Acknowledgement
Supported by : National Research Foundation of Korea
References
- An, E.Y., Kim, S.Y. and Song, Y.H. (2005), "Cost-benefit analysis of the geothermal energy resources on the private and public respects", J. Korean Soc. Mineral and Energy Resource Eng., 42(4), 318-329. (in Korean)
- Anthony, J.H. (2007), Probability and Statistics for Engineers and Scientists, 3rd Ed., Thomson Brooks/Cole.
- Bennazza, A., Blanco, E., Aichouba, M, Rio, J.L. and Laouedj, S. (2011), "Numerical investigation of horizontal ground coupled heat exchanger", Energy Procedia, 6, 29-35. https://doi.org/10.1016/j.egypro.2011.05.004
- Brandl. H. (2006), "Energy foundations and other thermo-active ground structures", Geotechnique, 56, 81-122. https://doi.org/10.1680/geot.2006.56.2.81
- Chong, C.S.A., Gan, G., Verhoef, A., Garcia, R.G. and Vidale, P.L. (2013), "Simulation of thermal performance of horizontal slinky-loop heat exchangers for ground heat pump", Appl. Energy, 104, 603-610. https://doi.org/10.1016/j.apenergy.2012.11.069
- Cui, P., Li, X., Man, Y. and Fang, Z. (2011), "Heat transfer analysis of pile geothermal heat exchangers with spiral coils", Appl. Energy, 88(11), 4113-4119. https://doi.org/10.1016/j.apenergy.2011.03.045
- Demir, H., Koyun, A. and Temir, G. (2009), "Heat transfer of horizontal parallel pipe ground heat exchanger and experimental verification", Appl. Therm. Eng., 29, 224-233. https://doi.org/10.1016/j.applthermaleng.2008.02.027
- Dhillon, B.S. (2009), Life cycle costing for engineers, CRC Press Taylor & Francis Group.
- Florides, G. and Kalogirou, S. (2008), "First in situ determination of the thermal performance of a U-pipe borehole heat exchanger in Cyprus", Appl. Therm. Eng., 28, 157-163. https://doi.org/10.1016/j.applthermaleng.2007.03.026
- Gao, J., Zhang, X., Liu, J., Li, K. and Yang, J. (2008), "Numerical and experimental assessment of thermal performance of vertical energy piles: an application", Appl. Energy, 85(10), 901-910. https://doi.org/10.1016/j.apenergy.2008.02.010
- Go, G.H., Lee, S.R., Yoon, S. and Kang, H.B. (2014), "Design of spiral coil PHC energy pile considering effective borehole thermal resistance and groundwater advection effects", Appl. Energy, 125, 165-178. https://doi.org/10.1016/j.apenergy.2014.03.059
- Incheon International Airport. (2010), "Report of application analysis for renewable energy". (in Korean)
- Johnston, I.W, Narsilio, G.A. and Colls, S. (2011), "Emerging geothermal energy technologies", KSCE Journal of Civ Engrs., 15(4), 643-653. https://doi.org/10.1007/s12205-011-0005-7
- Lee, C.K. (2011), "Effects of multiple ground layers on thermal response test analysis and ground-source heat pump simulation", Appl. Energy, 88, 4405-4410. https://doi.org/10.1016/j.apenergy.2011.05.023
- Lee, C.H., Park, M.S., Nguyen, T.B., Shon, B., Choi, J.M. and Choi, H.S. (2012), "Performance evaluation of closed-loop vertical ground heat exchangers by conducting in-situ thermal response tests", Renew. Energ., 42, 77-83. https://doi.org/10.1016/j.renene.2011.09.013
- Lee, J.W., Kim, T. and Leigh, S.B. (2012), "Performance evaluation of ground source heat pump system utilizing energy pile in apartment", J. Korean Institute of Ecological Architecture and Environ., 12(4), 41-46. (in Korean)
- Lee, S.R., Yoon, S., Go, G.H., Kang, H.B. and Park, D.W. (2013), "Evaluation of heat exchange rate for different types of ground heat exchangers", Proceeding of the 23rd International Ocean and Polar Engineering Conference, Alaska, USA.
- Loveridge, F. and Powrie, W. (2014), "2D thermal resistance of pile heat exchangers", Geothermics, 50, 122-135. https://doi.org/10.1016/j.geothermics.2013.09.015
- Park, H., Lee, S.R., Yoon, S., Shin, H.S. and Lee, D.S. (2012), "Case study of heat transfer behavior of helical ground heat exchanger", Energy. Build., 53, 137-144. https://doi.org/10.1016/j.enbuild.2012.06.019
- Park, H, Lee, S.R., Yoon, S. and Choi, J.C. (2013), "Evaluation of thermal response and performance of PHC energy pile: Field experiments and numerical simulation", Appl. Energy, 103, 12-24. https://doi.org/10.1016/j.apenergy.2012.10.012
- Roth, P., Georgiev, A., Busso, A. and Barraza, E. (2004), "First in situ determination of ground and borehole thermal properties in Latin America", Renew. Energ., 29(12), 1947-1963. https://doi.org/10.1016/j.renene.2004.02.014
- Tarnawski, V.R., Leong, W.H., Momose, T. and Hamade, Y. (2009), "Analysis of ground source heat pumps with horizontal ground heat exchangers for northern Japan", Renew. Energ., 34, 127-134. https://doi.org/10.1016/j.renene.2008.03.026
- Vu, B.N. (2013), Life cycle cost analysis of ground-coupled heat pump systems including several types of heat exchangers, Master Thesis, KAIST.
- Yoon, S., Lee, S.R., Go, G.H., Jianfeng, X., Park, H. and Park, D. (2014a), "Thermal transfer behavior in two types of W-shape ground heat exchangers installed in multilayer soils", Geomech. Eng., 6(1), 79-98. https://doi.org/10.12989/gae.2014.6.1.079
- Yoon, S. (2014b), Suggestion of design parameters and evaluation of thermal efficiency in energy piles by thermal performance tests, Ph.D. Thesis, KAIST.
- Zhang, C., Guo, Z., Liu, Y., Cong, X. and Peng, D. (2014), "A review on thermal response test of ground-coupled heat pump systems", Renew. Sust.. Energ.Rev., 40, 851-867. https://doi.org/10.1016/j.rser.2014.08.018
Cited by
- Hybrid thermal seasonal storage and solar assisted geothermal heat pump systems for greenhouses vol.4, pp.1, 2016, https://doi.org/10.12989/eri.2016.4.1.087
- Evaluation of stainless steel pipe performance as a ground heat exchanger in ground-source heat-pump system vol.113, 2016, https://doi.org/10.1016/j.energy.2016.07.057
- Evaluation of polyethylene and steel heat exchangers of ground source heat pump systems based on seasonal performance comparison and life cycle assessment vol.162, 2018, https://doi.org/10.1016/j.enbuild.2017.12.037