• Title/Summary/Keyword: Resonance Frequency Shift

Search Result 85, Processing Time 0.027 seconds

Resonance Frequency and Quality Factor Tuning in Electrostatic Actuation of Nanoelectromechanical Systems

  • Kim, Dong-Hwan
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.9
    • /
    • pp.1711-1719
    • /
    • 2005
  • In an electro statically actuated nanoelectromechanical system (NEMS) resonator, it is shown that both the resonance frequency and the resonance quality (Q) factor can be manipulated. How much the frequency and quality factor can be tuned by excitation voltage and resistance on a doubly-clamped beam resonator is addressed. A mathematical model for investigating the tuning effects is presented. All results are shown based on the feasible dimension of the nanoresonator and appropriate external driving voltage, yielding up to 20 MHz resonance frequency. Such parameter tuning could prove to be a very convenient scheme to actively control the response of NEMS for a variety of applications.

Structural Safety and Critical Speed Analysis of 2-Speed Shift Reducer (2속 변속 감속기의 구조 안전성 분석과 위험속도 해석)

  • Kang, Jin Gyeong;Yoo, Young Rak;Park, Kyu Tae
    • Journal of Drive and Control
    • /
    • v.19 no.4
    • /
    • pp.1-9
    • /
    • 2022
  • The structure and operating principle of the 2-speed shift reducer were explained, the allowable bending stress value of the material was compared with the analysis result through FM structural analysis program, and the average stress distribution value of von Mises was performed on the gear root atmosphere. The structural safety of the 2-speed planetary gear reducer was verified through FM structural analysis. The natural frequency was calculated by applying the specifications of the planetary gears of the 2-speed gearbox, and the critical speed of resonance was calculated by calculating the natural frequency and the transmission error of the engaged gear pair. As a result of analyzing the critical speed, since it is formed higher than the actual operating speed range, it is considered safe because there is no resonance problem due to the suggested specifications of the planetary gears of the 2-speed shift reduction.

Noninvasive measuring;Detections of materials and quantities on eddy current testing

  • Obayashi, Koji;Tamura, Muneyoshi;Zhang, X.;Aoyama, T.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1555-1560
    • /
    • 2004
  • We made a simplified eddy-current-tester, and observed some materials for the ingredients and mass and locations. The tester detects the current as frequency shifts of a LC-resonance circuit, which are caused by the eddy currents. Using air-wick coil and a multi-piled ceramic capacitor, we made a resonance system whose frequency was 100KHz. The shift quantity is few; so, to detect it, we used a frequency counter, and counted the shift. We can detect 10Hz order's shift.

  • PDF

Analysis of Resonance Based Micromechanical Bio-Chemical Sensing Structures (공진 기반 마이크로기계 생화학 센싱 구조물의 해석)

  • Yeo, Min-Ku;Shin, Yoon-Hyuck;Yim, Hong-Jae;Lim, Si-Hyung
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1767-1772
    • /
    • 2008
  • A microcantilever is a well-known MEMS structure for sensing bio-chemical molecules. When bio-chemical molecules are adsorbed on the microcantilever's surface, resonance frequency shift is generated. There are two issues in this phenomena. The first one is which one between mass change and surface stress change effects is more dominant on the resonance frequency shift. The second one is what will be the performance change when the boundary condition is changed from cantilevers to double clamped beams. We have studied the effect of surface stress change and compared it with that of mass change by using FEM analysis. Furthermore, for microstructures having different boundary conditions, we have studied Q-factor, which determines the detection limit of micro/nano mechanical sensors.

  • PDF

The Characteristics of DC-shift in Hybrid Rocket (하이브리드 로켓에서의 DC-shift 발생 특성)

  • Kang, Dong-Hoon;Lee, Chang-Jin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.5
    • /
    • pp.456-466
    • /
    • 2010
  • Typical combustion instability such as DC-Shift found in the hybrid rocket motor is characterized by non-linearity. DC-Shift can occur in two different realizations. One is so-called a positive shift of measured DC voltage where the pressure increase suddenly. The other is a negative shift where the pressure drops abruptly. In the present work, specifically the negative DC-Shift was investigated to analyze the effect of oxidizer flow condition and the resonance between fundamental frequency and other ones, such as Helmholtz frequency, and acoustic frequency. Results show a peak frequency of several hundreds HZ shifts as combustion proceeds. A negative DC-shift was found as the result of phase cancellation between two dominant frequency, combustion frequency and flow related frequency. Still is it required to study further to identify the change of dominance of frequency during the combustion.

Fluid-structure interaction analysis of micromechanical resonance sensor (마이크로기계 공진 센서의 유체-구조물 상호 작용 해석)

  • Kang, In-Goo;Shin, Yoon-Hyuk;Yim, Hong-Jae;Lim, Si-Hyung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.309-313
    • /
    • 2009
  • A micromechanical resonance sensor detects the resonance frequency shift due to mass or adsorption induced surface stress change during molecular adsorption or interaction on its surface. The resonance sensor is surrounded by gas or liquid solution during operation. To study the resonance shift phenomena depending on its surrounding environment, fluid-structure interaction of the resonance sensor has been analyzed for the different fluid environment and boundary conditions using finite element analysis.

  • PDF

T1-Based MR Temperature Monitoring with RF Field Change Correction at 7.0T

  • Kim, Jong-Min;Lee, Chulhyun;Hong, Seong-Dae;Kim, Jeong-Hee;Sun, Kyung;Oh, Chang-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.4
    • /
    • pp.218-228
    • /
    • 2018
  • Purpose: The objective of this study is to determine the effect of physical changes on MR temperature imaging at 7.0T and to examine proton-resonance-frequency related changes of MR phase images and T1 related changes of MR magnitude images, which are obtained for MR thermometry at various magnetic field strengths. Materials and Methods: An MR-compatible capacitive-coupled radio-frequency hyperthermia system was implemented for heating a phantom and swine muscle tissue, which can be used for both 7.0T and 3.0T MRI. To determine the effect of flip angle correction on T1-based MR thermometry, proton resonance frequency, apparent T1, actual flip angle, and T1 images were obtained. For this purpose, three types of imaging sequences are used, namely, T1-weighted fast field echo with variable flip angle method, dual repetition time method, and variable flip angle method with radio-frequency field nonuniformity correction. Results: Signal-to-noise ratio of the proton resonance frequency shift-based temperature images obtained at 7.0T was five-fold higher than that at 3.0T. The T1 value increases with increasing temperature at both 3.0T and 7.0T. However, temperature measurement using apparent T1-based MR thermometry results in bias and error because B1 varies with temperature. After correcting for the effect of B1 changes, our experimental results confirmed that the calculated T1 increases with increasing temperature both at 3.0T and 7.0T. Conclusion: This study suggests that the temperature-induced flip angle variations need to be considered for accurate temperature measurements in T1-based MR thermometry.

Analytical framework for natural frequency shift of monopile-based wind turbines under two-way cyclic loads in sand

  • Yang Wang;Mingxing Zhu;Guoliang Dai;Jiang Xu;Jinbiao Wu
    • Geomechanics and Engineering
    • /
    • v.37 no.2
    • /
    • pp.167-178
    • /
    • 2024
  • The natural frequency shift under cyclic environmental loads is a key issue in the design of monopile-based offshore wind power turbines because of their dynamic sensitivity. Existing evidence reveals that the natural frequency shift of the turbine system in sand is related to the varying foundation stiffness, which is caused by soil deformation around the monopile under cyclic loads. Therefore, it is an urgent need to investigate the effect of soil deformation on the system frequency. In the present paper, three generalized geometric models that can describe soil deformation under two-way cyclic loads are proposed. On this basis, the cycling-induced changes in soil parameters around the monopile are quantified. A theoretical approach considering three-spring foundation stiffness is employed to calculate the natural frequency during cycling. Further, a parametric study is conducted to describe and evaluate the frequency shift characteristics of the system under different conditions of sand relative density, pile slenderness ratio and pile-soil relative stiffness. The results indicate that the frequency shift trends are mainly affected by the pile-soil relative stiffness. Following the relevant conclusions, a design optimization is proposed to avoid resonance of the monopile-based wind turbines during their service life.

Study on the Nonlinear Electromagnetic Acoustic Resonance Method for the Evaluation of Hidden Damage in a Metallic Material (금속 재료의 잠닉손상 평가를 위한 비선형 전자기음향공진 기법에 관한 연구)

  • Cho, Seung-Wan;Cho, Seung-Hyun;Park, Choon-Su;Seo, Dae-Cheol;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.4
    • /
    • pp.277-282
    • /
    • 2014
  • Recently, much attention has been paid to nonlinear ultrasonic technology as a potential tool to assess hidden damages that cannot be detected by conventional ultrasonic testing. One nonlinear ultrasonic technique is measurement of the resonance frequency shift, which is based on the hysteresis of the material elasticity. Sophisticated measurement of resonance frequency is required, because the change in resonance frequency is usually quite small. In this investigation, the nonlinear electromagnetic acoustic resonance (NEMAR) method was employed. The NEMAR method uses noncontact electromagnetic acoustic transducers (EMATs) in order to minimize the effect of the transducer on the frequency response of the object. Aluminum plate specimens that underwent three point bending fatigue were tested with a shear wave EMAT. The hysteretic nonlinear parameter ${\alpha}$, a key indicator of damage, was calculated from the resonance frequency shift at several levels of input voltage. The hysteretic nonlinear parameter of a damaged sample was compared to that of an intact one, showing a difference in the values.

A lower bound analytical estimation of the fundamental lateral frequency down-shift of items subjected to sine testing

  • Nali, Pietro;Calvi, Adriano
    • Advances in aircraft and spacecraft science
    • /
    • v.7 no.1
    • /
    • pp.79-90
    • /
    • 2020
  • The dynamic coupling between shaker and test-article has been investigated by recent research through the so called Virtual Shaker Testing (VST) approach. Basically a VST model includes the mathematical models of the test-item, of the shaker body, of the seismic mass and the facility vibration control algorithm. The subsequent coupled dynamic simulation even if more complex than the classical hard-mounted sine test-prediction, is a closer representation of the reality and is expected to be more accurate. One of the most remarkable benefits of VST is the accurate quantification of the frequency down-shift (with respect to the hard-mounted value), typically affecting the first lateral resonance of heavy test-items, like medium or large size Spacecraft (S/Cs), once mounted on the shaker. In this work, starting from previous successful VST experiences, the parameters having impact on the frequency shift are identified and discussed one by one. A simplified analytical system is thus defined to propose an efficient and effective way of calculating the lower bound frequency shift through a simple equation. Such equation can be useful to correct the S/C lateral natural frequency measured during the test, in order to remove the contribution attributable to the shaker in use. The so-corrected frequency value becomes relevant when verifying the compliance of the S/C w.r.t. the frequency requirement from the Launcher Authority. Moreover, it allows to perform a consistent post-test correlation of the first lateral natural frequency of S/C FE model.