• Title/Summary/Keyword: Resonance method

Search Result 2,472, Processing Time 0.026 seconds

Optimization of the Unimorph Cantilever Generator (UCG) Using Pb(Zr0.54Ti0.46)O3 + 0.2 wt% Cr2O3 + 1.0 wt% Nb2O5 thick films (Pb(Zr0.54Ti0.46)O3 + 0.2 wt% Cr2O3 + 1.0 wt% Nb2O5 조성의 압전 후막을 이용한 유니몰프형 캔틸레버 발전기(UCG)의 최적화)

  • Kim, Kyoung-Bum;Kim, Chang-Il;Yun, Ji-Sun;Jeong, Young Hun;Nahm, Jung Hee;Cho, Jeong-Ho;Paik, Jong-Hoo;Nahm, Sahn;Seong, Tae-Hyeon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.12
    • /
    • pp.955-960
    • /
    • 2012
  • We fabricated piezoelectric unimorph cantilever generators (UCG) using $Pb(Zr_{0.54}Ti_{0.46})O_3$ + 0.2 wt% $Cr_2O_3$ + 1.0 wt% $Nb_2O_5$ (PZCN) piezoelectric thick films, which were produced by a tape casting method. The PZCN thick films were tailored with same width and thickness but different lengths from 7.7 to 57.7 mm in order to evaluate optimized UCG for energy harvesting device applications. When the length of PZCN film was increased, the resonance frequency of UCG was slightly increased from 7 Hz to 8 Hz, which could be due to enlarged area of the highly stiff piezo-ceramic film. However, the output power was proportionally increased with the length of PZCT film and it reached 4.68 mW (1.221 $mW/cm^3$) when the film's length was 57.7 mm under 25 g of tip mass at 8 Hz, which is sufficient for micro-scale device applications.

Characterization of Layered Double Hydroxides(Mg-Al-$CO_3$ systems) and Rehydration Reaction of Their Calcined Products in Aqueous Chromate Solution (층상이중수산화물(Mg-Al-$CO_3$ 체계)의 물리 · 화학적 특성규명 및 소성된 시료의 크롬산이온 수용액에서 재수화반응)

  • Rhee, Seog Woo;Kang, Mun-Ja;Moon, Hichung
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.8
    • /
    • pp.627-634
    • /
    • 1995
  • Layered double hydroxides ($Mg-Al-CO_3$ systems, LDH), which are hydrotalcite-like anionic clay minerals, having different $Mg^{2+}\;to\;Al^{3+}$ ratio were synthesized by coprecipitation method. The subsequent products were characterized by the following methods; elemental analysis, X-ray powder diffraction, thermal analysis (DSC and TGA), FT-IR and $^{27}$Al-MAS NMR. X-ray powder patterns showed that the products formed were layered structure materials. Two heat absorption peaks were observed around 20 ∼280$^{\circ}C$ (surface water and interlayer water) and 280∼500$^{\circ}C$ (water from lattice hydroxide and carbon dioxide from interlayer carbonate) in DSC diagrams, and they were quantitatively analyzed by TGA diagrams (in case LDH4 16.2% and 28.6% respectively). FT-IR spectra indicate that the interlayer carbonate ions occupied symmetrical sites between two adjacent layers in a parallel direction. $^{27}$Al-MAS NMR spectra show only single resonance (8.6 ppm) of the octahedrally coordinated aluminum similar magnesium. When LDH4 was calcined at 560$^{\circ}C$ for 3 hours in air, its layered structure was destroyed giving a mixed metal oxide. However it readily became rehydrated in aqueous chromate solution to its original structure.

  • PDF

Sol-Gel Synthesis, Crystal Structure, Magnetic and Optical Properties in ZnCo2O3 Oxide

  • Das, Bidhu Bhusan;Barman, Bittesh
    • Journal of the Korean Chemical Society
    • /
    • v.63 no.6
    • /
    • pp.453-458
    • /
    • 2019
  • Synthesis of ZnCo2O3 oxide is performed by sol-gel method via nitrate-citrate route. Powder X-ray diffraction (XRD) study shows monoclinic unit cell having lattice parameters: a = 5.721(1) Å, b = 8.073(2) Å, c = 5.670(1) Å, β = 93.221(8)°, space group P2/m and Z = 4. Average crystallite sizes determined by Scherrer equation are the range ~14-32 nm, whereas SEM micrographs show nano-micro meter size particles formed in ZnCo2O3. Endothermic peak at ~798 K in the Differential scanning calorimetric (DSC) trace without weight loss could be due to structural transformation and the endothermic peak ~1143 K with weight loss is due to reversible loss of O2 in air atmosphere. Energy Dispersive X-ray (EDX) analysis profile shows the presence of elements Zn, Co and O which indicates the purity of the sample. Magnetic measurements in the range of +12 kOe to -12 kOe at 10 K, 77 K, 120 K and at 300 K by PPMS-II Physical Property Measurement System (PPMS) shows hysteresis loops having very low values of the coercivity and retentivity which indicates the weakly ferromagnetic nature of the oxide. Observed X-band EPR isotropic lineshapes at 300 K and 77 K show positive g-shift at giso ~2.230 and giso ~2.217, respectively which is in agreement with the presence of paramagnetic site Co2+(3d7) in the oxide. DC conductivity value of 2.875 ×10-8 S/cm indicates very weakly semiconducting nature of ZnCo2O3 at 300 K. DRS absorption bands ~357 nm, ~572 nm, ~619 nm and ~654 nm are due to the d-d transitions 4T1g(4F)→2Eg(2G), 4T1g(4F)→4T1g(4P), 4T1g(4F)→4A2g(4F), 4T1g(4F)→4T2g(4F), respectively in octahedral ligand field around Co2+ ions. Direct band gap energy, Eg~ 1.5 eV in the oxide is obtained by extrapolating the linear part of the Tauc plot to the energy axis indicates fairly strong semiconducting nature of ZnCo2O3.

Numerical Analysis and Verification of Sound Absorbing Properties of Perforated Plate (타공판의 등가 흡음 물성치 유도와 공명기로서의 흡음성능 해석)

  • Yoon, Gil-Ho;Kim, Ki-Hyun;Choi, Jung-Sik;Yun, Su-Hwan
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.2
    • /
    • pp.139-144
    • /
    • 2015
  • Recently, to realize sound-absorbing structures, we have to insert sound-absorbing materials into wall. These shapes are taken limitations because sound-absorbing materials should be fixed. Therefore, the sound absorption is changed by environment that used the sound-absorbing materials. On the other hand, we will take same effect without sound-absorbing material, if we change the shape of wall to sound absorbing structure. If we use this sound absorbing structure, we can get benefits by removing limitation of materials. Therefore we suggest perforated plate for effective sound-absorbing structure. We confirmed the function of sound-absorption of this structure using equivalent property. Then, we found the similarity between perforated plate and resonator. Also, we verify these theories through computer simulation by FEM(Finite Element Method). Finally, we validated that perforated plate has function of sound absorption without sound-absorbing material. This perforated plate is used for sound-absorbing material of buildings and transportations such as vehicle, train etc. Also, these results could be further used basic tool for design of sound-absorption structure.

Surgical Outcomes According to Dekyphosis in Patients with Ossification of the Posterior Longitudinal Ligament in the Thoracic Spine

  • Kim, Soo Yeon;Hyun, Seung-Jae;Kim, Ki-Jeong;Jahng, Tae-Ahn;Kim, Hyun-Jib
    • Journal of Korean Neurosurgical Society
    • /
    • v.63 no.1
    • /
    • pp.89-98
    • /
    • 2020
  • Objective : Ossification of posterior longitudinal ligament (OPLL) in the thoracic spine may cause chronic compressive myelopathy that is usually progressive, and unfavorable by conservative treatment. Although surgical intervention is often needed, the standard surgical method has not been established. Recently, it has been reported that posterior decompression with dekyphosis is effective surgical technique for favorable clinical outcome. The purpose of this study was to evaluate the surgical outcomes in patients with thoracic OPLL according to dekyphosis procedure and to identify predictive factors for the surgical results. Methods : A total of 25 patients with thoracic OPLL who underwent surgery for myelopathy from May 2004 to March 2017, were retrospectively reviewed. Patients with cervical myelopathy were excluded. We assessed the clinical outcomes according to various surgical approaches. The modified Japanese orthopedic association (JOA) scores for the thoracic spine (total, 11 points) and JOA recovery rates were used for investigating surgical outcomes. Results : Of the 25 patients, 10 patients were male and the others were female. The mean JOA score was 6.7±2.3 points preoperatively and 8.8±1.8 points postoperatively, yielding a mean recovery rate of 53.8±31.0%. The mean patients' age at surgery was 52.4 years and mean follow-up period was 40.2 months. According to surgical approaches, seven patients underwent anterior approaches, 13 patients underwent posterior approaches, five patients underwent combined approaches. There was no significant difference of the surgical outcomes related with different surgical approaches. Age (≥55 years) and high signal intensity on preoperative magnetic resonance (MR) image in the thoracic spine were significant predictors of the lower recovery rate after surgery (p<0.05). Posterior decompression with dekyphosis procedure was related to the excellent surgical outcomes (p=0.047). Dekyphosis did not affect the complication rates. Conclusion : In this study, our result elucidated that old age (≥55 years) and presence of intramedullary high signal intensity on preoperative MR images were risk factors related to poor surgical outcomes. In the meanwhile, posterior decompression with dekyphosis affected favorable clinical outcome. Posterior approach with dekyphosis procedure can be a recommendable surgical option for favorable results.

Antitumor Activity and Nephrotoxicity of the Novel Platinum(II) Coordination Complex (새로운 Platinum (II) Complex [Pt (II)(trans-d-dach)(DPPE)] $(NO_3)_2$의 항암효과 및 신독성에 관한 연구)

  • Jung Jee-Chang;Lee Moon-Ho;Chang Sung-Goo;Rho Young-Soo
    • The Korean Journal of Pharmacology
    • /
    • v.31 no.1 s.57
    • /
    • pp.103-114
    • /
    • 1995
  • Platinum coordination complexes are currently one of the most compounds used in the treatment of solid tumors. However, its use is limited by severe side effects such as renal toxicity. Our platinum-based drug discovery program is aimed at developing drugs capable of diminishing toxicity and improving antitumor activity. We synthesized new Pt (Ⅱ) complex analogue containing 1,2-diaminocyclohexane (dach) as carrier ligand and 1,2-bis(diphenylphosphino) ethane (DPPE) as a leaving group. Furthermore, nitrate was added to improve the solubility. A new series of [Pt(trans-ddach)(DPPE).$2NO_3(PC)$ was synthesized and characterized by their elemental analysis and by various spectroscopic techniques [infrared (IR), $^{13}carbon$ nuclear magnetic resonance (NMR)]. PC demonstrated acceptable antitumor activity aganist P388, L-1210 lymphocytic leukemia cells and SK=OV3 human ovarian adenocarcinoma cells, and significant. activity as compared with that. cisplatin. The toxicity of PC was found quite less than thar of cisplatin using MTT, $[^3H]$ thymidine uptake and glucose consumption tests in rabbit proximal tubule cells, human kidney cortical cells and human renal cortical tissues. Based on these results, this novel platinum compound represent a valuable lead in the development of a new anticancer chemotherapeutic agent capable of improving antitumor activity and low toxicity.

  • PDF

Susceptibility-Contrast-Enhanced MR Venography of Cat Brain Using Tailored RF Pulse at High Magnetic Field of 4.7 Tesla Superconducting Magnet (4.7T 고자장 초전도 자석에서 Tailored RF를 이용한 고양이 뇌의 자화율 강조영상법에 의한 자기공명혈관 조영술)

  • Moon, Chi-Woong;Kim, Sang-Tae;Lee, Dae-Geun;Im, Tae-Hwan;No, Yong-Man;Cho, Jang-Hee;Lee, Yoon
    • Progress in Medical Physics
    • /
    • v.5 no.1
    • /
    • pp.55-66
    • /
    • 1994
  • After proving home-made imaging pulse sequences including tailored RF pulse by phantom, susceptibility-contrast-enhanced MR venograms of cat brain were obtained using tailored RF gradient-echo(TRGE) method. Sagittal MR imaging of the cat brain obtained by TRGE technique shows several veins, for example, dorsal sagittal sinus, straight sinus, vein of corpus callosum and internal cerebral vein, etc., compared with cats anatomical figure. Tailored RF waveform was generated by PASCAL language in ASPECT 3000 computer(Switzland, Bruker). Rectangular-shaped slice profile with bi-linear ramp function as phase distribution in the slice, at which maximum value was 2$\pi$, was fourier transformed to make tailored RF pulse. Experimental MR imaging parameters were TR/TE=205/10 msec, slice thickness TH=7mm, maxtrix size=256$\times$256, in-plane resolution=0.62$\times$0.31mm$^2$, and field of view(FOV)=8cm for both conventional gradient-echo(GE) imaging and TRGE imaging techniques.

  • PDF

Working Memory Deficits in Patients with Schizophrenia:fMRI Investigation (정신분열병 환자의 작동기억 이상에 대한 기능적 자기공명영상 연구)

  • Park, Yuh-Jin;Kim, Tae-Suk;Roh, Sa-Bong;Pae, Chi-Un;Kim, Jung-Jin;Lee, Soo-Jung;Lee, Chul;Paik, In-Ho;Lee, Chang-Uk
    • Korean Journal of Biological Psychiatry
    • /
    • v.12 no.1
    • /
    • pp.32-41
    • /
    • 2005
  • Objective:Impaired processing of working memory is one of the cognitive deficits seen in patients with schizophrenia. This aimed at corroborating the differences in the brain activities involved in the process of working memory between patients with schizophrenia and the control subjects. Method:Fourteen patients with schizophrenia and 12 healthy volunteers were recruited in this study. Functional magnetic resonance imaging(fMRI) was used to assess cortical activities during the performance of a 2-back visual working memory paradigm using the Korean alphabet as mnemonic content. Results:Group analysis revealed that left lateral prefrontal cortex and right parietal lobule showed decreased cortical activities in the patient group. On the other hand, an increased activation in left superior and middle frontal gyrus, left middle temporal gyrus, right cuneus, both occipital lobes, right fusiform gyrus and right cingulate gyrus. The activation in left anterior lobe and both declive of cerebellum was also increased. Conclusions:This study showed a decreased activation in left lateral prefrontal and right parietal neural networks from the patient group and confirmed the earlier findings on the impaired working memory of patients with schizophrenia using fMRI investigation. The regions implicated in our study suggest an abnormal functioning of the fronto-parietal cortical areas that are critical to the information processing stream, which might be correspondent to common pathophysiology rather than a common etiology in schizophrenia.

  • PDF

Superior Gluteal Artery Perforator Turn-Over Flap Coverage for Lumboscaral Soft Tissue Defect in Ambulatory Patient (보행 환자에서의 위볼기동맥천공지뒤집기피판을 이용한 허리엉치 부위 연부조직 결손의 치료)

  • Moon, Suk-Ho;Kim, Dong-Seok;Oh, Deuk-Young;Lee, Jung-Ho;Rhie, Jong-Won;Seo, Je-Won;Ahn, Sang-Tae
    • Archives of Plastic Surgery
    • /
    • v.37 no.5
    • /
    • pp.712-716
    • /
    • 2010
  • Purpose: Extensive lumbosacral defects after removal of spinal tumors have a high risk of wound healing problems. Therefore it is an effective reconstructive strategy to provide preemptive soft tissue coverage at the time of initial spinal surgery, especially when there is an instrument exposure. For soft tissue reconstruction of a lumbosacral defect, a variation of the gluteal flap is the first-line choice. However, the musculocutaneous flap or muscle flap that is conventionally used, has many disadvantages. It damages gluteus muscle and causes functional disturbance in ambulation, has a short pedicle which limits areas of coverage, and can damage perforators, limiting further surgery that is usually necessary in spinal tumor patients. In this article, we present the superior gluteal artery perforator turn-over flap that reconstructs complex lumbosacral defects successfully, especially one that has instrument exposure, without damaging the ambulatory function of the patient. Methods: A 67 year old man presented with sacral sarcoma. Sacralectomy with L5 corpectomy was performed and resulted in a $15{\times}8\;cm$ sized complex soft tissue defect in the lumbosacral area. There was no defect in the skin. Sacral stabilization with alloplastic fibular bone graft and reconstruction plate was done and the instruments were exposed through the wound. A $18{\times}8\;cm$ sized superior gluteal artery perforator flap was designed based on the superior gluteal artery perforator and deepithelized. It was turned over 180 degrees into the lumbosacral dead space. Soft tissue from both sides of the wound was approximated over the flap and this provided in double padding over the instrument. Results: No complications such as hematoma, flap necrosis, or infection occurred. Until three months after the resection, functional disturbances in walking were not observed. The postoperative magnetic resonance imaging scan shows the flap volume was well maintained over the instrument. Conclusion: This superior gluteal artery perforator turn-over flap, a modification of the conventional superior gluteal artery perforator flap, is a simple method that enabled the successful reconstruction of a lumbosacral defect with instrument exposure without affecting ambulatory function.

Demand Surveys for Big Research Facilities and Equipments to Advance National S&T Research Infrastructure (과학기술 하부구조 선진화를 위한 대형 연구장비의 수요 조사)

  • 권용수;민철구
    • Proceedings of the Technology Innovation Conference
    • /
    • 1997.12a
    • /
    • pp.159-176
    • /
    • 1997
  • This paper deals with demand surveys for big science and technology research facilities and equipments to advance national S'||'&'||'T research infrastructure. We perform surveys thrice based on applied Delphi method on the future demand of big S'||'&'||'T research facilities and equipments among Korean scientists and engineers. We employ the concept of big S'||'&'||'T research facilities and equipments as follows: \circled1 The operating size of it is equivalent to that of an institute or research center, and/or \circled2 The users in various disciplines are many, and/or \circled3 The application areas or spill-over effects are large, and/or \circled4 The scale and scope of research objects is equivalent to that of mega science area such as earth.oceanography.space, and/or \circled5 The expenses for installing and operating it are to be supported by government, and/or \circled5 The facilities are expected as necessary for international joint research, and/or \circled7 It is necessary for promoting creative basic science and developing creative technology. We ask the respondents to answer the following questionnaire: - How to prioritize the equipments according to the degree of importance\ulcorner $\square$ Promotion of basic science and mega science, the development of the technologies to enhance the public welfare, the competitiveness of industrial technologies, the job creation for the S'||'&'||'T personnel, and international cooperation. - Who should be in charge of acquisition and operation of the equipments\ulcorner $\square$ Industry, Government Research Institutes, Academy, ERC and SRC. - When shall we acquire the equipment\ulcorner $\square$ Within 2000, 2002, 2007, 2012, and 2017. - How shall we acquire the equipments\ulcorner $\square$ International Joint Development, Domestic Development, Acquisition from Overseas, - How much will the equipment generate spill-over effects to national competitiveness\ulcorner $\square$ Promotion of basic science, contribution to the economy, supply of S'||'&'||'T personnel, and international cooperation. We suggest the following equipments as prioritized candidates after consulting the officers from MOST, MOE, MIC, MOEN and experts from KBSI and STEPI:(table omitted) where, #1, Korea Advanced Liquid Metal Reactor, #2. 800 MHz Superconduction Fourier-Transform Nuclear Magnetic Resonance Spectrometer, #3. Ion Accelerator, #4. Seismic Test Facility, #5. Transonic Wind Tunnel, #6. Radio Telescope for Very Long Baseline Interferometer, #7. 3000t Universal(or Large Structure) Testing Machine, #8. Compost Facility or Plasma Pyrolysis Facility.

  • PDF