• Title/Summary/Keyword: Resin crown

Search Result 315, Processing Time 0.022 seconds

TREATMENT OF CROWN-ROOT FRACTURE BY INTENTIONAL REPLANTATION : CASE REPORT (의도적 재식술을 이용한 치관-치근 파절의 치험례)

  • Son, Ju-Hyo;Choi, Hyung-Jun;Sohn, Heung-Kyu
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.2
    • /
    • pp.256-261
    • /
    • 2000
  • Trauma to the tooth is the most common accidents in pediatric dentistry and tooth fracture occurs frequently. Fracture is classified into crown fracture, root fracture, and crown-root fracture which involves both. Also, it is classified into simple or complicated fracture depending on whether the pulp is exposed or not. When the fracture is extended down to the subgingival level following the long axis of the root, or when more than 1/3 of the root is involved, extraction is the primary treatment. But alternative treatment such as extruding the root fragment with orthodontic force and restoring it, or intentionally extracting the tooth and replanting it to a position which it can be restored. This is a case report on intentional replantation of a traumatized maxillary central incisor with crown-root fracture of a patient with mixed dentition. The teeth was extracted and immediate endodontic treatment, retrograde filling and resin restoration were carried out.

  • PDF

FRACTURE STRENGTH OF THE IPS EMPRESS CROWN : THE EFFECTS OF INCISAL REDUCTION AND AXIAL INCLINATION ON UPPER CANINE (IPS Empress 도재관의 파절강도 : 상악 견치에서 절단연 삭제량과 축면 경사도에 따른 영향)

  • Shin Dong-Kuk;Kang Han-Joong;Park Yong-Suck;Park Kwang-Soo;Dong Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.1
    • /
    • pp.30-40
    • /
    • 2005
  • Purpose. The purpose of this study was to compare the fracture strength of the IPS Empress ceramic crown according to the incisal reduction (2.0mm, 2.5mm, 3.0mm) and axial inclination ($4^{\circ}$, $8^{\circ}$, $12^{\circ}$) of the upper canine. Material and methods. After 10 metal dies were made for each group, the IPS Empress ceramic crowns were fabricated and each crown was cemented on each metal die with resin cement. The cemented crowns mounted on the testing jig were inclined 30 degrees and the universal testing machine was used to measure the fracture strength. Results. 1. The fracture strength of the ceramic crown with 3.0mm depth and $12^{\circ}$ inclination was the highest (839N) Crowns of 2.0mm depth and $12^{\circ}$ inclination had the lowest strength (559N). 2. There was no significant difference in the fracture strength by axial inclination in the same incisal reduction group. 3. The fracture mode of the crowns was similar. Most of fracture lines began at the loading area and extended through proximal surface perpendicular to the margin irrespective of incisal reduction.

Rehabilitation using endocrown for fracture of maxillary anterior teeth due to trauma in adolescence: a case report (청소년기 외상으로 인한 상악 전치부 파절 시 Endocrown을 이용한 수복: 증례 보고)

  • So-Yeon Lee;Sung-Ae Son;Jeong-Kil Park
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.40 no.1
    • /
    • pp.24-30
    • /
    • 2024
  • Complicated crown fractures of maxillary anterior teeth caused by trauma in adolescence can cause functional and aesthetic problems. For crown fractures with pulp exposure, various restorative methods can be considered depending on the amount of remaining tooth structure. Direct resin restorations are the most traditional and effective method, but they are likely to discolor and break over time. Fixed prosthesis have a high possibility of re-restoration due to marginal disharmony due to tooth movement during the growth period, and restorations using post which are mainly performed for extensive crown fractures increase the risk of root perforation and root fracture. However, endocrown is an integrated structure that gains retention force from the pulp space, enabling effective reconstruction from a biomechanical perspective and providing advantages in restoring function and aesthetics. Therefore, endocrown can be considered as a restoration method for complicated crown fractures caused by trauma in adolescence.

Resin bonding of metal brackets to glazed zirconia with a porcelain primer

  • Lee, Jung-Hwan;Lee, Milim;Kim, Kyoung-Nam;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.45 no.6
    • /
    • pp.299-307
    • /
    • 2015
  • Objective: The aims of this study were to compare the shear bond strength between orthodontic metal brackets and glazed zirconia using different types of primer before applying resin cement and to determine which primer was more effective. Methods: Zirconia blocks were milled and embedded in acrylic resin and randomly assigned to one of four groups: nonglazed zirconia with sandblasting and zirconia primer (NZ); glazed zirconia with sandblasting, etching, and zirconia primer (GZ); glazed zirconia with sandblasting, etching, and porcelain primer (GP); and glazed zirconia with sandblasting, etching, zirconia primer, and porcelain primer (GZP). A stainless steel metal bracket was bonded to each target surface with resin cement, and all specimens underwent thermal cycling. The shear bond strength of the specimens was measured by a universal testing machine. A scanning electron microscope, three-dimensional optical surface-profiler, and stereoscopic microscope were used to image the zirconia surfaces. The data were analyzed with one-way analyses of variance and the Fisher exact test. Results: Group GZ showed significantly lower shear bond strength than did the other groups. No statistically significant differences were found among groups NZ, GP, and GZP. All specimens in group GZ showed adhesive failure between the zirconia and resin cement. In groups NZ and GP, bonding failed at the interface between the resin cement and bracket base or showed complex adhesive and cohesive failure. Conclusions: Porcelain primer is the more appropriate choice for bonding a metal bracket to the surface of a full-contour glazed zirconia crown with resin cement.

Effect of the type of resin cement on the fracture resistance of chairside CAD-CAM materials after aging

  • Laura Vitoria Rizzatto;Daniel Meneghetti;Marielle Di Domenico;Julia Cadorin Facenda;Katia Raquel Weber;Pedro Henrique Corazza;Marcia Borba
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.3
    • /
    • pp.136-144
    • /
    • 2023
  • PURPOSE. The study objective was to evaluate the influence of the type of resin cement on the flexural strength and load to fracture of two chairside CADCAM materials after aging. MATERIALS AND METHODS. A polymer-infiltrated ceramic network (PICN) and a nanoceramic resin (RNC) were used to produce the specimens. Two types of dual-cure resin cements, a self-adhesive and a universal, were investigated. Bilayer specimens were produced (n = 10) and aged for 6 months in a humid environment before the biaxial flexural strength test (σf). Bonded specimens were subjected to a mechanical aging protocol (50 N, 2 Hz, 37℃ water, 500,000 cycles) before the compressive load test (Lf). σf and Lf data were analyzed using two-way ANOVA and Tukey tests (α = .05). Chi-square test was used to analyze the relationship between failure mode and experimental group (α = .05). RESULTS. The type of resin cement and the interaction between factors had no effect on the σf and Lf of the specimens, while the type of restorative material was significant. RNC had higher σf and Lf than PICN. There was a significant association among the type of cracks identified for specimens tested in Lf and the restorative material. CONCLUSION. The type of resin cement had no effect on the flexural strength and load to fracture of the two investigated CAD-CAM chairside materials after aging.

Development of Surface-mount-type Crown-shaped Lens for Reducing Glare Effect of Light-emitting Diode Light Source (LED 광원의 눈부심 현상을 감소시키기 위한 표면 실장형 CR 렌즈 개발)

  • Park, Yong Min;Bang, Hyun Chul;Seo, Young Ho;Kim, Byeong Hee
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.1
    • /
    • pp.64-68
    • /
    • 2014
  • This paper introduces the use of a crown-shaped (CR) lens to effectively diffuse the light from a light-emitting diode (LED) without any loss in the light intensity, in contrast to polymer-bulb-type diffusers. The diffusion lens was designed based on the Snell's law, which describes the physical path of a ray passing through the boundary between different media. CR lenses were fabricated by polydimethylsiloxane (PDMS) casting and UV-embossing processes, which used a pre-designed metal mold and UV-curable resin, respectively. Through experiments and optical evaluations, it was verified that the newly proposed CR lens not only decreased the vertical light strength and glare effect from an LED light source but also improved the diffusion characteristics while maintaining the quality of the LED's light intensity.

A Study on the Adaptability and Cytotoxicity of Porcelain Bonded Ni-Cr Alloy (도재소부용 Ni-Cr합금의 적합성과 세포독성에 관한 연구)

  • Choi, Boo-Byung;Shin, Myung-Chull
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.20 no.1
    • /
    • pp.7-17
    • /
    • 1982
  • In order to investigate the internal adaptability and cytotoxicity for porcelain fused to metal Ni-Cr alloy, two commercial alloys (Generic Gold-R alloy, Aalba Dent- Valloy)were employed and compared with new developed beryllium free Ni-Cr alloy (KIST-K alloy). After cementation of each crown to abutment die before and after ceramic bonding respectively, dies were mounted to epoxy resin and the internal space was measured between crown and die of each point on sagittal section. The results were as follows: 1) The results show that the space between the crown and the die was largest at the incisal edge, followed by the shoulder or the bevel and chamfer. The least was to be in the axial surface. 2) There were no significant difference in the adaptability of the compared alloys. 3) On day 2 of the experiment the cell multiplication was slightly inhibited by R and K alloys. However, observations taken at day 4 and 7 showed normal cell multiplication process compared to control group. 4) Alloy V exhibited the most severe cell toxicity among the alloys tested on day 2. By day 4 and 7 it showed a decrease level in toxicity, however it did not exhibit normal cell growth as compared to control group.

  • PDF

FITNESS OF THE COLLARLESS METAL-CERAMIC RESTORATIONS AT LABIAL MARGINS: A SCANNING ELECTRON MICROSCOPE STUDY (도재전장주조관의 순측 치경부 변연 적합도에 관한 주사전자현미경적 연구)

  • Kim, Young-Han;Lee, Sun-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.23 no.1
    • /
    • pp.113-123
    • /
    • 1985
  • The purpose of this study was to evaluate the marginal fitness of collarless metal-ceramic crown formed with direct lift technique using wax compared with metal-ceramic crown with metal butt margin. Twenty crowns, ten were collarless metal-ceramic crowns and ten were metal-ceramic crowns with metal butt margins, were made and cemented on epoxy resin dies, and their marginal openings were measured on scanning electron microphotographic prints at x200 magnification. The results were as follows; 1. In the case of collarless metal-ceramic crowns, the mean marginal opeining was $43.78{\pm}17.67{\mu}m$, the mean maximum marginal opening was $52.81{\pm}19.81{\mu}m$, and the mean minimum marginal opening was $34.99{\pm}16.58{\mu}m$. 2. In the case of metal-ceramic crowns with metal butt margins, the mean marginal opening was $47.62{\pm}25.55{\mu}m$, the mean maximum marginal opening was $61.90{\pm}24.39{\mu}m$, and the mean minimum marginal opening was $34.86{\pm}24.92{\mu}m$. 3. There was no significant difference between two types of crowns at the 99% confidence level. 4. The marginal fitness of collarless metal-ceramic crown formed with direct lift technique using wax was clinically acceptable.

  • PDF

Crown Shape Control of Pinus koraiensis S et. Z. (III) - Crown Shape Types for Seed and Timber Production from the Trees under Age Class III - (잣나무의 수형(樹型) 조절(調節) (III) - III영급(齡級) 이하(以下) 인공림(人工林)에서 잣과 목재(木材) 생산(生産)을 위한 수형(樹型) -)

  • Yi, Jae-Seon;Song, Jeong-Ho;Park, Moon-Han;Han, Sang-Urk
    • Journal of Korean Society of Forest Science
    • /
    • v.88 no.2
    • /
    • pp.195-204
    • /
    • 1999
  • To improve nut production and timber quality in a plantation, crown shape controls were suggested for Korean white pines (Pinus koraiensis) under age class III through the analyses of the crown shape controls for seed orchard trees in several species, of crown status of controlled and uncontrolled trees in a Korean white pine seed orchard, and of growth characteristics of plantation trees under age class III. For nut production from the small trees less than 8 m, modified leader type can be applied by cutting the central leader and all branches below 1 m and keeping 4~5 nodes with 3~4 whorled branches a node locating 1 m apart. Trees with a 4~8 m long trunk below the first living branch are shaped into trees for nut and timber production, which have a 4~8 m long knotless stem and a modified leader type crown with 4~5 nodes with 3~4 whorled branches a node at a distance of 1 m. Trees, showing the first living branch at or above 9 m from the surface, are pruned severely for timber production and result in a central leader type containing two fifths of the initial crown. It is advisable to remove the leader and the branches when collecting cones or after/during October to take advantage of easy labor and little resin while cutting. After stem cut, branches showing apical dominance are to be cut to control height when necessary. The removal of the uppermost node may be needed to control the crown shape several years after the initial stem-cut.

  • PDF

Comparison of apical transportation and change of working length in K3, NRT AND PROFILE rotary instruments using transparent resin block (Transparent resin block을 이용한 K3, NRT, PROFILE의 apical transportation 및 working length 변화양상의 비교)

  • Yoon, Min-Jung;Song, Min-Ju;Shin, Su-Jung;Kim, Eui-Seong
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.1
    • /
    • pp.59-65
    • /
    • 2011
  • Objectives: The purpose of this study is to compare the apical transportation and working length change in curved root canals created in resin blocks, using 3 geometrically different types of Ni-Ti files, K3, NRT, and Profile. Materials and Methods: The curvature of 30 resin blocks was measured by Schneider technique and each groups of Ni-Ti files were allocated with 10 resin blocks at random. The canals were shaped with Ni-Ti files by Crown-down technique. It was analyzed by Double radiograph superimposition method (Backman CA 1992), and for the accuracy and consistency, specially designed jig, digital X-ray, and CAD/CAM software for measurement of apical transportation were used. The amount of apical transportation was measured at 0, 1, 3, 5 mm from 'apical foramen - 0.5 mm' area, and the alteration of the working length before and after canal shaping was also measured. For statistics, Kruskal-Wallis One Way Analysis was used. Results: There was no significant difference between the groups in the amount of working length change and apical transportation at 0, 1, and 3 mm area (p = 0.027), however, the amount of apical transportation at 5 mm area showed significant difference between K3 and Profile system (p = 0.924). Conclusions: As a result of this study, the 3 geometrically different Ni-Ti files showed no significant difference in apical transportation and working length change and maintained the original root canal shape.