• Title/Summary/Keyword: Response Measurement Point

Search Result 159, Processing Time 0.027 seconds

Assessment of Zinc Requirement for Human (인체의 아연필요량 측정방법)

  • 윤진숙
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.24 no.2
    • /
    • pp.346-353
    • /
    • 1995
  • The dietary requirement for zinc to maintain optimally the various metabolic and physiological funcitons is still under study. Human beings adapt to reductions in zinc intake by reducing the rate of growth or zinc excretion. Reductions in dietary zinc beyond the capacity to maintain homeostasis lead to utilization of zinc from an exchangeable pool. Loss of a small, critical amount of zinc from this pool leads to both biochemical and clinical signs of zinc deficiency. Zinc requirements have been assessed by balance studies and factorial method. As tissue zinc status influences endogenous losses and the dietary needs, individuls in good status may require higher amounts of zinc than those in poor status. While plasma zinc is insensitive to reducitons in dietary zinc, it is regarded as a valid, useful indicator of the exchangeable pool of zinc. Plasma metallothionein concentrations may prove useful for identifying poor zinc status. It has been suggested that functional end point measurement is the new direciton for zinc requirement. However, determination of the functional response to a marginal zinc intake is difficult because of the lack of a specific, sensitive indicator of zinc status. Presently, no good method for assessment of human zinc requirements exists.

  • PDF

A Survey on the M&V to guarantee the energy saving performance of ESCO (ESCO 에너지절약 성과보증의 M&V 적용사례 분석)

  • Lim, Ki Choo
    • Journal of Energy Engineering
    • /
    • v.23 no.2
    • /
    • pp.199-206
    • /
    • 2014
  • ESCO industry should guarantee the energy saving performance in response to changes of regulations ESCO. In this point, the application of the M&V is important task on energy saving performance. Therefore, we need to examine the contents of practice for the M&V in developed countries. Between energy user and ESCO, it is important to provide and measure the energy saving performance by guarantee of energy savings performance contracts. After 2013 ESCO business began focusing on guaranteed savings contracts. For this reason, we need to take M&V cases recommended from IPMVP and applied in United States and Japan. Therefore, we should be ready about M&V application for the real conditions of ESCO.

RESISTANCE ESTIMATION OF A PWM-DRIVEN SOLENOID

  • Jung, H.G.;Hwang, J.Y.;Yoon, P.J.;Kim, J.H.
    • International Journal of Automotive Technology
    • /
    • v.8 no.2
    • /
    • pp.249-258
    • /
    • 2007
  • This paper proposes a method that can be used for the resistance estimation of a PWM (Pulse Width Modulation)-driven solenoid. By using estimated solenoid resistance, the PWM duty ratio was compensated to be proportional to the solenoid current. The proposed method was developed for use with EHB (Electro-Hydraulic Braking) systems, which are essential features of the regenerative braking system of many electric vehicles. Because the HU (Hydraulic Unit) of most EHB systems performs not only ABS/TCS/ESP (Electronic Stability Program) functions but also service braking function, the possible duration of continuous solenoid driving is so long that the generated heat can drastically change the level of solenoid resistance. The current model of the PWM-driven solenoid is further developed in this paper; from this a new resistance equation is derived. This resistance equation is solved by using an iterative method known as the FPT (fixed point theorem). Furthermore, by taking the average of the resistance estimates, it was possible to successfully eliminate the effect of measurement noise factors. Simulation results showed that the proposed method contained a sufficient pass-band in the frequency response. Experimental results also showed that adaptive solenoid driving which incorporates resistance estimations is able to maintain a linear relationship between the PWM duty ratio and the solenoid current in spite of a wide variety of ambient temperatures and continuous driving.

Numerical convergence and validation of the DIMP inverse particle transport model

  • Nelson, Noel;Azmy, Yousry
    • Nuclear Engineering and Technology
    • /
    • v.49 no.6
    • /
    • pp.1358-1367
    • /
    • 2017
  • The data integration with modeled predictions (DIMP) model is a promising inverse radiation transport method for solving the special nuclear material (SNM) holdup problem. Unlike previous methods, DIMP is a completely passive nondestructive assay technique that requires no initial assumptions regarding the source distribution or active measurement time. DIMP predicts the most probable source location and distribution through Bayesian inference and quasi-Newtonian optimization of predicted detector responses (using the adjoint transport solution) with measured responses. DIMP performs well with forward hemispherical collimation and unshielded measurements, but several considerations are required when using narrow-view collimated detectors. DIMP converged well to the correct source distribution as the number of synthetic responses increased. DIMP also performed well for the first experimental validation exercise after applying a collimation factor, and sufficiently reducing the source search volume's extent to prevent the optimizer from getting stuck in local minima. DIMP's simple point detector response function (DRF) is being improved to address coplanar false positive/negative responses, and an angular DRF is being considered for integration with the next version of DIMP to account for highly collimated responses. Overall, DIMP shows promise for solving the SNM holdup inverse problem, especially once an improved optimization algorithm is implemented.

A study on the basic slacks pattern for the production of school uniforms for boys aged 13 to 18 (13~18세 남학생의 교복 제작을 위한 슬랙스 원형 연구)

  • Hong, Eun-Hee
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.21 no.3
    • /
    • pp.149-160
    • /
    • 2019
  • Body fit should be the first point considered for satisfying the functionality of clothes and thus it is the most essential condition. Based on previous research, this article studied the basic slacks pattern with a high body fit using body measurement of adolescent boys. The purpose of this study is to propose basic data for the production of slacks. Research was performed on the physical measurements of adolescent boys from 13-18 years old obtained from the '6th Korean National Physical Standard Reports' by SIZEKOREA. First, six types of experimental slacks basic patterns were produced applying the average body sizes of adolescent boys. Second, a single slacks basic pattern was selected, which received the best response based on appearance from the clothing evaluators. Then, the slacks basic pattern for adolescent boys was finalized by modifying and amending the selected pattern with two more clothing experiments. The data analysis was performed using descriptive statistics, ANOVA, and t-test using the SPSS program. The results of this study have been obtained as follows. The modifications and adjustments were done based on Crotch, Thigh Circumference, waist circumference, and hip circumference.

Earthquake Movement Measurement of the Top of Bridge Pier Using Fiber Optic Smart Structure Concept (광섬유 스마트 구조물의 개념을 이용한 교량상부 내진거동 측정)

  • Kim Ki-Soo;Han In-Dong
    • Composites Research
    • /
    • v.19 no.3
    • /
    • pp.43-49
    • /
    • 2006
  • In this paper, a long gauge Fiber Bragg Grating (FBG) sensor system is described and long gauge FBGs are well-suited for measuring the upper parts of the bridge piers under the extremely severe movement conditions. In the experiments, we used more than 30m long FBG sensors to measure the movement of top part of the bridge piers which are separated from the main bridge by cutting the decks. With the actuator, the deck and girders were pushed and released. We checked the movement of the top of the pier while releasing the pressure of the actuator with the long gauge fiber sensor. In order to measure the movement of the upper part of the pier, the reference point must be outside of the pier. Using the optical fiber sensors, one end of the sensor is attached to the top of the pier and the other end is attached to the bottom of the next pier. The fiber sensors showed good response to the release loading and we could calculate the movement of the top part of the pear.

A Development of Micro-Positioning Grinding Table using Piezoelectric Voltage Feedback (압전전압 궤환에 의한 미세구동 연삭테이블의 개발)

  • Nam, Soo-Ryong;Kim, Jeong-Du
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.2
    • /
    • pp.48-58
    • /
    • 1995
  • A micro positioning system using piezoelectric actuators have very wide application region such as ultra-precision machine tool, optical device, measurement systen. In order ro keep a high precision displacement resolution, they use a position sensor and feedback the error. From the practical point of view, a high-resolution displacement sensor system are very expensive and difficult to guarantee such sensitive sensors work properly in the hard opera- tion environment of industry. In this study, a micro-positioning grinding table which does not require position sensor but uses piezoelectric voltage feedback, has been developed. It is driven by hystersis-considering reference input voltage which calculated from computer and then uses actuator/sensor characteristics of piezoelectric materials. From the result of experiments we proved a fast and stable response of micro-positioning system and suggested efficient technique to control the piezoelectric actuator. And through grinding experiments, it is revealed that a characteristics of ground surfaces transient to plastic deformation as extremely small depth of grinding.

  • PDF

Development of a Moisture Content Sensor for Rapeseed as Biodiesel Raw Material (바이오디젤 원료용 유채 함수율 센서 개발)

  • Lee, Choung-Keun;Choi, Yong;Jun, Hyun-Jong;Jung, Kwang-Sik
    • Journal of Biosystems Engineering
    • /
    • v.34 no.1
    • /
    • pp.15-20
    • /
    • 2009
  • This study was conducted to develop a moisture sensor for rapeseed, a bio-diesel material. A typical rapeseed, SUNMANG, was used as a raw material. The rapeseed moisture content sensor consists of three components, such as upper and bottom electrodes, a test material dish, and a fixing housing. To evaluate the performance, a data acquisition system was equipped with the rapeseed moisture sensor, computer, printer, and main board. The findings of this study were: 1) the rapeseed moisture content was inversely proportional to electric resistance, and 2) values of electric resistance were recorded in a range of $10{\sim}100\;M{\Omega}$, depending upon a change of the moisture content. The determination of coefficient ($R^2$) and standard error between rapeseed moisture content and electric resistance were 0.9921 and ${\pm}0.289$, which indicated a highly correlative relationship. The response of rapeseed moisture sensor to temperature change was also observed for further performance test. Satisfying results were obtained, such as the determination of coefficient ($R^2$) of 0.9918, predicted standard error of ${\pm}0.373%$, deviation of 0.103%, measurement error of $0.14{\sim}0.48%$, standard deviation of $0.01{\sim}0.22%$, and measurement time of 28.3 s per point, respectively.

Determinants of Relative Weights on Financial and Non-Financial Performance Measures in the Food service Industry (외식산업의 BSC 구축에 대한 연구 - 국내 패밀리 레스토랑의 성과측정항목의 가중치 개발을 중심으로 -)

  • Oh, Yon-Serk;Jung, Soon-Yeo
    • Proceedings of the Culinary Society of Korean Academy Conference
    • /
    • 2006.08a
    • /
    • pp.21-44
    • /
    • 2006
  • Measuring and evaluating the business performance plays a very important role in managing business. It is because business performance, in any types of industry, can be evaluated and managed properly only when the measurement of its performance is estimated, and because its performance can be improved through an efficient and effective management. Therefore it is essential to build up the performance evaluation system to raise management efficiency of the foodservice industry, to reinforce competitive power of the food service industry. This study tried to propose a novel point of prospective and method in which the performance evaluation in any family restaurant should be illuminated and be performed. In this study, BSC provided the main conceptional framework for evaluating the performance of a family restaurant, and evaluation items of BSC four prospectives - financial, customers, internal business process, and learning and growth-were adjusted so as to be fitted into the business field. Furthermore, this study verified the validity of the proposed performance evaluation method through specific case analyses and used AHP to quantify its validity objectively. Finally, this study found the fact that non-financial prospectives, compared to financial prospectives, should be more importantly considered as the performance evaluation index of the family restaurants. Especially, the study showed that the proportion of performance evaluation indexes related to Customers prospective and Learning and Growth prospective revealed very highly, therefore variables such as customer satisfaction index, per employee productivity, education and training, customer response rate, employee satisfaction index should be emphasized as key factors at the process of selecting indexes and measuring their performance evaluation of the food service industry.

  • PDF

Physical Model Experiment on the Seepage Characteristics through a Dam by using FDR Sensor (FDR 센서를 활용한 제체 누수특성의 실내 모형 실험 연구)

  • Kim, Gyoo-Bum;Im, Eunsang;Ryu, Ho-Cheol;Hwang, Chan-ik;Kim, Hyeong-Jong
    • The Journal of Engineering Geology
    • /
    • v.28 no.4
    • /
    • pp.715-726
    • /
    • 2018
  • Various methods, such as geophysical exploration, temperature measurement, and fiber optics, have been developed for detecting the seepage at a dam. In this study, in order to investigate the possibility of leakage detection using dielectric constant of FDR sensor, a physical model consisting of weak and no-weak zones is fabricated and the sensors for dielectric constant, temperature and pore water pressure measurements are installed. As a leakage happens, the dielectric constant changes more rapidly through a weak zone than no-weak zone. In addition, comparing three factors (dielectric constant, temperature, and pore water pressure), the response of dielectric constant to seepage is fast and it is easily recognized even at the end measurement point. Considering these features, it is concluded that it could be possible to cope with the leakage detection quickly and efficiently if the dielectric constant is measured at the downstream slope of a dam.