• Title/Summary/Keyword: Residual Test

Search Result 1,822, Processing Time 0.03 seconds

Implementation of Dedicated Power Line Filter for HEMP Protection (HEMP 보호용 전원선 필터 구현)

  • Kim, Keun-Nam;Lee, Sung-Hwa;Kim, Jin-Tae
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.4
    • /
    • pp.47-52
    • /
    • 2016
  • This paper covers the importance of a dedicated Power Line Filter implementation against HEMP(High altitude ElectroMagnetic Pulse) threats caused by high altitude nuclear detonations. As the PCI test results for E1 short pulse with 2500[A], only HEMP filter obtained the required residual current around 8[A], but others didn't meet below 10[A] on MIL-STD-188-125 PCI regulation. Consequently, the development of a dedicated power line filter turned out to be a essential element in order to protect the power related system against HEMP transient.

Hydro-mechanical behavior of compacted silt over a wide suction range

  • Chen, Bo;Ding, Xiuheng;Gao, You;Sun, De'an;Yu, Haihao
    • Geomechanics and Engineering
    • /
    • v.22 no.3
    • /
    • pp.237-244
    • /
    • 2020
  • To achieve a wide suction range, the low suction was imposed on compacted silt specimens by the axis translation technique and the high suction was imposed by the vapor equilibrium technique with saturated salt solutions. Firstly, the results of soil water retention tests on compacted silt show that the soil water retention curves in terms of gravimetric water content versus suction relation are independent of the dry density or void ratio in a high suction range. Therefore, triaxial tests on compacted silt with constant water content at high suctions can be considered as that with constant suction. Secondly, the results of triaxial shear tests on unsaturated compacted silt with the initial void ratio of about 0.75 show a strain-hardening behavior with a slightly shear contraction and then strain-softening behavior with an obviously dilation. As the imposed suction increases, the shear strength increases up to a peak value and then decreases when the suction is beyond a special value corresponding to the peak shear strength. The residual strength increases to fair value and those at high suctions are almost independent of imposed suctions. In addition, the contribution of suction to the strength of compacted silt would not diminish even in a high suction range.

Mixed-effects model by projections (사영에 의한 혼합효과모형)

  • Choi, Jaesung
    • The Korean Journal of Applied Statistics
    • /
    • v.29 no.7
    • /
    • pp.1155-1163
    • /
    • 2016
  • This paper deals with an estimation procedure of variance components in a mixed effects model by projections. Projections are used to obtain sums of squares instead of using reductions in sums of squares due to fitting both the assumed model and sub-models in the fitting constants method. A projection matrix can be obtained for the residual model at each step by a stepwise procedure to test the hypotheses. A weighted least squares method is used for the estimation of fixed effects. Satterthwaite's approximation is done for the confidence intervals for variance components.

Life cycle cost analysis and smart operation mode of ground source heat pump system

  • Yoon, Seok;Lee, Seung-Rae
    • Smart Structures and Systems
    • /
    • v.16 no.4
    • /
    • pp.743-758
    • /
    • 2015
  • This paper presents an advanced life cycle cost (LCC) analysis of a ground source heat pump (GSHP) system and suggests a smart operation mode with a thermal performance test (TPT) and an energy pile system constructed on the site of the Incheon International Airport (IIA). First, an economic analysis of the GSHP system was conducted for the second passenger terminal of the IIA considering actual influencing factors such as government support and the residual value of the equipment. The analysis results showed that the economic efficiency of the GSHP system could be increased owing to several influential factors. Second, a multiple regression analysis was conducted using different independent variables in order to analyze the influence indices with regard to the LCC results. Every independent index, in this case the initial construction cost, lifespan of the equipment, discount rate and the amount of price inflation can affect the LCC results. Third, a GSHP system using an energy pile was installed on the site of the construction laboratory institute of the IIA. TPTs of W-shape and spiral-coil-type GHEs were conducted in continuous and intermittent operation modes, respectively, prior to system operation of the energy pile. A cooling GSHP system in the energy pile was operated in both the continuous and intermittent modes, and the LCC was calculated. Furthermore, the smart operation mode and LCC were analyzed considering the application of a thermal storage tank.

Evaluating the Effect of Specimen Thickness on Fatigue Crack Growth in AZ31 Alloy Using ANOVA (분산분석법을 이용한 AZ31 합금의 피로균열성장에 미치는 시편두께 효과 평가)

  • Choi, Seon Soon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.6
    • /
    • pp.9-16
    • /
    • 2020
  • This study aims to assess the effects of specimen thickness (ST) on fatigue crack growth in the early stages of crack propagation and near failure in magnesium alloys. The analysis of variance (ANOVA) method was adopted because fatigue crack propagation in magnesium alloys exhibits statistical behavior. The equality of variance test and residual diagnostics were performed on the grown cracks to confirm the validity of ANOVA by verifying the normal distribution and mutual independence of the residuals and their homoscedasticity. ANOVA confirmed that ST heavily impacts crack growth; i.e., when ST is smaller, cracks grow faster in the early crack propagation stage and break more quickly before the formation of larger cracks. We found that ST significantly affects fatigue crack growth in the early crack propagation stage and near the failure stage in magnesium alloys. The regression model was also used to predict crack formation near the failure stage.

Removal Characteristics of Arsenic from Abandoned Metal Mining Tailings by Electrokinetic Technique (동전기법에 의한 폐 중금속광산 퇴적토 내의 비소제거 특성)

  • Shin Hyun-Moo;Yoon Sam-Seok
    • Journal of Environmental Science International
    • /
    • v.15 no.3
    • /
    • pp.279-286
    • /
    • 2006
  • Electrokinetic technique was considered in removing arsenic from the abandoned mining tails. In order to estimate the removal characteristics of arsenic, the sequential extraction analysis and desorption experiment were carried out prior to the application of electrokientic process. The result of sequential extraction analysis indicated that the water soluble and exchangeable fraction, easily leachable to ground water, were very low as much as about 2.5% and the fraction except residual (38.3%), possibly extractable under very acidic or alkalic environment, was about 59%. In the result of desorption test using four different kinds of electrolytes, the mixture of citric acid and sodium dodecyl sulfate (SDS) showed the highest desorption efficiency as much as 77.3%. The removal efficiencies of arsenic from mining tailings by electrokinetic process under the different electrolyte environments were slightly low and resulted in the following order: citric acid + SDS (18.6%) > 0.1 $NHNO_3$ (8.1%) > HAc (7.4%) > Distilled water(6.6%). Also, arsenic in soil matrix was moved favorably in the direction of anodic rather than cathodic region, which is opposite trend with cationic metal ions generally existing in soil, because anionic form of arsenic is dominated in acidic soil caused by the movement of acid front form anode.

Impact Damage of Honeycomb Sandwich Antenna Structures (통신 안테나용 허니콤 샌드위치 구조물의 충격 손상에 관한 연구)

  • 조성재;김차겸;박현철;황운봉
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2001.05a
    • /
    • pp.74-77
    • /
    • 2001
  • The impact response and damage of CLAS panel was investigated experimentally. The facesheet material used was RO4003 woven-glass hydrocarbon/ceramic and the core material was Nomex honeycomb with a cell size of 3.2mm and a density of 96 kg/$\textrm{m}^{3}$. The shield plane used was RO4003 and 2024-T3 aluminum. Static indentation and impact test was conducted to characterize the type and extent of the damage observed in two CLAS panels, and the performance of antenna used in a wireless LAN system. Correlation of peak contact force, residual indentation and the delamination area shows impact damage of the panel with an aluminum shield plane is larger than that of the panel with RO4003 shield plane, although tile former is more penetration resistant. The damage was observed by naked eye, ultrasonic inspection and cross sectioning. The shape and size of delamination was estimated by ultrasonic inspection, and the area of delamination linearly increases as impact energy increases. The performance of impact damaged antenna was estimated by measuring return loss and radiation pattern.

  • PDF

A Study on the Performance Test and Manufacture of the Dielectric Sensor for the Cure Monitoring of the High Temperature Composites (고온 복합재료의 경화 모니터링을 위한 고온 유전센서의 제작 및 성능평가에 관한 연구)

  • 김일영;최진호;이대길
    • Composites Research
    • /
    • v.14 no.1
    • /
    • pp.30-38
    • /
    • 2001
  • As fiber reinforced composite materials are widely used in aircraft, space structures and robot arms, the on-line cure monitoring during the cure process of the composite materials has become an important research area for the better quality and productivity. In this paper, the dielectric circuit of the Wheatstone bridge type for measuring the dissipation factor during cure of thermsetting resin matrix composite materials was designed and manufactured. Also, the dielectric sensor for the cure monitoring of high temperature cure composites was developed and tested. The residual thermal stresses of the dielectric sensor during high temperature cure were analyzed by the finite element method and its dielectric characteristics at high temperature cure were analyzed by the finite element method and its dielectric characteristics at high temperature were evaluated. The on-line cure monitoring of the BMI(Bismaleimide) resin was performed using the developed Wheatstone bridge type circuit and the high-temperature dielectric sensor.

  • PDF

An Experimental Study on the Effect of Corrosion Protection by Tighting Concrete Used Fly-ash and Silica Fume (Part2, In the case of Steel Bar s Corrosion) (콘크리트 밀실화에 의한 염해대책 및 방청효과에 관한 실험적 연구 (제2보, 철근의 부식 현황을 중심으로))

  • 이상수;김진만;남상일;김문한;김무한
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1994.04a
    • /
    • pp.148-151
    • /
    • 1994
  • Up to now, sea sand without complete removal of salt is being used in the construction works because there is little satisfactory counterplan for the substitute aggregate. In the case that such sea sand is used in the reinforced concrete, the residual salt gives rise to deterioration phenmenon and iron corrosion, reducing durability of the ferro-concrete structures. The paper, an experimental study on the effect of corrosion protection by tighting concrete used SF and FA, is to investigate general steel bar's corrosion and to develop concrete using sea sand economically after it is analyzed and examinated ratio of the corrosion area affected by the autoclave cycle. As a test results, as for corrosion area ratio, it is very effective to use admixrutes such as SF and FA which decrease corrosion area remarkably with increasing the amounts of admixtures. Accordingly the use of admixtures is advantageous for tightening concrete and has an effect of salt damage prevention and rust protection in concrete used sea sand.

  • PDF

A Study on the Shot Peening on the Low Temperature Fatigue Crack Propagation (쇼트피이닝 가공된 스프링강의 저온 피로균열진전 평가)

  • 박경동;정찬기;하경준;박상오;손명군;노영석
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2001.10a
    • /
    • pp.282-286
    • /
    • 2001
  • In this study, CT specimens were prepared from spring steel(SUP9) processed shot peening which was room temperature, low temperature and high temperature experiment. And we got the following characteristics from fatigue crack growth test carried out in the environment of room, low temperature and high temperature at $25^{\circ}C$,$-30^{\circ}C$,$-50^{\circ}C$,$-70^{\circ}C$ and $-100^{\circ}C$ in the range of stress ratio of 0.05 by means of opening mode displacement. The threshold stress intensity factor range $\Delta K_{th}$ in the early stage of fatigue crack growth (Region I ) and stress intensity factor range $\Delta K$ in the stable of fatigue crack growth (Region II) was decreased in proportion to descend temperature. It assumed that the fatigue resistance characteristics and fracture strength at low temperature and high temperature is considerable higher than that of room temperature in the early stage and stable of fatigue crack growth region.

  • PDF