generalized Predictive (NGP) regulator and the IHAPF model. The purpose of the lower closed-control loop is to improve the performance of the upper closed-control loop. When compared to other control methods, the simulation and experimental results show that the proposed control method has the advantages of a shorter response time, good online control and very effective harmonics reduction.

다중루프 PID 제어기의 자동 동조 (Automatic Tuning of Multi-Loop PID Controller)

  • 김진훈
    • 대한전기학회논문지
    • /
    • 제39권5호
    • /
    • pp.478-484
    • /
    • 1990
  • An automatic tuning method of a PID controller which is used for single input single output processes is proposed. In the proposed tuning method, the frequency response data model is adopted along with the performance index which is an integral of time weighted square error between reference model and process frequency response data model for tuning. This method is easier to retune when either the process dynamics is changed or the reference model is changed. Finally, an example is provided to show the usefulness of the method.

  • PDF

반브리지형 스위칭 전원의 설계 및 제어 (Design and Control of the Half-Bridge Type Switching Regulator)

  • 고영길;이광원
    • 대한전기학회논문지
    • /
    • 제33권2호
    • /
    • pp.76-82
    • /
    • 1984
  • This paper presents the design and the optimal control method of current-fed half-brige switching regulator. To achieve fast response load current variation is fed to control input, and simple optimal control model has been derived with provision of current control loop in the control circuit. Test results show that the control system model is correct and 5ms response time has been obtained at 25 KHz switching frequency.

  • PDF

동적 특성을 고려한 6축 로봇의 서보 파라미터 튜닝에 관한 연구 (The Study of Servo-Parameter Tuning Technique for 6-Axes Articulated Robot Manipulator in Consideration of Dynamic Characteristics)

  • 정원지;김효곤;이춘만;홍대선;박승규;서영교;이기상
    • 한국공작기계학회논문집
    • /
    • 제16권5호
    • /
    • pp.1-6
    • /
    • 2007
  • This paper presents a new experimental Servo-Parameter tuning technique for a 6-axes articulated robot manipulator, especially considering robot's dynamics. First of all, investigation for proportional gain of velocity control loop by using a Dynamic Signal Analyzer(DSA) is performed. Using the FUNCTION characteristic of DSA based on the Bode plot, the Bode plot of open loop transfer function can be obtained. In turn, the integral gain of a servo controller can be found out by using the integration time constant extracted from the Bode plot of open loop transfer function. In the meanwhile, the positional gain of the servo controller can be obtained by using the Bode plot of the closed loop transfer function. Using the experimental gain tuning technique proposed in this paper, the testing linear motion of DR6-II robot has been shown to be more accurate rather than the motion with a conventional(empirical) gain tuning technique in Doosan Mecatec Co., Ltd., by improving the dynamic response of the robot as well as synchronizing each joint velocity according to the positional command of an end-effector.