• Title/Summary/Keyword: Replacement method

Search Result 1,404, Processing Time 0.027 seconds

A Case of Carotid Artery Resection and Replacement (경동맥 절제술 및 치환술 1례)

  • Kim, Dea-Sik;Oh, Cheon-Hwan
    • Korean Journal of Bronchoesophagology
    • /
    • v.5 no.2
    • /
    • pp.202-206
    • /
    • 1999
  • A carotid artery resection and replacement including neck dissection are used as a method of treatment for head and neck cancer with infiltration into the carotid artery. The recent development of imaging technique makes it easy to estimate the detailed anatomical relationship between the tumor infiltration into the carotid artery, it's resection and replacement are indicated at radical neck dissection. To detect any possibility of cerebral ischemia at the time of ligation of carotid artery, a temporary occlusion test of internal carotid artery with a ballon catheter (balloon occlusion test) is performed. Recently, we performed a carotid artery resection and replacement using an artificial vessel Gore-Tex) in a case of neck cancer with infiltration into the carotid artery.

  • PDF

Properties of Non-cement Matrix Using Biomass Fly Ash (바이오매스 플라이애시를 활용한 무시멘트 경화체의 특성)

  • Kim, Dae-Yeon;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.185-186
    • /
    • 2020
  • This study In order to reduce the amount of cement that generates a large amount of carbon dioxide and attempts to find a recycling method to solve environmental problems by using biomass fly ash. Experiments were conducted according to replacement ratio of biomass fly ash based on GGBFS, The test items are flowability, air content, unit volume weight, water absorption, flexural strength and compressive strength. As a result of the experiment, as increased replacement ratio of biomass fly ash, the flowability and air content was increased. As increased replacement ratio, the density was decreased and water absorption was increased. The compressive strength tended to decrease as increased replacement ratio. The flexural strength tended to increased as increased replacement ratio.

  • PDF

The Effect of Ground Granulated Blast Furnace Slag Replacement on Alkali -Silica Reaction (고로슬래그 미분말 치환에 따른 알칼리-실리카 반응 팽창 저감효과)

  • Kim Ji Hyun;Jun Ssang Sun;Um Jang Sub;Jin Chi Sub
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.431-434
    • /
    • 2005
  • The effect of ground granulated blast furnace slag to prevent detrimental expansion due to alkali-silica reaction was investigated through the ASTM C 1260 method. This method is one of the most commonly used method because results can be obtained within 16 days. Reactive aggregate used is a metamorphic rock. The replacement ratios of portland cement by ground granulated blast furnace slag were 0, 15, 25, 35 and 55 percent, respectively. The results indicate that 35 percent replacement of portland cement by ground granulated blast furnace slag seems to be effective to reduce alkali-silica reaction expansion under this experimental conditions.

  • PDF

Optimal Number of Failures before Group Replacement under Minimal Repair

  • Young Kwan, Yoo
    • Journal of the Korea Safety Management & Science
    • /
    • v.6 no.1
    • /
    • pp.61-70
    • /
    • 2004
  • In this paper, a group replacement policy based on a failure count is analysed. For a group of identical repairable units, a maintenance policy is performed with two phase considerations: a repair interval phase and a waiting interval phase. Each unit undergoes minimal repair at failure during the repair interval. Beyond the interval, no repair is made until a number of failures. The expected cost rate expressions under the policy is derived. A method to obtain the optimal values of decision variables are explored. Numerical examples are given to demonstrate the results.

The Effect of Meta-Kaolin Replacement on Alkali-Silica Reaction (메타카올린 치환에 따른 알칼리-실리카 반응 팽창 저감효과)

  • Jun Ssang Sun;Lee Hyomin;Jin Chi Sub;Hwang Jin Yeon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.360-363
    • /
    • 2004
  • The effectiveness of Meta-Kaolin to prevent detrimental expansion due to alkali-silica reaction was investigated through the ASTM C 1260 method. Reactive aggregate used is a metamorphic rock. The replacement proportions of portland cement by Meta-Kaolin were 0, 5, 10, 15, 25 and 35 percent, respectively. The results indicate that 25 percent replacement of portland cement by Meta-Kaolin seems to be most effective to reduce alkali-silica reaction expansion under this experimental conditions.

  • PDF

Dynamic Replacement Models with Different Technology Levels (다른 기술수준을 갖는 동적장비교체에 관한 연구)

  • 고현우
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.17 no.32
    • /
    • pp.209-220
    • /
    • 1994
  • In this paper, we study the timing and equipment of replacement. Those affect both available possibility and technological levels of new equipments in the future. These problems are classified according to technological levels and in consequence generated four circumstance. Models are formulated in this research. These are able to make us decision which we replace equipment at the first time. A method is suggested to find the optimal age for replacement at given each circumstance. A solution procedure and numerical example are given.

  • PDF

A New Cache Replacement Policy for Improving Last Level Cache Performance (라스트 레벨 캐쉬 성능 향상을 위한 캐쉬 교체 기법 연구)

  • Do, Cong Thuan;Son, Dong Oh;Kim, Jong Myon;Kim, Cheol Hong
    • Journal of KIISE
    • /
    • v.41 no.11
    • /
    • pp.871-877
    • /
    • 2014
  • Cache replacement algorithms have been developed in order to reduce miss counts. In modern processors, the performance gap between the processor and main memory has been increasing, creating a more important role for cache replacement policies. The Least Recently Used (LRU) policy is one of the most common policies used in modern processors. However, recent research has shown that the performance gap between the LRU and the theoretical optimal replacement algorithm (OPT) is large. Although LRU replacement has been proven to be adequate over and over again, the OPT/LRU performance gap is continuously widening as the cache associativity becomes large. In this study, we observed that there is a potential chance to improve cache performance based on existing LRU mechanisms. We propose a method that enhances the performance of the LRU replacement algorithm based on the access proportion among the lines in a cache set during a period of two successive replacement actions that make the final replacement action. Our experimental results reveals that the proposed method reduced the average miss rate of the baseline 512KB L2 cache by 15 percent when compared to conventional LRU. In addition, the performance of the processor that applied our proposed cache replacement policy improved by 4.7 percent over LRU, on average.

The Thracoabdominal Aortic Replacement Using Deep Hypothermic Circulatory Arrest Technique (흉복부대동맥치환술에서 극저체온하순환정지법의 효과)

  • Woo, Jong-Su;Bang, Jung-Hee;Kim, Si-Ho;Choi, Pil-Jo;Cho, Kwang-Jo
    • Journal of Chest Surgery
    • /
    • v.39 no.3 s.260
    • /
    • pp.194-200
    • /
    • 2006
  • Background: Thoracoabdominal aortic replacement is an extensive operation that opens both the pleural cavity and abdominal cavity, which has high mortality and morbidity rate. The authors have reported 9 cases of the thoracoabdominal aortic replacement in 2001. Since 2003 we have applied the deep hypothermic circulatory arrest to the Crawford type I and II thoracoabdominal aortic replacement. Therefore, we analysed the effect of the changes in operative techniques. Material and Method: Between 1996 and 2005, we have performed 20 cases of thoracoabdominal aortic replacement. The underlying diseases were 8 cases of atherosclerotic aneurysm with 4 cases of ruptured aneurysm and 12 cases of aortic dissection with 10 cases of a previous operations. According to Crawford classification, there were 2 cases of type I, 7 cases of type II, 1 case of type III, 7 cases of type IV, and 3 cases of type V. We compaired the results of the patients who underwent thoracoabdmoninal replacement before 2001 which already has been reported and after then. Result: Before 2001 we have performed 9 cases of thoracoabdominal replacement and 5 patients were died of the operation. All three patients with type I and II were died. There was no case of thoracoabdominal replacement between 2001 and 2002, but after 2003 we have performed 11 cases of thoracoabdominal replacement which involved 1 case of type I, 5 cases of type II, 1 case of type III, 2 cases of type IV and 2 cases of type V. There was no mortality and no fetal complications. Conclusion: The deep hypothermic circulatory arrest is a safe method of extended thoracoabdominal aortic replacement.

Improvement Effect and Field Application of Dynamic Replacement Using Crushed Rock (암버력 매립층의 동치환공법 현장 적용성 및 개량효과에 관한 연구)

  • Lee, In-Hwan;Lee, Chul-Hee;Shin, Eun Chul
    • Journal of the Korean Geosynthetics Society
    • /
    • v.18 no.4
    • /
    • pp.1-13
    • /
    • 2019
  • The purpose of this study is to examine the effect of soft ground improvement by dynamic replacement with utilizing crushed rock. In order to understand the ground improvement effect when applying dynamic replacement method with crushed rock, the laboratory test and field test were performed. The internal friction angle and apparent cohesion were derived through direct shear test. The dynamic replacement characteristics were identified by analyzing the weight, drop, and number of blows needed for dynamic replacement. Through the field plate bearing test and density test, the bearing capacity and settlement of the improved ground were measured, and the numerical analysis were conducted to analyze the behavior of the improved ground. In this study, it proposes modified soil experimental coefficient(CDR) to 0.3~0.5 in the dynamic replacement method with crushed rock. Also when applying the dynamic replacement method using crushed rock, the particle size range is less than 100 mm, D90 is less than 80 mm and D15 is more than 30 mm.

Optimal Spare Provisioning for Group Replacement Policy (경제적인 그룹교체보전을 위한 최적 예비품 재고수준의 결정)

  • Yoo, Young Kwan;Park, Roh Gook
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.9 no.2
    • /
    • pp.81-86
    • /
    • 2014
  • In this paper, a jointly optimal group replacement and spare provisioning policy is presented. Most maintenance policies assume that the spare inventory is always available, but in practice the maintenance schedule is affected by the availability of spare inventory. We present a maintenance-inventory model which jointly optimizes the group replacement interval and spare ordering quantity. Group replacement policy is used when a group of units are put in operation simultaneously. The operating fleet is replaced altogether at a predetermined number of units are failed. A sufficient level of spare inventory is carried to perform a number of group replacement. A cost rate expression which considers the group maintenance cost and inventory holding cost is derived and a heuristic method for searching the optimum value of decision variables is suggested. Numerical examples demonstrate the analytical results and the performance of the presented model.

  • PDF