• Title/Summary/Keyword: Resistive Type

Search Result 220, Processing Time 0.026 seconds

Effect of Annealing Conditions on Properties of Ni-Cr Thin Film Resistor (Ni-Cr 박막 저항의 특성에 미치는 열처리 조건의 영향)

  • 류승목;명성재;구본급;강병돈;류제천;김동진
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.11 no.1
    • /
    • pp.37-42
    • /
    • 2004
  • In the electronic components and devices fabrication, thin film resistors with low TCR (temperature coefficient of resistance) and high precision have been used over 3 ㎓ microwave in recent years. Ni-Cr alloys thin films resistors is one of the most commonly used resistive materials because they have low TCR and highly stable resistance. In this work, we fabricated thin film resistors using Evanohm alloys target(72Ni-20Cr-3Al-4Mn-Si) of S-type with excellent resistors properties by RF-sputtering. Also we reported the best annealing condition of thin film resistors for microwave to observe microstructure and electronic properties of thin film according to annealing conditions($200^{\circ}C$, $300^{\circ}C$, $400^{\circ}C$, $500^{\circ}C$)

  • PDF

Effect of Annealing Conditions on Properties of Ni-Cr Thin Film Resistor (Ni-Cr 박막 저항의 특성에 미치는 열처리 조건의 영향)

  • Ryu Sung-Rok;Myung Sung-Jea;Koo Bon-Keup;Kang Beong-Don;Ryu Jei-Chun;Kim Dong-Jin
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2003.11a
    • /
    • pp.145-150
    • /
    • 2003
  • In the electronic components and devices fabrication, thin film resistors with low TCR(temperature coefficient of resistance) and high precision have been used over 3 GHz microwave in recent years. Ni-Cr alloys thin films resistors is one of the most commonly used resistive materials because it has low TCR and highly stable resistance. In this work, we fabricated thin film resistors using Evanohm alloys target(72Ni-20Cr-3Al-4Mn-Si) of s-type with excellent resistors properties by RF-sputtering. Also we reported best annealing conditions of thin film resistors for microwave to observe microstructure and electronic properties of thin film according to annealing conditions$(200^{\circ}C,\;300^{\circ}C,\;400^{\circ}C,\;500^{\circ}C)$.

  • PDF

Design and Fabrication of CMOS Micro Humidity Sensor System (CMOS 마이크로 습도센서 시스템의 설계 및 제작)

  • Lee, Ji-Gong;Lee, Sang-Hoon;Lee, Sung-Pil
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.9 no.2
    • /
    • pp.146-153
    • /
    • 2008
  • Integrated humidity sensor system with two stages operational amplifier has been designed and fabricated by $0.8{\mu}m$ analog mixed CMOS technology. The system (28 pin and $2mm{\times}4mm$) consisted of Wheatstone-bridge type humidity sensor, resistive type humidity sensor, temperature sensors and operational amplifier for signal amplification and process in one chip. The poly-nitride etch stop process has been tried to form the sensing area as well as trench in a standard CMOS process. This modified technique did not affect the CMOS devices in their essential characteristics and gave an allowance to fabricate the system on same chip by standard process. The operational amplifier showed the stable operation so that unity gain bandwidth was more than 5.46 MHz and slew rate was more than 10 V/uS, respectively. The drain current of n-channel humidity sensitive field effect transistor (HUSFET) increased from 0.54 mA to 0.68 mA as the relative humidity increased from 10 to 70 %RH.

  • PDF

Electronic and Magnetic Properties of Ti1-xMxO2-δ (M=Co and Fe) Thin Films Grown by Sol-gel Method

  • Kim, Kwang-Joo;Park, Young-Ran;Ahn, Geun-Young;Kim, Chul-Sung;Park, Jae-Yun
    • Journal of the Korean Magnetics Society
    • /
    • v.15 no.2
    • /
    • pp.109-112
    • /
    • 2005
  • Electronic and magnetic properties of $Ti_{1-x}M_xO_{2-\delta}$ (M=Co and Fe) thin films grown by sol-gel method have been investigated. Anatase and rutile $Ti_{1-x}Co_xO_{2-\delta}$ films were successfully grown on $Al_2O_3$ (0001) substrates and exhibited p-type electrical conductivity while the undoped films n-type conductivity. Room temperature vibrating sample magnetometry measurements on the anatase and rutile $Ti_{1-x}Co_xO_{2-\delta}$ films with same x ($=4.8 at.{\%}$) showed quite similar magnetic hysteresis curves with the saturation magnetic moment of $\~4 {\mu}_B$ per Co ion despite their differences in structural and electronic properties. Such giant magnetic moment is attributable to the unquenched orbital moment of the $Co^{2+}$ ions substituting the octahedral $Ti^{4+}$ sites. Similar ferromagnetic behavior was observed for $Ti_{1-x}Fe_xO_{2-\delta}$ films that are highly resistive compared to the Co doped samples. Saturation magnetic moment was found to decrease for higher x, i.e., $\~2$ and $\~1.5 {\mu}_B$ per Fe ion for x=2.4 and 5.8 at. $\%$, respectively. Conversion electron $M\ddot{o}ssbauer$ spectroscopy measurements predicted the coexistence of $Fe^{2+}$ and $Fe^{3+}$ ions at the octahedral sites of $Ti_{1-x}Fe_xO_{2-\delta}$.

A Development of an Insole Type Local Shear Measurement Transducer and Measurements of Local Plantar Shear Force During Gait (인솔형 국부 전단센서의 개발 및 보행 시 발바닥의 국부 전단력 측정)

  • Jeong Im Sook;Ahn Seung Chan;Yi Jin Bok;Kim Han Sung;Kim Young Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.6 s.171
    • /
    • pp.213-221
    • /
    • 2005
  • An insole type local shear force measurement system was developed and local shear stresses in the foot were measured during level walking. The shear force transducer based on the magneto-resistive principle, was a rigid 3-layer circular disc. Sensor calibrations with a specially designed calibration device showed that it provided relatively linear sensor outputs. Shear transducers were mounted on the locations of four metatarsal heads and heel in the insole. Sensor outputs were amplified, decorded in the bluetooth transmission part and then transferred to PC. In order to evaluate the developed system, both shear and plantar pressure measurements, synchronized with the three-dimensional motion analysis system, were performed on twelve young healthy male subjects, walking at their comfortable speeds. The maximum peak pressure during gait was 5.00kPa/B.W at the heel. The time when large local shear stresses were acted correlated well with the time of fast COP movements. The anteroposterior shear was dominant near the COP trajectory, but the mediolateral shear was noted away from the COP trajectory. The vector sum of shear stresses revealed a strong correlation with COP movement velocity. The present study will be helpful to select the material and to design of foot orthoses and orthopedic shoes for diabetic neuropathy or Hansen disease.

A Study on the Analysis of the Resistance Characteristics and Damage Patterns of Brass Fittings Type CSST (황동이음쇠형 금속플렉시블호스(CSST)의 저항 특성 및 소손 패턴 해석에 관한 연구)

  • Lee, Jang-Woo;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.67-73
    • /
    • 2016
  • This paper examined the structure, fire resistance of brass fittings type CSST employed in gas appliances and the reliability verification. Brass fittings of type CSST consisted of cladding, tubing, nut, clamp ring, socket, and ball valve. The applicable JIA standard regulates the maximum working pressure to be 4.2 kPa, which is the highest pressure of the relevant standards and the KS D 3625 stipulates the maximum pressure to be 3.24 kPa. With a normal product, the average resistance within the confidence interval was found to be $7.36m{\Omega}$. The average resistance within the confidence interval was $6.67m{\Omega}$ after the fire resistance tests. The analysis indicated that the AD was 1.584 and the standard deviation was 0.3972 with respect of a normal product. Compared to the normal product, however, the damaged product after the fire resistance test showed better features, such as an AD of 1.145 and a standard deviation of 0.2467. Moreover, the average resistance of the normal product was $7.359m{\Omega}$ and the standard deviation in histogram analysis was 0.3972. The average resistance of the damaged product after the fire resistance test in the histogram was $6.67m{\Omega}$ and the standard deviation was 0.2467.

Effects of High-frequency Diathermy Integrated into Suboccipital Release on Tenderness and Neck Mobility and Disability in People with Chronic Tension-type Headache (뒤통수밑근 이완기법과 병행된 고주파 심부투열이 만성 긴장성 두통 환자들의 압통과 목 가동성 및 기능장애에 미치는 영향)

  • Lee, Hyoung-ryeol;Shim, Jae-hun;Oh, Duck-won
    • Physical Therapy Korea
    • /
    • v.24 no.2
    • /
    • pp.37-47
    • /
    • 2017
  • Background: Active trigger points (TrPs) of the suboccipital muscles greatly contribute to the occurrence of chronic tension-type headache, with increased sensitivity of TrPs and facilitated referred pain. Objects: This study aimed to investigate whether the integration of high-frequency diathermy into suboccipital release is more beneficial than the use of suboccipital release alone. Methods: Thirty subjects were assigned to either experimental group-1 (EG-1) to undergo suboccipital release combined with high-frequency diathermy (frequency: 0.3 MHz, and electrode type: resistive electronic transfer), or EG-2 to undergo suboccipital release alone, or the control group (CG) with no intervention, with 10 subjects in each group. The assessment tools included the headache impact test 6 (HIT-6), perceived level of tenderness, neck disability index, and neck mobility. Intervention was performed for 10 minutes, twice per week, for 4 weeks, and measurements were performed before and after the interventions. Results: The between-group comparison of the post-test values and changes between pretest and post-test showed significant differences for all parameters at p<.05, except for the left-to-right lateral bending range. In the post hoc test, EG-1 showed significant differences for the parameters in comparison with the CG, while no significant differences in the perceived tenderness level, on both temporal regions, were found between EG-2 and CG. Furthermore, the HIT-6 score and perceived tenderness level, in the right temporal region, showed significant differences between EG-1 and EG-2. In the within-group comparison, EG-1 and EG-2 appeared to be significantly different between pretest and post-test (p<.05), except for the perceived tenderness level in the right temporal region, with significance for the EG-1 group only (p<.05). Conclusion: These findings suggest that the suboccipital release technique may be advantageous to improve headache, tenderness, and neck function and mobility, with more favorable effects with the incorporation of high-frequency diathermy.

A Study on the Resistve Switching Characteristic of Parallel Memristive Circuit of Lithium Ion Based Memristor and Capacitor (리튬 이온 기반 멤리스터 커패시터 병렬 구조의 저항변화 특성 연구)

  • Kang, Seung Hyun;Lee, Hong-Sub
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.28 no.4
    • /
    • pp.41-45
    • /
    • 2021
  • In this study, in order to secure the high reliability of the memristor, we adopted a patterned lithium filament seed layer as the main agent for resistive switching (RS) characteristic on the 30 nm thick ZrO2 thin film at the device manufacturing stage. Lithium filament seed layer with a thickness of 5 nm and an area of 5 ㎛ × 5 ㎛ were formed on the ZrO2 thin film, and various electrode areas were applied to investigate the effect of capacitance on filament type memristive behavior in the parallel memristive circuit of memristor and capacitor. The RS characteristics were measured in the samples before and after 250℃ post-annealing for lithium metal diffusion. In the case of conductive filaments formed by thermal diffusion (post-annealed sample), it was not available to control the filament by applying voltage, and the other hand, the as-deposited sample showed the reversible RS characteristics by the formation and rupture of filaments. Finally, via the comparison of the RS characteristics according to the electrode area, it was confirmed that capacitance is an important factor for the formation and rupture of filaments.

Design of Robust DC-DC Converter by High-Order Approximate 2-Degree-of-Freedom Digital Controller

  • Takegami, E.;Tomioka, S.;Watanabe, K.;Higuchi, K.;Nakano, K.;Kajikawa, T.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.232-237
    • /
    • 2004
  • In many application of DC-DC converters, loads cannot be specified in advance, i.e., their amplitudes are suddenly changed from the zero to the maximum rating. Generally, design conditions are changed for each load and then each controller is re-designed. Then, a so-called robust DC-DC converter which can cover such extensive load changes and also input voltage changes with one controller is needed. Analog control IC is used usually for the controller of DC-DC converter. Simple integral control etc. are performed with the analog control IC. However it is difficult to retain sufficient robustness of DC-DC converter by these techniques. The authors proposed the method of designing an approximate 2-degree-of-freedom (2DOF) controller of DC-AC converter. This controller has an ability to attain sufficient robustness against extensive load and DC power supply changes. For applying this approximate 2DOF controller to DC-DC converter, it is necessary to improve the degree of approximation for better robustness. In this paper, we propose a method of designing good approximate 2DOF digital controller which makes the control bandwidth wider, and at the same time makes a variation of the output voltage very small at a sudden change of resistive load. The proposed good approximate 2DOF digital controller is actually implemented on a DSP and is connected to a DC-DC converter. Experimental studies demonstrate that this type digital controller can satisfy given specifications.

  • PDF

Response Characteristic of the Dual-frame Passive Control System with the Natural Period Difference between the Strength Resistant Core and Frame Structure (강도저항형 코어와 프레임 구조의 진동주기차를 이용한 듀얼프레임 제진시스템의 응답특성)

  • Kim, Tae Kyung;Choi, Kwang Yong;Oh, Sang Hoon;Ryu, Hong Sik
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.19 no.6
    • /
    • pp.273-282
    • /
    • 2015
  • In this study, shaking table test has been carried out for the dual frame passive control system for seismic performance verification of the proposed system. The proposed system was separated into two independent frameworks that are strength resistant core and frame structure by connecting to the damper. Moreover, the seismic performance improvement of the proposed system has been verified by comparing and analyzing the experimental results of the proposed system with an existing core system. As a result of the shaking table test, acceleration and displacement responses of dual-frame vibration control system are decreased than those of the existing strength resistant type core system. In the case of the core system, while the damage was concentrated on the column of first floor, the damage of the dual system was dispersed in each layer. The damage also was concentrated on the damper, almost no damage occurs to the structural members. It has been emphasized that installed dampers in the proposed dual system reduce the input energy of whole structure by absorbing seismic input energy, which leads overall system damage to be reduced.