• Title/Summary/Keyword: Response Curve

Search Result 1,093, Processing Time 0.028 seconds

Effect of compressible membrane's nonlinear stress-strain behavior on spiral case structure

  • Zhang, Qi-Ling;Wu, He-Gao
    • Structural Engineering and Mechanics
    • /
    • v.42 no.1
    • /
    • pp.73-93
    • /
    • 2012
  • With an active structural involvement in spiral case structure (SCS) that is always the design and research focus of hydroelectric power plant (HPP), the compressible membrane sandwiched between steel spiral case and surrounding reinforced concrete was often assumed to be linear elastic material in conventional design analysis of SCS. Unfortunately considerable previous studies have proved that the foam material serving as membrane exhibits essentially nonlinear mechanical behavior. In order to clarify the effect of membrane (foam) material's nonlinear stress-strain behavior on SCS, this work performed a case study on SCS with a compressible membrane using the ABAQUS code after a sound calibration of the employed constitutive model describing foam material. In view of the successful capture of fitted stress-strain curve of test by the FEM program, we recommend an application and dissemination of the simulation technique employed in this work for membrane material description to structural designers of SCS. Even more important, the case study argues that taking into account the nonlinear stress-strain response of membrane material in loading process is definitely essential. However, we hold it unnecessary to consider the membrane material's hysteresis and additionally, employment of nonlinear elastic model for membrane material description is adequate to the structural design of SCS. Understanding and accepting these concepts will help to analyze and predict the structural performance of SCS more accurately in design effort.

Corrosion effects on tension stiffening behavior of reinforced concrete

  • Shayanfar, M.A.;Ghalehnovi, M.;Safiey, A.
    • Computers and Concrete
    • /
    • v.4 no.5
    • /
    • pp.403-424
    • /
    • 2007
  • The investigation of corrosion effects on the tensile behavior of reinforced concrete (RC) members is very important in region prone to high corrosion conditions. In this article, an experimental study concerning corrosion effects on tensile behavior of RC members is presented. For this purpose, a comprehensive experimental program including 58 cylindrical reinforced concrete specimens under various levels of corrosion is conducted. Some of the specimens (44) are located in large tub containing water and salt (5% salt solution); an electrical supplier has been utilized for the accelerated corrosion program. Afterwards, the tensile behavior of the specimens was studied by means of the direct tension tests. For each specimen, the tension stiffening curve is plotted, and their behavior at various load levels is investigated. Average crack spacing, loss of cross-section area due to corrosion, the concrete contribution to the tensile response for different strain levels, and maximum bond stress developed at each corrosion level are studied, and their appropriate relationships are proposed. The main parameters considered in this investigation are: degree of corrosion ($C_w$), reinforcement diameter (d), reinforcement ratio (${\rho}$), clear concrete cover (c), ratio of clear concrete cover to rebar diameter (c/d), and ratio of rebar diameter to reinforcement percentage ($d/{\rho}$).

Development of A New Micro-fabricated AFM Probe for the Measurement of Biomaterials by using the Precision Glass Bead Supply Unit (글래스비드 정밀공급기구에 의한 바이오재료평가용 AFM프로브의 개발)

  • Kweon, H.K.;Lin, J.
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.6
    • /
    • pp.30-36
    • /
    • 2014
  • Many different cells types have been found to be highly sensitive to mechanical force imposed by their surroundings. The cellular response to external mechanical forces has very important effects on numerous biological phenomena. In spite of its importance in biological processes, the cell adhesion force remains difficult to measure quantitatively at the cellular level. In this paper, to enhance quantitative measurements of cell adhesive interactions, a new attaching system and a method in which a glass bead can be attached to an AFM cantilever was designed and fabricated, and the degree of range displacement was controlled in the system. In an experiment, the movement of the stage in the attaching system and the attaching process were measured. The effectiveness of this system was confirmed as well in the experiment. In addition, through a commercial AFM system, the spring constant of the modified AFM probe could be measured.

An ionization Chamber for a Steel Sheet Thickness Measurement

  • Kim, Han-Soo;Park, Se-Hwa;Kim, Yong-Kyun;Ha, Jang-Ho;Cho, Seung-Yeon
    • Journal of Radiation Protection and Research
    • /
    • v.31 no.3
    • /
    • pp.149-153
    • /
    • 2006
  • An ionization chamber is still widely used in many fields by virtue of its' simple operational characteristics and the possibility of its' various shapes. A parallel type of an ionization chamber for a steel sheet thickness measurement was designed and fabricated. High pure xenon gas, which was pressurized up to 6 atm, was chosen as a filling gas to increase the current response and sensitivity for a radiation. A high pressure gas system was also constructed. The active volume and the incident window size of the fabricated ionization chamber were $30\;cm^3\;and\;12\;cm^2$, respectively. Preliminary tests with a 25 mCi $^{241}Am$ gamma-ray source and evaluation tests in a standard X-ray field were performed. The optimal operation voltage was set from the results of the collection efficiency calculation by using an experimental two-voltage method. Linearity for a variation of the steel sheet thickness, which is the most important factor for an application during a steel sheet thickness measurement, was 0.989 in this study.

Flexural Design and Ductile Capacity of Reinforced High Strength Concrete Beams (고강도 철근 콘크리트 보의 휨 설계 및 연성능력)

  • 신성우;유석형;안종문;이광수
    • Magazine of the Korea Concrete Institute
    • /
    • v.8 no.6
    • /
    • pp.141-149
    • /
    • 1996
  • The reinforced high-strength-concrete beam subjected to flexure moment behaves more brittly than the moderate-strength-concrete beam reinforced with equal reinforcement ratio($\rho$/$\rho_b$). Test results show that when the concrete strength exceeds 830kg/$cm^2$, the maximum reinforcement ratio should be less than $0.6{\rho}_b$ for ductile behavior (${\rho}_b$=balanced steel ratio). The ratio of flexural strength between experimental results and analytical results with rectangular stress block decrease as the compressive strength of concrete increase. The shape of the compressive stress block distributed triangularly. because the ascending part of the stress-strain curve shows fairly linear response up to maximum stress in contrast to the nonlinear behavior of the medium and low strength specimens.

Comparison of 5 Assays for Quantification of Antibody to Hepatitis B Virus Surface Antigen with Immunoglobulin G Preparations (면역글로불린제제 효능평가를 위한 5종 B형간염 표면항원항체검출법의 비교)

  • Shin, In-Soo;Lee, Yoo-Kyoung;Kim, Oh-Jung;Ban, Sang-Ja
    • KSBB Journal
    • /
    • v.26 no.2
    • /
    • pp.157-164
    • /
    • 2011
  • Five assays for anti-HBs were compared to improve potency test of Human lgG preparations. The three commercial EIA kits were optimized including dose response curve ranges and compared by conducting a co-laboratory study. After selecting the most reproducible EIA kit, methods comparison was performed with 22 samples in 5 different days. As a result, EIA (7.7 ${\pm}$ 5.3%) and MEIA (AxSYM: 3.7 ${\pm}$ 1.9%, IMx: 1.6 ${\pm}$ 0.8%) showed precision and accuracy (100.1 ${\pm}$ 12.6%). Therefore, the validated EIA assay was established and it is believed to be comparable to current MEIA.

A Modeling and Optimal Site of SMES for Power System Stabilization (계통안정화를 위한 SMES의 모델링과 적정위치 선정)

  • Kim, Jeong-Hun;Im, Jae-Yun;Lee, Jong-Pil
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.5
    • /
    • pp.494-501
    • /
    • 1999
  • In this research, ANN modeling method of SMES unit is developed for stability analysis, and the optimal site is selected to maximize stabilization effect of SMES unit. The ANN is trained by learning data which is obtained through the application of complex test function into the traditional mathematical mode. In order to verify the validity of proposed modeling method, fault data of sample power system is applied to both the traditional and the ANN models. When the response of traditional and proposed models are compared, the average error for the active and reactive power are 2.51[%], and 0.24[%], respectively. From the comparison, the relevance of proposed method is validated. For the transient stability analysis, an application method of the proposed model is presented, and the transient stability performance index, which describes system stabilization effect of SMES at disturbance, is also suggested, and optimal site selection method of SMES is presented. In the viewpoint of the voltage stability, system stabilization criterion of local bus is presented from P­V curve, and then optimal site which can maximize the voltage stabilization of the whole power system, is decided from the proposed voltage stability performance index.

  • PDF

Polyopes lancifolia Extract, a Potent α-Glucosidase Inhibitor, Alleviates Postprandial Hyperglycemia in Diabetic Mice

  • Min, Seong Won;Han, Ji Sook
    • Preventive Nutrition and Food Science
    • /
    • v.19 no.1
    • /
    • pp.5-9
    • /
    • 2014
  • This study was designed to investigate the inhibitory effects of Polyopes lancifolia extract (PLE) on ${\alpha}$-glucosidase activity, ${\alpha}$-amylase activitiy, and postprandial hyperglycemia in streptozotocin (STZ)-induced diabetic mice. The results of this study revealed a marked inhibitory effect of PLE on ${\alpha}$-glucosidase and ${\alpha}$-amylase activities. The $IC_{50}s$ of PLE against ${\alpha}$-glucosidase and ${\alpha}$-amylase were 0.20 mg/mL and 0.35 mg/mL, respectively. PLE was a more effective inhibitor of ${\alpha}$-glucosidase and ${\alpha}$-amylase activities than acarbose, the positive control. The postprandial blood glucose levels of STZ-induced diabetic mice were significantly lower in the PLE treated group than in the control group. Moreover, PLE administration was associated with a decreased area under the curve for the glucose response in diabetic mice. These results indicate that PLE may be a potent inhibitor of ${\alpha}$-glucosidase and ${\alpha}$-amylase activities and may suppress postprandial hyperglycemia.

Tuning-free Anti-windup Strategy for High Performance Induction Machine Drives (고성능 유도전동기 구동을 위한 자동 튜닝 Anti-windup 기법)

  • Seok Jul-Ki;Lee Dong-Choon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.1
    • /
    • pp.29-37
    • /
    • 2005
  • This paper presents a tuning-free conditional integration anti-windup strategy for induction machine with Proportional-Integral(PI) type speed controller. The on/off condition of integral action is determined by the frequency domain analysis of machine torque command without a prior knowledge of set-point changes. There are no tuning parameters to be selected by users for anti-windup scheme. In addition, the dynamic performance of the proposed scheme assures a desired tracking response curve with minimal oscillation and settling time even in the change of operating conditions. This algorithm is useful in many high performance induction machine applications not to allow the oscillation and overshoot of speed/torque responses. The main idea can be extended to general applications such as chemical processes and industrial robots.

A High-Performnce Sensorloss Control System of Reluctance Synchronous Motor with Direct Torque Control by Consideration of Nonlinerarly Inductances

  • Kim, Min-Huei;Kim, Nam-Hun;Baik, Won-Sik
    • Journal of Power Electronics
    • /
    • v.2 no.2
    • /
    • pp.146-153
    • /
    • 2002
  • this paper presents an implementation of digital control system of speed sensorless for Reluctance Synchronous Motor (RSM) drives with direct torque control (DTC). The problem of DTC for high-dynamic performance RSM drive is generating a nonlinear torque due to a saturated nonlinear inductance curve with various load currents. The control system consists of stator flux observer, compensating inductance look-up table, rotor position/speed/torque estimator, two hysteresis band controllers, an optimal switching look-up table, IGBT voltage source unverter, and TMS320C31 DSP controller. The stator flux observer is based on the combined voltage and current model with stator flux feedback adapitve control that inputs are the compensated inductances, current and voltage sensing of motor terminal with estimated rotor angle for wide speed range. The rotor position is estimated rotor speed is determined by differentiation of the rotor position used only in the current model part of the flux observer for a low speed operation area. It does not requrie the knowledge of any montor paramenters, nor particular care for moter starting, In order to prove the suggested control algorithm, we have simulation and testing at actual experimental system. The developed sensorless control system is showing a good speed control response characterisitic result and high performance features in 20/1500 rpm with 1.0Kw RSM having 2.57 ratio of d/q reluctance.