• 제목/요약/키워드: Replacement Ratio of Aggregate

검색결과 306건 처리시간 0.026초

풍쇄슬래그 잔골재를 사용한 콘크리트의 공학적 특성에 관한 실험적 연구 (An Experimental Study on the Engineering Properties of Concrete using Fine Aggregate of PS ball Slag)

  • 이상수;송하영;김을용
    • 한국건축시공학회지
    • /
    • 제6권3호
    • /
    • pp.107-114
    • /
    • 2006
  • In this study, the experiment was carried out to investigate and analyze the engineering properties of concrete using fine aggregate of PS bal slagl. The main experimental variables were water/cement ratio 30, 40, 50(%), water content $170kg/m^3$, replacement ratio of slag fine aggregate 0, 25, 50, 75(%) in experiment I and water/cement ratio 30, 40, 50(%), water content 165, 170, 175($kg/m^3$), replacement ratio of fine aggregate of PS ball 0, 50 in experiment II. According to the test results, the principle conclusions are summarized as follows (1) The workability of slag fine aggregate-mixed concrete tends to improve, as the replacement rate increases. (2) The air content of slag fine aggregate-mixed concrete tends to decrease, as the replacement rate increases. (3) The unit volume weight of slag fine aggregate-mixed concrete tends to significantly increase, as the replacement rate increases. (4) The compressive strength of slag fine aggregate-mixed concrete tends to show more increasing propensity, in case the curing period is relatively long, as the replacement rate increases.

인공경량골재 혼합비율에 따른 경량 콘크리트의 물성 및 강도특성에 관한 연구 (The Study on the Physical and Strength Properties of Lightweight Concrete by Replacement Ratio of Artificial Lightweight Aggregate)

  • 최세진;김도빈;이경수;김영욱
    • 한국건축시공학회지
    • /
    • 제19권4호
    • /
    • pp.313-322
    • /
    • 2019
  • 본 연구는 최근 사용량이 증대하고 있는 저시멘트 배합을 대상으로 국내생산 인공경량 잔 굵은골재의 혼합비율에 따른 경량콘크리트의 물성 및 강도특성을 비교 검토한 것으로서 실험결과, 프리웨팅 시간이 24시간 증가할 경우 모르타르 플로우값이 약 3~5% 감소하는 것으로 나타났으며 경량잔골재 사용에 의해 모르타르 배합에서 약 10.4%의 기건단위질량 감소효과를 얻을 수 있는 것으로 나타났다. 또한 경량굵은골재의 혼합비율에 따른 경량콘크리트의 기건단위질량은 5~10mm 크기인 LWG10 경량굵은골재의 혼합비율이 높아질수록 선형적으로 기건단위질량이 증가하였으며 LWG10 경량굵은골재를 혼합할 경우 LWG10 혼합비율에 관계없이 재령 7일에 약 30~31MPa 수준의 유사한 압축강도를 발현하였다.

치환율에 따른 순환골재 콘크리트의 구조성능 분석 (Evaluations of Structural Performance of Recycled Aggregate Concrete According to Replacement Ratios)

  • 남진원;김호진;김성배;김장호;변근주
    • 한국건설순환자원학회논문집
    • /
    • 제3권1호
    • /
    • pp.54-64
    • /
    • 2007
  • This study is a fundamental research in order to establish the design code of recycled aggregate concrete structure. The structural properties of recycled aggregate concrete such as flexure, shear, fatigue, compression, and bond development are experimentally investigated and confirmed. In this study, laboratory-scale reinforced concrete beam, column, and pull-out test specimens using recycled coarse aggregate are manufactured. Then, the structural performances of recycled aggregate concrete according to replacement ratios of recycled coarse aggregate are evaluated. Also, finite element analysis using commercial code DIANA is carried out to predict the test results and the analysis results are compared with test results in this study. Structural test results showed that the structural performances of recycled aggregate concrete specimens with 60% replacement ratio are reduced by approximately 15-20%. These results indicated that the replacement ratio of recycled coarse aggregate within 30% is a suitable to use for structural members. The results of finite element analysis showed that the specimens with 30% replacement ratio possessed similar or more excellent structural performance than normal concrete specimens. However, recycled aggregate concrete with 60% replacement ratio of recycled coarse aggregate must be carefully considered for structural applications due to significant decrease of the failure loads.

  • PDF

폐전주 재생골재의 기초물성 및 대체율에 따른 고강도영역 재생골재 콘크리트의 특성에 관한 실험적 연구 (An Experimental Study on the Fundamental Properties of Electric Pole Recycled Aggregate(EPRA) and Characteristics of High Strength Concrete by Replacement Ratios of EPRA)

  • 이강우;이종호;강석표;최세진;최희용;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.495-500
    • /
    • 2001
  • In this study, it was analized and examined fundamental properties of Electric Pole Recycled Aggregate(EPRA) and hardened properties & chemical resistance with H$_2$SO$_4$by replacement ratios of EPRA, and the results are as follows 1) In the case of electric pole recycled coarse aggregate, All fundamental properties are better than that of normal recycled aggregate and both water absorption and amount of crushed loss are with level of natural aggregate 2) As the replacement ratio of electric pole recycled fine aggregate is increased strength development is decreased. but in the case of coarse aggregate, that of it is with level of natural aggregate 3) As the replacement ratio of electric pole recycled fine aggregate is increased chemical resistance is decreased. but in the case of coarse aggregate, that of it is with level of natural aggregate

  • PDF

순환골재를 이용한 환경 친화형 호안 블록제품의 개발에 관한 연구 (Study on the development of environment-friendly tetrapod using recycled aggregate)

  • 박도경;이명규;양극영
    • 한국건축시공학회지
    • /
    • 제6권2호
    • /
    • pp.73-79
    • /
    • 2006
  • The purpose of this study is to enhance the development of construction waste-recycling technologies and its economical efficiency by developing environment-friendly tetrapod, precast concrete, where recycled aggregate is used in order to promote recycling of waste concrete. The results of concrete mechanic characteristics experiments by the circulation coarse aggregate-replacement ratio are as the following. The circulation aggregate is lower and higher than natural aggregate in specific gravity and absorption ratio, respectively so that in case of mix proportioning, unit volume increases, while unit aggregate amount decreases. From the result, sufficient experiments of physical characteristics of circulation aggregate are required to get proper mix proportioning. When circulation aggregate-replacement ratio increases, compressive strength tends to decrease comprehensively, but 50% of replacement ratio is good enough to use. When circulation coarse aggregate's replacement ratio is 0%, drying shrinkage, which causes cracks in concrete and deteriorates durability, shows the minimum length change and the higher the ratio, the larger the length change. Thus. when using circulation coarse aggregate, drying shrinkage should be fairly examined. In freezing-and-thawing resistance, weight loss tends to comprehensively increase its loss at the circulation aggregate-mixed site. And the examination of surface aggregate-omission ratio is further needed and dynamic elastic modulus and durability factor(DF) require more study as well. In order to use circulation aggregate to tetrapod, a clear standard for strength should be first prepared and at the same time, more study about durability is needed.

고강도 경량 자기충전콘크리트의 성능평가 (Properties of High Strength Lightweight Self-Compacting Concrete)

  • 최연왕;문대중;안성일;최욱;조선규
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.413-416
    • /
    • 2003
  • Experimental tests on the high strength self-compacting concrete with light-weight fine aggregate and light-weight coarse aggregate(LHSSC) were performed with slump-flow, reaching time to the slump-flow of 500mm, V-funnel dropping time and U-box difference level and compressive strength. LHSCC with light-weight fine aggregate of 75% and light-weight coarse aggregate of 100% was only satisfied with the property conditions of second self-compacting concrete(SCC), like as flowability, resistance to segregation and filling ability. The 28-day compressive strength of LHSCC indicated above 300kgf/$\textrm{cm}^2$ in all concrete mixtures, and it was increased to increase the replacement ratio of light-weight fine aggregate or to decrease the replacement ratio of light-weight coarse aggregate. Therefore, for satisfying the properties of fresh SCC and hardened concrete with above 350kgf/$\textrm{cm}^2$, it would expected that the replacement ratio of light-weight fine aggregate and light-weight coarse aggregate will be determined with 50~75% and 25~50%, respectively.

  • PDF

순환골재 콘크리트의 염화물 확산성에 관한 연구 (A Study on the Chloride Diffusivity of Recycled Aggregate Concrete)

  • 배종민;김영수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 추계 학술논문 발표대회
    • /
    • pp.87-91
    • /
    • 2009
  • Recycling demolished concrete as an alternative source of coarse aggregates for the production of new concrete can help solve the growing waste disposal crisis and the problem of depleted natural aggregates. The purpose of this study is to investigate chloride migration of recycled aggregate concrete containing pozzolanic materials by chloride migration coefficient. The specimens were made with recycled coarse aggregate as various replacement ratio(10, 30, 50%) and metakaolin, blast furnace slag, fly ash is replaced for recycled concrete with mixing ratio 20%. The major results are as follows. 1) Compressive strength of recycled aggregate concrete containing pozzolanic materials increase as curing age and chloride migration decrease. 2) When the replacement ratio of recycled coarse aggregate is 30%, the chloride migration coefficient of recycled concrete containing blast furnace slag, metakaolin shows the similar or lower value than plain concrete at all ages.

  • PDF

부순모래 치환율별 목표슬럼프 값 고정에 따른 화학혼화제의 특성에 관한 연구 (A Study on the Chemical Admixture According to Target Slump Value by Crushed Sand Replacement Rate)

  • 류현기;조명근
    • 한국건축시공학회지
    • /
    • 제8권4호
    • /
    • pp.87-93
    • /
    • 2008
  • With an increased use of alternative aggregate due to exhaustion of quality aggregate resources, the amount of used crushed aggregates have been increased and as a result, development of admixture materials has also been improved and its amount of use is increasing from day to day in order to secure quality in concrete. Accordingly, the purpose of this study is to make concrete of good quality by using chemical admixture developed in this study by replacement rate of fine aggregate. At first, susceptibility, compressive strength ratio and length change ratio in both fresh and hardened concrete were evaluated according to corresponding regulation. As for high performance related regulation, APC NO.3 and PC series were going to rule, and as for AE agent regulation, replacement ratio of fine aggregate of high performance chemical admixture was 10:0 and other chemical admixture met quality regulation for AE agent.

수도권 부순모래의 품질특성 및 부순모래 대체율에 따른 콘크리트의 특성에 관한 실험적 연구 (An Experimental Study on the Properties of Crushed Sand in Capital Region and Concrete according to the Replacement Ratio of Crushed Sand)

  • 최세진;정용;박창수;오복진;여병철;김무한
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2004년도 학술.기술논문발표회
    • /
    • pp.51-55
    • /
    • 2004
  • Generally, aggregate may limit the strength of concrete, and aggregate with undesirable properties including strength, shape and grading etc. cannot produce good concrete. Also, the properties of aggregate greatly affect the durability and structural performance of concrete. Recently, it has increased the using of crushed aggregate for concrete due to the exhaustion of good natural aggregate. In case of Korea, the using ratio of crushed stone occupies about 97% of whole coarse aggregate, and ratio of crushed sand occupies about 18.3% of whole fine aggregate. This is an experimental study to compare and analyze the properties of crushed sand for concrete in capital region and concrete according to the replacement ratio of crushed sand to do suitable mix design and improve the concrete quality. According to results, it was found that nearly all the properties of crushed sand satisfied with the value recommended by KS.

  • PDF

수도권 부순모래의 품질현황 및 부순모래 대체율에 따른 콘크리트의 특성에 관한 연구 (An Experimental Study on the Properties of Crushed Sand in Capital Region and Concrete according to the Replacement Ratio of Crushed Sand)

  • 최세진;이성연;여병철;김무한
    • 한국건축시공학회지
    • /
    • 제5권1호
    • /
    • pp.63-68
    • /
    • 2005
  • Generally, aggregate may limit the workability, strength and durability of concrete, and good concrete cannot be made with aggregate of bad property including low strength, bad shape and grading. But recently, it has been insufficient in quantity to collect good natural aggregate because of exhaustion of aggregate resources. In case of Korea, the using ratio of crushed stone occupies about 97 percent of total coarse aggregate, and ratio of crushed sand occupies about 18.3 percent of total fine aggregate. This is an experimental study to compare and analyze the properties of crushed sand for concrete in capital region and concrete according to the replacement ratio of crushed sand to improve quality and mix design of concrete using crushed sand. According to test results, it was found that nearly all the properties of crushed sand satisfied with the value recommended by KS. And it is recommended that FM of crushed sand should be lowered by improvement of manufacture system or grading adjustment should be used because FM of crushed sand was a bit higher.