• 제목/요약/키워드: Response Factor

검색결과 4,425건 처리시간 0.037초

고속철도교량의 동적응답에 의한 충격계수 산정 (Impact Factor of High-Speed Railway Bridges from Dynamic Response under KTX Running)

  • 윤혜진;진원종;곽종원;황의승;김병석
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.1631-1635
    • /
    • 2011
  • To consider dynamic magnification effect at the static design stage, impact load factor is applied to design load. Current impact load factor adopted EUROCODE without verification while Japan suggested impact load factor including velocity of high-speed train throughout theoretical and experimental studies. On the purpose of evaluate current impact load factor, this study investigated the calculation of impact load factor from dynamic response of running train.

  • PDF

Selection of Canonical Factors in Second Order Response Surface Models

  • Park, Sung H.;Seong K. Han
    • Journal of the Korean Statistical Society
    • /
    • 제30권4호
    • /
    • pp.585-595
    • /
    • 2001
  • A second-order response surface model is often used to approximate the relationship between a response factor and a set of explanatory factors. In this article, we deal with canonical analysis in response surface models. For the interpretation of the geometry of second-order response surface model, standard errors and confidence intervals for the eigenvalues of the second-order coefficient matrix play an important role. If the confidence interval for some eigenvalue includes 0 or the estimate of some eigenvalue is very small (near to 0) with respect to other eigenvalues, then we are able to delete the corresponding canonical factor. We propose a formulation of criterion which can be used to select canonical factors. This criterion is based on the IMSE(=Integrated Mean Squared Error). As a result of this method, we may approximately write the canonical factors as a set of some important explanatory factors.

  • PDF

기기의 지진취약도 평가를 위한 구조물 비탄성구조응답계수의 재평가 (Revaluation of Inelastic Structural Response Factor for Seismic Fragility Evaluation of Equipment)

  • 박준희;최인길
    • 한국전산구조공학회논문집
    • /
    • 제28권3호
    • /
    • pp.241-248
    • /
    • 2015
  • 원자력발전소에는 전력생산과 안전과 관련된 수많은 기기들이 존재하고 있다. 기본적으로 원자력발전소의 구조물과 기기는 지진시 탄성거동올 목표로 안전율을 매우 높게 적용하여 설계해 왔다. 그러나 최근 발생한 지진의 규모가 증가함에 따라 설계수준을 초과한 지진에 대한 기기의 안전성을 재평가할 필요가 있다. 본 연구에서는 구조물의 비선형 거동에 의한 층응답을 분석하였고, 비선형해석에 의한 구조물의 비탄성구조응답계수를 재평가하였다. 기기의 지진취약도 평가시 구조물의 비탄성구조응답이 어떤 영향을 주는지 분석하기 위하여 재평가된 구조물의 비탄성구조응답계수와 기존에 사용되어온 구조물 비탄성구조응답계수를 적용하여 지진취약도 평가를 수행하였다. 해석결과에 따르면 비탄성구조응답계수는 기기의 고유진동수, 기기의 위치 그리고 구조물의 동특성에 따라 영향을 받는 것으로 나타났다.

비보강 조적조 건물의 반응 수정 계수에 관한 연구 (A Study on the Response Modification Factor of Unreinforced masonry Buildings)

  • 정상훈
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1999년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall
    • /
    • pp.265-272
    • /
    • 1999
  • there is no earthquake resistant design code for the unreinforced masonary(URM) buildings in Korea. But it does not mean that all URM buldings in Korea is safe under the possible extent of an earthquake. The purpose of this study is in the inelastic analysis of unreinforced masonary walls with many different types of openings and carry out their ductilities an strengths, response modification factor of each wall has been compared and the most appropriate response modification factor for URM building in Korea has been proposed.

  • PDF

부하변동에 속응하는 역률개선형 전력절감시스템 (Electric energy saving system with high speed response to load variation using power-factor correction)

  • 김태수;강형식;주경돈;류승헌;구경완;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 D
    • /
    • pp.2388-2390
    • /
    • 2002
  • Small type electric energy saving system is proposed in this paper. The system improves power factor fastly according to load variation of each customer. Phases of voltage and current are detected as 1[ms] unit. Phase coincident algorithm is applied for power factor improvement. Capacitance is controlled for optimal power factor correction. Series reactor is controlled for harmonics reduction. Non-contact device is used for fast response and long life. Test result shows the effect of this system. Power factor of 40[W] electric fan is improved from 95[%] to 100[%]. In the case of electric light, power factor is improved from 82[%] to 100[%]. Response time for load variation is less than 1[ms].

  • PDF

Seismic Design of Structures in Low Seismicity Regions

  • 이동근;조소훈;고현
    • 한국지진공학회논문집
    • /
    • 제11권4호
    • /
    • pp.53-63
    • /
    • 2007
  • Seismic design codes are developed mainly based on the observation of the behavior of structures in the high seismicity regions where structures may experience significant amount of inelastic deformations and major earthquakes may result in structural damages in a vast area. Therefore, seismic loads are reduced in current design codes for building structures using response modification factors which depend on the ductility capacity and overstrength of a structural system. However, structures in low seismicity regions, subjected to a minor earthquake, will behave almost elastically because of the larger overstrength of structures in low seismicity regions such as Korea. Structures in low seismicity regions may have longer periods since they are designed to smaller seismic loads and main target of design will be minor or moderate earthquakes occurring nearby. Ground accelerations recorded at stations near the epicenter may have somewhat different response spectra from those of distant station records. Therefore, it is necessary to verify if the seismic design methods based on high seismicity would he applicable to low seismicity regions. In this study, the adequacy of design spectra, period estimation and response modification factors are discussed for the seismic design in low seismicity regions. The response modification factors are verified based on the ductility and overstrength of building structures estimated from the farce-displacement relationship. For the same response modification factor, the ductility demand in low seismicity regions may be smaller than that of high seismicity regions because the overstrength of structures may be larger in low seismicity regions. The ductility demands in example structures designed to UBC97 for high, moderate and low seismicity regions were compared. Demands of plastic rotation in connections were much lower in low seismicity regions compared to those of high seismicity regions when the structures are designed with the same response modification factor. Therefore, in low seismicity regions, it would be not required to use connection details with large ductility capacity even for structures designed with a large response modification factor.

병원 간호사의 감정노동 관련 변인에 관한 메타분석 (Meta Analysis of Variables related to Emotional Labor of Hospital Nurses)

  • 김종경;김정희
    • 기본간호학회지
    • /
    • 제23권2호
    • /
    • pp.115-125
    • /
    • 2016
  • Purpose: The purpose of this study was to use meta-analysis to evaluate factors and variables related to the emotional labor of hospital nurses. Method: The study included variables obtained from 66 recently published studies, doctoral dissertations, and master's theses. Results: The related variables were categorized into five factor groups: internal character factor, nursing care related factor, environmental factor, emotional response, and job response. For the defensive variable, job related response (effect size [ES]=-.17), environment (ES=-.14), internal character (ES=-.08), nursing care (ES=-.06), and emotional response (ES=-.06) showed significant effect size among the five categorized variable groups. For the risk variable, internal character (ES=.44), emotional response (ES=.46), environment (ES=.27), job related response (ES=.27), and nursing care (ES=.19) showed significant effect size among the five categorized variable groups. Conclusion: The results of this study identified defensive and risk variables related to emotional labor of hospital nurses. Self-efficacy, social support, leaders' care, and communication are important factors for managing emotional labor of hospital nurses.

벽식 APT의 반응수정계수 추정에 관한 연구 (Evaluation of Response Modification Factors for Shear Wall Apartment Building)

  • 송정원;송진규;이수곤
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.859-864
    • /
    • 2001
  • For earthquake resistance design, a response modification factor is used to reduce the design strength and it reflects ductility, reserve strength, redundancy and damping effect. But this factor has not theoretical basis. In this study, two response modification factors are compared and analyzed for shear wall apartment building.; the one is introduced by ATC-19 Procedures, the other is suggested FEMA-273 and ATC-40 through nonlinear static analysis. For the results, ATC-19 procedure gives a reasonable estimation to R factor. But $R_{u}$ by using FEAM-273 and ATC-40 methods is estimated so small in case of a minor or moderate earthquake region. Due to this fact, response modification factor is smaller than suggested load criterion 3.0. So, it needs to decrease wall volume and reduce the global strength and system stiffness for proper ductile behavior matching to domestic load criterion.

  • PDF

고속철도교량의 동적응답에 의한 충격계수 평가 (Evaluation of Impact Factor of High-Speed Railway Bridges from Dynamic Response under KTX Running)

  • 윤혜진;진원종;곽종원;황의승;김병석
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.1636-1640
    • /
    • 2011
  • To consider dynamic magnification effect at the static design stage, impact factor is applied to design load. Current impact factor adopted EUROCODE without domestic verification through theoretical and experimental studies. This study evaluated impact factor of railway bridges from dynamic response under KTX running. Moving Average Method was applied to calculate impact factor. Investigation considering different type of bridges and tracks including velocity was conducted.

  • PDF

고층 아파트 구조시스템에 따른 내진성능 분석 (Seismic Capacity according to Structural System of High-rise Apartment)

  • 이민희;조소훈;김종호;김형도
    • 한국전산구조공학회논문집
    • /
    • 제32권3호
    • /
    • pp.149-154
    • /
    • 2019
  • 국내 고층 아파트의 구조시스템은 크게 다수의 벽체가 분산적으로 배치되어 있는 내력벽 시스템과 중앙 코어벽 시스템으로 구분할 수 있다. 각각 시스템에 따른 횡방향 거동을 분석하기 위해 본 연구는 국내 고층 아파트 중 대표적인 평면을 갖는 대상 건물을 선정하고, 비선형 정적해석을 수행하여 붕괴메커니즘을 살펴보았다. 비선형 정적해석을 통해 도출된 힘-변위관계로부터 지진응답에 있어서 중요한 요소인 초과강도계수 및 연성도계수를 산정하여 반응수정계수를 평가하였다. 중앙 코어벽 시스템은 연성도는 작지만, 풍하중에 의해 지배되어 초과강도가 크게 산정돼 초과강도계수에 의해 반응수정계수가 산정되었고, 내력벽 시스템은 벽량이 많아 연성도가 크기 때문에 상당힌 큰 반응수정계수가 산정된다.