• 제목/요약/키워드: Reset switch

검색결과 32건 처리시간 0.028초

Low Cost Driving System for Plasma Display Panels by Eliminating Path Switches and Merging Power Switches

  • Lee, Dong-Myung;Hyun, Dong-Seok
    • Journal of Power Electronics
    • /
    • 제7권4호
    • /
    • pp.278-285
    • /
    • 2007
  • Recently, plasma display panels (PDP) have become the most promising candidate in the market for large screen size flat panel displays. PDPs have many merits such as a fast display response time and wide viewing angle. However, there are still concerns about high cost because they require complex driving circuits composed of high power switching devices to generate various voltage waveforms for three operational modes of reset, scan, and sustain. Conventional PDP driving circuits use path switches for voltage separation and a scan switch to offer a scan voltage for reset and scan operations, respectively. In addition, there exist reset switches to initialize PDPs by regulating the wall charge conditions with ramp shaped pulses, which means the necessity of specific power devices for the reset operation. Because power for the plasma discharge accompanied by a large current is transferred to a panel via path switches, high power rating switches are used for path switches. Therefore, this paper proposes a novel low-cost PDP driving scheme achieved by not only eliminating path switches but also merging the function of reset switches into other switches used for sustain or scan operations. The simulated voltage waveforms of the proposed topology and experimental results implemented in a 42-inch panel to demonstrate the validity of using a new gate driver that merges the functions of power switches are presented.

전력선 통신을 이용한 풀 코드 스위치의 동작위치 인식 시스템에 대한 연구 (A Study on Operating Position Sensing System of Pull Cord Switches Using Power Line Communication)

  • 최남섭;이범
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2003년도 추계종합학술대회
    • /
    • pp.745-748
    • /
    • 2003
  • 본 논문에서는 각종 산업 현장의 라인에 긴급 정지 장치로 병설되는 풀 코드 스위치의 동작위치를 판별하는 시스템에 대하여 다룬다. 특히, 된 논문에서는 전력선 통신 기술을 사용하여 복잡한 케이블 포설 없이도 기존의 2선만을 사용하여 동작된 풀 코드 스위치의 위치를 인식하는 방법을 제시한다. 또한 전력선 통신 IC의 제어 기능을 사용하여 스위치 제어 인식장치에서 각 스위치를 리셋하는 신호를 전송할 수 있도록 구성한다. 끝으로, 논문에서는 제안된 전력선 방식의 풀 코드 스위치 동작위치 인식장치를 제작하고 전력선을 통하여 전달된 신호 및 반응시간 관찰함으로써 풀 코드 스위치의 위치인식 시스템으로 실제로 적용이 가능함을 확인하였다.

  • PDF

보조 스위치를 사용한 ZVS Two-Switch 포워드 컨버터에 대한 연구 (A Study of ZVS Two-Switch Forward Converter Using Auxiliary Switch)

  • 정민혁;김용;엄태민;이규훈;이동현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.965_966
    • /
    • 2009
  • In this paper, a new soft-switching Two-switch Forward converter topology has been proposed. Compared with conventional two-switch forward converter, the proposed converter employs an auxiliary switch and a clamp capacitor to instead of two reset diodes, not only its duty cycle can exceed 0.5 to achieve wide range input voltage, but also soft switching can be achieved for all switches. Especially, voltage stress across main switches can be clamped at $1/2V_{in}$, voltage stress across auxiliary switch can be clamped at $V_{in}$. In addition, due to clamp capacitor series with the transformer, duty ratio can be extended with equation $V_o=\frac{V_{in}(1-D}D{N}$. Therefore, as a kind of better cost-effective approach, it is very attractive for high input, wide range and high efficiency application.

  • PDF

리셋 권선을 사용하지 않는 새로운 형태의 영전류 천이형 포워드 컨버터 (A New Zero-Current-Transition Forward Converter without Reset Turn)

  • 백은성;최현칠
    • 전력전자학회논문지
    • /
    • 제27권6호
    • /
    • pp.464-470
    • /
    • 2022
  • A new type of soft-switching forward converter is proposed in this study. By adding only a few components, the inductor, diode, switch, and capacitor exhibit higher efficiency than the conventional forward converter. Therefore, the switching losses of the proposed forward converter are considerably reduced compared with those of the conventional forward converter. In addition, the reset winding is not used because of the capacitor employed in the auxiliary circuit. The auxiliary capacitor is adopted for zero-current-transition operation and for dissipating magnetization energy. The performance of the proposed forward converter is validated using experimental results from a 60 W, single-output, forward converter prototype, and design guidelines are presented.

광 네트워크 스위치 응용을 위한 RSFQ Switch의 회로 설계 및 시뮬레이션 (Circuit Design and Simulation Study of an RSFQ Switch Element for Optical Network Switch Applications)

  • 홍희송;정구락;박종혁;임해용;장영록;강준희;한택상
    • Progress in Superconductivity
    • /
    • 제5권1호
    • /
    • pp.13-16
    • /
    • 2003
  • In this work, we have studied about an RSFQ (Rapid Single Flux Quantum) switch element. The circuit was designed, simulated, and laid out for mask fabrication. The switch cell was composed of a D flip-flop, a splitter, a confluence buffer, and a switch core. The switch core determined if the input data could pass to the output. “On” and o“off” controls in the switch core could be possible by utilizing an RS flip-flop. When a control pulse was input to the “on” port, the RS flip-flop was in the set state and passed the input pulses to the output port. When a pulse was input to the “off” port, the RS flip-flop was in the reset state and prevented the input pulses from transferring to the output port. We simulated and optimized the switch element circuit by using Xic, WRspice, and Julia. The minimum circuit margins in simulations were more than $\pm$20%. We also performed the mask layout of the circuit by using Xic and Lmeter.

  • PDF

Three-Switch Active-Clamp Forward Converter with Low Voltage Stress

  • Park, Ki-Bum;Kim, Chong-Eun;Moon, Gun-Woo;Youn, Myung-Joong
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.505-507
    • /
    • 2008
  • A conventional active-clamp forward (ACF) converter is a favorable candidate in low-to-medium power applications. However, the switches suffer from high voltage stress, i.e., sum of the input voltage and the reset capacitor voltage. Therefore, it is not suitable for high input voltage applications such as a front-end converter of which the input voltage is about 400-$V_{dc}$. To solve this problem, three-switch ACF (TS-ACF) converter, which employs two main switches and one auxiliary switch with low voltage stress, is proposed. Utilizing low-voltage rated switches, the proposed converter is promising for high input voltage applications with high efficiency and low cost.

  • PDF

자기스위치 시스템의 파라메다 최적화 및 출력 안정화에 관한 연구 (A Study on parameter optimization and output stabilization of Magnetic Switch System.)

  • 전상영;이주희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 하계종합학술대회 논문집
    • /
    • pp.637-641
    • /
    • 1989
  • We have developed 3-stage of Magnetic Switch System based on the nonlinearities of ferromagnetic material used in the saturable inductor, and made experiment of parameter optimization and output stabilization of Magnetic Switch System. The cross-section and conductor burns of each satarable inductor were optimized 30 $cm^2$ 19.25 $cm^2$ 5, and 25 $cm^2$ 2, respectively. With this condition, 6.2 us [FWHM], 96 A pulse at first stage was compressed into 0.4 us[FWHM], 1.61 kA pulse at last stage. The current gain and compression ratio were 16.8, 17, respectively. ln addition, System output was stabilized with reset current of 6 A, 200 us.

  • PDF

변압기 전압 되먹임방식을 이용한 고역률의 리셋권선을 갖는 새로운 포워드 컨버터 (Novel Reset Winding Clamped Forward Converter with Transformer Voltage Feedback Technique for Power Factor Correction)

  • 문건우;노정욱;정영석;이준영;윤명중
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.348-350
    • /
    • 1996
  • A new reset winding clamped forward converter with transformer voltage feedback technique for power factor correction with a single-switch/single-stage is proposed. The proposed converter gives the good power factor correction, low current harmonic distortions, and tight output voltage regulation. The prototype shows the IEC555-2 requirements are met satisfactorily with nearly unity power factor.

  • PDF

A Forward-Integrated Buck DC-DC Converter with Low Voltage Stress for High Step-Down Applications

  • Adivi, Maedeh Ghanbari;Yazdani, Mohammad Rouhollah
    • Journal of Power Electronics
    • /
    • 제18권2호
    • /
    • pp.356-363
    • /
    • 2018
  • The combination of a buck converter and a forward converter can be considered to accomplish a high step-down non-isolated converter. To decrease the insufficient step-down ratio of a regular buck converter and to distribute switch voltage stress, a forward-integrated buck (FIB) converter is proposed in this paper. The proposed interleaved DC-DC converter provides an additional step-down gain with the help of a forward converter. In addition to its simple structure, the transformer flux reset problem is solved and an additional magnetic core reset winding is not required. The operational principle and an analysis of the proposed FIB converter are presented and verified by experimental results obtained with a 240 W, 150 V/24 V prototype.

성인의 제2 언어 습득에 있어서 매개변수 재고정 (Parameter resetting in adult second language acquisition)

  • 김학수
    • 영어어문교육
    • /
    • 제5호
    • /
    • pp.219-247
    • /
    • 1999
  • The purpose of this paper is to examine how Korean learners of English reset the "prodrop" parameter of Korean into "non-prodrop" parameter of English in the process of English acquisition. An experiment was conducted to 45 Korean learners of English on the prodrop phenomenon, namely on the null referential or null nonreferential subject, and subject-verb agreement by way of grammatical judgment. The results of the experiment are as follows: First, L2 learners follow the parameter of L1, and then reset the parameter of L2 regardless of the parameter of L1 as their L2 abilities advance. Thus, this study provides further support for the hypothesis that universal grammar is available via L1. Second, the referential subject is, at first, easier to acquire than nonreferential subject, and the triggering fact for the switch from [+prodrop] to [-prodrop] was the use of nonreferential subjects. Third, 3rd person agreement has no connection with the acquisition of the prodrop parameter as a result of subject-verb agreement. Therefore, these results indicate that verb agreement is not a trigger for the recognition of the obligatory subject.

  • PDF