• Title/Summary/Keyword: Research of Dentistry

검색결과 4,675건 처리시간 0.032초

Effect of acidic solutions on the microhardness of dentin and set OrthoMTA and their cytotoxicity on murine macrophage

  • Oh, Soram;Perinpanayagam, Hiran;Lee, Yoon;Kum, Jae-Won;Yoo, Yeon-Jee;Lim, Sang-Min;Chang, Seok Woo;Shon, Won-Jun;Lee, Woocheol;Baek, Seung-Ho;Kum, Kee-Yeon
    • Restorative Dentistry and Endodontics
    • /
    • 제41권1호
    • /
    • pp.12-21
    • /
    • 2016
  • Objectives: To evaluate the effects of three acids on the microhardness of set mineral trioxide aggregate (MTA) and root dentin, and cytotoxicity on murine macrophage. Materials and Methods: OrthoMTA (BioMTA) was mixed and packed into the human root dentin blocks of 1.5 mm diameter and 5 mm height. Four groups, each of ten roots, were exposed to 10% citric acid (CA), 5% glycolic acid (GA), 17% ethylenediaminetetraacetic acid (EDTA), and saline for five minutes after setting of the OrthoMTA. Vickers surface microhardness of set MTA and dentin was measured before and after exposure to solutions, and compared between groups using one-way ANOVA with Tukey test. The microhardness value of each group was analyzed using student t test. Acid-treated OrthoMTA and dentin was examined by scanning electron microscope (SEM). Cell viability of tested solutions was assessed using WST-8 assay and murine macrophage. Results: Three test solutions reduced microhardness of dentin. 17% EDTA demonstrated severe dentinal erosion, significantly reduced the dentinal microhardness compared to 10% CA (p = 0.034) or 5% GA (p = 0.006). 10% CA or 5% GA significantly reduced the surface microhardness of set MTA compared to 17% EDTA and saline (p < 0.001). Acid-treated OrthoMTA demonstrated microporous structure with destruction of globular crystal. EDTA exhibited significantly more cellular toxicity than the other acidic solutions at diluted concentrations (0.2, 0.5, 1.0%). Conclusions: Tested acidic solutions reduced microhardness of root dentin. Five minute's application of 10% CA and 5% GA significantly reduced the microhardness of set OrthoMTA with lower cellular cytotoxicity compared to 17% EDTA.

Effect of Metformin on Cell Growth and Differentiation in Cultured Odontoblasts

  • Oh, Chang Young;Kim, Su-Gwan;Go, Dae-San;Yu, Sun-Kyoung;Kim, Tae-Hoon;Kim, Chun Sung;Park, Joo-Cheol;Kim, Do Kyung
    • International Journal of Oral Biology
    • /
    • 제42권2호
    • /
    • pp.39-45
    • /
    • 2017
  • Metformin (1,1-dimethylbiguanide hydrochloride), derived from French lilac (Galega officinalis), is a first-line anti-diabetic drug prescribed for patients with type 2 diabetes. However, the role of metformin in odontoblastic cell differentiation is still unclear. This study therefore undertook to examine the effect of metformin on regulating odontoblast differentiation in MDPC-23 mouse odontoblastic cells derived from mouse dental papilla cells. As compared to controls, metformin significantly accelerated the mineralization, significantly increased and accelerated the expressions of ALP and Col I mRNAs, and significantly increased the accelerated expressions of DSPP and DMP-1 mRNAs, during differentiation of MDPC-23 cells. There was no alteration in cell proliferation of MDPC-23 cells, on exposure to metformin. These results suggest that the effect of metformin on MDPC-23 mouse odontoblastic cells derived from mouse dental papilla cells, facilitates the odontoblast differentiation and mineralization, without altering the cell proliferation.

Comparison of retentive force and wear pattern of Locator® and ADD-TOC attachments combined with CAD-CAM milled bar

  • Chae, Sung-Ki;Cho, Won-Tak;Choi, Jae-Won;Bae, Eun-Bin;Bae, Ji-Hyeon;Bae, Gang-Ho;Huh, Jung-Bo
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권1호
    • /
    • pp.12-21
    • /
    • 2022
  • PURPOSE. The purpose of this study was to investigate changes in retention and wear pattern of Locator® and ADD-TOC attachments on a digital milled bar by performing chewing simulation and repeated insertion/removal of prostheses in fully edentulous models. MATERIALS AND METHODS. Locator (Locator®; Zest Anchors Inc., Escondido, CA, USA) was selected as the control group and ADD-TOC (ADD-TOC; PNUAdd Co., Ltd., Busan, Republic of Korea) as the experimental group. A CAD-CAM milled bar was mounted on a master model and 3 threaded holes for connecting a bar attachment was formed using a tap. Locator and ADD-TOC attachments were then attached to the milled bar. Simulated mastication and repeated insertion/removal were performed over 400,000 cyclic loadings and 1,080 insertions/removals, respectively. Wear patterns on deformed attachment were investigated by field emission scanning electron microscopy. RESULTS. For the ADD-TOC attachments, chewing simulation and repeated insertion/removal resulted in a mean initial retentive force of 24.43 ± 4.89 N, which were significantly lower than that of the Locator attachment, 34.33 ± 8.25 N (P < .05). Amounts of retention loss relative to baseline for the Locator and ADD-TOC attachments were 21.74 ± 7.07 and 8.98 ± 5.76 N (P < .05). CONCLUSION. CAD-CAM milled bar with the ADD-TOC attachment had a lower initial retentive force than the Locator attachment. However, the ADD-TOC attachment might be suitable for long-term use as it showed less deformation and had a higher retentive force after simulated mastication and insertion/removal repetitions.

Micro-computed tomography in preventive and restorative dental research: A review

  • Ghavami-Lahiji, Mehrsima;Davalloo, Reza Tayefeh;Tajziehchi, Gelareh;Shams, Paria
    • Imaging Science in Dentistry
    • /
    • 제51권4호
    • /
    • pp.341-350
    • /
    • 2021
  • Purpose: The use of micro-computed tomography (micro-CT) scans in biomedical and dental research is growing rapidly. This study aimed to explore the scientific literature on approaches and applications of micro-CT in restorative dentistry. Materials and Methods: An electronic search of publications from January 2009 to March 2021 was conducted using ScienceDirect, PubMed, and Google Scholar. The search included only English-language articles. Therefore, only studies that addressed recent advances and the potential uses of micro-CT in restorative and preventive dentistry were selected. Results: Micro-CT is a tool that enables 3-dimensional imaging on a small scale with very high resolution. In this method, there is no need for sample preparation or slicing. Therefore, it is possible to examine the internal structure of tissue and the internal adaptation of materials to surfaces without destroying them. Due to these advantages, micro-CT has been recommended as a standard imaging tool in dental research for many applications such as tissue engineering, endodontics, restorative dentistry, and research on the mineral density of hard tissues and bone growth. However, the high costs of micro-CT, the time necessary for scanning and reconstruction, computer expertise requirements, and the enormous volume of information are drawbacks. Conclusion: The potential of micro-CT as an emerging, accurate, non-destructive approach is clear, and the valuable research findings reported in the literature provide an impetus for researchers to perform future studies focusing on employing this method in dental research.

Cefuroxime axetil의 치주병원성 세균에 대한 최소억제농도와 치은열구액 농도에 관한 실험적 연구 (GCF concentration and minimal inhibitory concentration of cefuroxime axetil against periodontopathogens)

  • 장현선;김재덕;국중기;김화숙;유소영;김미광;김병옥
    • Journal of Periodontal and Implant Science
    • /
    • 제33권3호
    • /
    • pp.341-348
    • /
    • 2003
  • The purpose of this study was to determine the minimal inhibitory concentration (MIC) of cefuroxime axetil, semisynthetic cefalosporin, for some putative periodotopathogens; F. nucleatum, A. actinomycetemcomitans P. intermedia and P. gingivalis. To investigate the efficacy of cefuroxime axetil, several antibiotics, amoxicillin, metronidazole, and ciprofoxacine, were used as control. The MIC was measured by Murray' s method. The MIC of cefuroxime axetil against some putative microbes, as a single use regimen, was relatively high in comparison with that of the other antibiotics used in this study. The MIC of cefuroxime axetil/metronidazole against some putative microbes, as a simultaneous regimen, was similar to that of the other antibiotics used in this study. The manimal level of cefuroxime concentration in gingival fluid was 9${\mu}$/ml at 36hr after the first dose. In conclusion, within the limited experiment, metronidazole/ cefuroxime axetil therapy of periodontitis may provide a therapeutic benefits in reducing the periodontopathogens.

근관치료용 실러가 치아변색과 실활치 미백에 미치는 영향 (Effects of various root canal sealers on tooth discoloration and internal bleaching)

  • 김이산;최성현;윤경은;장지현;장훈상;황윤찬;황인남;오원만;이빈나
    • 대한치과재료학회지
    • /
    • 제46권1호
    • /
    • pp.1-10
    • /
    • 2019
  • 근관치료 후 발생하는 치아변색은 여러 가지 원인에 의해 나타나는 것으로 알려져 있다. 본 실험은 근관치료 후 치아변색이 일어나는 여러 원인 중 실러 종류에 따른 영향을 평가하고 변색을 치료하기 위한 방법으로 실활치 미백을 시행할 경우 미백 효과 정도를 비교해 보는 것이다. 24개의 치아를 대조군, AH plus, Endosequece BC, MTA fillapex군 4개의 군으로 나누어 실험하였다. 실러를 사용하여 통상적인 방법으로 근관충전을 시행한 후 과붕산나트륨을 이용하여 실활치 미백을 시행 하였다. 그 후 Vita easyshade를 사용하여 치아의 색을 CIE L*a*b 시스템으로 측정하였다. 근관충전 후 변색실험에서 대조군과 모든 실험군에서 시간에 따라 치아의 색이 변하였다. 미백제의 효과에 대해서는 Endosequence BC와 MTA fillapex에서 AH plus군에 비해 미백효과가 유의하게 높은 결과가 나타냈다. 본 연구를 바탕으로 근관치료 시 실러의 주의 깊은 사용이 필요하며, epoxy resin 계열에 비해 Calcium silicate 계열의 실러로 인한 치아 변색에서 과붕산나트륨을 이용한 미백은 효율적일 수 있다.

치과용 분광광도계를 이용한 상악 유전치의 색조 분포에 관한 연구 (Color distribution of maxillary primary incisors using a dental spectrophotometer in Korean children)

  • 송지수;신터전;현홍근;김영재;김정욱;장기택;이상훈
    • 대한치과의사협회지
    • /
    • 제58권8호
    • /
    • pp.476-485
    • /
    • 2020
  • The purpose of this study was to analyze the color distribution of the maxillary primary central and lateral incisors using a dental spectrophotometer. Color measurements of maxillary primary central and lateral incisors of 32 pediatric patients aged 2 to 6 years were performed using SpectroShade Handy Dental Type 713000 (Serial No. HDL2678, MHT, Verona, Italy) by one researcher in the same clinic. CIE L*, a*, b* values of total surfaces and cervical, middle, incisal region were recorded. L* values were higher and a* values were lower in the primary central incisors than those in primary lateral incisors, but b* values didn't show statistical difference. L* values of the middle region were the highest, and a* and b* values decreased from the cervical region to the incisal region. There were significant color differences between each region, and ΔE*ab between each region were greater than ΔE*ab between the primary central and lateral incisors. For esthetic restorations of primary incisors, it is necessary to consider the color differences between each region rather than those between the primary central and lateral incisors.

  • PDF

Effect of immersion into solutions at various pH on the color stability of composite resins with different shades

  • Moon, Ji-Deok;Seon, Eun-Mi;Son, Sung-Ae;Jung, Kyoung-Hwa;Kwon, Yong-Hoon;Park, Jeong-Kil
    • Restorative Dentistry and Endodontics
    • /
    • 제40권4호
    • /
    • pp.270-275
    • /
    • 2015
  • Objectives: This study examined the color changes of a resin composite with different shades upon exposure to water with different pH. Materials and Methods: Nanohybrid resin composites (Filtek Z350XT, 3M ESPE) with four different shades (A2, A3, B1, and B2) were immersed in water with three different pH (pH 3, 6, and 9) for 14 day. The CIE $L^*a^*b^*$ color coordinates of the specimens were evaluated before and after immersion in the solutions. The color difference (${\Delta}E^*$) and the translucency parameter (TP) were calculated using the color coordinates. Results: ${\Delta}E^*$ ranged from 0.33 to 1.58, and the values were affected significantly by the pH. The specimens immersed in a pH 6 solution showed the highest ${\Delta}E^*$ values (0.87 - 1.58). The specimens with a B1 shade showed the lowest ${\Delta}E^*$ change compared to the other shades. TP ranged from 7.01 to 9.46 depending on the pH and resin shade. The TP difference between before and after immersion in the pH solutions was less than 1.0. Conclusions: The resulting change of color of the tested specimens did not appear to be clinically problematic because the color difference was < 1.6 in the acidic, neutral, and alkaline solutions regardless of the resin shade, i.e., the color change was imperceptible.

상아질 접착에서 collagenase와 esterase가 미세인장결합강도에 미치는 영향 (THE EFFECTS OF COLLAGENASE AND ESTERASE ON THE MICROTENSILE BOND STRENGTH IN DENTIN BONDING)

  • 정영정;현홍근;김영재;김정욱;이상훈;김종철;한세현;장기택
    • 대한소아치과학회지
    • /
    • 제34권2호
    • /
    • pp.285-291
    • /
    • 2007
  • 상아질-레진 접착강도에 대한 collagenase와 esterase의 영향을 살펴보기 위해, 소구치의 교합면 상아질에 Single Bond 2와 Clearfil SE Bond로 접착을 시행하고 미세 시편을 제작하여 PBS collagenase 용액, esterase 용액에 4주간 보관한 후 미세인장결합강도를 측정, 비교하여 다음과 같은 결론을 얻었다. 1. 모든 보관 용액에서 Single Bond 2의 미세인장결합강도는 Clearfil SE Bond보다 유의하게 낮았다(p<0.05). 2. Single Bond 2의 미세인장결합강도는 collagenase군이 PBS군, esterase군보다 낮았다(p>0.05). 3. Clearfil SE Bond의 미세인장결합강도는 esterase군이 PBS군에 비해 낮았으나(p>0.05), collagenase군보다는 높았다(p>0.05). Collagenase군은 PBS군에 비해 유의하게 낮은 미세인장결합강도를 보였다(p<0.05).

  • PDF

전단접착강도와 관련된 Plasma Arc Curing Light의 중합효율평가 (Shear bond strength of dentin bonding agents cured with a plasma arc curing light)

  • 권영철;김선영;정세준;한영철;이인복;손호현;엄정문;조병훈
    • Restorative Dentistry and Endodontics
    • /
    • 제33권3호
    • /
    • pp.213-223
    • /
    • 2008
  • 광물리학적 특성 분석을 위해 Apollo 95E (DMT Systems, Orange, CA; PAC 광중합기), Elipar Freelight 2 (3M ESPE, MN, USA; LED 광중합기) 그리고 VIP Junior (Bisco, Schaumberg, IL, USA; QTH 광중합기), 3종의 광중합기의 총광강도(Total intensity)와 spectral distribution을 측정하였고 특정 파장에 해당되는 광강도 (Energy density)를 분석하였다. 상아질 전단접착강도의 측정을 위해 Scotchbond Multipurpose (3M ESPE), Single bond (3M ESPE) 그리고 Clearfil SE bond (Kuraray)가 사용되었다. Plasma Arc Curing light (Apollo 95E) 광중합기는 여러개의 최대정점을 가지며 넓은 spectral distribution과 $2307mw/cm^2$의 높은 광강도를 나타내었고, VIP Junior 광중합기는 490nm에서 최대정점을 갖는 넓은 spectral distribution을 나타내었고, Elipar Freeelight 2 광중합기는 462 nm의 최대정점 주위로 좁은 spectral distribution을 보였다. Two-Way ANOVA와 Bonferroni's multiple comparison test를 이용하여 상아질 전단접착강도를 분석한 결과, PAC 광중합기와 LED 광중합기 간에 유의성 있는 차이를 보이지 않았으며 (P > 0.05), 상아질 접착제와 광중합기의 교호관계에도 유의성이 없었다. 그러나 상아질 접착제는 상호간에 유의성 있는 차이를 보였다 (P < 0.001).