• 제목/요약/키워드: Renewable characteristics

검색결과 1,097건 처리시간 0.03초

모듈온도에 따른 전압-전력 특성 (P-V Characteristics According to the Module Temperature)

  • 홍정희;황준원;최용성;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.2148_2149
    • /
    • 2009
  • Development of renewable energy is promoted to achieve sustainability. So researchers are seeking and developing a new, clean, safe and renewable energy. However, solar energy is an extreme intermittent and inconstant energy source. In order to improve the photovoltaic system efficiency and utilize the solar energy more fully, and the DC power vary with module temperature, it is necessary to study the characteristics of photovoltaic P-V according to the external factors. This paper presents the analysis of characteristics of photovoltaic P-V according to the module temperature. The results show that it seems that when the module temperature increases, the DC power increases. But actually, because when the irradiation increases, the DC power increases, the result of the relationship between DC power and the module temperature of solar cell will be effects by the increasing irradiation.

  • PDF

영구자석 동기발전기와 회류수조를 이용한 조류발전 시스템의 특성 해석 (Analysis of the Characteristics of the Tidal Current Power Generation System Using PMSG and Water Tunnel)

  • 안원영;이석현;김근수;이강희;조철희
    • 신재생에너지
    • /
    • 제9권1호
    • /
    • pp.44-50
    • /
    • 2013
  • In order to analyze the characteristics of tidal current power generation system, we measured the output power according to the stream velocity by a water tunnel system and a simulation in MATLAB/Simulink. The water tunnel system consisted of impeller tidal flow transducer and PMSG with rotor in the water. The simulation consisted of PMSG, the tidal current turbine, and back-to-back converter. Also, we simulated the characteristics of output power according to the change of blade length and angular velocity.

바이오매스의 연소 성능과 회재 특성 (Biomass Combustion Performance and Ash Characteristics)

  • 문지홍;김광수;정재용;박민선;박은혜;윤정준;황정호;이은도
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2012년도 제44회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.227-229
    • /
    • 2012
  • Diversification of combustion fuel is the demands of the times and biomass is the most attractive option since it can contribute to the prevention of global warming at the same time. Due to the national renewable obligation, generally called Renewable Portfolio Standard (RPS), many power companies are considering direct combustion of biomass or co-firing with coal. In order to use biomass as a fuel, informations of its combustion characteristics and ash related problems should be investigated. In this study, combustion performance of biomass was assessed in a bubbling fluidized bed combustor, and ash characteristics of various biomass fuels were studied with standard test method.

  • PDF

고변압비와 고효율 특성을 가진 새로운 비절연형 벅부스트 컨버터 (A Novel Non-Isolated Buck Boost Converter with High Voltage Gain and High Efficiency Characteristics)

  • 트란 만 투안;사기르 아민;최우진
    • 전력전자학회논문지
    • /
    • 제24권5호
    • /
    • pp.319-326
    • /
    • 2019
  • The use of high-voltage gain converters is essential for distributed power generation systems with renewable energy sources, such as fuel and solar cells, due to their low-voltage characteristics. In this study, a novel high-voltage gain non-isolated buck boost converter topology is proposed to cope with the need of a high-voltage conversion ratio without the transformer for the renewable energy sources. Given that the proposed topology utilizes the cascode structure, the voltage gain and the efficiency are higher than those of other conventional non-isolated converters. To demonstrate the feasibility of the proposed topology, the operation principle is presented, and the steady-state characteristics are analyzed in detail. The validity of the proposed converter is verified by experiments with a 400 W prototype converter.

독립형 소형 풍력발전시스템 구성 및 운전특성 (Configuration and Operation characteristics of a Small stand-alone Wind Power Generation System)

  • 황인호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 추계학술대회 논문집
    • /
    • pp.65-68
    • /
    • 2002
  • Most of the present demand in the world is met by fossil and nuclear power plants. A small part is met by renewable energy technologies. Among the renewable power sources, wind and solar energy have experienced a remarkably rapid growth in the past 10 years. Recently the utilization of wind power has been receiving close attention in this country, especially for the electrification of off-shore islands. The objective of this study is to demonstrate a small wind energy system as a stand-alone power source.

  • PDF

Transient Characteristics and Physical Constraints of Grid-Tied Virtual Synchronous Machines

  • Yuan, Chang;Liu, Chang;Yang, Dan;Zhou, Ruibing;Tang, Niang
    • Journal of Power Electronics
    • /
    • 제18권4호
    • /
    • pp.1111-1126
    • /
    • 2018
  • In modern power systems, distributed generators (DGs) result in high stress on system frequency stability. Apart from the intermittent nature of DGs, most DGs do not contribute inertia or damping to systems. As a result, a new control method referred to as a virtual synchronous machine (VSM) has been proposed, which brought new characteristics to inverters such as synchronous machines (SM). DGs employing an energy storage system (ESS) provide inertia and damping through VSM control. Meanwhile, energy storage presents some physical constraints in the VSM implementation level. In this paper, a VSM mathematical model is built and analyzed. The dynamic responses of the output active power are presented when a step change in the frequency occurs. The influences of the inertia constant, damping factor and operating point on the ESS volume margins are investigated. In addition, physical constraints are proposed based on these analyses. The proposed physical constraints are simulated using PSCAD/EMTDC software and tested through RTDS experiment. Both simulation and RTDS test results verify the analysis.

A Probabilistic Approach to Small Signal Stability Analysis of Power Systems with Correlated Wind Sources

  • Yue, Hao;Li, Gengyin;Zhou, Ming
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권6호
    • /
    • pp.1605-1614
    • /
    • 2013
  • This paper presents a probabilistic methodology for small signal stability analysis of power system with correlated wind sources. The approach considers not only the stochastic characteristics of wind speeds which are treated as random variables with Weibull distributions, while also the wind speed spatial correlations which are characterized by a correlation matrix. The approach based on the 2m+1 point estimate method and Cornish Fisher expansion, the orthogonal transformation technique is used to deal with the correlation of wind farms. A case study is carried out on IEEE New England system and the probabilistic indexes for eigenvalue analysis are computed from the statistical processing of the obtained results. The accuracy and efficiency of the proposed method are confirmed by comparing with the results of Monte Carlo simulation. The numerical results indicate that the proposed method can actually capture the probabilistic characteristics of mode properties of the power systems with correlated wind sources and the consideration of spatial correlation has influence on the probability of system small signal stability.

에너지 자립섬 EMS 어플리케이션의 기능적 특성 (Functional Properties of Stand-alone Microgrid EMS Application)

  • 이하림;전영환;채우규;박중성
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권1호
    • /
    • pp.115-119
    • /
    • 2016
  • For many past years, research in the operation of stand-alone Microgrid, which provides electric power generated from renewable energy sources and energy storage system instead of diesel generators, has been a major issue in order to prepare the exhaustion of fossil fuel and to protect environment, in island grids. Samso Island, known as the world's first stand-alone Microgrid in Denmark, is connected to the mainland grid through AC system, which has different technical conditions with Korea's isolated power system. Korea's first stand-alone Microgrid has been built in Ga-sa island, Chun-la-nam-do, based on Energy Management System (EMS) operation, and other islands are under construction to follow the next step. These stand-alone Microgrid's has large capacity of Battery Energy Storage System (BESS) and the proportion of the renewable energy sources are large, which makes it necessary to use a Microgrid-Energy Management System (MG-EMS) to operate the grid effectively and economically. However, since the main subject of MG-EMS is different from EMS, specific characteristics and functions must be different as well. In this paper, the necessary characteristics and functions are explained for a general MG-EMS compared to a large power system EMS.

Type-II ZnO/ZnSe 코어/쉘 이종 구조 합성 및 광촉매활성 평가 (Synthesis and Characteristics of Type-II ZnO/ZnSe Core/Shell Heterostructures for High Efficient Photocatalytic Activity)

  • 이우형;최광일;강동천;백수웅;이석호;임철현
    • 한국전기전자재료학회논문지
    • /
    • 제27권3호
    • /
    • pp.178-183
    • /
    • 2014
  • Recently, various type of nanomaterials such as nanorod, nanowire, nanotube and their core/shell nanostructures have attracted much attention in photocatalyst due to their unique properties. Among them, Type-II core/shell heterostructures have extensively studied because it has exhibited improved electrical and optical properties against their single-component nanostructure. Such structures are expected to offer high absorption efficiency and fast charge transport due to their stepwised energetic combination and large internal surface area. Thus, it has been considered as potential candidates for high efficient photocatalytic activity. In this work, we introduce a novel chemical conversion process to synthesize Type-II ZnO/ZnSe core/shell heterostructures. A plausible conversion mechanism to ZnO/ZnSe core/shell heterostructres was proposed based on SEM, XRD, TEM and XPS analysis. The ZnO/ZnSe heterostructures exhibited excellent photocatalytic activity toward the decomposition of RhB dye compared to the ZnO nanorod arrays due to enhanced light absorption and the type-II cascade band structure.

주성분분석에 의한 TMY 특성 비교분석 (Comparative Analysis on the Characteristic of Typical Meteorological Year Applying Principal Component Analysis)

  • 김신영;김창기;강용혁;윤창열;장길수;김현구
    • 한국태양에너지학회 논문집
    • /
    • 제39권3호
    • /
    • pp.67-79
    • /
    • 2019
  • The reliable Typical Meteorological Year (TMY) data, sometimes called Test Reference Year (TRY) data, are necessary in the feasibility study of renewable energy installation as well as zero energy building. In Korea, there are available TMY data; TMY from Korea Institute of Energy Research (KIER), TRY from the Korean Solar Energy Society (KSES) and TRY from Passive House Institute Korea (PHIKO). This study aims at examining their characteristics by using Principle Component Analysis (PCA) at six ground observing stations. First step is to investigate the annual averages of meteorological elements from TMY data and their standard deviations. Then, PCA is done to find which principle components are derived from different TMY data. Temperature and solar irradiance are determined as the main principle component of TMY data produced by KIER and KSES at all stations whereas TRY data from PHIKO does not show similar result from those by KIER and KSES.